Normalized to: Nikkel, J.
[3]
oai:arXiv.org:0904.2930 [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape
discrimination of low-energy beta and nuclear recoils in liquid argon with
DEAP-1
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boudjemline, K.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
Duncan, F.;
Fatemighomi, N.;
Ford, R.;
Gagnon, R.;
Giampa, P.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Hearns, C.;
Hofgartner, J.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
La Zia, F.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Mehdiyev, R.;
McKinsey, D. N.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, A. J.;
O'Dwyer, E.;
Olsen, K.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Ronquest, M.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be $<1.4\times
10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
$<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming
negligible contribution from nuclear recoil backgrounds.
[4]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[5]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[6]
oai:arXiv.org:1211.0909 [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Boudjemline, K.;
Caldwell, M. G. Boulay B. Cai T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Contreras, D.;
Dering, K.;
Duncan, F.;
Ford, R.;
Giuliani, R. Gagnon F.;
Golovko, M. Gold V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Lidgard, J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McKinsey, D.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, T.;
O'Dwyer, E.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Pollmann, T.;
Rau, W.;
Retiere, F.;
Ronquest, M.;
Skensved, P.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Ward, M.
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry.
[7]
oai:arXiv.org:1403.4842 [pdf] - 799232
Update on the MiniCLEAN Dark Matter Experiment
Rielage, K.;
Akashi-Ronquest, M.;
Bodmer, M.;
Bourque, R.;
Buck, B.;
Butcher, A.;
Caldwell, T.;
Chen, Y.;
Coakley, K.;
Flores, E.;
Formaggio, J. A.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Grace, E.;
Griego, J.;
Guerrero, N.;
Guiseppe, V.;
Henning, R.;
Hime, A.;
Jaditz, S.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Latorre, A.;
Lawson, I.;
Linden, S.;
Lopez, F.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mei, D. -M.;
Monroe, J.;
Nikkel, J. A.;
Oertel, J.;
Gann, G. D. Orebi;
Palladino, K.;
Perumpilly, G.;
Rodriguez, L.;
Schnee, R.;
Seibert, S.;
Walding, J.;
Wang, B.;
Wang, J.;
Zhang, C.
Submitted: 2014-03-19
The direct search for dark matter is entering a period of increased
sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One
such technology that is being examined is a scintillation only noble liquid
experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to
detect nuclear recoils from WIMP dark matter and serves as a demonstration for
a future detector of order 50 to 100 tonnes. The liquid cryogen is
interchangeable between argon and neon to study the A$^{2}$ dependence of the
potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular
design with spherical geometry to maximize the light yield using cold
photomultiplier tubes in a single-phase detector. Pulse shape discrimination
techniques are used to separate nuclear recoil signals from electron recoil
backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate
the effective reach of the pulse shape discrimination capability. Assembly of
the experiment is underway at SNOLAB and an update on the project is given.
[8]
oai:arXiv.org:1310.8214 [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford
Underground Research Facility
LUX Collaboration;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Clark, K.;
Coffey, T.;
Currie, A.;
Curioni, A.;
Dazeley, S.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Dragowsky, E. M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hanhardt, M.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Kyre, S.;
Lander, R.;
Larsen, N. A.;
Lee, C.;
Leonard, D. S.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Morii, M.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Sofka, C. J.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
O`Sullivan, K.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
White, D.;
Witherell, M. S.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
[9]
oai:arXiv.org:1205.2272 [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Chan, Y-D.;
Clark, K.;
Coffey, T.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Larsen, N.;
Lee, C.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Thomson, J.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of
photomultiplier tubes designed for use in current and future liquid xenon
experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark
matter experiment, has yielded a positive detection of four common radioactive
isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered
backgrounds from other detector materials subdominant to the R8778
contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also
been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th
/ <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to
a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT,
between R8778 and R11410 MOD, concurrent with a doubling of the photocathode
surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable
between the PMTs, but can be significantly reduced in future R11410 MOD units
through further material selection. Assuming PMT activity equal to the measured
90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs
with R11410 MOD PMTs will change LUX PMT electron recoil background
contributions by a factor of \times1/25 after further material selection for
60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The
strong reduction in backgrounds below the measured R8778 levels makes the
R11410 MOD a very competitive technology for use in large-scale liquid xenon
detectors.
[10]
oai:arXiv.org:1210.4569 [pdf] - 630139
Technical Results from the Surface Run of the LUX Dark Matter Experiment
LUX Collaboration;
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chapman, J. J.;
Coffey, T.;
Dobi, A.;
Dragowsky, E.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Gilchriese, M.;
Hall, C.;
Hanhardt, M.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Larsen, N.;
Lee, C.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Moongweluwan, M.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Rodionov, A.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
de Viveiros, L.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-10-16, last modified: 2013-02-22
We present the results of the three-month above-ground commissioning run of
the Large Underground Xenon (LUX) experiment at the Sanford Underground
Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid
xenon detector that will search for cold dark matter in the form of Weakly
Interacting Massive Particles (WIMPs). The commissioning run, conducted with
the detector immersed in a water tank, validated the integration of the various
sub-systems in preparation of the underground deployment. Using the data
collected, we report excellent light collection properties, achieving 8.4
photoelectrons per keV for 662 keV electron recoils without an applied electric
field, measured in the center of the WIMP target. We also find good energy and
position resolution in relatively high-energy interactions from a variety of
internal and external sources. Finally, we have used the commissioning data to
tune the optical properties of our simulation and report updated sensitivity
projections for spin-independent WIMP-nucleon scattering.
[11]
oai:arXiv.org:1207.3665 [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Cahn, S.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, C. E.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Fiorucci, S.;
Gaitskell, R. J.;
Hall, C.;
Faham, C.;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Kwong, J.;
Lander, R.;
Leonard, D.;
Malling, D.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nikkel, J.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Steigler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
[12]
oai:arXiv.org:1111.3260 [pdf] - 548322
Scintillation yield and time dependence from electronic and nuclear
recoils in liquid neon
Submitted: 2011-11-14, last modified: 2012-08-13
We have performed measurements of scintillation light in liquid neon,
observing a signal yield in our detector as high as (3.5 $\pm$ 0.4)
photoelectrons/keV. We measure pulse shape discrimination efficiency between
electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear
recoil energy. We also measure the \leff\, parameter in liquid neon between 30
and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50
keV. We observe a dependence of the scintillation time distribution and signal
yield on the pressure and temperature of the liquid neon.
[13]
oai:arXiv.org:1004.0373 [pdf] - 672810
Measurement of scintillation efficiency for nuclear recoils in liquid
argon
Submitted: 2010-04-02, last modified: 2012-05-08
The scintillation light yield of liquid argon from nuclear recoils relative
to electronic recoils has been measured as a function of recoil energy from 10
keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the
nuclear recoil scintillation response to the electronic recoil response, is
0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
[14]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[15]
oai:arXiv.org:1109.5649 [pdf] - 1084392
Scintillation and charge extraction from the tracks of energetic
electrons in superfluid helium-4
Submitted: 2011-09-26
An energetic electron passing through liquid helium causes ionization along
its track. The ionized electrons quickly recombine with the resulting positive
ions, which leads to the production of prompt scintillation light. By applying
appropriate electric fields, some of the ionized electrons can be separated
from their parent ions. The fraction of the ionized electrons extracted in a
given applied field depends on the separation distance between the electrons
and the ions. We report the determination of the mean electron-ion separation
distance for charge pairs produced along the tracks of beta particles in
superfluid helium at 1.5 K by studying the quenching of the scintillation light
under applied electric fields. Knowledge of this mean separation parameter will
aid in the design of particle detectors that use superfluid helium as a target
material.
[16]
oai:arXiv.org:1108.1836 [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
[17]
oai:arXiv.org:0912.0482 [pdf] - 902613
Status of the LUX Dark Matter Search
Fiorucci, S.;
Akerib, D. S.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Carr, D.;
Chapman, J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, E.;
Dazeley, S.;
de Viveiros, L.;
Druszkiewicz, E.;
Gaitskell, R.;
Hall, C.;
Faham, C. Hernandez;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Lesko, K.;
Malling, D.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Nikkel, J.;
Phelps, P.;
Schroeder, U.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Toke, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F.;
Woods, M.;
Zhang, C.
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently
being deployed at the Homestake Laboratory in South Dakota. We will highlight
the main elements of design which make the experiment a very strong competitor
in the field of direct detection, as well as an easily scalable concept. We
will also present its potential reach for supersymmetric dark matter detection,
within various timeframes ranging from 1 year to 5 years or more.
[18]
oai:arXiv.org:0911.5453 [pdf] - 146838
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Submitted: 2009-11-30
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration
source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are
produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$
scintillation peak at 41.5 keV appears in both liquids when filling our
detector through a piece of zeolite coated with $^{83}$Rb. Based on this
scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a
resolution of 6% ($\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a
resolution of 19% ($\sigma$/E). The observed peak intensity subsequently decays
with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we
find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in
the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful
calibration source for liquid argon and neon dark matter and solar neutrino
detectors.
[19]
oai:arXiv.org:0709.1880 [pdf] - 4868
Detection and Imaging of He_2 Molecules in Superfluid Helium
Submitted: 2007-09-12, last modified: 2007-12-18
We present data that show a cycling transition can be used to detect and
image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate
that limitations on the cycling efficiency due to the vibrational structure of
the molecule can be mitigated by the use of repumping lasers. Images of the
molecules obtained using the method are also shown. This technique gives rise
to a new kind of ionizing radiation detector. The use of He$_2$ triplet
molecules as tracer particles in the superfluid promises to be a powerful tool
for visualization of both quantum and classical turbulence in liquid helium.
[20]
oai:arXiv.org:astro-ph/0702202 [pdf] - 89256
Demonstration of photomultiplier tube operation at 29 K
Submitted: 2007-02-07
We describe measurements of gain, dark current, and quantum efficiency
obtained while cooling a Hamamatsu R5912-02-MOD photomultiplier tube from room
temperature to 29 K. We found that the PMT operated normally down to 29 K, with
a reduced gain and quantum efficiency at the lowest temperatures. Furthermore,
we found that the dark count rate increased as the temperature decreased. We
conclude that these PMTs appear to be adequate for the requirements of the
CLEAN experiment.
[21]
oai:arXiv.org:astro-ph/0612108 [pdf] - 87446
Scintillation of liquid neon from electronic and nuclear recoils
Submitted: 2006-12-04
We have measured the time dependence of scintillation light from electronic
and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2
us. Pulse shape discrimination is investigated as a means of identifying event
type in liquid neon. Finally, the nuclear recoil scintillation efficiency is
measured to be 0.26+-0.03 for 387 keV nuclear recoils.
[22]
oai:arXiv.org:nucl-ex/0503006 [pdf] - 118468
Trace Detection of Metastable Helium Molecules in Superfluid Helium by
Laser-Induced Fluorescence
Submitted: 2005-03-11
We describe an approach to detecting ionizing radiation that combines the
special properties of superfluid helium with the sensitivity of quantum optics
techniques. Ionization in liquid helium results in the copious production of
metastable helium molecules, which can be detected by laser-induced
fluorescence. Each molecule can be probed many times using a cycling
transition, resulting in the detection of individual molecules with high signal
to noise. This technique could be used to detect neutrinos, weakly interacting
massive particles, and ultracold neutrons, and to image superfluid flow in
liquid He-4.