Normalized to: Nico, J.
[1]
oai:arXiv.org:1510.07607 [pdf] - 1341921
Development and Characterization of a High Sensitivity Segmented Fast
Neutron Spectrometer (FaNS-2)
Submitted: 2015-10-26
We present the development of a segmented fast neutron spectrometer (FaNS-2)
based upon plastic scintillator and $^3$He proportional counters. It was
designed to measure both the flux and spectrum of fast neutrons in the energy
range of few MeV to 1 GeV. FaNS-2 utilizes capture-gated spectroscopy to
identify neutron events and reject backgrounds. Neutrons deposit energy in the
plastic scintillator before capturing on a $^3$He nucleus in the proportional
counters. Segmentation improves neutron energy reconstruction while the large
volume of scintillator increases sensitivity to low neutron fluxes. A main goal
of its design is to study comparatively low neutron fluxes, such as cosmogenic
neutrons at the Earth's surface, in an underground environment, or from
low-activity neutron sources. In this paper, we present details of its design
and construction as well as its characterization with a calibrated $^{252}$Cf
source and monoenergetic neutron fields of 2.5 MeV and 14 MeV. Detected
monoenergetic neutron spectra are unfolded using a Singular Value Decomposition
method, demonstrating a 5% energy resolution at 14 MeV. Finally, we discuss
plans for measuring the surface and underground cosmogenic neutron spectra with
FaNS-2.