Normalized to: Ng, M.
[1]
oai:arXiv.org:1904.08564 [pdf] - 2007903
Kinematics of the OVI Circumgalactic Medium: Halo Mass Dependence and
Outflow Signatures
Submitted: 2019-04-17, last modified: 2019-09-30
We probe the high-ionization circumgalactic medium by examining absorber
kinematics, absorber-galaxy kinematics, and average absorption profiles of 31
OVI absorbers from the "Multiphase Galaxy Halos" Survey as a function of halo
mass, redshift, inclination, and azimuthal angle. The galaxies are isolated at
$0.12<z_{\rm gal}<0.66$ and are probed by a background quasar within $D\approx
200$ kpc. Each absorber-galaxy pair has Hubble Space Telescope images and COS
quasar spectra, and most galaxy redshifts have been accurately measured from
Keck/ESI spectra. Using the pixel-velocity two-point correlation function
(TPCF) method, we find that OVI absorber kinematics have a strong halo mass
dependence. Absorbers hosted by $\sim L^{\ast}$ galaxies have the largest
velocity dispersions, which we interpret to be that the halo virial temperature
closely matches the temperature at which the collisionally ionized OVI fraction
peaks. Lower mass galaxies and group environments have smaller velocity
dispersions. Total column densities follow the same behavior, consistent with
theoretical findings. After normalizing out the observed mass dependence, we
studied absorber-galaxy kinematics with a modified TPCF and found
non-virialized motions due to outflowing gas. Edge-on minor axis gas has large
optical depths concentrated near the galaxy systemic velocity as expected for
bipolar outflows, while face-on minor axis gas has a smoothly decreasing
optical depth distribution out to large normalized absorber-galaxy velocities,
suggestive of decelerating outflowing gas. Accreting gas signatures are not
observed due to "kinematic blurring" in which multiple line-of-sight structures
are observed. These results indicate that galaxy mass dominates OVI properties
over baryon cycle processes.
[2]
oai:arXiv.org:1801.03730 [pdf] - 1616675
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to
look at the polarized Cosmic Microwave Background
Mennella, A.;
Ade, P. A. R.;
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Burke, D. P.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Columbro, F.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Leo, M.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Incardona, F.;
Kaplan, J.;
Korotkov, A.;
Krachmalnicoff, N.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Mele, L.;
Melhuish, S.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Préle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Torchinsky, S.;
Tristram, M.;
Tucker, C.;
Tucker, G.;
Viganò, D.;
Vittorio, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2018-01-11
In this paper we describe QUBIC, an experiment that takes up the challenge
posed by the detection of primordial gravitational waves with a novel approach,
that combines the sensitivity of state-of-the art bolometric detectors with the
systematic effects control typical of interferometers. The so-called
"self-calibration" is a technique deeply rooted in the interferometric nature
of the instrument and allows us to clean the measured data from instrumental
effects. The first module of QUBIC is a dual band instrument (150 GHz and 220
GHz) that will be deployed in Argentina during the Fall 2018.
[3]
oai:arXiv.org:1710.02154 [pdf] - 1593680
Binary Population and Spectral Synthesis Version 2.1: construction,
observational verification and new results
Submitted: 2017-10-05
The Binary Population and Spectral Synthesis (BPASS) suite of binary stellar
evolution models and synthetic stellar populations provides a framework for the
physically motivated analysis of both the integrated light from distant stellar
populations and the detailed properties of those nearby. We present a new
version 2.1 data release of these models, detailing the methodology by which
BPASS incorporates binary mass transfer and its effect on stellar evolution
pathways, as well as the construction of simple stellar populations. We
demonstrate key tests of the latest BPASS model suite demonstrating its ability
to reproduce the colours and derived properties of resolved stellar
populations, including well- constrained eclipsing binaries. We consider
observational constraints on the ratio of massive star types and the
distribution of stellar remnant masses. We describe the identification of
supernova progenitors in our models, and demonstrate a good agreement to the
properties of observed progenitors. We also test our models against photometric
and spectroscopic observations of unresolved stellar populations, both in the
local and distant Universe, finding that binary models provide a
self-consistent explanation for observed galaxy properties across a broad
redshift range. Finally, we carefully describe the limitations of our models,
and areas where we expect to see significant improvement in future versions.
[4]
oai:arXiv.org:1609.04372 [pdf] - 1576378
QUBIC Technical Design Report
Aumont, J.;
Banfi, S.;
Battaglia, P.;
Battistelli, E. S.;
Baù, A.;
Bélier, B.;
Bennett, D.;
Bergé, L.;
Bernard, J. Ph.;
Bersanelli, M.;
Bigot-Sazy, M. A.;
Bleurvacq, N.;
Bordier, G.;
Brossard, J.;
Bunn, E. F.;
Buzi, D.;
Buzzelli, A.;
Cammilleri, D.;
Cavaliere, F.;
Chanial, P.;
Chapron, C.;
Coppi, G.;
Coppolecchia, A.;
Couchot, F.;
D'Agostino, R.;
D'Alessandro, G.;
de Bernardis, P.;
De Gasperis, G.;
De Petris, M.;
Decourcelle, T.;
Del Torto, F.;
Dumoulin, L.;
Etchegoyen, A.;
Franceschet, C.;
Garcia, B.;
Gault, A.;
Gayer, D.;
Gervasi, M.;
Ghribi, A.;
Giard, M.;
Giraud-Héraud, Y.;
Gradziel, M.;
Grandsire, L.;
Hamilton, J. Ch.;
Harari, D.;
Haynes, V.;
Henrot-Versillé, S.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lamagna, L.;
Lande, J.;
Loucatos, S.;
Lowitz, A.;
Lukovic, V.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
May, A.;
McCulloch, M.;
Medina, M. C.;
Melhuish, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Néel, D.;
Ng, M. W.;
O'Sullivan, C.;
Paiella, A.;
Pajot, F.;
Passerini, A.;
Pelosi, A.;
Perbost, C.;
Perdereau, O.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Puddu, R.;
Rambaud, D.;
Rigaut, O.;
Romero, G. E.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
Stolpovskiy, M.;
Suarez, F.;
Tartari, A.;
Timbie, P.;
Tristram, M.;
Tucker, G.;
Viganò, D.;
Vittori, N.;
Voisin, F.;
Watson, B.;
Zannoni, M.;
Zullo, A.
Submitted: 2016-09-14, last modified: 2017-05-11
QUBIC is an instrument aiming at measuring the B mode polarisation
anisotropies at medium scales angular scales (30-200 multipoles). The search
for the primordial CMB B-mode polarization signal is challenging, because of
many difficulties: smallness of the expected signal, instrumental systematics
that could possibly induce polarization leakage from the large E signal into B,
brighter than anticipated polarized foregrounds (dust) reducing to zero the
initial hope of finding sky regions clean enough to have a direct primordial
B-modes observation. The QUBIC instrument is designed to address all aspects of
this challenge with a novel kind of instrument, a Bolometric Interferometer,
combining the background-limited sensitivity of Transition-Edge-Sensors and the
control of systematics allowed by the observation of interference fringe
patterns, while operating at two frequencies to disentangle polarized
foregrounds from primordial B mode polarization. Its characteristics are
described in details in this Technological Design Report.
[5]
oai:arXiv.org:1610.00582 [pdf] - 1490064
Multi-Octave Metamaterial Reflective Half-Wave Plate for Millimetre and
Sub-Millimetre wave Applications
Pisano, Giampaolo;
Maffei, Bruno;
Ade, Peter A. R.;
de Bernardis, Paolo;
De Maagt, Peter;
Ellison, Brian;
Henry, Manju;
Ng, Ming Wah;
Schortt, Brian;
Tucker, Carole
Submitted: 2016-10-03
The quasi-optical modulation of linear polarization at millimeter and
sub-millimeter wavelengths can be achieved by using rotating half wave plates
(HWPs) in front of polarization sensitive detectors. Large operational
bandwidths are required when the same device is meant to work simultaneously
across different frequency bands. Previous realizations of half wave plates,
ranging from birefringent multi-plate to mesh-based devices, have achieved
bandwidths of the order of 100%. Here we present the design and the
experimental characterization of a reflective HWP able to work across
bandwidths of the order of 150%. The working principle of the novel device is
completely different from any previous realization and it is based on the
different phase-shift experienced by two orthogonal polarizations respectively
reflecting off an electric conductor and off an artificial magnetic conductor.
[6]
oai:arXiv.org:1409.8516 [pdf] - 873983
Development of large radii half-wave plates for CMB satellite missions
Pisano, G.;
Maffei, B.;
Ng, M. W.;
Haynes, V.;
Brown, M.;
Noviello, F.;
de Bernardis, P.;
Masi, S.;
Piacentini, F.;
Pagano, L.;
Salatino, M.;
Ellison, B.;
Henry, M.;
de Maagt, P.;
Shortt, B.
Submitted: 2014-09-30
The successful European Space Agency (ESA) Planck mission has mapped the
Cosmic Microwave Background (CMB) temperature anisotropy with unprecedented
accuracy. However, Planck was not designed to detect the polarised components
of the CMB with comparable precision. The BICEP2 collaboration has recently
reported the first detection of the B-mode polarisation. ESA is funding the
development of critical enabling technologies associated with B-mode
polarisation detection, one of these being large diameter half-wave plates. We
compare different polarisation modulators and discuss their respective
trade-offs in terms of manufacturing, RF performance and thermo-mechanical
properties. We then select the most appropriate solution for future satellite
missions, optimized for the detection of B-modes.
[7]
oai:arXiv.org:1402.5448 [pdf] - 917192
W-Band Pancharatnam Half Wave Plate Based on Negative Refractive Index
Metamaterials
Submitted: 2014-02-21
Electromagnetic metamaterials, made from arrangements of subwavelength sized
structures, can be used to manipulate radiation. Designing metamaterials that
have a positive refractive index along one axis and a negative refractive index
along the orthogonal axis can result in birefringences, $\Delta n>1$. The
effect can be used to create wave plates with subwavelength thicknesses.
Previous attempts at making wave plates in this way have resulted in very
narrow usable bandwidths. In this paper, we use the Pancharatnam method to
increase the usable bandwidth. A combination of Finite Element Method and
Transmission Line models were used to optimise the final design. Experimental
results are compared to the modelled data.
[8]
oai:arXiv.org:1401.3798 [pdf] - 917191
Dog Bone Triplet Metamaterial Wave Plate
Submitted: 2014-01-15
Metamaterials are artificially made sub-wavelength structures arranged in
periodic arrays. They can be designed to interact with electromagnetic
radiation in many different and interesting ways such as allowing radiation to
experience a negative refractive index (NRI). We have used this technique to
design and build a quasi-optical Half Wave Plate (HWP) that exhibits a large
birefringence by virtue of having a positive refractive index in one axis and a
NRI in the other. Previous implementations of such NRI-HWP have been narrow
band ($\sim$1-3%) due to the inherent reliance on needing a resonance to create
the NRI region. We manufacture a W-band prototype of a novel HWP that uses the
Pancharatnam method to extend the bandwidth (up to more than twice) of a usual
NRI-HWP. Our simulated and experimentally obtained results despite their
differences show that a broadening of a flat region of the phase difference is
possible even with the initially steep gradient for a single plate.
[9]
oai:arXiv.org:1307.5701 [pdf] - 1172881
Latest Progress on the QUBIC Instrument
Ghribi, A.;
Aumont, J.;
Battistelli, E. S.;
Bau, A.;
Bergé, L.;
Bernard, J-Ph.;
Bersanelli, M.;
Bigot-Sazy, M-A.;
Bordier, G.;
Bunn, E. T.;
Cavaliere, F.;
Chanial, P.;
Coppolecchia, A.;
Decourcelle, T.;
De Bernardis, P.;
De Petris, M.;
Drilien, A-A.;
Dumoulin, L.;
Falvella, M. C.;
Gault, A.;
Gervasi, M.;
Giard, M.;
Gradziel, M.;
Grandsire, L.;
Gayer, D.;
Hamilton, J-Ch.;
Haynes, V.;
Giraud-Héraud, Y.;
Holtzer, N.;
Kaplan, J.;
Korotkov, A.;
Lande, J.;
Lowitz, A.;
Maffei, B.;
Marnieros, S.;
Martino, J.;
Masi, S.;
Mennella, A.;
Montier, L.;
Murphy, A.;
Ng, M. W.;
Olivieri, E.;
Pajot, F.;
Passerini, A.;
Piacentini, F.;
Piat, M.;
Piccirillo, L.;
Pisano, G.;
Prêle, D.;
Rambaud, D.;
Rigaut, O.;
Rosset, C.;
Salatino, M.;
Schillaci, A.;
Scully, S.;
O'Sullivan, C.;
Tartari, A.;
Timbie, P.;
Tucker, G.;
Vibert, L.;
Voisin, F.;
Watson, B.;
Zannoni, M.
Submitted: 2013-07-22, last modified: 2013-11-12
QUBIC is a unique instrument that crosses the barriers between classical
imaging architectures and interferometry taking advantage from both for high
sensitivity and systematics mitigation. The scientific target is the detection
of the primordial gravitational waves imprint on the Cosmic Microwave
Background which are the proof of inflation, holy grail of modern cosmology. In
this paper, we show the latest advances in the development of the architecture
and the sub-systems of the first module of this instrument to be deployed in
Dome Charlie Concordia base - Antarctica in 2015.
[10]
oai:arXiv.org:1206.2284 [pdf] - 800097
A Translational Polarization Rotator
Submitted: 2012-06-11, last modified: 2012-08-10
We explore a free-space polarization modulator in which a variable phase
introduction between right- and left-handed circular polarization components is
used to rotate the linear polarization of the outgoing beam relative to that of
the incoming beam. In this device, the polarization states are separated by a
circular polarizer that consists of a quarter-wave plate in combination with a
wire grid. A movable mirror is positioned behind and parallel to the circular
polarizer. As the polarizer-mirror distance is separated, an incident linear
polarization will be rotated through an angle that is proportional to the
introduced phase delay. We demonstrate a prototype device that modulates Stokes
Q and U over a 20% bandwidth, from 77 to 94 GHz.
[11]
oai:arXiv.org:1208.0282 [pdf] - 1150439
SWIPE: a bolometric polarimeter for the Large-Scale Polarization
Explorer
de Bernardis, P.;
Aiola, S.;
Amico, G.;
Battistelli, E.;
Coppolecchia, A.;
Cruciani, A.;
Addabbo, A. D';
Alessandro, G. D';
De Gregori, S.;
De Petris, M.;
Goldie, D.;
Gualtieri, R.;
Haynes, V.;
Lamagna, L.;
Maffei, B.;
Masi, S.;
Nati, F.;
Ng, M. Wah;
Pagano, L.;
Piacentini, F.;
Piccirillo, L.;
Pisano, G.;
Romeo, G.;
Salatino, M.;
Schillaci, A.;
Tommasi, E.;
Withington, S.
Submitted: 2012-08-01
The balloon-borne LSPE mission is optimized to measure the linear
polarization of the Cosmic Microwave Background at large angular scales. The
Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed
of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components
and filters cryogenically cooled below 4K to reduce the background on the
detectors. Polarimetry is achieved by means of large rotating half-wave plates
and wire-grid polarizers in front of the arrays. The polarization modulator is
the first component of the optical chain, reducing significantly the effect of
instrumental polarization. In SWIPE we trade angular resolution for
sensitivity. The diameter of the entrance pupil of the refractive telescope is
45 cm, while the field optics is optimized to collect tens of modes for each
detector, thus boosting the absorbed power. This approach results in a FWHM
resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The
expected performance of the three channels is limited by photon noise,
resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days
survey covering 25% of the sky.