Normalized to: Nicholas, J.
[1]
oai:arXiv.org:1704.05108 [pdf] - 1582613
Recovery of Bennu's Orientation for the OSIRIS-REx Mission: Implications
for the Spin State Accuracy and Geolocation Errors
Submitted: 2017-04-17
The goal of the OSIRIS-REx mission is to return a sample of asteroid material
from Near-Earth Asteroid (101955) Bennu. The role of the navigation and flight
dynamics team is critical for the spacecraft to execute a precisely planned
sampling maneuver over a specifically-selected landing site. In particular, the
orientation of Bennu needs to be recovered with good accuracy during orbital
operations to contribute as small an error as possible to the landing error
budget. Although Bennu is well characterized from Earth-based radar
observations, its orientation dynamics are not sufficiently known to exclude
the presence of a small wobble. To better understand this contingency and
evaluate how well the orientation can be recovered in the presence of a large
1$^{\circ}$ wobble, we conduct a comprehensive simulation with the NASA GSFC
GEODYN orbit determination and geodetic parameter estimation software. We
describe the dynamic orientation modeling implemented in GEODYN in support of
OSIRIS-REx operations, and show how both altimetry and imagery data can be used
as either undifferenced (landmark, direct altimetry) or differenced (image
crossover, altimetry crossover) measurements. We find that these two different
types of data contribute differently to the recovery of instrument pointing or
planetary orientation. When upweighted, the absolute measurements help reduce
the geolocation errors, despite poorer astrometric (inertial) performance. We
find that with no wobble present, all the geolocation requirements are met.
While the presence of a large wobble is detrimental, the recovery is still
reliable thanks to the combined use of altimetry and imagery data.
[2]
oai:arXiv.org:1507.08182 [pdf] - 1483212
The UWISH2 extended H2 source catalogue
Froebrich, D.;
Makin, S. V.;
Davis, C. J.;
Gledhill, T. M.;
Kim, Y.;
Koo, B. -C.;
Rowles, J.;
Eislöffel, J.;
Nicholas, J.;
Lee, J. J.;
Williamson, J.;
Buckner, A. S. M.
Submitted: 2015-07-27, last modified: 2015-08-11
We present the extended source catalogue for the UKIRT Widefield Infrared
Survey for H2 (UWISH2). The survey is unbiased along the inner Galactic Plane
from l \approx 357deg to l \approx 65deg and |b| < 1.5deg and covers 209 square
degrees. A further 42.0 and 35.5 square degrees of high dust column density
regions have been targeted in Cygnus and Auriga. We have identified 33200
individual extended H2 features. They have been classified to be associated
with about 700 groups of jets and outflows, 284 individual (candidate)
Planetary Nebulae, 30 Supernova Remnants and about 1300 Photo-Dissociation
Regions. We find a clear decline of star formation activity (traced by H2
emission from jets and photo-dissociation regions) with increasing distance
from the Galactic Centre. About 60% of the detected candidate Planetary Nebulae
have no known counterpart and 25% of all Supernova Remnants have detectable H2
emission associated with them.
[3]
oai:arXiv.org:astro-ph/0702631 [pdf] - 89685
New periodic variable stars coincident with ROSAT sources discovered
using SuperWASP
Norton, A. J.;
Wheatley, P. J.;
West, R. G.;
Haswell, C. A.;
Street, R. A.;
Cameron, A. Collier;
Christian, D. J.;
Enoch, B.;
Gallaway, M.;
Hellier, C.;
Horne, K.;
Irwin, J.;
Kane, S. R.;
Lister, T. A.;
Nicholas, J. P.;
Parley, N.;
Pollacco, D.;
Ryans, R.;
Skillen, I.;
Wilson, D. M.
Submitted: 2007-02-23
We present optical lightcurves of 428 periodic variable stars coincident with
ROSAT X-ray sources, detected using the first run of the SuperWASP photometric
survey. Only 68 of these were previously recognised as periodic variables. A
further 30 of these objects are previously known pre-main sequence stars, for
which we detect a modulation period for the first time. Amongst the newly
identified periodic variables, many appear to be close eclipsing binaries,
their X-ray emission is presumably the result of RS CVn type behaviour. Others
are probably BY Dra stars, pre-main sequence stars and other rapid rotators
displaying enhanced coronal activity. A number of previously catalogued
pulsating variables (RR Lyr stars and Cepheids) coincident with X-ray sources
are also seen, but we show that these are likely to be misclassifications. We
identify four objects which are probable low mass eclipsing binary stars, based
on their very red colour and light curve morphology.
[4]
oai:arXiv.org:astro-ph/9609186 [pdf] - 95506
Millimetric Ground-based Observations of Cosmic Microwave Background
Anisotropy
Submitted: 1996-09-26, last modified: 1996-12-04
First results of a Cosmic Microwave Background (CMB) anisotropy experiment
conducted at the Observatorio del Teide (Tenerife, Spain) are presented. The
instrument is a four channel (3.1, 2.1, 1.3 and 1.1 mm) $^3$He bolometer system
coupled to a 45 cm diameter telescope. The resultant configuration is sensitive
to structures on angular scales ~ 1-2 degrees. We use the channels at the two
highest frequencies for monitoring the atmosphere, and apply a simple method to
subtract this contribution in channels 1 (3.1 mm) and 2 (2.1 mm). The most
intense structure at these two frequencies is the Galactic crossing with peak
amplitudes of ~ 350 micro-K. These crossings have been clearly detected with
the amplitude and shape predicted. This demonstrates that our multifrequency
observations allow an effective assessment and subtraction of the atmospheric
contribution. In the section of data at high Galactic latitude we obtain
sensitivities ~ 40 micro-K per beam. The statistical analyses show the presence
of common signals between channels 1 and 2. Assuming a simple Gaussian
auto-correlation model with a scale of coherence $\theta_c=1.32$ degrees for
the signal, a likelihood analysis of this section of data reveals the presence
of fluctuations with intrinsic amplitude $C_{0}^{1/2} = 76^{+43}_{-32}$ micro
-K (68 % CL including a ~ 20% calibration uncertainty). Since residual
atmospheric noise might still contaminate our results, we also give our result
as an upper limit of 118 micro-K at 95% c.l.