Normalized to: Nozka, L.
[1]
oai:arXiv.org:1911.05285 [pdf] - 2054070
The First Full-Scale Prototypes of the Fluorescence detector Array of
Single-pixel Telescopes
Malacari, M.;
Farmer, J.;
Fujii, T.;
Albury, J.;
Bellido, J. A.;
Chytka, L.;
Hamal, P.;
Horvath, P.;
Hrabovsky, M.;
Mandat, D.;
Matthews, J. N.;
Nozka, L.;
Palatka, M.;
Pech, M.;
Privitera, P.;
Schovanek, P.;
Smida, R.;
Thomas, S. B.;
Travnicek, P.
Submitted: 2019-11-12
The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design
concept for a next-generation UHECR observatory, addressing the requirements
for a large-area, low-cost detector suitable for measuring the properties of
ultra-high energy cosmic rays (UHECRs), having energies exceeding
$10^{19.5}$\,eV, with an unprecedented aperture. We have developed a full-scale
prototype consisting of four 200\,mm diameter photo-multiplier tubes at the
focus of a segmented mirror of 1.6\,m in diameter. In October 2016, September
2017, and September 2018 we installed three such prototypes at the Black Rock
Mesa site of the Telescope Array experiment in central Utah, USA. All three
telescopes have been steadily taking data since installation. We report on the
design and installation of these prototypes, and present some preliminary
results, including measurements of artificial light sources, distant
ultraviolet lasers, and UHECRs. Furthermore, we discuss some additional uses
for these simplified low-cost fluorescence telescopes, including the
facilitation of a systematic comparison of the transparency of the atmosphere
above the Telescope Array experiment and the Pierre Auger Observatory, a study
of the systematic uncertainty associated with the existing fluorescence
detectors of these two experiments, and a cross-calibration of their energy and
$X_{\text{max}}$ scales.
[2]
oai:arXiv.org:1908.02904 [pdf] - 1931542
Observing ultra-high energy cosmic rays with prototypes of the
Fluorescence detector Array of Single-pixel Telescopes (FAST) in both
hemispheres
Fujii, Toshihiro;
Malacari, Max;
Farmer, John;
Albury, Justin;
Bellido, Jose A.;
Chytka, Ladislav;
Hamal, Petr;
Horvath, Pavel;
Hrabovsky, Miroslav;
Kvita, Jiri;
Mandat, Dusan;
Mastrodicasa, Massimo;
Matthews, John N.;
Michal, Stanislav;
Ni, Xiaochen;
Nozka, Libor;
Palatka, Miroslav;
Pech, Miroslav;
Privitera, Paolo;
Schovanek, Petr;
Salamida, Francesco;
Smida, Radomir;
Thomas, Stan B.;
Travnicek, Petr;
Vacula, Martin
Submitted: 2019-08-07
The origin and nature of ultra-high energy cosmic rays (UHECRs) are hot
topics in the astroparticle physics community. The Fluorescence detector Array
of Single-pixel Telescopes (FAST) is a design for a next-generation
ground-based UHECR observatory, addressing the requirements for a large-area,
low-cost detector suitable for measuring the properties of the highest energy
cosmic rays with an unprecedented aperture. We have developed a full-scale
prototype consisting of four 200 mm photomultiplier tubes at the focus of a
segmented mirror of 1.6 m in diameter. Over the last three years, we have
installed three prototypes at the Telescope Array Experiment in Utah, USA.
These telescopes have been steadily taking data since installation. We report
on preliminary results of the full-scale FAST prototypes, including
measurements of UHECRs, and distant ultra-violet lasers used to study the
atmospheric transparency. Furthermore, we discuss the installation of an
additional identical FAST prototype at the Pierre Auger Observatory in
Argentina. Possible benefits to the Telescope Array Experiment and the Pierre
Auger Observatory include a comparison of the transparency of the atmosphere
above both experiments, a study of the systematic uncertainty associated with
their existing fluorescence detectors, and a cross-calibration of their energy
and Xmax scales.
[3]
oai:arXiv.org:1708.01379 [pdf] - 1586763
The Fluorescence detector Array of Single-pixel Telescopes:
Contributions to the 35th International Cosmic Ray Conference (ICRC 2017)
Fujii, Toshihiro;
Malacari, Max;
Albury, Justin;
Bellido, Jose A.;
Farmer, John;
Galimova, Aygul;
Horvath, Pavel;
Hrabovsky, Miroslav;
Mandat, Dusan;
Matalon, Ariel;
Matthews, John N.;
Merolle, Maria;
Ni, Xiaochen;
Nozka, Libor;
Palatka, Miroslav;
Pech, Miroslav;
Privitera, Paolo;
Schovanek, Petr;
Thomas, Stan B.;
Travnicek, Petr
Submitted: 2017-08-04
Contributions of the Fluorescence detector Array of Single-pixel Telescopes
(FAST) to the 35th International Cosmic Ray Conference, 12-20 July 2017, Busan,
Korea
[6]
oai:arXiv.org:1210.6734 [pdf] - 1152436
Precise measurement of the absolute fluorescence yield of the 337 nm
band in atmospheric gases
AIRFLY Collaboration;
Ave, M.;
Bohacova, M.;
Curry, E.;
Di Carlo, P.;
Di Giulio, C.;
Luis, P. Facal San;
Gonzales, D.;
Hojvat, C.;
Hörandel, J.;
Hrabovsky, M.;
Iarlori, M.;
Keilhauer, B.;
Klages, H.;
Kleifges, M.;
Kuehn, F.;
Li, S.;
Monasor, M.;
Nozka, L.;
Palatka, M.;
Petrera, S.;
Privitera, P.;
Ridky, J.;
Rizi, V.;
D'Orfeuil, B. Rouille;
Salamida, F.;
Schovanek, P.;
Smida, R.;
Spinka, H.;
Ulrich, A.;
Verzi, V.;
Williams, C.
Submitted: 2012-10-24
A measurement of the absolute fluorescence yield of the 337 nm nitrogen band,
relevant to ultra-high energy cosmic ray (UHECR) detectors, is reported. Two
independent calibrations of the fluorescence emission induced by a 120 GeV
proton beam were employed: Cherenkov light from the beam particle and
calibrated light from a nitrogen laser. The fluorescence yield in air at a
pressure of 1013 hPa and temperature of 293 K was found to be $Y_{337} =
5.61\pm 0.06_{stat} \pm 0.21_{syst}$ photons/MeV. When compared to the
fluorescence yield currently used by UHECR experiments, this measurement
improves the uncertainty by a factor of three, and has a significant impact on
the determination of the energy scale of the cosmic ray spectrum.
[7]
oai:arXiv.org:0706.1710 [pdf] - 1934133
New method for atmospheric calibration at the Pierre Auger Observatory
using FRAM, a robotic astronomical telescope
BenZvi, Segev;
Bohacova, Martina;
Connolly, Brian;
Grygar, Jiri;
Hrabovsky, Miroslav;
Karova, Tatiana;
Mandat, Dusan;
Necesal, Petr;
Nosek, Dalibor;
Nozka, Libor;
Palatka, Miroslav;
Pech, Miroslav;
Prouza, Michael;
Ridky, Jan;
Schovanek, Petr;
Smida, Radomir;
Travnicek, Petr;
Vitale, Primo;
Westerhoff, Stefan
Submitted: 2007-06-12
FRAM - F/(Ph)otometric Robotic Atmospheric Monitor is the latest addition to
the atmospheric monitoring instruments of the Pierre Auger Observatory. An
optical telescope equipped with CCD camera and photometer, it automatically
observes a set of selected standard stars and a calibrated terrestrial source.
Primarily, the wavelength dependence of the attenuation is derived and the
comparison between its vertical values (for stars) and horizontal values (for
the terrestrial source) is made. Further, the integral vertical aerosol optical
depth can be obtained. A secondary program of the instrument, the detection of
optical counterparts of gamma-ray bursts, has already proven successful. The
hardware setup, software system, data taking procedures, and first analysis
results are described in this paper.