Normalized to: Nicklin, G.
[1]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[2]
oai:arXiv.org:0809.1831 [pdf] - 16182
First measurement of the Head-Tail directional nuclear recoil signature
at energies relevant to WIMP dark matter searches
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. StJ.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-09-10
We present first evidence for the so-called Head-Tail asymmetry signature of
neutron-induced nuclear recoil tracks at energies down to 1.5 keV/amu using the
1m^3 DRIFT-IIc dark matter detector. This regime is appropriate for recoils
induced by Weakly Interacting Massive Particle (WIMPs) but one where the
differential ionization is poorly understood. We show that the distribution of
recoil energies and directions induced here by Cf-252 neutrons matches well
that expected from massive WIMPs. The results open a powerful new means of
searching for a galactic signature from WIMPs.
[3]
oai:arXiv.org:0807.3969 [pdf] - 14845
Measurement of the Range Component Directional Signature in a DRIFT-II
Detector using 252Cf Neutrons
Burgos, S.;
Daw, E.;
Forbes, J.;
Ghag, C.;
Gold, M.;
Hagemann, C.;
Kudryavtsev, V. A.;
Lawson, T. B.;
Loomba, D.;
Majewski, P.;
Muna, D.;
Murphy, A. St. J.;
Nicklin, G. G.;
Paling, S. M.;
Petkov, A.;
Plank, S. J. S.;
Robinson, M.;
Sanghi, N.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Turk, J.;
Tziaferi, E.
Submitted: 2008-07-24
The DRIFT collaboration utilizes low pressure gaseous detectors to search for
WIMP dark matter with directional signatures. A 252Cf neutron source was placed
on each of the principal axes of a DRIFT detector in order to test its ability
to measure directional signatures from the three components of very low energy
(~keV/amu) recoil ranges. A high trigger threshold and the event selection
procedure ensured that only sulfur recoils were analyzed. Sulfur recoils
produced in the CS2 target gas by the 252Cf source closely match those expected
from massive WIMP induced sulfur recoils. For each orientation of the source a
directional signal from the range components was observed, indicating that the
detector is directional along all 3 axes. An analysis of these results yields
an optimal orientation for DRIFT detectors when searching for a directional
signature from WIMPs. Additional energy dependent information is provided to
aid in understanding this effect.
[4]
oai:arXiv.org:astro-ph/0701858 [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase
xenon detector for dark matter detection
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Cashmore, R. J.;
Chagani, H.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Gao, J.;
Ghag, C.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Korolkova, E. V.;
Kudryavtsev, V. A.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Neves, F.;
Nicklin, G. G.;
Ooi, W.;
Paling, S. M.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R. M.;
Quenby, J. J.;
Robinson, M.;
Sergiampietri, F.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F. L. H.
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[5]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[6]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.