Normalized to: Oguri, S.
[1]
oai:arXiv.org:2005.08765 [pdf] - 2096547
A method to measure superconducting transition temperature of microwave
kinetic inductance detector by changing power of readout microwaves
Submitted: 2020-05-15
A microwave kinetic inductance detector (MKID) is a cutting-edge
superconducting detector, and its principle is based on a superconducting
resonator circuit. The superconducting transition temperature (Tc) of the MKID
is an important parameter because various MKID characterization parameters
depend on it. In this paper, we propose a method to measure the Tc of the MKID
by changing the applied power of the readout microwaves. A small fraction of
the readout power is deposited in the MKID, and the number of quasiparticles in
the MKID increases with this power. Furthermore, the quasiparticle lifetime
decreases with the number of quasiparticles. Therefore, we can measure the
relation between the quasiparticle lifetime and the detector response by
rapidly varying the readout power. From this relation, we estimate the
intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc,
the physical temperature of the MKID device, and other known parameters. We
obtain Tc by comparing the measured lifetime with that acquired using the
theoretical model. Using an MKID fabricated with aluminum, we demonstrate this
method at a 0.3 K operation. The results are consistent with those obtained by
Tc measured by monitoring the transmittance of the readout microwaves with the
variation in the device temperature. The method proposed in this paper is
applicable to other types, such as a hybrid-type MKID.
[2]
oai:arXiv.org:1907.03403 [pdf] - 1953635
A measurement method for responsivity of microwave kinetic inductance
detector by changing power of readout microwaves
Submitted: 2019-07-08
Superconducting detectors are a modern technology applied in various fields.
The microwave kinetic inductance detector (MKID) is one of cutting-edge
superconducting detector. It is based on the principle of a superconducting
resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the
superconducting resonator, and the intensity of the radiation is detected as a
variation of the resonant condition. Therefore, calibration of the detector
responsivity, i.e., the variation of the resonant phase with respect to the
number of Cooper-pair breaks (quasiparticles), is important. We propose a
method for responsivity calibration. Microwaves used for the detector readout
locally raise the temperature in each resonator, which increases the number of
quasiparticles. Since the magnitude of the temperature rise depends on the
power of readout microwaves, the number of quasiparticles also depends on the
power of microwaves. By changing the power of the readout microwaves, we
simultaneously measure the phase difference and lifetime of quasiparticles. We
calculate the number of quasiparticles from the measured lifetime and by using
a theoretical formula. This measurement yields a relation between the phase
response as a function of the number of quasiparticles. We demonstrate this
responsivity calibration using the MKID maintained at 285mK. We also confirm
consistency between the results obtained using this method and conventional
calibration methods in terms of the accuracy.
[3]
oai:arXiv.org:1801.06987 [pdf] - 1698011
The LiteBIRD Satellite Mission - Sub-Kelvin Instrument
Suzuki, A.;
Ade, P. A. R.;
Akiba, Y.;
Alonso, D.;
Arnold, K.;
Aumont, J.;
Baccigalupi, C.;
Barron, D.;
Basak, S.;
Beckman, S.;
Borrill, J.;
Boulanger, F.;
Bucher, M.;
Calabrese, E.;
Chinone, Y.;
Cho, H-M.;
Cukierman, A.;
Curtis, D. W.;
de Haan, T.;
Dobbs, M.;
Dominjon, A.;
Dotani, T.;
Duband, L.;
Ducout, A.;
Dunkley, J.;
Duval, J. M.;
Elleflot, T.;
Eriksen, H. K.;
Errard, J.;
Fischer, J.;
Fujino, T.;
Funaki, T.;
Fuskeland, U.;
Ganga, K.;
Goeckner-Wald, N.;
Grain, J.;
Halverson, N. W.;
Hamada, T.;
Hasebe, T.;
Hasegawa, M.;
Hattori, K.;
Hattori, M.;
Hayes, L.;
Hazumi, M.;
Hidehira, N.;
Hill, C. A.;
Hilton, G.;
Hubmayr, J.;
Ichiki, K.;
Iida, T.;
Imada, H.;
Inoue, M.;
Inoue, Y.;
D., K.;
Ishino, H.;
Jeong, O.;
Kanai, H.;
Kaneko, D.;
Kashima, S.;
Katayama, N.;
Kawasaki, T.;
Kernasovskiy, S. A.;
Keskitalo, R.;
Kibayashi, A.;
Kida, Y.;
Kimura, K.;
Kisner, T.;
Kohri, K.;
Komatsu, E.;
Komatsu, K.;
Kuo, C. L.;
Kurinsky, N. A.;
Kusaka, A.;
Lazarian, A.;
Lee, A. T.;
Li, D.;
Linder, E.;
Maffei, B.;
Mangilli, A.;
Maki, M.;
Matsumura, T.;
Matsuura, S.;
Meilhan, D.;
Mima, S.;
Minami, Y.;
Mitsuda, K.;
Montier, L.;
Nagai, M.;
Nagasaki, T.;
Nagata, R.;
Nakajima, M.;
Nakamura, S.;
Namikawa, T.;
Naruse, M.;
Nishino, H.;
Nitta, T.;
Noguchi, T.;
Ogawa, H.;
Oguri, S.;
Okada, N.;
Okamoto, A.;
Okamura, T.;
Otani, C.;
Patanchon, G.;
Pisano, G.;
Rebeiz, G.;
Remazeilles, M.;
Richards, P. L.;
Sakai, S.;
Sakurai, Y.;
Sato, Y.;
Sato, N.;
Sawada, M.;
Segawa, Y.;
Sekimoto, Y.;
Seljak, U.;
Sherwin, B. D.;
Shimizu, T.;
Shinozaki, K.;
Stompor, R.;
Sugai, H.;
Sugita, H.;
Suzuki, J.;
Tajima, O.;
Takada, S.;
Takaku, R.;
Takakura, S.;
Takatori, S.;
Tanabe, D.;
Taylor, E.;
Thompson, K. L.;
Thorne, B.;
Tomaru, T.;
Tomida, T.;
Tomita, N.;
Tristram, M.;
Tucker, C.;
Turin, P.;
Tsujimoto, M.;
Uozumi, S.;
Utsunomiya, S.;
Uzawa, Y.;
Vansyngel, F.;
Wehus, I. K.;
Westbrook, B.;
Willer, M.;
Whitehorn, N.;
Yamada, Y.;
Yamamoto, R.;
Yamasaki, N.;
Yamashita, T.;
Yoshida, M.
Submitted: 2018-01-22, last modified: 2018-03-15
Inflation is the leading theory of the first instant of the universe.
Inflation, which postulates that the universe underwent a period of rapid
expansion an instant after its birth, provides convincing explanation for
cosmological observations. Recent advancements in detector technology have
opened opportunities to explore primordial gravitational waves generated by the
inflation through B-mode (divergent-free) polarization pattern embedded in the
Cosmic Microwave Background anisotropies. If detected, these signals would
provide strong evidence for inflation, point to the correct model for
inflation, and open a window to physics at ultra-high energies.
LiteBIRD is a satellite mission with a goal of detecting
degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at
the second Lagrange point with a 400 mm diameter telescope and 2,622 detectors.
It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to
measure and subtract foregrounds.
The U.S. LiteBIRD team is proposing to deliver sub-Kelvin instruments that
include detectors and readout electronics. A lenslet-coupled sinuous antenna
array will cover low-frequency bands (40 GHz to 235 GHz) with four frequency
arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated
horn array will cover high-frequency bands (280 GHz to 402 GHz) with three
types of single frequency detectors. The detectors will be made with Transition
Edge Sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by
an adiabatic demagnetization refrigerator.The TES bolometers will be read out
using digital frequency multiplexing with Superconducting QUantum Interference
Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a
single SQUID amplidier.
We report on the sub-Kelvin instrument design and ongoing developments for
the LiteBIRD mission.
[4]
oai:arXiv.org:1601.06349 [pdf] - 1407089
Observation of gamma ray bursts at ground level under the thunderclouds
Submitted: 2016-01-24, last modified: 2016-05-12
We observed three $\gamma$-ray bursts related to thunderclouds in winter
using the prototype of anti-neutrino detector PANDA made of 360-kg plastic
scintillator deployed at Ohi Power Station at the coastal area of the Japan
Sea. The maximum rate of the events which deposited the energy higher than
$3\,$MeV was $(5.5 \pm 0.1) \times 10^2 {\rm /s}$.
Monte Carlo simulation showed that electrons with approximately monochromatic
energy falling downwards from altitudes of order $100\,$m roughly produced the
observed total energy spectra of the bursts. It is supposed that secondary
cosmic-ray electrons, which act as seed, were accelerated in electric field of
thunderclouds and multiplied by relativistic runaway electron avalanche. We
actually found that the $\gamma$-rays of the bursts entered into the detector
from the direction close to the zenith. The direction stayed constant during
the burst within the detector resolution.
In addition, taking advantage of the delayed coincidence detection of the
detector, we found neutron events in one of the bursts at the maximum rate of
$\sim 14\pm5\,{\rm /s}$.
[5]
oai:arXiv.org:1405.7576 [pdf] - 862855
Sub-Kelvin refrigeration with dry-coolers on a rotating system
Submitted: 2014-05-29, last modified: 2014-07-18
We developed a cryogenic system on a rotating table that achieves sub-Kelvin
conditions. The cryogenic system consists of a helium sorption cooler and a
pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint
connectors for electricity and helium gas circulation enable the coolers to be
operated and maintained with ease. We performed cool-down tests under a
condition of continuous rotation at 20 rpm. We obtained a temperature of 0.23 K
with a holding time of more than 24 hours, thus complying with catalog
specifications. We monitored the system's performance for four weeks; two weeks
with and without rotation. A few-percent difference in conditions was observed
between these two states. Most applications can tolerate such a slight
difference. The technology developed is useful for various scientific
applications requiring sub-Kelvin conditions on rotating platforms.
[6]
oai:arXiv.org:1311.2847 [pdf] - 855791
Mission design of LiteBIRD
Matsumura, T.;
Akiba, Y.;
Borrill, J.;
Chinone, Y.;
Dobbs, M.;
Fuke, H.;
Ghribi, A.;
Hasegawa, M.;
Hattori, K.;
Hattori, M.;
Hazumi, M.;
Holzapfel, W.;
Inoue, Y.;
Ishidoshiro, K.;
Ishino, H.;
Ishitsuka, H.;
Karatsu, K.;
Katayama, N.;
Kawano, I.;
Kibayashi, A.;
Kibe, Y.;
Kimura, K.;
Kimura, N.;
Koga, K.;
Kozu, M.;
Komatsu, E.;
Lee, A.;
Matsuhara, H.;
Mima, S.;
Mitsuda, K.;
Mizukami, K.;
Morii, H.;
Morishima, T.;
Murayama, S.;
Nagai, M.;
Nagata, R.;
Nakamura, S.;
Naruse, M.;
Natsume, K.;
Nishibori, T.;
Nishino, H.;
Noda, A.;
Noguchi, T.;
Ogawa, H.;
Oguri, S.;
Ohta, I.;
Otani, C.;
Richards, P.;
Sakai, S.;
Sato, N.;
Sato, Y.;
Sekimoto, Y.;
Shimizu, A.;
Shinozaki, K.;
Sugita, H.;
Suzuki, T.;
Suzuki, A.;
Tajima, O.;
Takada, S.;
Takakura, S.;
Takei, Y.;
Tomaru, T.;
Uzawa, Y.;
Wada, T.;
Watanabe, H.;
Yamasaki, N.;
Yoshida, M.;
Yoshida, T.;
Yotsumoto, K.
Submitted: 2013-11-12
LiteBIRD is a next-generation satellite mission to measure the polarization
of the cosmic microwave background (CMB) radiation. On large angular scales the
B-mode polarization of the CMB carries the imprint of primordial gravitational
waves, and its precise measurement would provide a powerful probe of the epoch
of inflation. The goal of LiteBIRD is to achieve a measurement of the
characterizing tensor to scalar ratio $r$ to an uncertainty of $\delta
r=0.001$. In order to achieve this goal we will employ a kilo-pixel
superconducting detector array on a cryogenically cooled sub-Kelvin focal plane
with an optical system at a temperature of 4~K. We are currently considering
two detector array options; transition edge sensor (TES) bolometers and
microwave kinetic inductance detectors (MKID). In this paper we give an
overview of LiteBIRD and describe a TES-based polarimeter designed to achieve
the target sensitivity of 2~$\mu$K$\cdot$arcmin over the frequency range 50 to
320~GHz.
[7]
oai:arXiv.org:1306.5040 [pdf] - 853614
Radio-transparent multi-layer insulation for radiowave receivers
Submitted: 2013-06-20, last modified: 2013-10-18
In the field of radiowave detection, enlarging the receiver aperture to
enhance the amount of light detected is essential for greater scientific
achievements. One challenge in using radio transmittable apertures is keeping
the detectors cool. This is because transparency to thermal radiation above the
radio frequency range increases the thermal load. A technology that maintains
cold conditions while allowing larger apertures has been long-awaited. We
propose radio-transparent multi-layer insulation (RT-MLI), composed from a set
of stacked insulating layers. The insulator is transparent to radio
frequencies, but not transparent to infrared radiation. The basic idea for
cooling is similar to conventional multi-layer insulation. It leads to a
reduction in thermal radiation while maintaining a uniform surface temperature.
The advantage of this technique over other filter types is that no thermal
links are required. As insulator material, we used foamed polystyrene; its low
index of refraction makes an anti-reflection coating unnecessary. We measured
the basic performance of RT-MLI to confirm that thermal loads are lowered with
more layers. We also confirmed that our RT-MLI has high transmittance to
radiowaves, but blocks infrared radiation. For example, RT-MLI with 12 layers
has a transmittance greater than 95% (lower than 1%) below 200 GHz (above 4
THz). We demonstrated its effects in a system with absorptive-type filters,
where aperture diameters were 200 mm. Low temperatures were successfully
maintained for the filters. We conclude that this technology significantly
enhances the cooling of radiowave receivers, and is particularly suitable for
large-aperture systems. This technology is expected to be applicable to various
fields, including radio astronomy, geo-environmental assessment, and radar
systems.
[8]
oai:arXiv.org:1303.5207 [pdf] - 853612
Cryogenic cooling with cryocooler on a rotating system
Submitted: 2013-03-21, last modified: 2013-05-12
We developed a system that continuously maintains a cryocooler for long
periods on a rotating table. A cryostat that holds the cryocooler is set on the
table. A compressor is located on the ground and supplies high-purity (>
99.999%) and high-pressure (1.7 MPa) helium gas and electricity to the
cryocooler. The operation of the cryocooler and other instruments requires the
development of interface components between the ground and rotating table. A
combination of access holes at the center of the table and two rotary joints
allows simultaneous circulation of electricity and helium gas. The developed
system provides two innovative functions under the rotating condition; cooling
from room temperature and the maintenance of a cold condition for long periods.
We have confirmed these abilities as well as temperature stability under a
condition of continuous rotation at 20 revolutions per minute. The developed
system can be applied in various fields; e.g., in tests of Lorentz invariance,
searches for axion, radio astronomy and cosmology, and application of radar
systems. In particular, there is a plan to use this system for a radio
telescope observing cosmic microwave background radiation.
[9]
oai:arXiv.org:1007.4750 [pdf] - 457304
Pulse-Shape Discrimination of CaF2(Eu)
Submitted: 2010-07-27, last modified: 2010-07-28
We measured the decay time of the scintillation pulses produced by electron
and nuclear recoils in CaF2(Eu) by a new fitting method. In the recoil energy
region 5-30 keVee, we found differences of the decay time between electron and
nuclear recoil events. In the recoil energy region above 20 keVee, we found
that the decay time is independent of the recoil energy.