[1]
oai:arXiv.org:1106.1090 [pdf] - 1077095
Reciprocity Failure in HgCdTe Detectors: Measurements and Mitigation
Submitted: 2011-06-06
A detailed study of reciprocity failure in four 1.7 micron cutoff HgCdTe
near-infrared detectors is presented. The sensitivity to reciprocity failure is
approximately 0.1%\decade over up to five orders of magnitude in illumination
intensity. The four detectors, which represent three successive production runs
with modified growth recipes, show large differences in amount and spatial
structure of reciprocity failure. Reciprocity failure could be reduced to
negligible levels by cooling the detectors to about 110 K. No wavelength
dependence was observed. The observed spatial structure appears to be weakly
correlated with image persistence.
[2]
oai:arXiv.org:1012.2411 [pdf] - 1042503
Measurement of Reciprocity Failure in Near Infrared Detectors
Submitted: 2010-12-10
Flux dependent non-linearity (reciprocity failure) in HgCdTe near infrared
detectors can severely impact an instrument's performance, in particular with
respect to precision photometric measurements. The cause of this effect is
presently not understood. To investigate reciprocity failure, a dedicated test
system was built. For flux levels between 1 and 50,000 photons/s, a sensitivity
to reciprocity failure of approximately 0.1%/decade was achieved. A wavelength
independent non-linearity due to reciprocity failure of about 0.35%/decade was
measured in a 1.7 micron HgCdTe detector.
[3]
oai:arXiv.org:1008.3369 [pdf] - 1034382
Investigating reciprocity failure in 1.7-micron cut-off HgCdTe detectors
Submitted: 2010-08-19
Flux dependent non-linearity (reciprocity failure) in HgCdTe NIR detectors
with 1.7 micron cut-off was investigated. A dedicated test station was designed
and built to measure reciprocity failure over the full dynamic range of near
infrared detectors. For flux levels between 1 and 100,000 photons/sec a
limiting sensitivity to reciprocity failure of 0.3%/decade was achieved. First
measurements on several engineering grade 1.7 micron cut-off HgCdTe detectors
show a wide range of reciprocity failure, from less than 0.5%/decade to about
10%/decade. For at least two of the tested detectors, significant spatial
variation in the effect was observed. No indication for wavelength dependency
was found. The origin of reciprocity failure is currently not well understood.
In this paper we present details of our experimental set-up and show the
results of measurements for several detectors.