Normalized to: Nikam, V.
[1]
oai:arXiv.org:1702.08624 [pdf] - 1581666
Calibration of the Large Area X-ray Proportional Counter (LAXPC)
instrument on-board AstroSat
Antia, H. M.;
Yadav, J. S.;
Agrawal, P. C.;
Chauhan, Jai Verdhan;
Manchanda, R. K.;
Chitnis, Varsha;
Paul, Biswajit;
Dedhia, Dhiraj;
Shah, Parag;
Gujar, V. M.;
Katoch, Tilak;
Kurhade, V. N.;
Madhwani, Pankaj;
Manojkumar, T. K.;
Nikam, V. A.;
Pandya, A. S.;
Parmar, J. V.;
Pawar, D. M.;
Pahari, Mayukh;
Misra, Ranjeev;
Navalgund, K. H.;
Pandiyan, R.;
Sharma, K. S.;
Subbarao, K.
Submitted: 2017-02-27, last modified: 2017-06-18
We present the calibration and background model for the Large Area X-ray
Proportional Counter (LAXPC) detectors on-board AstroSat. LAXPC instrument has
three nominally identical detectors to achieve large collecting area. These
detectors are independent of each other and in the event analysis mode, they
record the arrival time and energy of each photon that is detected. The
detectors have a time-resolution of 10 $\mu$s and a dead-time of about 42
$\mu$s. This makes LAXPC ideal for timing studies. The energy resolution and
peak channel to energy mapping were obtained from calibration on ground using
radioactive sources coupled with GEANT4 simulations of the detectors. The
response matrix was further refined from observations of the Crab X-ray source
after launch. At around 20 keV the energy resolution of detector is about
10--15\%, while the combined effective area of the 3 detectors is about 6000
cm$^2$.
[2]
oai:arXiv.org:1705.06446 [pdf] - 1583573
Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and
Some Preliminary Results from its performance in the orbit
Agrawal, P. C.;
Yadav, J. S.;
Antia, H. M.;
Dedhia, Dhiraj;
Shah, P.;
Chauhan, Jai Verdhan;
Manchanda, R. K.;
Chitnis, V. R.;
Gujar, V. M.;
Katoch, Tilak;
Kurhade, V. N.;
Madhwani, P.;
Manojkumar, T. K.;
Nikam, V. A.;
Pandya, A. S.;
Parmar, J. V.;
Pawar, D. M.;
Roy, Jayashree;
Paul, B.;
Pahari, Mayukh;
Misra, Ranjeev;
Ravichandran, M. H.;
Anilkumar, K.;
Joseph, C. C.;
Navalgund, K. H.;
Pandiyan, R.;
Sarma, K. S.;
Subbarao, K.
Submitted: 2017-05-18, last modified: 2017-05-25
Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is
aimed at providing high time resolution X-ray observations in 3 to 80 keV
energy band with moderate energy resolution. To achieve large collecting area,
a cluster of three co-aligned identical LAXPC detectors, is used to realize an
effective area in access of about 6000 cm2 at 15 keV. The large detection
volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere
pressure, results in detection efficiency greater than 50%, above 30 keV. In
this article, we present salient features of the LAXPC detectors, their testing
and characterization in the laboratory prior to launch and calibration in the
orbit. Some preliminary results on timing and spectral characteristics of a few
X-ray binaries and other type of sources, are briefly discussed to demonstrate
that the LAXPC instrument is performing as planned in the orbit.