Normalized to: Niwa, K.
[1]
oai:arXiv.org:1711.01544 [pdf] - 1669503
First demonstration of gamma-ray imaging using balloon-borne emulsion
telescope
Rokujo, Hiroki;
Aoki, Shigeki;
Hamada, Kaname;
Hara, Toshio;
Inoue, Tatsuki;
Ishiguro, Katsumi;
Iyono, Atsushi;
Kawahara, Hiroaki;
Kodama, Koichi;
Komatani, Ryosuke;
Komatsu, Masahiro;
Kosaka, Tetsuya;
Mizutani, Fukashi;
Miyanishi, Motoaki;
Morishima, Kunihiro;
Morishita, Misaki;
Nakamura, Mitsuhiro;
Nakano, Toshiyuki;
Nishio, Akira;
Niwa, Kimio;
Otsuka, Naoto;
Ozaki, Keita;
Sato, Osamu;
Shibayama, Emi;
Takahashi, Satoru;
Suzuki, Atsumu;
Tanaka, Ryo;
Tateishi, Yurie;
Tawa, Shuichi;
Yabu, Misato;
Yamada, Kyohei;
Yamamoto, Saya;
Yoshimoto, Masahiro
Submitted: 2017-11-05, last modified: 2018-04-21
We promote the precise gamma-ray observation project Gamma-Ray Astro-Imager
with Nuclear Emulsion (GRAINE), which uses balloon-borne emulsion gamma-ray
telescopes. The emulsion telescope realizes observations with high angular
resolution, polarization sensitivity, and large aperture area in the 0.01--100
GeV energy region. Herein, we report the data analysis of emulsion tracks and
the first demonstration of gamma-ray imaging via an emulsion telescope by using
the flight data from the balloon experiment performed in 2015 (GRAINE 2015).
The emulsion films were scanned by the latest read-out system for a total area
of 41 m$^2$ in three months, and then the gamma-ray event selection was
automatically processed. Millions of electron-pair events are accumulated in
the balloon-borne emulsion telescope. The emulsion telescope detected signals
from a calibration source (gamma rays from the interaction of cosmic rays with
an aluminum plate) with a high significance during the balloon observation and
created a gamma-ray image consistent with the source size and the expected
angular resolution in the energy range of 100--300 MeV. The flight performance
obtained in the GRAINE 2015 experiment proves that balloon-borne emulsion
telescope experiments with larger area are feasible while maintaining expected
imaging performance.
[2]
oai:arXiv.org:1202.2529 [pdf] - 475837
Balloon-borne gamma-ray telescope with nuclear emulsion : overview and
status
Aoki, Shigeki;
Fukuda, Tsutomu;
Hamada, Kaname;
Hara, Toshio;
Iyono, Atsushi;
Kawada, Jiro;
Kazuyama, Masashi;
Kodama, Koichi;
Komatsu, Masahiro;
Koshiba, Shinichiro;
Kubota, Hirotaka;
Miyamoto, Seigo;
Miyanishi, Motoaki;
Morishima, Kunihiro;
Naganawa, Naotaka;
Naka, Tatsuhiro;
Nakamura, Mitsuhiro;
Nakano, Toshiyuki;
Niwa, Kimio;
Nonoyama, Yoshiaki;
Ozaki, Keita;
Rokujo, Hiroki;
Sako, Takashi;
Sato, Osamu;
Sato, Yoshihiro;
Suzuki, Atsumu;
Suzuki, Kazuya;
Takahashi, Satoru;
Tezuka, Ikuo;
Yoshida, Junya;
Yoshioka, Teppei
Submitted: 2012-02-12
Detecting the first electron pairs with nuclear emulsion allows a precise
measurement of the direction of incident gamma-rays as well as their
polarization. With recent innovations in emulsion scanning, emulsion analyzing
capability is becoming increasingly powerful. Presently, we are developing a
balloon-borne gamma-ray telescope using nuclear emulsion. An overview and a
status of our telescope is given.
[3]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.