Normalized to: Occhipinti, G.
[1]
oai:arXiv.org:1909.12149 [pdf] - 2041274
First detection of the Crab Nebula at TeV energies with a Cherenkov
telescope in a dual-mirror Schwarzschild-Couder configuration: the ASTRI-Horn
telescope
Lombardi, S.;
Catalano, O.;
Scuderi, S.;
Antonelli, L. A.;
Pareschi, G.;
Antolini, E.;
Arrabito, L.;
Bellassai, G.;
Bernloehr, K.;
Bigongiari, C.;
Biondo, B.;
Bonanno, G.;
Bonnoli, G.;
Bottcher, G. M.;
Bregeon, J.;
Bruno, P.;
Canestrari, R.;
Capalbi, M.;
Caraveo, P.;
Conconi, P.;
Conforti, V.;
Contino, G.;
Cusumano, G.;
Pino, M. de Gouveia Dal;
Distefano, A.;
Farisato, G.;
Fermino, C.;
Fiorini, M.;
Frigo, A.;
Gallozzi, S.;
Gargano, C.;
Garozzo, S.;
Gianotti, F.;
Giarrusso, S.;
Gimenes, R.;
Giro, E.;
Grillo, A.;
Impiombato, D.;
Incorvaia, S.;
La Palombara, N.;
La Parola, V.;
La Rosa, G.;
Leto, G.;
Lucarelli, F.;
Maccarone, M. C.;
Marano, D.;
Martinetti, E.;
Micciche, A.;
Millul, R.;
Mineo, T.;
Nicotra, G.;
Occhipinti, G.;
Pagano, I.;
Perri, M.;
Romeo, G.;
Russo, F.;
Russo, F.;
Sacco, B.;
Sangiorgi, P.;
Saturni, F. G.;
Segreto, A.;
Sironi, G.;
Sottile, G.;
Stamerra, A.;
Stringhetti, L.;
Tagliaferri, G.;
Tavani, M.;
Testa, V.;
Timpanaro, M. C.;
Toso, G.;
Tosti, G.;
Trifoglio, M.;
Umana, G.;
Vercellone, S.;
Sanchez, R. Zanmar;
Arcaro, C.;
Bulgarelli, A.;
Cardillo, M.;
Cascone, E.;
Costa, A.;
D'Ai, A.;
D'Ammando, F.;
Del Santo, M.;
Fioretti, V.;
Lamastra, A.;
Mereghetti, S.;
Pintore, F.;
Rodeghiero, G.;
Romano, P.;
Schwarz, J.;
Sciacca, E.;
Vitello, F. R.;
Wolter, A.
Submitted: 2019-09-26, last modified: 2020-02-03
We report on the first detection of very high-energy (VHE) gamma-ray emission
from the Crab Nebula by a Cherenkov telescope in dual-mirror
Schwarzschild-Couder (SC) configuration. The result has been achieved by means
of the 4 m size ASTRI-Horn telescope, operated on Mt. Etna (Italy) and
developed in the context of the Cherenkov Telescope Array Observatory
preparatory phase. The dual-mirror SC design is aplanatic and characterized by
a small plate scale, allowing us to implement large field of view cameras with
small-size pixel sensors and a high compactness. The curved focal plane of the
ASTRI camera is covered by silicon photo-multipliers (SiPMs), managed by an
unconventional front-end electronics based on a customized peak-sensing
detector mode. The system includes internal and external calibration systems,
hardware and software for control and acquisition, and the complete data
archiving and processing chain. The observations of the Crab Nebula were
carried out in December 2018, during the telescope verification phase, for a
total observation time (after data selection) of 24.4 h, equally divided into
on- and off-axis source exposure. The camera system was still under
commissioning and its functionality was not yet completely exploited.
Furthermore, due to recent eruptions of the Etna Volcano, the mirror reflection
efficiency was reduced. Nevertheless, the observations led to the detection of
the source with a statistical significance of 5.4 sigma above an energy
threshold of ~3 TeV. This result provides an important step towards the use of
dual-mirror systems in Cherenkov gamma-ray astronomy. A pathfinder mini-array
based on nine large field-of-view ASTRI-like telescopes is under
implementation.
[2]
oai:arXiv.org:1912.07543 [pdf] - 2015227
Characterization method to achieve simultaneous absolute PDE
measurements of all pixels of an ASTRI Mini-Array camera tile
Submitted: 2019-12-13
Recently, the Istituto Nazionale di Astrofisica (INAF) has placed a contract
with Hamamatsu Photonics to acquire hundreds of Silicon Photomultipliers (SiPM)
tiles to build 10 cameras with 37 tiles each for the ASTRI Mini-Array (MA)
project. Each tile is made up of 8x8 pixels of 7x7 mm2 with micro-cells of
75um. To check the quality of the delivered tiles a complex and acurate test
plan has been studied. The possibility to simultaneously analyse as many pixels
as possible becomes of crucial im-portance. Dark Count Rate (DCR) versus
over-voltage and versus temperature and Optical Cross Talk (OCT) versus
over-voltage can be easily measured simultaneously for all pixels because they
are carried out in dark conditions. On the contrary, simultaneous Photon
Detection Efficiency (PDE) measurement of all pixels of a tile is not easily
achievable and needs an appropriate optical set-up. Simultaneous measurements
have the advantage of speeding up the entire procedure and enabling quick PDE
compari-son of all the tile pixels. The paper describes the preliminary steps
to guarantee an accurate absolute PDE measurement and the investigation the
capa-bility of the electronics to obtain simultaneous PDE measurements. It also
demonstrates the possibility of using a calibrated SiPM as reference detector
instead of a calibrated photodiode. The method to achieve accurate absolute PDE
of four central pixels of a tile is also described.