Normalized to: Niko, H.
[1]
oai:arXiv.org:astro-ph/0611232 [pdf] - 1233970
Hard X-ray Detector (HXD) on Board Suzaku
Takahashi, T.;
Abe, K.;
Endo, M.;
Endo, Y.;
Ezoe, Y.;
Fukazawa, Y.;
Hamaya, M.;
Hirakuri, S.;
Hong, S.;
Horii, M.;
Inoue, H.;
Isobe, N.;
Itoh, T.;
Iyomoto, N.;
Kamae, T.;
Kasama, D.;
Kataoka, J.;
Kato, H.;
Kawaharada, M.;
Kawano, N.;
Kawashima, K.;
Kawasoe, S.;
Kishishita, T.;
Kitaguchi, T.;
Kobayashi, Y.;
Kokubun, M.;
Kotoku, J.;
Kouda, M.;
Kubota, A.;
Kuroda, Y.;
Madejski, G.;
Makishima, K.;
Masukawa, K.;
Matsumoto, Y.;
Mitani, T.;
Miyawaki, R.;
Mizuno, T.;
Mori, K.;
Mori, M.;
Murashima, M.;
Murakami, T.;
Nakazawa, K.;
Niko, H.;
Nomachi, M.;
Okada, Y.;
Ohno, M.;
Oonuki, K.;
Ota, N.;
Ozawa, H.;
Sato, G.;
Shinoda, S.;
Sugiho, M.;
Suzuki, M.;
Taguchi, K.;
Takahashi, H.;
Takahashi, I.;
Takeda, S.;
Tamura, K.;
Tamura, T.;
Tanaka, T.;
Tanihata, C.;
Tashiro, M.;
Terada, Y.;
Tominaga, S.;
Uchiyama, Y.;
Watanabe, S.;
Yamaoka, K.;
Yanagida, T.;
Yonetoku, D.
Submitted: 2006-11-07
The Hard X-ray Detector (HXD) on board Suzaku covers a wide energy range from
10 keV to 600 keV by combination of silicon PIN diodes and GSO scintillators.
The HXD is designed to achieve an extremely low in-orbit back ground based on a
combination of new techniques, including the concept of well-type active shield
counter. With an effective area of 142 cm^2 at 20 keV and 273 cm2 at 150 keV,
the background level at the sea level reached ~1x10^{-5} cts s^{-1} cm^{-2}
keV^{-1} at 30 keV for the PI N diodes, and ~2x10^{-5} cts s^{-1} cm^{-2}
keV^{-1} at 100 keV, and ~7x10^{-6} cts s^{-1} cm^{-2} keV^{-1} at 200 keV for
the phoswich counter. Tight active shielding of the HXD results in a large
array of guard counters surrounding the main detector parts. These
anti-coincidence counters, made of ~4 cm thick BGO crystals, have a large
effective area for sub-MeV to MeV gamma-rays. They work as an excellent
gamma-ray burst monitor with limited angular resolution (~5 degree). The
on-board signal-processing system and the data transmitted to the ground are
also described.
[2]
oai:arXiv.org:astro-ph/0601491 [pdf] - 79349
A Further Study of the Luminosity-Dependent Cyclotron Resonance Energies
of the Binary X-ray Pulsar 4U0115+63 with RXTE
Submitted: 2006-01-21
The present paper reports on the RXTE observations of the binary X-ray pulsar
4U0115+63, covering an outburst in 1999 March-April with 44 pointings. The 3-30
keV PCA spectra and the 15-50 keV HEXTE spectra were analyzed jointly for the
cyclotron resonance features. When the 3-50 keV luminosity at an assumed
distance of 7 kpc was in the range (5-13)x10^{37} erg s^{-1}, harmonic double
cyclotron features were observed in absorption at ~11 and ~22 keV, as was
measured previously during typical outbursts. As the luminosity decreased below
\~5x10^{37} erg s^{-1}, the second resonance disappeared, and the fundamental
resonance energy gradually increased, up to $\sim$16 keV at 0.16x10^{37} erg
s^{-1}. These results reconfirm the report by Mihara et al. (2004) using Ginga,
who observed a single absorption at ~16 keV in a minor (~10^{37} erg s^{-1})
outburst of this object. The luminosity-dependent cyclotron resonance energy
may be understood as a result of a decrease in the accretion column height, in
response to a decrease in the mass accretion rate.
[3]
oai:arXiv.org:astro-ph/0406449 [pdf] - 65606
A search for cyclotron resonance features with INTEGRAL
Submitted: 2004-06-21
We present an INTEGRAL observation of the Cen-Crux region in order to search
the electron cyclotron resonance scattering features from the X-ray binary
pulsars. During the AO1 200ks observation, we clearly detected 4 bright X-ray
binaries, 1 Seyfert Galaxy, and 4 new sources in the field of view. Especially
from GX301-2, the cyclotron resonance feature is detected at about 37 keV, and
width of 3--4 keV. In addition, the depth of the resonance feature strongly
depends on the X-ray luminosity. This is the first detection of luminosity
dependence of the resonance depth. The cyclotron resonance feature is
marginally detected from 1E1145.1-6141. Cen X-3 was very dim during the
observation and poor statistics disable us to detect the resonance
features.These are first INTEGRAL results of searching for the cyclotron
resonance feature.