Normalized to: Noble, T.
[1]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[2]
oai:arXiv.org:1211.0909 [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Boudjemline, K.;
Caldwell, M. G. Boulay B. Cai T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Contreras, D.;
Dering, K.;
Duncan, F.;
Ford, R.;
Giuliani, R. Gagnon F.;
Golovko, M. Gold V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Lidgard, J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McKinsey, D.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, T.;
O'Dwyer, E.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Pollmann, T.;
Rau, W.;
Retiere, F.;
Ronquest, M.;
Skensved, P.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Ward, M.
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry.