sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Oberlack, U.

Normalized to: Oberlack, U.

84 article(s) in total. 1029 co-authors, from 1 to 59 common article(s). Median position in authors list is 27,5.

[1]  oai:arXiv.org:2006.09721  [pdf] - 2124928
Observation of Excess Electronic Recoil Events in XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Angevaare, J. R.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Cimmino, B.; Clark, M.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; Depoian, A.; Di Gangi, P.; Di Giovanni, A.; Di Stefano, R.; Diglio, S.; Elykov, A.; Eurin, G.; Ferella, A. D.; Fulgione, W.; Gaemers, P.; Gaior, R.; Galloway, M.; Gao, F.; Grandi, L.; Hasterok, C.; Hils, C.; Hiraide, K.; Hoetzsch, L.; Howlett, J.; Iacovacci, M.; Itow, Y.; Joerg, F.; Kato, N.; Kazama, S.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Long, J.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Mancuso, A.; Manenti, L.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Martens, K.; Masbou, J.; Masson, D.; Mastroianni, S.; Messina, M.; Miuchi, K.; Mizukoshi, K.; Molinario, A.; Morå, K.; Moriyama, S.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Plante, G.; Qin, J.; Qiu, H.; García, D. Ramírez; Reichard, S.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Semeria, F.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Takeda, A.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Vargas, M.; Volta, G.; Wang, H.; Wei, Y.; Weinheimer, C.; Weiss, M.; Wenz, D.; Wittweg, C.; Xu, Z.; Yamashita, M.; Ye, J.; Zavattini, G.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.; Mougeot, X.
Comments: 24 pages, 15 figures, v2 added Ar37 background discussion and best-fit mass of bosonic dark matter, data upload fig 2,4,15 in 10.5281/zenodo.3924406
Submitted: 2020-06-17, last modified: 2020-06-30
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector, with an exposure of 0.65 t-y and an unprecedentedly low background rate of $76 \pm 2_{stat}$ events/(t y keV) between 1-30 keV. An excess over known backgrounds is observed below 7 keV, rising towards lower energies and prominent between 2-3 keV. The solar axion model has a 3.5$\sigma$ significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae} < 3.7 \times 10^{-12}$, $g_{ae}g_{an}^{eff} < 4.6 \times 10^{-18}$, and $g_{ae}g_{a\gamma} < 7.6\times10^{-22}~{GeV}^{-1}$, and excludes either $g_{ae}=0$ or $g_{ae}g_{a\gamma}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic moment signal is similarly favored over background at 3.2$\sigma$ and a confidence interval of $\mu_{\nu} \in (1.4,~2.9)\times10^{-11}\mu_B$ (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by $\beta$ decays of tritium at 3.2$\sigma$ significance with a corresponding tritium concentration in xenon of $(6.2 \pm 2.0) \times 10^{-25}$ mol/mol. Such a trace amount can be neither confirmed nor excluded with current knowledge of production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to 2.1$\sigma$ and 0.9$\sigma$, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ($2.3 \pm 0.2$) keV (68% C.L.) with a 3.0$\sigma$ global (4.0$\sigma$ local) significance over background. This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and 210 keV/c$^2$.
[2]  oai:arXiv.org:2006.03114  [pdf] - 2109247
Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering
Aalbers, J.; Agostini, F.; Maouloud, S. E. M. Ahmed; Alfonsi, M.; Althueser, L.; Amaro, F.; Angevaare, J.; Antochi, V. C.; Antunovic, B.; Aprile, E.; Arazi, L.; Arneodo, F.; Balzer, M.; Baudis, L.; Baur, D.; Benabderrahmane, M. L.; Biondi, Y.; Bismark, A.; Bourgeois, C.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruno, G.; Brünner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J.; Cichon, D.; Clark, M.; Colijn, A. P.; Conrad, J.; Cuenca-García, J. J.; Cussonneau, J. P.; Decowski, M. P.; Depoian, A.; Dierle, J.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Douillet, D.; Drexlin, G.; Eitel, K.; Engel, R.; Erdal, E.; Ferella, A. D.; Fischer, H.; Fischer, P.; Fulgione, W.; Gaemers, P.; Galloway, M.; Gao, F.; Giovagnoli, D.; Girard, F.; Glade-Beucke, R.; Glück, F.; Grandi, L.; Grohmann, S.; Größle, R.; Gumbsheimer, R.; Hannen, V.; Hansmann-Menzemer, S.; Hils, C.; Holzapfel, B.; Howlett, J.; Iaquaniello, G.; Jörg, F.; Keller, M.; Kellerer, J.; Khundzakishvili, G.; Kilminster, B.; Kleifges, M.; Kleiner, T. K.; Koltmann, G.; Kopec, A.; Kopmann, A.; Krauss, L. M.; Kuger, F.; LaCascio, L.; Landsman, H.; Lang, R. F.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Villalpando, A. Loya; Ma, Y.; Macolino, C.; Mahlstedt, J.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Masson, D.; Masson, E.; McFadden, N.; Meinhardt, P.; Meyer, R.; Milosevic, B.; Milutinovic, S.; Molinario, A.; Monteiro, C. M. B.; Morå, K.; Morteau, E.; Mosbacher, Y.; Murra, M.; Newstead, J. L.; Ni, K.; Oberlack, U. G.; Obradovic, M.; Odgers, K.; Ostrovskiy, I.; Palacio, J.; Pandurovic, M.; Pelssers, B.; Peres, R.; Pienaar, J.; Pierre, M.; Pizzella, V.; Plante, G.; Qi, J.; Qin, J.; García, D. Ramírez; Reichard, S. E.; Rupp, N.; Sanchez-Lucas, P.; Santos, J.; Sartorelli, G.; Schulte, D.; Schultz-Coulon, H. -C.; Eißing, H. Schulze; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Sharma, S.; Shen, W.; Silva, M.; Simgen, H.; Steidl, M.; Stern, S.; Subotic, D.; Szabo, P.; Terliuk, A.; Therreau, C.; Thers, D.; Thieme, K.; Toennies, F.; Trotta, R.; Tunnell, C. D.; Valerius, K.; Volta, G.; Vorkapic, D.; Weber, M.; Wei, Y.; Weinheimer, C.; Weiss, M.; Wenz, D.; Wittweg, C.; Wolf, J.; Wuestling, S.; Wurm, M.; Xing, Y.; Zhu, T.; Zhu, Y.; Zopounidis, J. P.; Zuber, K.
Comments: 9 pages, 4 figures; for associated data files, see https://github.com/Physik-Institut-UZH/DARWIN-Sensitivity-Studies/tree/master/solar_neutrinos_electron_scattering
Submitted: 2020-06-04
We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would benefit from a depleted target. A high-statistics observation of $pp$ neutrinos would allow us to infer the values of the weak mixing angle, $\sin^2\theta_w$, and the electron-type neutrino survival probability, $P_e$, in the electron recoil energy region from a few keV up to 200 keV for the first time, with relative precision of 5% and 4%, respectively, at an exposure of 300 ty. An observation of $pp$ and $^7$Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high (GS98) and low metallicity (AGS09) solar models with 2.1-2.5$\sigma$ significance, independent of external measurements from other experiments or a measurement of $^8$B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of $^{131}$Xe.
[3]  oai:arXiv.org:2003.03825  [pdf] - 2060953
Energy resolution and linearity in the keV to MeV range measured in XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Angevaare, J.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Cimmino, B.; Clark, M.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; Di Stefano, A. Depoian P. Di Gangi A. Di Giovanni R.; Diglio, S.; Elykov, A.; Eurin, G.; Ferella, A. D.; Fulgione, W.; Gaemers, P.; Gaior, R.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Hasterok, C.; Hils, C.; Hiraide, K.; Hoetzsch, L.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itow, Y.; Joerg, F.; Kato, N.; Kazama, S.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Manenti, L.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Martens, K.; Masbou, J.; Masson, D.; Mastroianni, S.; Messina, M.; Miuchi, K.; Molinario, A.; Morå, K.; Moriyama, S.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Qin, G. Plante J.; Qiu, H.; García, D. Ramírez; Reichard, S.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Semeria, F.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Takeda, A.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Vargas, M.; Volta, G.; Wack, O.; Wang, H.; Wei, Y.; Weinheimer, C.; Xu, M. Weiss; Wenz, D.; Wittweg, C.; Wulf, J.; Xu, Z.; Yamashita, M.; Ye, J.; Zavattini, G.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.
Comments: 9 pages, 7 figures
Submitted: 2020-03-08
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{\beta\beta}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $\sigma/\mu$ is as low as (0.79$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{\beta\beta}$. We achieve this by using a signal correction method to rectify the saturation effects of the signal readout system. The very good energy resolution from keV to MeV energies demonstrated in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
[4]  oai:arXiv.org:1907.12771  [pdf] - 2021183
Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Depoian, A.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Elykov, A.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Gaemers, P.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Greene, Z.; Hasterok, C.; Hils, C.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itay, R.; Joerg, F.; Kazama, S.; Kish, A.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Manenti, L.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Masbou, J.; Mastroianni, S.; Messina, M.; Micheneau, K.; Miller, K.; Molinario, A.; Morå, K.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Plante, G.; Podviianiuk, R.; Qin, J.; Qiu, H.; García, D. Ramírez; Reichard, S.; Riedel, B.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Volta, G.; Wack, O.; Wang, H.; Wei, Y.; Weinheimer, C.; Wenz, D.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.
Comments:
Submitted: 2019-07-30, last modified: 2019-12-24
Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.
[5]  oai:arXiv.org:1907.11485  [pdf] - 2015750
Light Dark Matter Search with Ionization Signals in XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Depoian, A.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Elykov, A.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Gaemers, P.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Greene, Z.; Hasterok, C.; Hils, C.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itay, R.; Joerg, F.; Kazama, S.; Kish, A.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Masbou, J.; Mastroianni, S.; Messina, M.; Micheneau, K.; Miller, K.; Molinario, A.; Morå, K.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Plante, G.; Podviianiuk, R.; Qin, J.; Qiu, H.; García, D. Ramírez; Reichard, S.; Riedel, B.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Volta, G.; Wack, O.; Wang, H.; Wei, Y.; Weinheimer, C.; Wenz, D.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.
Comments:
Submitted: 2019-07-26, last modified: 2019-12-17
We report constraints on light dark matter (DM) models using ionization signals in the XENON1T experiment. We mitigate backgrounds with strong event selections, rather than requiring a scintillation signal, leaving an effective exposure of $(22 \pm 3)$ tonne-days. Above $\sim\!0.4\,\mathrm{keV}_\mathrm{ee}$, we observe $<1 \, \text{event}/(\text{tonne} \times \text{day} \times \text{keV}_\text{ee})$, which is more than one thousand times lower than in similar searches with other detectors. Despite observing a higher rate at lower energies, no DM or CEvNS detection may be claimed because we cannot model all of our backgrounds. We thus exclude new regions in the parameter spaces for DM-nucleus scattering for DM masses $m_\chi$ within $3-6\,\mathrm{GeV}/\mathrm{c}^2$, DM-electron scattering for $m_\chi > 30\,\mathrm{MeV}/\mathrm{c}^2$, and absorption of dark photons and axion-like particles for $m_\chi$ within $0.186 - 1 \, \mathrm{keV}/\mathrm{c}^2$.
[6]  oai:arXiv.org:1907.07558  [pdf] - 2005454
All-sky Medium Energy Gamma-ray Observatory: Exploring the Extreme Multimessenger Universe
McEnery, Julie; Barrio, Juan Abel; Agudo, Ivan; Ajello, Marco; Álvarez, José-Manuel; Ansoldi, Stefano; Anton, Sonia; Auricchio, Natalia; Stephen, John B.; Baldini, Luca; Bambi, Cosimo; Baring, Matthew; Barres, Ulisses; Bastieri, Denis; Beacom, John; Beckmann, Volker; Bednarek, Wlodek; Bernard, Denis; Bissaldi, Elisabetta; Bloser, Peter; Blumer, Harsha; Boettcher, Markus; Boggs, Steven; Bolotnikov, Aleksey; Bottacini, Eugenio; Bozhilov, Vladimir; Bozzo, Enrico; Briggs, Michael; Buckley, Jim; Burns, Eric; Buson, Sara; Campana, Riccardo; Caputo, Regina; Cardillo, Martina; Caroli, Ezio; Castro, Daniel; Cenko, S. Brad; Charles, Eric; Chen, Wenlei; Cheung, Teddy; Ciprini, Stefano; Coppi, Paolo; da Silva, Rui Curado; Cutini, Sara; D'Ammando, Filippo; De Angelis, Alessandro; De Becker, Michaël; De Nolfo, Georgia; Del Sordo, Stefano; Di Mauro, Mattia; Di Venere, Leonardo; Dietrich, Stefano; Digel, Seth; Dominguez, Alberto; Doro, Michele; Ferrara, Elizabeth; Fields, Brian; Finke, Justin; Foffano, Luca; Fryer, Chris; Fukazawa, Yasushi; Funk, Stefan; Gasparrini, Dario; Gelfand, Joseph; Georganopoulos, Markos; Giordano, Francesco; Giuliani, Andrea; Gouiffes, Christian; Grefenstette, Brian; Grenier, Isabelle; Griffin, Sean; Grove, Eric; Guiriec, Sylvain; Harding, Alice; Harding, Pat; Hartmann, Dieter; Hays, Elizabeth; Hernanz, Margarita; Hewitt, Jack; Holder, Jamie; Hui, Michelle; Inglis, Andrew; Johnson, Robert; Jones, Sam; Kanbach, Gottfried; Kargaltsev, Oleg; Kaufmann, Sarah; Kerr, Matthew; Kierans, Carolyn; Kislat, Fabian; Klimenko, Alexei V.; Knodlseder, Jurgen; Kocveski, Daniel; Kopp, Joachim; Krawczynsiki, Henric; Krizmanic, John; Kubo, Hidetoshi; Neilson, Naoko Kurahashi; Laurent, Philippe; Lenain, Jean-Philippe; Li, Hui; Lien, Amy; Linden, Tim; Lommler, Jan; Longo, Francesco; Lovellette, Michael; López, Marcos; Manousakis, Antonios; Marcotulli, Lea; Marcowith, Alexandre; Martinez, Manel; McConnell, Marc; Metcalfe, Jessica; Meyer, Eileen; Meyer, Manuel; Mignani, Roberto; Mitchell, John; Mizuno, Tsunefumi; Moiseev, Alexander; Morcuende, Daniel; Moskalenko, Igor; Moss, Michael; Nakazawa, Kazuhiro; Mazziotta, M. Nicola; Oberlack, Uwe; Ohno, Masanori; Oikonomou, Foteini; Ojha, Roopesh; Omodei, Nicola; Orlando, Elena; Otte, Nepomuk; Paliya, Vaidehi S; Parker, Lucas; Patricelli, Barbara; Perkins, Jeremy; Petropoulou, Maria; Pittori, Carlotta; Pohl, Martin; Porter, Troy; Prandini, Elisa; Prescod-Weinstein, Chanda; Racusin, Judith; Rando, Riccardo; Rani, Bindu; Ribó, Marc; Rodi, James; Sanchez-Conde, Miguel A.; Parkinson, Pablo Saz; Schirato, Richard; Shawhan, Peter; Shrader, Chris; Smith, Jacob; Smith, Karl; Stamerra, Antonio; Stawarz, Lukasz; Strong, Andy; Stumke, Inga; Tajima, Hiro; Takahashi, Hiromitsu; Tanaka, Yasuyuki; Tatischeff, Vincent; The, Lih-Sin; Thompson, David; Tibaldo, Luigi; Tomsick, John; Uhm, Lucas; Venters, Tonia; Vestrand, Tom; Vianello, Giacomo; Wadiasingh, Zorawar; Walter, Roland; Wang, Xilu; Williams, David; Wilson-Hodge, Colleen; Wood, Matthew; Woolf, Richard; Wulf, Eric; Younes, George; Zampieri, Luca; Zane, Silvia; Zhang, Bing; Zhang, Haocheng; Zimmer, Stephan; Zoglauer, Andreas; van der Horst, Alexander
Comments: Astro2020 APC White Paper Updated to make small change to author list in metadata
Submitted: 2019-07-17, last modified: 2019-11-25
The All-sky Medium Energy Gamma-ray Observatory (AMEGO) is a probe class mission concept that will provide essential contributions to multimessenger astrophysics in the late 2020s and beyond. AMEGO combines high sensitivity in the 200 keV to 10 GeV energy range with a wide field of view, good spectral resolution, and polarization sensitivity. Therefore, AMEGO is key in the study of multimessenger astrophysical objects that have unique signatures in the gamma-ray regime, such as neutron star mergers, supernovae, and flaring active galactic nuclei. The order-of-magnitude improvement compared to previous MeV missions also enables discoveries of a wide range of phenomena whose energy output peaks in the relatively unexplored medium-energy gamma-ray band.
[7]  oai:arXiv.org:1905.07806  [pdf] - 1885724
All-Sky-ASTROGAM: The MeV Gamma-Ray Companion to Multimessenger Astronomy
Comments: 6 pages, 5 figures, proceedings of the 12th INTEGRAL conference "INTEGRAL looks AHEAD to Multimessenger astronomy" in Geneva (Switzerland) on 11-15 February 2019
Submitted: 2019-05-19
All-Sky-ASTROGAM is a gamma-ray observatory operating in a broad energy range, 100 keV to a few hundred MeV, recently proposed as the "Fast" (F) mission of the European Space Agency for a launch in 2028 to an L2 orbit. The scientific payload is composed of a unique gamma-ray imaging monitor for astrophysical transients, with very large field of view (almost 4$\pi$ sr) and optimal sensitivity to detect bright and intermediate flux sources (gamma-ray bursts, active galactic nuclei, X-ray binaries, supernovae and novae) at different timescales ranging from seconds to months. The mission will operate in a maturing gravitational wave and multi-messenger epoch, opening up new and exciting synergies.
[8]  oai:arXiv.org:1902.03234  [pdf] - 1875324
Constraining the Spin-Dependent WIMP-Nucleon Cross Sections with XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Anthony, M.; Antochi, V. C.; Arneodo, F.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Elykov, A.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Greene, Z.; Hasterok, C.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itay, R.; Joerg, F.; Kazama, S.; Kish, A.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Masbou, J.; Masson, D.; Mastroianni, S.; Messina, M.; Micheneau, K.; Miller, K.; Molinario, A.; Morå, K.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Pelssers, B.; Piastra, F.; Pienaar, J.; Pizzella, V.; Plante, G.; Podviianiuk, R.; Priel, N.; Qiu, H.; García, D. Ramírez; Reichard, S.; Riedel, B.; Rizzo, A.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wenz, D.; Wittweg, C.; Wulf, J.; Xu, Z.; Ye, J.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.
Comments:
Submitted: 2019-02-08, last modified: 2019-04-30
We report the first experimental results on spin-dependent elastic weakly interacting massive particle (WIMP) nucleon scattering from the XENON1T dark matter search experiment. The analysis uses the full ton year exposure of XENON1T to constrain the spin-dependent proton-only and neutron-only cases. No significant signal excess is observed, and a profile likelihood ratio analysis is used to set exclusion limits on the WIMP-nucleon interactions. This includes the most stringent constraint to date on the WIMP-neutron cross section, with a minimum of $6.3\times10^{-42}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level. The results are compared with those from collider searches and used to exclude new parameter space in an isoscalar theory with an axial-vector mediator.
[9]  oai:arXiv.org:1903.05569  [pdf] - 1848688
Positron Annihilation in the Galaxy
Comments: 10 pages including 3 figures. Science White paper submitted to Astro2020
Submitted: 2019-03-13
The 511 keV line from positron annihilation in the Galaxy was the first $\gamma$-ray line detected to originate from outside our solar system. Going into the fifth decade since the discovery, the source of positrons is still unconfirmed and remains one of the enduring mysteries in $\gamma$-ray astronomy. With a large flux of $\sim$10$^{-3}$ $\gamma$/cm$^{2}$/s, after 15 years in operation INTEGRAL/SPI has detected the 511 keV line at $>50\sigma$ and has performed high-resolution spectral studies which conclude that Galactic positrons predominantly annihilate at low energies in warm phases of the interstellar medium. The results from imaging are less certain, but show a spatial distribution with a strong concentration in the center of the Galaxy. The observed emission from the Galactic disk has low surface brightness and the scale height is poorly constrained, therefore, the shear number of annihilating positrons in our Galaxy is still not well know. Positrons produced in $\beta^+$-decay of nucleosynthesis products, such as $^{26}$Al, can account for some of the annihilation emission in the disk, but the observed spatial distribution, in particular the excess in the Galactic bulge, remains difficult to explain. Additionally, one of the largest uncertainties in these studies is the unknown distance that positrons propagate before annihilation. In this paper, we will summarize the current knowledge base of Galactic positrons, and discuss how next-generation instruments could finally provide the answers.
[10]  oai:arXiv.org:1811.12482  [pdf] - 1836537
First results on the scalar WIMP-pion coupling, using the XENON1T experiment
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Anthony, M.; Antochi, V. C.; Arneodo, F.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Elykov, A.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Greene, Z.; Hasterok, C.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itay, R.; Joerg, F.; Kaminsky, B.; Kazama, S.; Kish, A.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Masbou, J.; Masson, D.; Mastroianni, S.; Messina, M.; Micheneau, K.; Miller, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Pelssers, B.; Piastra, F.; Pienaar, J.; Pizzella, V.; Plante, G.; Podviianiuk, R.; Priel, N.; Qiu, H.; García, D. Ramírez; Reichard, S.; Riedel, B.; Rizzo, A.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.; Hoferichter, M.; Klos, P.; Menéndez, J.; Schwenk, A.
Comments:
Submitted: 2018-11-29, last modified: 2019-02-22
We present first results on the scalar WIMP-pion coupling from 1 t$\times$yr of exposure with the XENON1T experiment. This interaction is generated when the WIMP couples to a virtual pion exchanged between the nucleons in a nucleus. In contrast to most non-relativistic operators, these pion-exchange currents can be coherently enhanced by the total number of nucleons, and therefore may dominate in scenarios where spin-independent WIMP-nucleon interactions are suppressed. Moreover, for natural values of the couplings, they dominate over the spin-dependent channel due to their coherence in the nucleus. Using the signal model of this new WIMP-pion channel, no significant excess is found, leading to an upper limit cross section of $6.4\times10^{-46}$ cm$^2$ (90 % confidence level) at 30 GeV/c$^2$ WIMP mass.
[11]  oai:arXiv.org:1902.02915  [pdf] - 1828935
Catching Element Formation In The Act
Fryer, Chris L.; Timmes, Frank; Hungerford, Aimee L.; Couture, Aaron; Adams, Fred; Aoki, Wako; Arcones, Almudena; Arnett, David; Auchettl, Katie; Avila, Melina; Badenes, Carles; Baron, Eddie; Bauswein, Andreas; Beacom, John; Blackmon, Jeff; Blondin, Stephane; Bloser, Peter; Boggs, Steve; Boss, Alan; Brandt, Terri; Bravo, Eduardo; Brown, Ed; Brown, Peter; Budtz-Jorgensen, Steve Bruenn. Carl; Burns, Eric; Calder, Alan; Caputo, Regina; Champagne, Art; Chevalier, Roger; Chieffi, Alessandro; Chipps, Kelly; Cinabro, David; Clarkson, Ondrea; Clayton, Don; Coc, Alain; Connolly, Devin; Conroy, Charlie; Cote, Benoit; Couch, Sean; Dauphas, Nicolas; deBoer, Richard James; Deibel, Catherine; Denisenkov, Pavel; Desch, Steve; Dessart, Luc; Diehl, Roland; Doherty, Carolyn; Dominguez, Inma; Dong, Subo; Dwarkadas, Vikram; Fan, Doreen; Fields, Brian; Fields, Carl; Filippenko, Alex; Fisher, Robert; Foucart, Francois; Fransson, Claes; Frohlich, Carla; Fuller, George; Gibson, Brad; Giryanskaya, Viktoriya; Gorres, Joachim; Goriely, Stephane; Grebenev, Sergei; Grefenstette, Brian; Grohs, Evan; Guillochon, James; Harpole, Alice; Harris, Chelsea; Harris, J. Austin; Harrison, Fiona; Hartmann, Dieter; Hashimoto, Masa-aki; Heger, Alexander; Hernanz, Margarita; Herwig, Falk; Hirschi, Raphael; Hix, Raphael William; Hoflich, Peter; Hoffman, Robert; Holcomb, Cole; Hsiao, Eric; Iliadis, Christian; Janiuk, Agnieszka; Janka, Thomas; Jerkstrand, Anders; Johns, Lucas; Jones, Samuel; Jose, Jordi; Kajino, Toshitaka; Karakas, Amanda; Karpov, Platon; Kasen, Dan; Kierans, Carolyn; Kippen, Marc; Korobkin, Oleg; Kobayashi, Chiaki; Kozma, Cecilia; Krot, Saha; Kumar, Pawan; Kuvvetli, Irfan; Laird, Alison; Laming, Martin; Larsson, Josefin; Lattanzio, John; Lattimer, James; Leising, Mark; Lennarz, Annika; Lentz, Eric; Limongi, Marco; Lippuner, Jonas; Livne, Eli; Lloyd-Ronning, Nicole; Longland, Richard; Lopez, Laura A.; Lugaro, Maria; Lutovinov, Alexander; Madsen, Kristin; Malone, Chris; Matteucci, Francesca; McEnery, Julie; Meisel, Zach; Messer, Bronson; Metzger, Brian; Meyer, Bradley; Meynet, Georges; Mezzacappa, Anthony; Miller, Jonah; Miller, Richard; Milne, Peter; Misch, Wendell; Mitchell, Lee; Mosta, Philipp; Motizuki, Yuko; Muller, Bernhard; Mumpower, Matthew; Murphy, Jeremiah; Nagataki, Shigehiro; Nakar, Ehud; Nomoto, Ken'ichi; Nugent, Peter; Nunes, Filomena; O'Shea, Brian; Oberlack, Uwe; Pain, Steven; Parker, Lucas; Perego, Albino; Pignatari, Marco; Pinedo, Gabriel Martinez; Plewa, Tomasz; Poznanski, Dovi; Priedhorsky, William; Pritychenko, Boris; Radice, David; Ramirez-Ruiz, Enrico; Rauscher, Thomas; Reddy, Sanjay; Rehm, Ernst; Reifarth, Rene; Richman, Debra; Ricker, Paul; Rijal, Nabin; Roberts, Luke; Ropke, Friedrich; Rosswog, Stephan; Ruiter, Ashley J.; Ruiz, Chris; Savin, Daniel Wolf; Schatz, Hendrik; Schneider, Dieter; Schwab, Josiah; Seitenzahl, Ivo; Shen, Ken; Siegert, Thomas; Sim, Stuart; Smith, David; Smith, Karl; Smith, Michael; Sollerman, Jesper; Sprouse, Trevor; Spyrou, Artemis; Starrfield, Sumner; Steiner, Andrew; Strong, Andrew W.; Sukhbold, Tuguldur; Suntzeff, Nick; Surman, Rebecca; Tanimori, Toru; The, Lih-Sin; Thielemann, Friedrich-Karl; Tolstov, Alexey; Tominaga, Nozomu; Tomsick, John; Townsley, Dean; Tsintari, Pelagia; Tsygankov, Sergey; Vartanyan, David; Venters, Tonia; Vestrand, Tom; Vink, Jacco; Waldman, Roni; Wang, Lifang; Wang, Xilu; Warren, MacKenzie; West, Christopher; Wheeler, J. Craig; Wiescher, Michael; Winkler, Christoph; Winter, Lisa; Wolf, Bill; Woolf, Richard; Woosley, Stan; Wu, Jin; Wrede, Chris; Yamada, Shoichi; Young, Patrick; Zegers, Remco; Zingale, Michael; Zwart, Simon Portegies
Comments: 14 pages including 3 figures
Submitted: 2019-02-07
Gamma-ray astronomy explores the most energetic photons in nature to address some of the most pressing puzzles in contemporary astrophysics. It encompasses a wide range of objects and phenomena: stars, supernovae, novae, neutron stars, stellar-mass black holes, nucleosynthesis, the interstellar medium, cosmic rays and relativistic-particle acceleration, and the evolution of galaxies. MeV gamma-rays provide a unique probe of nuclear processes in astronomy, directly measuring radioactive decay, nuclear de-excitation, and positron annihilation. The substantial information carried by gamma-ray photons allows us to see deeper into these objects, the bulk of the power is often emitted at gamma-ray energies, and radioactivity provides a natural physical clock that adds unique information. New science will be driven by time-domain population studies at gamma-ray energies. This science is enabled by next-generation gamma-ray instruments with one to two orders of magnitude better sensitivity, larger sky coverage, and faster cadence than all previous gamma-ray instruments. This transformative capability permits: (a) the accurate identification of the gamma-ray emitting objects and correlations with observations taken at other wavelengths and with other messengers; (b) construction of new gamma-ray maps of the Milky Way and other nearby galaxies where extended regions are distinguished from point sources; and (c) considerable serendipitous science of scarce events -- nearby neutron star mergers, for example. Advances in technology push the performance of new gamma-ray instruments to address a wide set of astrophysical questions.
[12]  oai:arXiv.org:1805.12562  [pdf] - 1749718
Dark Matter Search Results from a One Tonne$\times$Year Exposure of XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Elykov, A.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Grandi, L.; Greene, Z.; Qiu, H.; Hasterok, C.; Hogenbirk, E.; Howlett, J.; Itay, R.; Joerg, F.; Kaminsky, B.; Kazama, S.; Kish, A.; Koltman, G.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Mahlstedt, J.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Masson, D.; Messina, M.; Micheneau, K.; Miller, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pelssers, B.; Piastra, F.; Pienaar, J.; Pizzella, V.; Plante, G.; Podviianiuk, R.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Riedel, B.; Rizzo, A.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.
Comments: 8 pages, 5 figures, v2 limit points as csv
Submitted: 2018-05-31, last modified: 2018-09-13
We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra-low electron recoil background rate of $(82\substack{+5 \\ -3}\textrm{ (sys)}\pm3\textrm{ (stat)})$ events/$(\mathrm{t}\times\mathrm{yr}\times\mathrm{keV_{ee}})$. No significant excess over background is found and a profile likelihood analysis parameterized in spatial and energy dimensions excludes new parameter space for the WIMP-nucleon spin-independent elastic scatter cross-section for WIMP masses above 6 GeV/c${}^2$, with a minimum of $4.1\times10^{-47}$ cm$^2$ at 30 GeV/c${}^2$ and 90% confidence level.
[13]  oai:arXiv.org:1711.01265  [pdf] - 1774557
Science with e-ASTROGAM (A space mission for MeV-GeV gamma-ray astrophysics)
De Angelis, A.; Tatischeff, V.; Grenier, I. A.; McEnery, J.; Mallamaci, M.; Tavani, M.; Oberlack, U.; Hanlon, L.; Walter, R.; Argan, A.; Von Ballmoos, P.; Bulgarelli, A.; Bykov, A.; Hernanz, M.; Kanbach, G.; Kuvvetli, I.; Pearce, M.; Zdziarski, A.; Conrad, J.; Ghisellini, G.; Harding, A.; Isern, J.; Leising, M.; Longo, F.; Madejski, G.; Martinez, M.; Mazziotta, M. N.; Paredes, J. M.; Pohl, M.; Rando, R.; Razzano, M.; Aboudan, A.; Ackermann, M.; Addazi, A.; Ajello, M.; Albertus, C.; Alvarez, J. M.; Ambrosi, G.; Anton, S.; Antonelli, L. A.; Babic, A.; Baibussinov, B.; Balbo, M.; Baldini, L.; Balman, S.; Bambi, C.; de Almeida, U. Barres; Barrio, J. A.; Bartels, R.; Bastieri, D.; Bednarek, W.; Bernard, D.; Bernardini, E.; Bernasconi, T.; Bertucci, B.; Biland, A.; Bissaldi, E.; Boettcher, M.; Bonvicini, V.; Ramon, V. Bosch; Bottacini, E.; Bozhilov, V.; Bretz, T.; Branchesi, M.; Brdar, V.; Bringmann, T.; Brogna, A.; Jorgensen, C. Budtz; Busetto, G.; Buson, S.; Busso, M.; Caccianiga, A.; Camera, S.; Campana, R.; Caraveo, P.; Cardillo, M.; Carlson, P.; Celestin, S.; Cermeno, M.; Chen, A.; Cheung, C. C; Churazov, E.; Ciprini, S.; Coc, A.; Colafrancesco, S.; Coleiro, A.; Collmar, W.; Coppi, P.; da Silva, R. Curado; Cutini, S.; DAmmando, F.; De Lotto, B.; de Martino, D.; De Rosa, A.; Del Santo, M.; Delgado, L.; Diehl, R.; Dietrich, S.; Dolgov, A. D.; Dominguez, A.; Prester, D. Dominis; Donnarumma, I.; Dorner, D.; Doro, M.; Dutra, M.; Elsaesser, D.; Fabrizio, M.; FernandezBarral, A.; Fioretti, V.; Foffano, L.; Formato, V.; Fornengo, N.; Foschini, L.; Franceschini, A.; Franckowiak, A.; Funk, S.; Fuschino, F.; Gaggero, D.; Galanti, G.; Gargano, F.; Gasparrini, D.; Gehrz, R.; Giammaria, P.; Giglietto, N.; Giommi, P.; Giordano, F.; Giroletti, M.; Ghirlanda, G.; Godinovic, N.; Gouiffes, C.; Grove, J. E.; Hamadache, C.; Hartmann, D. H.; Hayashida, M.; Hryczuk, A.; Jean, P.; Johnson, T.; Jose, J.; Kaufmann, S.; Khelifi, B.; Kiener, J.; Knodlseder, J.; Kole, M.; Kopp, J.; Kozhuharov, V.; Labanti, C.; Lalkovski, S.; Laurent, P.; Limousin, O.; Linares, M.; Lindfors, E.; Lindner, M.; Liu, J.; Lombardi, S.; Loparco, F.; LopezCoto, R.; Moya, M. Lopez; Lott, B.; Lubrano, P.; Malyshev, D.; Mankuzhiyil, N.; Mannheim, K.; Marcha, M. J.; Marciano, A.; Marcote, B.; Mariotti, M.; Marisaldi, M.; McBreen, S.; Mereghetti, S.; Merle, A.; Mignani, R.; Minervini, G.; Moiseev, A.; Morselli, A.; Moura, F.; Nakazawa, K.; Nava, L.; Nieto, D.; Orienti, M.; Orio, M.; Orlando, E.; Orleanski, P.; Paiano, S.; Paoletti, R.; Papitto, A.; Pasquato, M.; Patricelli, B.; PerezGarcia, M. A.; Persic, M.; Piano, G.; Pichel, A.; Pimenta, M.; Pittori, C.; Porter, T.; Poutanen, J.; Prandini, E.; Prantzos, N.; Produit, N.; Profumo, S.; Queiroz, F. S.; Raino, S.; Raklev, A.; Regis, M.; Reichardt, I.; Rephaeli, Y.; Rico, J.; Rodejohann, W.; Fernandez, G. Rodriguez; Roncadelli, M.; Roso, L.; Rovero, A.; Ruffini, R.; Sala, G.; SanchezConde, M. A.; Santangelo, A.; Parkinson, P. Saz; Sbarrato, T.; Shearer, A.; Shellard, R.; Short, K.; Siegert, T.; Siqueira, C.; Spinelli, P.; Stamerra, A.; Starrfield, S.; Strong, A.; Strumke, I.; Tavecchio, F.; Taverna, R.; Terzic, T.; Thompson, D. J.; Tibolla, O.; Torres, D. F.; Turolla, R.; Ulyanov, A.; Ursi, A.; Vacchi, A.; Abeele, J. Van den; Kirilovai, G. Vankova; Venter, C.; Verrecchia, F.; Vincent, P.; Wang, X.; Weniger, C.; Wu, X.; Zaharijas, G.; Zampieri, L.; Zane, S.; Zimmer, S.; Zoglauer, A.; collaboration, the eASTROGAM
Comments: Published on Journal of High Energy Astrophysics (Elsevier)
Submitted: 2017-11-03, last modified: 2018-08-08
e-ASTROGAM (enhanced ASTROGAM) is a breakthrough Observatory space mission, with a detector composed by a Silicon tracker, a calorimeter, and an anticoincidence system, dedicated to the study of the non-thermal Universe in the photon energy range from 0.3 MeV to 3 GeV - the lower energy limit can be pushed to energies as low as 150 keV for the tracker, and to 30 keV for calorimetric detection. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with polarimetric capability. Thanks to its performance in the MeV-GeV domain, substantially improving its predecessors, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the most powerful Galactic and extragalactic sources, elucidating the nature of their relativistic outflows and their effects on the surroundings. With a line sensitivity in the MeV energy range one to two orders of magnitude better than previous generation instruments, e-ASTROGAM will determine the origin of key isotopes fundamental for the understanding of supernova explosion and the chemical evolution of our Galaxy. The mission will provide unique data of significant interest to a broad astronomical community, complementary to powerful observatories such as LIGO-Virgo-GEO600-KAGRA, SKA, ALMA, E-ELT, TMT, LSST, JWST, Athena, CTA, IceCube, KM3NeT, and LISA.
[14]  oai:arXiv.org:1805.06435  [pdf] - 1715331
The e-ASTROGAM gamma-ray space observatory for the multimessenger astronomy of the 2030s
Comments: 15 pages, 7 figures. Submitted to the proceedings of the conference SPIE Astronomical Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray. v2: corrections of authors' affiliations
Submitted: 2018-05-16, last modified: 2018-07-13
e-ASTROGAM is a concept for a breakthrough observatory space mission carrying a gamma-ray telescope dedicated to the study of the non-thermal Universe in the photon energy range from 0.15 MeV to 3 GeV. The lower energy limit can be pushed down to energies as low as 30 keV for gamma-ray burst detection with the calorimeter. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with remarkable polarimetric capability. Thanks to its performance in the MeV-GeV domain, substantially improving its predecessors, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the most powerful Galactic and extragalactic sources, elucidating the nature of their relativistic outflows and their effects on the surroundings. With a line sensitivity in the MeV energy range one to two orders of magnitude better than previous and current generation instruments, e-ASTROGAM will determine the origin of key isotopes fundamental for the understanding of supernova explosion and the chemical evolution of our Galaxy. The mission will be a major player of the multiwavelength, multimessenger time-domain astronomy of the 2030s, and provide unique data of significant interest to a broad astronomical community, complementary to powerful observatories such as LISA, LIGO, Virgo, KAGRA, the Einstein Telescope and the Cosmic Explorer, IceCube-Gen2 and KM3NeT, SKA, ALMA, JWST, E-ELT, LSST, Athena, and the Cherenkov Telescope Array.
[15]  oai:arXiv.org:1708.03617  [pdf] - 1644121
Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
XENON Collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Piro, M. -C.; Pizzella, V.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wang, Z.; Weber, M.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments: v1: 11 pages, 5 figures, 4 tables; v2: 12 pages, 5 figures, 4 tables, article updated after referee process
Submitted: 2017-08-11, last modified: 2018-03-03
In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main three science runs of the experiment over a period of $\sim$ 4 years, from January 2010 to January 2014. We compare our results to external measurements of radon emanation and krypton concentrations where we find good agreement. We report an observed reduction in concentrations of radon daughters that we attribute to the plating-out of charged ions on the negatively biased cathode.
[16]  oai:arXiv.org:1709.10149  [pdf] - 1690301
Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rupp, N.; Saldanha, R.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments:
Submitted: 2017-09-28, last modified: 2018-02-01
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two lower fields are in agreement with those from literature; additional measurements at a higher field of 366 V/cm are presented. The electronic and nuclear recoil discrimination as well as its dependence on the drift field and photon detection efficiency are investigated at these low energies. The results provide new measurements in the energy region of interest for dark matter searches using liquid xenon.
[17]  oai:arXiv.org:1705.06655  [pdf] - 1583594
First Dark Matter Search Results from the XENON1T Experiment
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Gardner, R.; Geis, C.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Howlett, J.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Mariş, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Riedel, B.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Saldanha, R.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thapa, S.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Upole, N.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.
Comments: 6 pages, 4 figures, v2 data upload Fig 2/4, v3 as accepted by PRL with textual clarifications, v4 data upload Fig 1
Submitted: 2017-05-18, last modified: 2017-11-23
We report the first dark matter search results from XENON1T, a $\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first ton-scale detector of this kind. The blinded search used 34.2 live days of data acquired between November 2016 and January 2017. Inside the (1042$\pm$12) kg fiducial mass and in the [5, 40] $\mathrm{keV}_{\mathrm{nr}}$ energy range of interest for WIMP dark matter searches, the electronic recoil background was $(1.93 \pm 0.25) \times 10^{-4}$ events/(kg $\times$ day $\times \mathrm{keV}_{\mathrm{ee}}$), the lowest ever achieved in a dark matter detector. A profile likelihood analysis shows that the data is consistent with the background-only hypothesis. We derive the most stringent exclusion limits on the spin-independent WIMP-nucleon interaction cross section for WIMP masses above 10 GeV/c${}^2$, with a minimum of 7.7 $\times 10^{-47}$ cm${}^2$ for 35-GeV/c${}^2$ WIMPs at 90% confidence level.
[18]  oai:arXiv.org:1704.05804  [pdf] - 1582670
Search for magnetic inelastic dark matter with XENON100
XENON collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhanga, Y.
Comments: 10 pages, 6 figures
Submitted: 2017-04-19, last modified: 2017-10-31
We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark matter which has been proposed to reconcile the modulation signal reported by the DAMA/LIBRA collaboration with the null results from other direct detection experiments. No candidate event has been found in the region of interest and upper limits on the WIMP's magnetic dipole moment are derived. The scenarios proposed to explain the DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of WIMPs with masses of 58.0 GeV/c$^2$ and 122.7 GeV/c$^2$ are excluded at 3.3 $\sigma$ and 9.3 $\sigma$, respectively.
[19]  oai:arXiv.org:1709.02222  [pdf] - 1602622
Search for Bosonic Super-WIMP Interactions with the XENON100 Experiment
XENON collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer; Calven, J.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Howlett, J.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.; Zhu, T.
Comments: 6 pages, 6 figures
Submitted: 2017-09-07
We present results of searches for vector and pseudo-scalar bosonic super-WIMPs, which are dark matter candidates with masses at the keV-scale, with the XENON100 experiment. XENON100 is a dual-phase xenon time projection chamber operated at the Laboratori Nazionali del Gran Sasso. A profile likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg showed no evidence for a signal above the expected background. We thus obtain new and stringent upper limits in the $(8-125)$\,keV/c$^2$ mass range, excluding couplings to electrons with coupling constants of $g_{ae} > 3\times10^{-13}$ for pseudo-scalar and $\alpha'/\alpha > 2\times10^{-28}$ for vector super-WIMPs, respectively. These limits are derived under the assumption that super-WIMPs constitute all of the dark matter in our galaxy.
[20]  oai:arXiv.org:1708.07051  [pdf] - 1697916
The XENON1T Dark Matter Experiment
XENON Collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Antunes, B.; Arneodo, F.; Balata, M.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Chiarini, A.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Corrieri, R.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Disdier, J. -M.; Doets, M.; Duchovni, E.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Florin, D.; Front, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Giboni, K. -L.; Goetzke, L. W.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Huhmann, C.; Itay, R.; James, A.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Maier, R.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Morå, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orlandi, D.; Othegraven, R.; Pakarha, P.; Parlati, S.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; García, D. Ramírez; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Saldahna, R.; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Sivers, M. v.; Stern, M.; Stein, A.; Tatananni, D.; Tatananni, L.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Upole, N.; Vargas, M.; Wack, O.; Walet, R.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wittweg, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments: 22 pages, 25 figures
Submitted: 2017-08-23
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomultipliers. This article describes the XENON1T instrument and its subsystems as well as strategies to achieve an unprecedented low background level. First results on the detector response and the performance of the subsystems are also presented.
[21]  oai:arXiv.org:1706.03687  [pdf] - 1584552
Optical response of highly reflective film used in the water Cherenkov muon veto of the XENON1T dark matter experiment
Comments: 25 pages, 27 figures. LaTeX math font styling changed for compatibility with arXiv
Submitted: 2017-06-12, last modified: 2017-06-13
The XENON1T experiment is the most recent stage of the XENON Dark Matter Search, aiming for the direct detection of Weakly Interacting Massive Particles (WIMPs). To reach its projected sensitivity, the background has to be reduced by two orders of magnitude compared to its predecessor XENON100. This requires a water Cherenkov muon veto surrounding the XENON1T TPC, both to shield external backgrounds and to tag muon-induced energetic neutrons through detection of a passing muon or the secondary shower induced by a muon interacting in the surrounding rock. The muon veto is instrumented with $84$ $8"$ PMTs with high quantum efficiency (QE) in the Cherenkov regime and the walls of the watertank are clad with the highly reflective DF2000MA foil by 3M. Here, we present a study of the reflective properties of this foil, as well as the measurement of its wavelength shifting (WLS) properties. Further, we present the impact of reflectance and WLS on the detection efficiency of the muon veto, using a Monte Carlo simulation carried out with Geant4. The measurements yield a specular reflectance of $\approx100\%$ for wavelengths larger than $400\,$nm, while $\approx90\%$ of the incoming light below $370\,$nm is absorbed by the foil. Approximately $3-7.5\%$ of the light hitting the foil within the wavelength range $250\,$nm $\leq \lambda \leq 390\,$nm is used for the WLS process. The intensity of the emission spectrum of the WLS light is slightly dependent on the absorbed wavelength and shows the shape of a rotational-vibrational fluorescence spectrum, peaking at around $\lambda \approx 420\,$nm. Adjusting the reflectance values to the measured ones in the Monte Carlo simulation originally used for the muon veto design, the veto detection efficiency remains unchanged. Including the wavelength shifting in the Monte Carlo simulation leads to an increase of the efficiency of approximately $0.5\%$.
[22]  oai:arXiv.org:1611.02232  [pdf] - 1580550
The e-ASTROGAM mission (exploring the extreme Universe with gamma rays in the MeV-GeV range)
Comments: Exp Astron (2017)
Submitted: 2016-11-07, last modified: 2017-06-04
e-ASTROGAM (`enhanced ASTROGAM') is a breakthrough Observatory mission dedicated to the study of the non-thermal Universe in the photon energy range from 0.3 MeV to 3 GeV. The mission is based on an advanced space-proven detector technology, with unprecedented sensitivity, angular and energy resolution, combined with polarimetric capability. In the largely unexplored MeV-GeV domain, e-ASTROGAM will open a new window on the non-thermal Universe, making pioneering observations of the most powerful Galactic and extragalactic sources, elucidating the nature of their relativistic outflows and their effects on Galactic ecosystems. With a line sensitivity in the MeV energy range one to two orders of magnitude better than previous generation instruments, will determine the origin of key isotopes fundamental for the understanding of supernova explosion and the chemical evolution of our Galaxy. The mission will provide unique data of significant interest to a broad astronomical community, complementary to powerful observatories such as LIGO-Virgo-GEO600-KAGRA, SKA, ALMA, E-ELT, TMT, LSST, JWST, Athena, CTA, IceCube, KM3NeT, and the promise of eLISA. Keywords: High-energy gamma-ray astronomy, High-energy astrophysics, Nuclear Astrophysics, Compton and Pair creation telescope, Gamma-ray bursts, Active Galactic Nuclei, Jets, Outflows, Multiwavelength observations of the Universe, Counterparts of gravitational waves, Fermi, Dark Matter, Nucleosynthesis, Early Universe, Supernovae, Cosmic Rays, Cosmic antimatter.
[23]  oai:arXiv.org:1705.02614  [pdf] - 1583194
Effective field theory search for high-energy nuclear recoils using the XENON100 dark matter detector
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Mora, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.; Farmer, B.
Comments:
Submitted: 2017-05-07
We report on WIMP search results in the XENON100 detector using a non-relativistic effective field theory approach. The data from science run II (34 kg $\times$ 224.6 live days) was re-analyzed, with an increased recoil energy interval compared to previous analyses, ranging from $(6.6 - 240)~\mathrm{keV_\mathrm{nr}}$. The data is found to be compatible with the background-only hypothesis. We present 90% confidence level exclusion limits on the coupling constants of WIMP-nucleon effective operators using a binned profile likelihood method. We also consider the case of inelastic WIMP scattering, where incident WIMPs may up-scatter to a higher mass state, and set exclusion limits on this model as well.
[24]  oai:arXiv.org:1705.05830  [pdf] - 1943215
Search for WIMP Inelastic Scattering off Xenon Nuclei with XENON100
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kazama, S.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Mora, K.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Vargas, M.; Wang, H.; Wang, Z.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments:
Submitted: 2017-05-01
We present the first constraints on the spin-dependent, inelastic scattering cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a dual-phase xenon time projection chamber with 62\,kg of active mass, operated at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to search for nuclear recoils from WIMP-nucleus interactions. Here we explore inelastic scattering, where a transition to a low-lying excited nuclear state of $^{129}$Xe is induced. The experimental signature is a nuclear recoil observed together with the prompt de-excitation photon. We see no evidence for such inelastic WIMP-$^{129}$Xe interactions. A profile likelihood analysis allows us to set a 90\% C.L. upper limit on the inelastic, spin-dependent WIMP-nucleon cross section of $3.3 \times 10^{-38}$\,cm$^{2}$ at 100\,GeV/c$^2$. This is the most constraining result to date, and sets the pathway for an analysis of this interaction channel in upcoming, larger dual-phase xenon detectors.
[25]  oai:arXiv.org:1608.03739  [pdf] - 1531251
The e-ASTROGAM gamma-ray space mission
Comments: 11 pages, 5 figures, published in the proceedings of SPIE Astronomical Telescopes and Instrumentation: Ultraviolet to Gamma Ray conference, Edinburgh 2016. Addition of an acknowledgment statement in version 2
Submitted: 2016-08-12, last modified: 2017-01-31
The e-ASTROGAM is a gamma-ray space mission to be proposed as the M5 Medium-size mission of the European Space Agency. It is dedicated to the observation of the Universe with unprecedented sensitivity in the energy range 0.2 - 100 MeV, extending up to GeV energies, together with a groundbreaking polarization capability. It is designed to substantially improve the COMPTEL and Fermi sensitivities in the MeV-GeV energy range and to open new windows of opportunity for astrophysical and fundamental physics space research. e-ASTROGAM will operate as an open astronomical observatory, with a core science focused on (1) the activity from extreme particle accelerators, including gamma-ray bursts and active galactic nuclei and the link of jet astrophysics to the new astronomy of gravitational waves, neutrinos, ultra-high energy cosmic rays, (2) the high-energy mysteries of the Galactic center and inner Galaxy, including the activity of the supermassive black hole, the Fermi Bubbles, the origin of the Galactic positrons, and the search for dark matter signatures in a new energy window; (3) nucleosynthesis and chemical evolution, including the life cycle of elements produced by supernovae in the Milky Way and the Local Group of galaxies. e-ASTROGAM will be ideal for the study of high-energy sources in general, including pulsars and pulsar wind nebulae, accreting neutron stars and black holes, novae, supernova remnants, and magnetars. And it will also provide important contributions to solar and terrestrial physics. The e-ASTROGAM telescope is optimized for the simultaneous detection of Compton and pair-producing gamma-ray events over a large spectral band. It is based on a very high technology readiness level for all subsystems and includes many innovative features for the detectors and associated electronics.
[26]  oai:arXiv.org:1609.06154  [pdf] - 1531664
XENON100 Dark Matter Results from a Combination of 477 Live Days
XENON100 Collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Calvén, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Duchovni, E.; Fei, J.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Calloch, M. Le; Levy, C.; Lin, Q.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Piro, M. -C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C. D.; Wall, R.; Wang, H.; Weber, M.; Wei, Y.; Weinheimer, C.; Wulf, J.; Zhang, Y.
Comments: 12 pages, 13 figures, 2 tables, Limit data points in TeX
Submitted: 2016-09-20, last modified: 2017-01-12
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic recoil rejection, together with the increased exposure of 48 kg $\times$ yr improves the sensitivity. A profile likelihood analysis using an energy range of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic, spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and 90% confidence level. We also report updated constraints on the elastic, spin-dependent WIMP-nucleon cross sections obtained with the same data. We set upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0 $\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50 GeV/$c^2$, at 90% confidence level.
[27]  oai:arXiv.org:1701.00769  [pdf] - 1542876
Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data
The XENON collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Butikofer, L.; Calven, J.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Diglio, S.; Eurin, G.; Fei, J.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Manfredini, A.; Maris, I.; Undagoitia, T. Marrodan; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Pizzella, V.; Piro, M. -C.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M.; Simgen, H.; Sivers, M. v.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; Wang, H.; Wei, Y.; Weinheimer, C.; Wulf, J.; Ye, J.; Zhang, Y.
Comments: 6 pages, 5 figures
Submitted: 2017-01-03
We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in the low energy region of $(2.0-5.8)$ keV in the single scatter event sample, with a global significance of $1.9\,\sigma$, however no other more significant modulation is observed. The expected annual modulation of a dark matter signal is not compatible with this result. Single scatter events in the low energy region are thus used to exclude the DAMA/LIBRA annual modulation as being due to dark matter electron interactions via axial vector coupling at $5.7\,\sigma$.
[28]  oai:arXiv.org:1404.1455  [pdf] - 1693885
First Axion Results from the XENON100 Experiment
Comments:
Submitted: 2014-04-05, last modified: 2016-12-22
We present the first results of searches for axions and axion-like-particles with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$, has been probed by exploiting the axio-electric effect in liquid xenon. A profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times 10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For axion-like-particles, under the assumption that they constitute the whole abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than $1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set the best limit to date as well.
[29]  oai:arXiv.org:1605.06262  [pdf] - 1530726
A low-mass dark matter search using ionization signals in XENON100
XENON100 Collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arneodo, F.; Barrow, P.; Baudis, L.; Bauermeister, B.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Bruenner, E. Brown S.; Bruno, G.; Budnik, R.; Buss, A.; Bütikofer, L.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Duchovni, E.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Galloway, M.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Gross, E.; Hasterok, C.; Hogenbirk, E.; Itay, R.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Calloch, M. Le; Levy, C.; Linde, F.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Lyashenko, A.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Masson, D.; Mayani, D.; Fernandez, A. J. Melgarejo; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Simgen, H.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C. D.; von Sivers, M.; Wall, R.; Wang, H.; Weber, M.; Wei, Y.; Weinheimer, C.; Wulf, J.; Zhang, Y.
Comments: 6 pages; 7 figures; PRD. Additional file in source material, s2stot, contains the full list of events passing all selection cuts. Limit data points in TeX; Corrected LUX points used for comparison and respective reference in figure 5
Submitted: 2016-05-20, last modified: 2016-12-19
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be constructed without a primary scintillation signal. Instead, we compute an upper limit on the WIMP-nucleon scattering cross section under the assumption that every event passing our selection criteria could be a signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\% confidence level.
[30]  oai:arXiv.org:1606.07001  [pdf] - 1525702
DARWIN: towards the ultimate dark matter detector
Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Amsler, C.; Aprile, E.; Arazi, L.; Arneodo, F.; Barrow, P.; Baudis, L.; Benabderrahmane, M. L.; Berger, T.; Beskers, B.; Breskin, A.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Buetikofer, L.; Calven, J.; Cardoso, J. M. R.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; Diglio, S.; Drexlin, G.; Duchovni, E.; Erdal, E.; Eurin, G.; Ferella, A.; Fieguth, A.; Fulgione, W.; Rosso, A. Gallo; Di Gangi, P.; Di Giovanni, A.; Galloway, M.; Garbini, M.; Geis, C.; Glueck, F.; Grandi, L.; Greene, Z.; Grignon, C.; Hasterok, C.; Hannen, V.; Hogenbirk, E.; Howlett, J.; Hilk, D.; Hils, C.; James, A.; Kaminsky, B.; Kazama, S.; Kilminster, B.; Kish, A.; Krauss, L. M.; Landsman, H.; Lang, R. F.; Lin, Q.; Linde, F. L.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Undagoitia, T. Marrodan; Masbou, J.; Massoli, F. V.; Mayani, D.; Messina, M.; Micheneau, K.; Molinario, A.; Mora, K. D.; Morteau, E.; Murra, M.; Naganoma, J.; Newstead, J. L.; Ni, K.; Oberlack, U.; Pakarha, P.; Pelssers, B.; de Perio, P.; Persiani, R.; Piastra, F.; Piro, M. C.; Plante, G.; Rauch, L.; Reichard, S.; Rizzo, A.; Rupp, N.; Santos, J. M. F. Dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schumann, M.; Schreiner, J.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Silva, M. C.; Simgen, H.; Sissol, P.; von Sivers, M.; Thers, D.; Thurn, J.; Tiseni, A.; Trotta, R.; Tunnell, C. D.; Valerius, K.; Vargas, M. A.; Wang, H.; Wei, Y.; Weinheimer, C.; Wester, T.; Wulf, J.; Zhang, Y.; Zhu, T.; Zuber, K.
Comments: 36 pages, 11 figures
Submitted: 2016-06-22
DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/c2, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of 136-Xe, as well as measure the low-energy solar neutrino flux with <1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R&D efforts.
[31]  oai:arXiv.org:1512.07501  [pdf] - 1395004
Physics reach of the XENON1T dark matter experiment
The XENON collaboration; Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Amaro, F. D.; Anthony, M.; Arazi, L.; Arneodo, F.; Balan, C.; Barrow, P.; Baudis, L.; Bauermeister, B.; Berger, T.; Breur, P.; Breskin, A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Bütikofer, L.; Cardoso, J. M. R.; Cervantes, M.; Cichon, D.; Coderre, D.; Colijn, A. P.; Conrad, J.; Contreras, H.; Cussonneau, J. P.; Decowski, M. P.; de Perio, P.; Di Gangi, P.; Di Giovanni, A.; Duchovni, E.; Fattori, S.; Ferella, A. D.; Fieguth, A.; Franco, D.; Fulgione, W.; Galloway, M.; Garbini, M.; Geis, C.; Goetzke, L. W.; Greene, Z.; Grignon, C.; Gross, E.; Hampel, W.; Hasterok, C.; Itay, R.; Kaether, F.; Kaminsky, B.; Kessler, G.; Kish, A.; Landsman, H.; Lang, R. F.; Lellouch, D.; Levinson, L.; Calloch, M. Le; Levy, C.; Lindemann, S.; Lindner, M.; Lopes, J. A. M.; Lyashenko, A.; Macmullin, S.; Manfredini, A.; Undagoitia, T. Marrodán; Masbou, J.; Massoli, F. V.; Mayani, D.; Fernandez, A. J. Melgarejo; Meng, Y.; Messina, M.; Micheneau, K.; Miguez, B.; Molinario, A.; Murra, M.; Naganoma, J.; Oberlack, U.; Orrigo, S. E. A.; Pakarha, P.; Pelssers, B.; Persiani, R.; Piastra, F.; Pienaar, J.; Plante, G.; Priel, N.; Rauch, L.; Reichard, S.; Reuter, C.; Rizzo, A.; Rosendahl, S.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Shagin, P.; Simgen, H.; Stein, A.; Thers, D.; Tiseni, A.; Trinchero, G.; Tunnell, C.; von Sivers, M.; Wall, R.; Wang, H.; Weber, M.; Wei, Y.; Weinheimer, C.; Wulf, J.; Zhang, Y.
Comments: 36 pages, 18 figures, published by JCAP
Submitted: 2015-12-23, last modified: 2016-04-15
The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in $1$ tonne fiducial volume and ($1$, $12$) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm 0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region ($4$, $50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$ from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$ cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
[32]  oai:arXiv.org:1507.07748  [pdf] - 1268647
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
Comments: 6 pages, 4 figures
Submitted: 2015-07-28
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
[33]  oai:arXiv.org:1507.07747  [pdf] - 1264865
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic Recoil Data
Comments: 4 pages, 4 figures, with supporting online material
Submitted: 2015-07-28
Laboratory experiments searching for galactic dark matter particles scattering off nuclei have so far not been able to establish a discovery. We use data from the XENON100 experiment to search for dark matter interacting with electrons. With no evidence for a signal above the low background of our experiment, we exclude a variety of representative dark matter models that would induce electronic recoils. For axial-vector couplings to electrons, we exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2 GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as explanation for the long-standing DAMA/LIBRA signal, such as couplings to electrons through axial-vector interactions at a 4.4 sigma confidence level, mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
[34]  oai:arXiv.org:1503.07698  [pdf] - 1342737
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
Comments: 10 pages, 5 figures
Submitted: 2015-03-26
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
[35]  oai:arXiv.org:1406.2374  [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Comments:
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
[36]  oai:arXiv.org:1311.1088  [pdf] - 783783
Observation and applications of single-electron charge signals in the XENON100 experiment
Comments: 16 pages, 8 figures. Accepted for publication in Journal of Physics G: Nuclear and Particle Physics
Submitted: 2013-11-05, last modified: 2014-01-28
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
[37]  oai:arXiv.org:1207.3458  [pdf] - 1693882
Analysis of the XENON100 Dark Matter Search Data
Comments: 18 pages, 17 figures, information for the 224.6 live days run included
Submitted: 2012-07-14, last modified: 2013-10-14
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
[38]  oai:arXiv.org:1306.2303  [pdf] - 1171929
The neutron background of the XENON100 dark matter experiment
Comments:
Submitted: 2013-06-10, last modified: 2013-09-02
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($\alpha$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
[39]  oai:arXiv.org:1304.1427  [pdf] - 705114
Response of the XENON100 Dark Matter Detector to Nuclear Recoils
Comments: 10 pages, 10 figures. Matches version accepted by PRD. Contains revised representation of expected WIMP event signature. Conclusions remain unaffected
Submitted: 2013-04-04, last modified: 2013-07-18
Results from the nuclear recoil calibration of the XENON100 dark matter detector installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy are presented. Data from measurements with an external 241AmBe neutron source are compared with a detailed Monte Carlo simulation which is used to extract the energy dependent charge-yield Qy and relative scintillation efficiency Leff. A very good level of absolute spectral matching is achieved in both observable signal channels - scintillation S1 and ionization S2 - along with agreement in the 2-dimensional particle discrimination space. The results confirm the validity of the derived signal acceptance in earlier reported dark matter searches of the XENON100 experiment.
[40]  oai:arXiv.org:1104.3088  [pdf] - 661239
A search for light dark matter in XENON10 data
Comments: Manuscript identical to v2 (published version) but also contains erratum. Note v3==v2 but without \linenumbers
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
[41]  oai:arXiv.org:1207.5988  [pdf] - 642231
Dark Matter Results from 225 Live Days of XENON100 Data
Comments: 6 pages, 5 figures. Matches version accepted by PRL. Includes limits up to 10 TeV/c^2, published as supplementary material: http://prl.aps.org/supplemental/PRL/v109/i18/e181301 Please cite high mass limits as "Phys. Rev. Lett. 109, 181301 (2012), online supplementary material."
Submitted: 2012-07-25, last modified: 2013-03-20
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
[42]  oai:arXiv.org:1101.3866  [pdf] - 956174
Study of the electromagnetic background in the XENON100 experiment
Comments: 10 pages, 12 figures The updated version of the paper takes into account the new measurement of $^{136}$Xe 2$\nu$ $\beta\beta$ decay by EXO-200, with a half-life of (2.11$\pm0.04\pm$0.021)$\times10^{21}$ years
Submitted: 2011-01-20, last modified: 2013-02-21
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.
[43]  oai:arXiv.org:1301.6620  [pdf] - 704634
Limits on spin-dependent WIMP-nucleon cross sections from 225 live days of XENON100 data
Comments: 5 pages, 3 figures; corrected caption of figure 3
Submitted: 2013-01-28, last modified: 2013-01-29
We present new experimental constraints on the elastic, spin-dependent WIMP-nucleon cross section using recent data from the XENON100 experiment, operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of 224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe nuclei. This leads to the most stringent upper limits on WIMP-neutron cross sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x 10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
[44]  oai:arXiv.org:1211.0836  [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Comments: 12 pages, 4 figures
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
[45]  oai:arXiv.org:1208.5762  [pdf] - 555466
Comment on "On the subtleties of searching for dark matter with liquid xenon detectors"
Comments: 3 pages, no figures
Submitted: 2012-08-28
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that XENON100's upper limits on spin-independent WIMP-nucleon cross sections for WIMP masses below 10 GeV "may be understated by one order of magnitude or more". Having performed a similar, though more detailed analysis prior to the submission of our new result (arXiv:1207.5988), we do not confirm these findings. We point out the rationale for not considering the described effect in our final analysis and list several potential problems with his study.
[46]  oai:arXiv.org:1107.2155  [pdf] - 474250
The XENON100 Dark Matter Experiment
Comments: 23 pages, 27 figures; version accepted by journal
Submitted: 2011-07-11, last modified: 2012-02-08
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs. The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of \sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
[47]  oai:arXiv.org:1104.3121  [pdf] - 418418
Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data
Comments: 3 pages, 3 figures
Submitted: 2011-04-15, last modified: 2011-09-09
The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.
[48]  oai:arXiv.org:1104.2549  [pdf] - 966664
Dark Matter Results from 100 Live Days of XENON100 Data
Comments: 5 pages, 5 figures; matches accepted version
Submitted: 2011-04-13, last modified: 2011-09-07
We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.
[49]  oai:arXiv.org:1103.0303  [pdf] - 427646
Likelihood Approach to the First Dark Matter Results from XENON100
Comments: 8 pages, 6 figures, matches accepted version
Submitted: 2011-03-01, last modified: 2011-09-07
Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.
[50]  oai:arXiv.org:1005.0380  [pdf] - 325339
First Dark Matter Results from the XENON100 Experiment
Comments: 5 pages, 5 figures. Matches published version
Submitted: 2010-05-03, last modified: 2011-03-01
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.
[51]  oai:arXiv.org:0910.3698  [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Comments: 8 pages, 4 figures
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_{\chi}\gtrsim150$ GeV are disfavored.
[52]  oai:arXiv.org:1011.6439  [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Comments: Conference proceedings from the Identification of Dark Matter 2010, Montpellier, France. To be published by SISSA as PoS(IDM2010)017
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
[53]  oai:arXiv.org:1006.2102  [pdf] - 188133
DUAL Gamma-Ray Mission
Comments: White paper for US National Academy of Sciences Decadal Survey "Astro2010"
Submitted: 2010-06-10
Gamma-ray astronomy presents an extraordinary scientific potential for the study of the most powerful sources and the most violent events in the Universe. In order to take full advantage of this potential, the next generation of instrumentation for this domain will have to achieve an improvement in sensitivity over present technologies of at least an order of magnitude. The DUAL mission concept takes up this challenge in two complementary ways: a very long observation of the entire sky, combined with a large collection area for simultaneous observations of Type Ia SNe. While the Wide-Field Compton Telescope (WCT) accumulates data from the full gamma-ray sky (0.1-10 MeV) over the entire mission lifetime, the Laue-Lens Telescope (LLT) focuses on 56Co emission from SNe Ia (0.8-0.9 MeV), collecting gamma-rays from its large area crystal lens onto the WCT. Two separated spacecraft flying in formation will maintain the DUAL payloads at the lens' focal distance.
[54]  oai:arXiv.org:1001.2834  [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Comments:
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
[55]  oai:arXiv.org:0807.0459  [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear recoils
Comments: 8 pages, 9 figures. To be published in Nucl. Instrum. Methods A
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
[56]  oai:arXiv.org:0805.2939  [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Comments: 4 pages, 4 figures; final version published in PRL (added DAMA region to Figure 1)
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
[57]  oai:arXiv.org:0706.0039  [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Comments: accepted for publication in Phys. Rev. Lett
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
[58]  oai:arXiv.org:physics/0702078  [pdf] - 119207
A Study of the LXeGRIT Detection Efficiency for MeV Gamma-Rays during the 2000 Balloon Flight Campaign
Comments: 20 pages, 15 figures; submitted to NIMA
Submitted: 2007-02-09
LXeGRIT - Liquid Xenon Gamma-Ray Imaging Telescope - is the first prototype of a Compton telescope for \MeV \g-ray astrophysics based on a LXe time projection chamber. One of the most relevant figures of merit for a Compton telescope is the detection efficiency for \g-rays, which depends on diverse contributions such as detector geometry and passive materials, trigger efficiency, dead time, etc. A detailed study of the efficiency of the LXeGRIT instrument, based both on laboratory measurements and Monte Carlo simulations, is presented in this paper.
[59]  oai:arXiv.org:astro-ph/0609714  [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Comments: Presented at the 7th UCLA Symposium on "Sources and Detection of Dark Matter and Dark Energy in the Universe"
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
[60]  oai:arXiv.org:astro-ph/0608532  [pdf] - 1938972
The Advanced Compton Telescope Mission
Comments: NASA Vision Mission Concept Study Report, final version. (A condensed version of this report has been submitted to AIAA.)
Submitted: 2006-08-24
The Advanced Compton Telescope (ACT), the next major step in gamma-ray astronomy, will probe the fires where chemical elements are formed by enabling high-resolution spectroscopy of nuclear emission from supernova explosions. During the past two years, our collaboration has been undertaking a NASA mission concept study for ACT. This study was designed to (1) transform the key scientific objectives into specific instrument requirements, (2) to identify the most promising technologies to meet those requirements, and (3) to design a viable mission concept for this instrument. We present the results of this study, including scientific goals and expected performance, mission design, and technology recommendations.
[61]  oai:arXiv.org:astro-ph/0407575  [pdf] - 66417
The XENON Dark Matter Search Experiment
Comments: 9 pages, 8 figures, appear in the Proceeding of 6th UCLA Symposium on Sources and Detection of Dark Matter and Dark Energy in the Universe
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.
[62]  oai:arXiv.org:astro-ph/0211584  [pdf] - 53319
On the Background Rate in the LXeGRIT Instrument during the 2000 Balloon Flight
Comments: 13 pages, 12 figures, SPIE 2002 Proceedings, Conf. Vol. 4851 - 151; corrected references
Submitted: 2002-11-26, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel Compton telescope for MeV gamma-ray astrophysics based on a Liquid Xenon Time Projection Chamber (LXeTPC), sensitive in the energy band of 0.15-10 MeV. In this homogeneous, 3D position sensitive detector, gamma rays with at least two interactions in the sensitive volume of 2800 cm$^{3}$, are imaged as in a standard Compton telescope. Gamma-rays with a single interaction cannot be imaged and constitute a background which can be easily identified and rejected. Charged particles and localized beta-particles background is also easily suppressed based on the TPC localization capability with millimeter resolution. A measurement of the total gamma-ray background rate in near space conditions and the background rejection power of the LXeTPC was a primary goal of the LXeGRIT balloon flight program. We present here a preliminary analysis addressing this question, based on balloon flight data acquired during the Oct 4-5, 2000 LXeGRIT balloon flight from Ft. Sumner, NM. In this long duration (27 hr) balloon experiment, the LXeGRIT TPC was not surrounded by any gamma-ray or charged particle shield. Single site events and charged particles were mostly rejected on-line at the first and second trigger level. The remaining count rate of single-site \g-ray events, at an average atmospheric depth of 3.2 g cm$^{-2}$, is consistent with that expected from atmospheric and diffuse gamma-ray background, taking into account the instrument mass model and response.
[63]  oai:arXiv.org:astro-ph/0212005  [pdf] - 53395
The LXeGRIT Compton Telescope Prototype: Current Status and Future Prospects
Comments: 13 pages, 11 figures, SPIE 2002 Proceedings, Conf. Vol. 4851 - 140; corrected references
Submitted: 2002-11-30, last modified: 2002-12-04
LXeGRIT is the first prototype of a novel concept of Compton telescope, based on the complete 3-dimensional reconstruction of the sequence of interactions of individual gamma rays in one position sensitive detector. This balloon-borne telescope consists of an unshielded time projection chamber with an active volume of 400 cm$^2 \times 7$ cm filled with high purity liquid xenon. Four VUV PMTs detect the fast xenon scintillation light signal, providing the event trigger. 124 wires and 4 anodes detect the ionization signals, providing the event spatial coordinates and total energy. In the period 1999 -- 2001, LXeGRIT has been extensively tested both in the laboratory and at balloon altitude, and its response in the MeV region has been thoroughly characterized. Here we summarize some of the results on pre-flight calibration, event reconstruction techniques, and performance during a 27 hour balloon flight on October 4 -- 5. We further present briefly the on-going efforts directed to improve the performance of this prototype towards the requirements for a base module of a next-generation Compton telescope.
[64]  oai:arXiv.org:astro-ph/0207670  [pdf] - 1591929
XENON: a 1 tonne Liquid Xenon Experiment for a Sensitive Dark Matter Search
Comments: 14 pages, 6 figures, submitted to proceedings of the International Workshop on Techniques and Applications of Xenon Detectors (Xenon01), ICRR, Univ. of Tokyo, Kashiwa, Japan, held December 2001 (World Scientific)
Submitted: 2002-07-31
XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of ionization and scintillation signals in liquid xenon, with the goal of extracting as much information as possible on an event-by-event basis, while maintaining most of the target active. XENON is expected to have effective and redundant background identification and discrimination power, higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV visible recoil energy. Based on this expectation and the 1-tonne mass of active xenon, we project a sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate underground location. The XENON experiment has been recently proposed to the National Science Foundation (NSF) for an initial development phase leading to the development of the 100 kg unit module.
[65]  oai:arXiv.org:astro-ph/0107468  [pdf] - 43839
Detection of the 67.9 keV and 78.4 keV lines associated with the radioactive decay of Ti-44 in Cassiopeia A
Comments: 4 pages, 2 figures, accepted to appear in ApJ Letters v560 (small corrections, plus expanded "Observation and Data" section)
Submitted: 2001-07-24, last modified: 2001-09-18
We report the detection of the Sc-44 nuclear decay lines at 67.9 keV and 78.4 keV associated with the nuclear decay of Ti-44 in Cassiopeia A. The line emission was observed by the PDS instrument on board BeppoSAX, which recently observed the supernova remnant for over 500 ks. The detection of the line emission with a flux of (2.1 +/-0.7) 10^{-5} ph/cm^2/s in each line (90% confidence) is at the 5 sigma significance level, if we can assume that the 12-300 keV continuum is adequately represented by a single power law. However, as the nature of the continuum is not clear we investigate various other possibilities. A more conservative estimate of the line flux is made by assuming that a power law continuum is at least a good approximation to the continuum emission for a narrower 30-100 keV energy range. With this limitation the measured line flux is (1.9 +/- 0.9) 10^{-5} ph/cm^2/s, with the detection still at the 3.4 sigma significance level. We suggest that together with the CGRO-COMPTEL measurement of the Ca-44 line at 1157 keV of (3.5 +/- 0.9) 10^{-5} ph/cm^2/s a flux for all three lines of (2.5 +/- 1.0) 10^{-5} ph/cm^2/s for Cas A can be adopted. This implies an initial Ti-44 mass of (0.8 - 2.5) 10^{-4} Msun.
[66]  oai:arXiv.org:astro-ph/0106125  [pdf] - 42921
Gamma-Ray Line Emission from Superbubbles in the Interstellar Medium: The Cygnus Region
Comments: 5 pages, 3 figures, to appear in Proc. of Gamma-Ray Astrophysics 2001, to be published in AIP Conf. Proc. Series
Submitted: 2001-06-07
The star forming process in the Milky Way is non-uniform in time and space. The scale of star forming regions ranges from groups within a few pc to large segments of spiral arms with linear dimension of order kpc. When many stars form in a relatively small volume over a short duration, a localized starburst ensues. The energetic impact of such a burst of star formation can severely affect the dynamic structure of the gaseous disk. Stellar winds and supernova explosions drive an expanding superbubble, whose size eventually exceeds the scale height of the disk and thus drives a disk-wind blowing metal enriched gas into the halo. We discuss the basic scenario of superbubble evolution, emphasizing the associated gamma-ray line signatures. In particular, we discuss nuclear line emission from 26Al and 60Fe in the Cygnus region.
[67]  oai:arXiv.org:astro-ph/0104047  [pdf] - 41786
The Comptel 1.809 Mev Survey
Comments: 4 pages, 5 figures, accepted for publication in the proceedings of the 4th INTEGRAL workshop, to appear in ESA-SP series
Submitted: 2001-04-03
We present the latest update of the 1.809 MeV sky survey obtained with COMPTEL. Based on all observations taken since the launch of CGRO in spring 1991 to early summer this year we obtain 1.809 MeV all sky maps using different imaging methods. The background is modelled on the basis of an adjacent energy approach. We confirm the previously reported characteristics of the galactic 1.809 MeV emission, specifically excesses in regions away from the inner Galaxy. The observed 1.8 MeV gamma-ray line is ascribed to the radioactive decay of 26Al in the interstellar medium. 26Al has been found to be predominantly synthesised in massive stars and their subsequent core-collapse supernovae, which is confirmed in tracer comparisons. Due to this, one anticipates flux enhancements aligned with regions of recent star formation, such as apparently observed in the Cygnus and Vela regions.
[68]  oai:arXiv.org:astro-ph/0104052  [pdf] - 1043447
Radioactivities in Population Studies: 26Al and 60Fe from OB Associations
Comments: 10 pages, 7 figures, to appear in Proc. "Influence of Binaries on Stellar Population Studies", eds. Vanbeveren & Van Rensbergen, Brussels, Aug. 2000
Submitted: 2001-04-03
The observation of the interstellar 1.809 MeV decay-line of radioactive 26Al by the imaging gamma-ray telescope COMPTEL have let to the conclusion, that massive stars and their subsequent core-collapse supernovae are the dominant sources of the interstellar 26Al abundance. Massive stars are known to affect the surrounding interstellar medium by their energetic stellar winds and by the emission of ionising radiation. We present a population synthesis model allowing the correlated investigation of the gamma-ray emission characteristics with integrated matter, kinetic energy and extreme ultra-violet radiation emission of associations of massive stars. We study the time evolution of the various observables. In addition, we discuss systematic as well as statistical uncertainties affecting the model. Beside uncertainties in the input stellar physics such as stellar rotation, mass loss rates or internal mixing modifications due to a unknown binary component may lead to significant uncertainties.
[69]  oai:arXiv.org:astro-ph/0104050  [pdf] - 41789
The Cygnus Region: 26Al from OB Associations
Comments: 5 pages, 5 figures, accepted for publication in the proceedings of the 4th INTEGRAL workshop, to appear in ESA-SP series
Submitted: 2001-04-03
The COMPTEL map of the 1.809 MeV gamma-ray line, which is attributed to the radioactive decay of 26Al, shows significant excess emission in the Cygnus region. Cygnus is a region of recent star formation activity, which is rich in massive, early-type stars concentrated in OB associations. We perform population synthesis studies of this region to model the production and distribution of 26Al, which is predominantly synthesized in massive stars and distributed through stellar winds and core-collapse supernovae. Our simulations of the Cygnus OB associations determine the time-dependent production rate of 26Al. We also estimate the associated production of radioactive 60Fe, which is primarily synthesized in core-collapse supernovae. Gamma-ray line emission from this isotope has yet to be detected. We also track the temporal evolution of the mechanical "luminosity" due to the kinetic energy of stellar winds and supernova ejecta, and the ionizing EUV emission from early-type stars. Together with a simple one-dimensional model of the superbubble driven into the ISM by this energy flux one can constrain key parameters of the stellar associations in the Cygnus region.
[70]  oai:arXiv.org:astro-ph/0012398  [pdf] - 1232610
Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Comments: 16 pages, 15 figures; To appear in: X-Ray and Gamma-Ray Instrumentation for Astronomy XI, 2000; Proc. SPIE, vol. 4140; K.A. Flanagan & O.H. Siegmund, eds
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional spatial resolution as measured during pre-flight calibration experiments, are $\Delta E_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively. The detection efficiency for Compton events varies between 1.5% and 4% depending on energy and event selection. We describe the instrument as flown on May 7, 1999 and review its overall performance at balloon altitude. The launch occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was terminated about 9 hours later. The Crab was in the instrument FOV for a few hours. Analysis of these data is in progress.
[71]  oai:arXiv.org:astro-ph/0012395  [pdf] - 39984
Performance of the Light Trigger System in the Liquid Xenon Gamma-Ray Telescope LXeGRIT
Comments: Submitted to IEEE Trans. on Nuc. Sci., 7 pages, 11 figures
Submitted: 2000-12-18
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber with charge and light readout. The energy and direction of an incident gamma-ray is reconstructed from the three-dimensional locations and energy deposits of individual interactions taking place in the homogeneous detector volume. While the charge signals provide energy information and X-Y positions, the fast xenon scintillation light signal is used to trigger the detector. The drift time measurement, referred to the time of the trigger signal, gives the Z-position with the known drift velocity. The light is detected by four UV-sensitive photomultiplier tubes (PMTs). The logical OR of the PMT signals triggers the data acquisition system with an efficiency which depends on the event energy and location, as well as on the discriminator thresholds used on the individual PMTs. Results from experiments with a tagged 22Na source give the spatial distribution of the light trigger efficiency for 511 keV gamma-rays. When averaged over the whole sensitive volume amd all PMTs, the trigger efficiency is 47% or 40% for two discriminator windows used during the LXeGRIT balloon flight of 1999. These values are strongly affected by the different sensitivity of each PMT. The corresponding average efficiency at 511 keV for the best of the four PMTs is in fact 63%, and approaches 100% for interactions taking place in a small volume right above the PMT.
[72]  oai:arXiv.org:astro-ph/0012332  [pdf] - 39921
The COMPTEL instrumental line background
Comments: accepted for publication in A&A, 22 pages, 21 figures
Submitted: 2000-12-14
The instrumental line background of the Compton telescope COMPTEL onboard the Compton Gamma-Ray Observatory is due to the activation and/or decay of many isotopes. The major components of this background can be attributed to eight individual isotopes, namely 2D, 22Na, 24Na, 28Al, 40K, 52Mn, 57Ni, and 208Tl. The identification of instrumental lines with specific isotopes is based on the line energies as well as on the variation of the event rate with time, cosmic-ray intensity, and deposited radiation dose during passages through the South-Atlantic Anomaly. The characteristic variation of the event rate due to a specific isotope depends on its life-time, orbital parameters such as the altitude of the satellite above Earth, and the solar cycle. A detailed understanding of the background contributions from instrumental lines is crucial at MeV energies for measuring the cosmic diffuse gamma-ray background and for observing gamma-ray line emission in the interstellar medium or from supernovae and their remnants. Procedures to determine the event rate from each background isotope are described, and their average activity in spacecraft materials over the first seven years of the mission is estimated.
[73]  oai:arXiv.org:astro-ph/0012276  [pdf] - 39865
An Upgraded Data Acquisition System for the Balloon-Borne Liquid Xenon Gamma-Ray Telescope LXeGRIT
Comments: Submitted to IEEE Trans. on Nuc. Sci., 6 pages, 3 figures
Submitted: 2000-12-12, last modified: 2000-12-14
LXeGRIT is a balloon-borne Compton telescope for MeV gamma-ray astrophysics, based on a liquid xenon time projection chamber (LXe-TPC) with charge and light readout. The first balloon flights in 1997 revealed limitations of the trigger electronics and the data acquisition (DAQ) system, leading to their upgrade. New electronics was developed to handle the xenon scintillation light trigger. The original processor module was replaced by a commercial VME processor. The telemetry rate was doubled to 2 x 500 kbps and onboard data storage on hard disks was implemented. Relying on a robust real-time operating system, the new DAQ software adopts an object oriented design to implement the diverse tasks of trigger handling, data selection, transmission, and storage, as well as DAQ control and monitor functions. The new systems performed well during two flights in Spring 1999 and Fall 2000. In the 2000 flight, the DAQ system was able to handle 300-350 triggers/s out of a total of about 650 Hz, including charged particles.
[74]  oai:arXiv.org:astro-ph/0012297  [pdf] - 1232606
Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)
Comments: To appear in: Hard X-Ray, Gamma-Ray and Neutron Detector Physics XI, 2000; Proc. SPIE, vol. 4140; K.A. Flanagan & O.H. Siegmund, eds
Submitted: 2000-12-13
LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of 0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual \g -ray interactions within the sensitive volume. The TPC has been characterized with repeated measurements of its spectral and Compton imaging response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be. The detector shows a linear response to \g -rays in the energy range 511 keV -4.4 MeV, with an energy resolution (FWHM) of $ \Delta E/E=8.8% \: \sqrt{1\MeV /E}$. Compton imaging of \yt \g -ray events with two detected interactions is consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.
[75]  oai:arXiv.org:astro-ph/0012296  [pdf] - 1232605
Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT)
Comments: To appear in: Hard X-Ray, Gamma-Ray, and Neutron Detector Physics II, 2000; Proc. SPIE, vol. 4141; R.B. James & R.C. Schirato, eds
Submitted: 2000-12-13
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in which the three-dimensional location and energy deposit of individual \g -ray interactions are accurately measured in one homogeneous volume. To determine the \g -ray initial direction (Compton imaging), as well as to reject background, the correct sequence of interactions has to be determined. Here we report the development and optimization of an algorithm to reconstruct the Compton scattering sequence and show its performance on Monte Carlo events and LXeGRIT data.
[76]  oai:arXiv.org:astro-ph/0005372  [pdf] - 36143
Modelling Radioactivities and other Observables from OB Associations
Comments: 11 pages, 13 figures, submitted to A&A
Submitted: 2000-05-18
Recent observations of the diffuse Galactic gamma-ray glow at 1.809 MeV, attributed to the radioactive decay of 26Al, point towards a massive star origin of this radioactive isotope. Wolf Rayet stars and core-collapse supernovae appear to dominate the production of this isotope. Massive stars are commonly located in clusters and OB associations, regions of recent star formation. We thus discuss the temporal evolution of 26Al, and 60Fe within evolving OB associations. The goal of this study is to utilize the associated gamma-ray lines as a diagnostic tool for the study of correlated star formation, and also to provide more detailed models for the interpretation of data obtained with COMPTEL on the Compton Observatory. We investigate the effects of possible aluminum yield enhancements, predicted for some massive close binary systems. In addition to the ejection of chemically processed matter, massive stars also drive strong stellar winds and emit large fluxes of ionizing radiation. This energy and radiation input into the interstellar medium (ISM) is crucial for the dynamical evolution of the gas and subsequent star forming activity in the galactic disk. We discuss population synthesis models for a variety of star formation histories, and compare the predicted gamma-ray line lightcurves to COMPTEL measurements in the Cygnus region. Radioactive tracers such as 26Al and 60Fe provide a unique gamma-ray tracer of Galactic star formation activity, complementary to other methods using spectral information in the radio, IR or optical bands.
[77]  oai:arXiv.org:astro-ph/9910555  [pdf] - 109109
COMPTEL limits on 26Al 1.809 MeV line emission from gamma^2 Velorum
Comments: 7 pages, 4 figures, A&A in press
Submitted: 1999-10-29
The Wolf-Rayet binary system gamma^2 Vel (WR 11} is the closest known Wolf-Rayet (WR) star. Recently, its distance has been redetermined by parallax measurements with the HIPPARCOS astrometric satellite yielding 258^{+41}_{-31} pc, significantly lower than previous estimates (300 -- 450 pc). Wolf-Rayet stars have been proposed as a major source of the Galactic 26Al observed at 1.809 MeV. The gamma-ray telescope COMPTEL has previously reported 1.8 MeV emission from the Vela region, yet located closer to the Galactic plane than the position of gamma^2 Vel. We derive an upper 1.8 MeV flux limit of 1.1 10^{-5} ph cm^{-2} s^{-1} (2 \sigma) for the WR star. With the new distance estimate, COMPTEL measurements place a limit of (6.3^{+2.1}_{-1.4}) 10^{-5} M_\odot the 26Al yield of gamma^2 Vel, thus constrains theories of nucleosynthesis in Wolf-Rayet stars. We discuss the implications in the context of the binary nature of gamma^2 Vel and present a new interpretation of the IRAS Vela shell.
[78]  oai:arXiv.org:astro-ph/9903172  [pdf] - 105577
Image Reconstruction of COMPTEL 1.8 MeV 26Al Line Data
Comments: 13 pages, 7 figures, A&A, in press
Submitted: 1999-03-11
We present a new algorithm, called Multiresolution Regularized Expectation Maximization (MREM), for the reconstruction of gamma-ray intensity maps from COMPTEL data. The algorithm is based on the iterative Richardson-Lucy scheme to which we added a wavelet thresholding step in order to eliminate image-noise in the reconstruction. The wavelet thresholding explicitly accounts for spatial correlations in the data, and adapts the angular resolution locally, depending on the significance of the signal in the data. We compare the performance of MREM to that of the maximum entropy and the Richardson-Lucy algorithms by means of Monte-Carlo simulations of COMPTEL 1.809 MeV gamma-ray line observations. The simulations demonstrate that the maximum entropy and Richardson-Lucy algorithms provide virtually identical reconstructions which are heavily disturbed by image noise. MREM largely suppresses this noise in the reconstructions, showing only the significant structures that are present in the data. Application of MREM to COMPTEL 1.8 MeV gamma-ray line data results in a 1.809 MeV sky map that is much smoother than the maximum entropy or Richardson-Lucy reconstructions presented previously. The essential features of this map are (1) an asymmetric galactic ridge emission reaching from l=45 deg to l=240 deg, (2) a bright localised emission feature in the Cygnus region around (l,b)=(80 deg,0 deg), (3) two emission spots at l=317 deg and l=332 deg situated in the galactic plane, and (4) an extended emission region around (l,b)=(160 deg, 0 deg). Comparison of the MREM map to the simulated reconstructions demonstrates that the 1.809 MeV emission is confined to the galactic plane.
[79]  oai:arXiv.org:astro-ph/9902282  [pdf] - 105301
Assessment of Tracers of 1.8 MeV Emission
Comments: 4 pages, 1 figure, Proc. of the 3rd INTEGRAL workshop, Taormina
Submitted: 1999-02-19
We examined the question of a possible correlation between 1.8 MeV emission and intensity distributions observed at other wavelengths by comparing the 1.8 MeV data to an extended set of all-sky maps, covering the entire explored wavelength range from the radio band up to high-energy gamma-rays. This analysis revealed that tracers of the old stellar population or the local interstellar medium provide only a poor description of the data. Tracers of the young stellar population considerably improve the fit. Residuals are minimized for the free-free emission map obtained by the DMR at microwave wavelengths and the 158 um fine-structure line map of C+ observed by FIRAS. Within the statistics of the present data, both maps provide an overall satisfactory fit. We therefore conclude that adequate tracers of 26Al sources have now been identified. Implications for 26Al source types are discussed (see also Knodlseder, these proceedings).
[80]  oai:arXiv.org:astro-ph/9902283  [pdf] - 105302
A New Look at Image Reconstruction of COMPTEL 1.8 MeV Data
Comments: 4 pages, 1 figure, Proc. of the 3rd INTEGRAL workshop, Taormina
Submitted: 1999-02-19
Deconvolving COMPTEL gamma-ray data into images presents a major methodological challenge. We developed a new algorithm called Multiresolution Regularized Expectation Maximization (MREM), which explicitly accounts for spatial correlations in the image by using wavelets (Dixon et al. 1998). We demonstrate that MREM largely suppresses image noise in the reconstruction, showing only significant structures that are present in the data. Application to 1.8 MeV data results in a sky map that is much smoother than the maximum entropy reconstructions presented previously, but it shows the same characteristic emission features which have been established earlier.
[81]  oai:arXiv.org:astro-ph/9707335  [pdf] - 98159
26Al in the local interstellar medium
Comments: 4 pages, LaTeX, lamuphys macro, to be published in "Lecture Notes in Physics"
Submitted: 1997-07-30
We estimate the 1.8 MeV luminosity of the Sco-Cen association due to radioactive decay of 26Al to (4-15) 10e-5 ph cm**-2 s**-1. We propose a low surface brightness, limb brightened bubble for the 1.8 MeV intensity distribution. The detectibility of this distribution with existing gamma-ray telescopes is discussed.
[82]  oai:arXiv.org:astro-ph/9604054  [pdf] - 94425
1.8 MeV Emission from the Carina Region
Comments: 4 pages, accepted by A&AS, for further preprints see http://www.gamma.mpe-garching.mpg.de/~jrk/jrk.html
Submitted: 1996-04-11
Significant 1.8 MeV emission from the Carina region has been detected by COMPTEL. The emission is concentrated within 6 degrees or less near the Carina nebula NGC 3372, one of the brightest HII regions known in our Galaxy. This region contains a wealth of extreme young open clusters whose massive stars possibly contributed to an enrichment of 26Al in the ISM within the last few million years. The relation of these clusters and the peculiar object Eta Carinae with the observed emission is discussed. The 26Al yield of the clusters is estimated using current theoretical nucleosynthesis models.
[83]  oai:arXiv.org:astro-ph/9604053  [pdf] - 94424
Modelling the 1.8 MeV Sky: Tests for Spiral Structure
Comments: For further preprints see http://www.gamma.mpe-garching.mpg.de/~jrk/jrk.html
Submitted: 1996-04-11
COMPTEL imaging analysis revealed a patchy, asymmetric distribution of diffuse 1.8 MeV emission along the Galactic plane, which is attributed to the decay of radioactive 26Al in the ISM. If massive stars were the major source of Galactic 26Al, the 1.8 MeV emission should be asymmetric and trace the spiral arms of the Galaxy, presumed site of massive star formation. Using model fits, we indeed find weak evidence in the COMPTEL data that the observed 1.8 MeV emission is at least partly confined to spiral arms. We derive a total Galactic 26Al mass of 2.5 Msol from which at least 0.7 Msol can be attributed to massive stars.
[84]  oai:arXiv.org:astro-ph/9604057  [pdf] - 94428
Search for 1.809 MeV Emission of 26Al from nearby Supernova Remnants using COMPTEL
Comments: 4 pages, accepted for publication in A&AS
Submitted: 1996-04-11
We report the negative results of our searches in COMPTEL data for 1.809 MeV gamma-ray line emission from four localized regions which contain nearby supernova remnants (SNRs). The upper flux limits (2 Sigma) are found to be in the range of 1.4*10e-5 to 2.4*10e-5 photons/s/cm/cm. These upper limits do not severely constrain the theoretical 26Al yields from individual core collapse supernovae due to large uncertainties in the SNR distances and the nature of the progenitor stars.