sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Nesti, R.

Normalized to: Nesti, R.

11 article(s) in total. 322 co-authors, from 1 to 8 common article(s). Median position in authors list is 12,0.

[1]  oai:arXiv.org:1912.10841  [pdf] - 2052103
Wideband 67-116 GHz receiver development for ALMA Band 2
Comments: 23 pages, accepted for publication in A&A on 20 Dec 2019. This version corrects the affiliations of 2 co-authors
Submitted: 2019-12-20, last modified: 2020-02-20
ALMA has been operating since 2011, but has not yet been populated with the full suite of intended frequency bands. In particular, ALMA Band 2 (67-90 GHz) is the final band in the original ALMA band definition to be approved for production. We aim to produce a wideband, tuneable, sideband-separating receiver with 28 GHz of instantaneous bandwidth per polarisation operating in the sky frequency range 67-116 GHz. Our design anticipates new ALMA requirements following the recommendations in the 2030 ALMA Development Roadmap. The cryogenic cartridge is designed to be compatible with the ALMA Band 2 cartridge slot, where the coldest components -- the feedhorns, orthomode transducers, and cryogenic low noise amplifiers -- operate at a temperature of 15 K. We use multiple simulation methods and tools to optimise our designs for both the passive optics and the active components. The cryogenic cartridge interfaces with a room temperature cartridge hosting the local oscillator (LO) and the downconverter module. This warm cartridge is largely based on GaAs semiconductor technology and is optimised to match the cryogenic receiver bandwidth with the required instantaneous LO tuning range. Our collaboration has designed, fabricated, and tested multiple technical solutions for each of the components, producing a state-of-the-art receiver covering the full ALMA Band 2 & 3 atmospheric window. The receiver is suitable for deployment on ALMA in the coming years, and is capable of dual-polarisation, sideband-separating observations in intermediate frequency bands spanning 4-18 GHz, for a total of 28 GHz on-sky bandwidth per polarisation channel. We conclude that the 67-116 GHz wideband implementation for ALMA Band 2 is now feasible, and this receiver is a compelling instrumental upgrade that will enhance observational capabilities and scientific reach.
[2]  oai:arXiv.org:1812.03575  [pdf] - 1795026
Wideband 67-116 GHz cryogenic receiver development for ALMA Band 2
Comments: 8 pages, proceedings from the 8th ESA Workshop on Millimetre-Wave Technology and Applications (https://atpi.eventsair.com/QuickEventWebsitePortal/millimetre-wave/mm-wave)
Submitted: 2018-12-09
The Atacama Large Millimeter/sub-millimeter Array (ALMA) is already revolutionising our understanding of the Universe. However, ALMA is not yet equipped with all of its originally planned receiver bands, which will allow it to observe over the full range of frequencies from 35-950 GHz accessible through the Earth's atmosphere. In particular Band 2 (67-90 GHz) has not yet been approved for construction. Recent technological developments in cryogenic monolithic microwave integrated circuit (MMIC) high electron mobility transistor (HEMT) amplifier and orthomode transducer (OMT) design provide an opportunity to extend the originally planned on-sky bandwidth, combining ALMA Bands 2 and 3 into one receiver cartridge covering 67-116 GHz. The IF band definition for the ALMA project took place two decades ago, when 8 GHz of on-sky bandwidth per polarisation channel was an ambitious goal. The new receiver design we present here allows the opportunity to expand ALMA's wideband capabilities, anticipating future upgrades across the entire observatory. Expanding ALMA's instantaneous bandwidth is a high priority, and provides a number of observational advantages, including lower noise in continuum observations, the ability to probe larger portions of an astronomical spectrum for, e.g., widely spaced molecular transitions, and the ability to scan efficiently in frequency space to perform surveys where the redshift or chemical complexity of the object is not known a priori. Wider IF bandwidth also reduces uncertainties in calibration and continuum subtraction that might otherwise compromise science objectives. Here we provide an overview of the component development and overall design for this wideband 67-116 GHz cryogenic receiver cartridge, designed to operate from the Band 2 receiver cartridge slot in the current ALMA front end receiver cryostat.
[3]  oai:arXiv.org:1610.08796  [pdf] - 1560184
Laboratory measurements of super-resolving Toraldo pupils for radio astronomical applications
Comments: Accepted for publication in "Experimental Astronomy" on March 20th, 2017
Submitted: 2016-10-27, last modified: 2017-04-07
The concept of super-resolution refers to various methods for improving the angular resolution of an optical imaging system beyond the classical diffraction limit. Although several techniques to narrow the central lobe of the illumination Point Spread Function have been developed in optical microscopy, most of these methods cannot be implemented on astronomical telescopes. A possible exception is represented by the variable transmittance filters, also known as "Toraldo Pupils" (TPs) since they were introduced for the first time by G. Toraldo di Francia in 1952. In the microwave range, the first successful laboratory test of TPs was performed in 2003. These first results suggested that TPs could represent a viable approach to achieve super-resolution in Radio Astronomy. We have therefore started a project devoted to a more exhaustive analysis of TPs and how they could be implemented on a radio telescope. In the present work we report on the results of extensive microwave measurements, using TPs with different geometrical shapes, which confirm the correctness of the first experiments in 2003. We have also extended the original investigation to carry out full-wave electromagnetic numerical simulations and also to perform planar scanning of the near-field and transform the results into the far-field.
[4]  oai:arXiv.org:1101.2038  [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Mennella, A.; Bersanelli, M.; Butler, R. C.; Curto, A.; Cuttaia, F.; Davis, R. J.; Dick, J.; Frailis, M.; Galeotta, S.; Gregorio, A.; Kurki-Suonio, H.; Lawrence, C. R.; Leach, S.; Leahy, J. P.; Lowe, S.; Maino, D.; Mandolesi, N.; Maris, M.; Martínez-González, E.; Meinhold, P. R.; Morgante, G.; Pearson, D.; Perrotta, F.; Polenta, G.; Poutanen, T.; Sandri, M.; Seiffert, M. D.; Suur-Uski, A. -S.; Tavagnacco, D.; Terenzi, L.; Tomasi, M.; Valiviita, J.; Villa, F.; Watson, R.; Wilkinson, A.; Zacchei, A.; Zonca, A.; Aja, B.; Artal, E.; Baccigalupi, C.; Banday, A. J.; Barreiro, R. B.; Bartlett, J. G.; Bartolo, N.; Battaglia, P.; Bennett, K.; Bonaldi, A.; Bonavera, L.; Borrill, J.; Bouchet, F. R.; Burigana, C.; Cabella, P.; Cappellini, B.; Chen, X.; Colombo, L.; Cruz, M.; Danese, L.; D'Arcangelo, O.; Davies, R. D.; de Gasperis, G.; de Rosa, A.; de Zotti, G.; Dickinson, C.; Diego, J. M.; Donzelli, S.; Efstathiou, G.; Enßlin, T. A.; Eriksen, H. K.; Falvella, M. C.; Finelli, F.; Foley, S.; Franceschet, C.; Franceschi, E.; Gaier, T. C.; Génova-Santos, R. T.; George, D.; Gómez, F.; González-Nuevo, J.; Górski, K. M.; Gruppuso, A.; Hansen, F. K.; Herranz, D.; Herreros, J. M.; Hoyland, R. J.; Hughes, N.; Jewell, J.; Jukkala, P.; Juvela, M.; Kangaslahti, P.; Keihänen, E.; Keskitalo, R.; Kilpia, V. -H.; Kisner, T. S.; Knoche, J.; Knox, L.; Laaninen, M.; Lähteenmäki, A.; Lamarre, J. -M.; Leonardi, R.; León-Tavares, J.; Leutenegger, P.; Lilje, P. B.; López-Caniego, M.; Lubin, P. M.; Malaspina, M.; Marinucci, D.; Massardi, M.; Matarrese, S.; Matthai, F.; Melchiorri, A.; Mendes, L.; Miccolis, M.; Migliaccio, M.; Mitra, S.; Moss, A.; Natoli, P.; Nesti, R.; Nørgaard-Nielsen, H. U.; Pagano, L.; Paladini, R.; Paoletti, D.; Partridge, B.; Pasian, F.; Pettorino, V.; Pietrobon, D.; Pospieszalski, M.; Prézeau, G.; Prina, M.; Procopio, P.; Puget, J. -L.; Quercellini, C.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Ricciardi, S.; Robbers, G.; Rocha, G.; Roddis, N.; Rubiño-Martín, J. A.; Savelainen, M.; Scott, D.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Tauber, J. A.; Tofani, G.; Toffolatti, L.; Tuovinen, J.; Türler, M.; Umana, G.; Valenziano, L.; Varis, J.; Vielva, P.; Vittorio, N.; Wade, L. A.; Watson, C.; White, S. D. M.; Winder, F.
Comments: Published version
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
[5]  oai:arXiv.org:1001.4633  [pdf] - 33153
Planck LFI flight model feed horns
Comments: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12004
Submitted: 2010-01-26
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns. They have been designed to optimize the LFI optical interfaces taking into account the tight mechanical requirements imposed by the Planck focal plane layout. All the eleven units have been successfully tested and integrated with the Ortho Mode transducers.
[6]  oai:arXiv.org:1001.3321  [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency Instrument
Bersanelli, M.; Mandolesi, N.; Butler, R. C.; Mennella, A.; Villa, F.; Aja, B.; Artal, E.; Artina, E.; Baccigalupi, C.; Balasini, M.; Baldan, G.; Banday, A.; Bastia, P.; Battaglia, P.; Bernardino, T.; Blackhurst, E.; Boschini, L.; Burigana, C.; Cafagna, G.; Cappellini, B.; Cavaliere, F.; Colombo, F.; Crone, G.; Cuttaia, F.; D'Arcangelo, O.; Danese, L.; Davies, R. D.; Davis, R. J.; De Angelis, L.; De Gasperis, G. C.; De La Fuente, L.; De Rosa, A.; De Zotti, G.; Falvella, M. C.; Ferrari, F.; Ferretti, R.; Figini, L.; Fogliani, S.; Franceschet, C.; Franceschi, E.; Gaier, T.; Garavaglia, S.; Gomez, F.; Gorski, K.; Gregorio, A.; Guzzi, P.; Herreros, J. M.; Hildebrandt, S. R.; Hoyland, R.; Hughes, N.; Janssen, M.; Jukkala, P.; Kettle, D.; Kilpia, V. H.; Laaninen, M.; Lapolla, P. M.; Lawrence, C. R.; Leahy, J. P.; Leonardi, R.; Leutenegger, P.; Levin, S.; Lilje, P. B.; Lowe, S. R.; Lubin, D. Lawson P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Mediavilla, A.; Meinhold, P.; Miccolis, M.; Morgante, G.; Natoli, P.; Nesti, R.; Pagan, L.; Paine, C.; Partridge, B.; Pascual, J. P.; Pasian, F.; Pearson, D.; Pecora, M.; Perrotta, F.; Platania, P.; Pospieszalski, M.; Poutanen, T.; Prina, M.; Rebolo, R.; Roddis, N.; Rubino-Martin, J. A.; Salmon, n M. J.; Sandri, M.; Seiffert, M.; Silvestri, R.; Simonetto, A.; Sjoman, P.; Smoot, G. F.; Sozzi, C.; Stringhetti, L.; Taddei, E.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Valenziano, L.; Varis, J.; Vittorio, N.; Wade, L. A.; Wilkinson, A.; Winder, F.; Zacchei, A.; Zonca, A.
Comments: 23 pages, 31 figures, accepted by Astronomy and Astrophysics, Planck LFI technical papers published by JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
[7]  oai:arXiv.org:1001.2657  [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.; Bersanelli, M.; Butler, R. C.; Artal, E.; Baccigalupi, C.; Balbi, A.; Banday, A. J.; Barreiro, R. B.; Bartelmann, M.; Bennett, K.; Bhandari, P.; Bonaldi, A.; Borrill, J.; Bremer, M.; Burigana, C.; Bowman, R. C.; Cabella, P.; Cantalupo, C.; Cappellini, B.; Courvoisier, T.; Crone, G.; Cuttaia, F.; Danese, L.; D'Arcangelo, O.; Davies, R. D.; Davis, R. J.; De Angelis, L.; de Gasperis, G.; De Rosa, A.; De Troia, G.; de Zotti, G.; Dick, J.; Dickinson, C.; Diego, J. M.; Donzelli, S.; Dörl, U.; Dupac, X.; Enßlin, T. A.; Eriksen, H. K.; Falvella, M. C.; Finelli, F.; Frailis, M.; Franceschi, E.; Gaier, T.; Galeotta, S.; Gasparo, F.; Giardino, G.; Gomez, F.; Gonzalez-Nuevo, J.; Górski, K. M.; Gregorio, A.; Gruppuso, A.; Hansen, F.; Hell, R.; Herranz, D.; Herreros, J. M.; Hildebrandt, S.; Hovest, W.; Hoyland, R.; Huffenberger, K.; Janssen, M.; Jaffe, T.; Keihänen, E.; Keskitalo, R.; Kisner, T.; Kurki-Suonio, H.; Lähteenmäki, A.; Lawrence, C. R.; Leach, S. M.; Leahy, J. P.; Leonardi, R.; Levin, S.; Lilje, P. B.; López-Caniego, M.; Lowe, S. R.; Lubin, P. M.; Maino, D.; Malaspina, M.; Maris, M.; Marti-Canales, J.; Martinez-Gonzalez, E.; Massardi, M.; Matarrese, S.; Matthai, F.; Meinhold, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Morgante, G.; Morigi, G.; Morisset, N.; Moss, A.; Nash, A.; Natoli, P.; Nesti, R.; Paine, C.; Partridge, B.; Pasian, F.; Passvogel, T.; Pearson, D.; Pérez-Cuevas, L.; Perrotta, F.; Polenta, G.; Popa, L. A.; Poutanen, T.; Prezeau, G.; Prina, M.; Rachen, J. P.; Rebolo, R.; Reinecke, M.; Ricciardi, S.; Riller, T.; Rocha, G.; Roddis, N.; Rohlfs, R.; Rubiño-Martin, J. A.; Salerno, E.; Sandri, M.; Scott, D.; Seiffert, M.; Silk, J.; Simonetto, A.; Smoot, G. F.; Sozzi, C.; Sternberg, J.; Stivoli, F.; Stringhetti, L.; Tauber, J.; Terenzi, L.; Tomasi, M.; Tuovinen, J.; Türler, M.; Valenziano, L.; Varis, J.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.; White, M.; White, S.; Wilkinson, A.; Zacchei, A.; Zonca, A.
Comments: 25 pages, 16 figures. In press on Astronomy and Astrophysics
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
[8]  oai:arXiv.org:0710.0790  [pdf] - 5638
Water maser variability over 20 years in a large sample of star-forming regions: the complete database
Comments: 11 pages, 9 figures, to be published in Astronomy and Astrophysics; all plots in appendix (not included) can be downloaded from http://www.arcetri.astro.it/~starform/water_maser_v2.html or http://www.ira.inaf.it/papers/masers/water_maser_v2.html
Submitted: 2007-10-03
Context. Water vapor emission at 22 GHz from masers associated with star-forming regions is highly variable. Aims. We present a database of up to 20 years of monitoring of a sample of 43 masers within star-forming regions. The sample covers a large range of luminosities of the associated IRAS source and is representative of the entire population of H2O masers of this type. The database forms a good starting point for any further study of H2O maser variability. Methods. The observations were obtained with the Medicina 32-m radiotelescope, at a rate of 4-5 observations per year. Results. To provide a database that can be easily accessed through the web, we give for each source: plots of the calibrated spectra, the velocity-time-flux density plot, the light curve of the integrated flux, the lower and upper envelopes of the maser emission, the mean spectrum, and the rate of the maser occurrence as a function of velocity. Figures for just one source are given in the text for representative purposes. Figures for all the sources are given in electronic form in the on-line appendix. A discussion of the main properties of the H2O variability in our sample will be presented in a forthcoming paper.
[9]  oai:arXiv.org:astro-ph/0307309  [pdf] - 58022
High Performances Corrugated Feed Horns for Space Applications at Millimetre Wavelengths
Comments: 16 pages, 7 figures, accepted for publication in Experimental Astronomy
Submitted: 2003-07-16
We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70 GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and by electro-formation at higher frequencies. The measured performances on side lobes and return loss meet the stringent Planck requirements over the large (20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape and side lobes levels of the dual profiled designs has been demonstrated.
[10]  oai:arXiv.org:astro-ph/0305152  [pdf] - 56625
Trade-off between angular resolution and straylight contamination in CMB anisotropy experiments. I. Pattern simulations
Comments: 23 pages, 19 figures (quality of the figures was degraded for size-related reasons). Submitted to A&A
Submitted: 2003-05-09
The study of Cosmic Microwave Background (CMB) anisotropies represents one of the most powerful Cosmological tools. After the great success of the two NASA's satellite missions COBE and WMAP, Planck represents the third generation of mm-wave instruments designed for space observations of CMB anisotropies within the new Cosmic Vision 2020 ESA Science Programme. The Planck survey will cover the whole sky with unprecedented sensitivity, angular resolution and frequency coverage, using two instruments that share the focal region of a 1.5 m off-axis dual reflector telescope: the Low Frequency Instrument (LFI) and the High Frequency Instrument (HFI). Within the LFI optical interfaces optimisation activity, two concurrent demands have to be satisfied: the best angular resolution (which impacts the ability to reconstruct the anisotropy power spectrum of the CMB anisotropies at high multipoles) and the lowest level of straylight contamination (that may be one of the most critical sources of systematic effects). We present the results of the optical simulations aimed to establish the trade-off between angular resolution and straylight rejection, carried out for the 100 GHz channel of Planck Low Frequency Instrument. Antenna pattern of different models of dual profiled corrugated conical feed horns have been simulated using advanced simulation techniques, considering the whole spacecraft geometry in order to obtain truthful sidelobe predictions. Optical computation accuracy necessary to provide strong straylight evaluation in reasonable computational time is shown and the inadequacy of a Gaussian feed model in realistic far pattern predictions is demonstrated. This paper is based on LFI activities.
[11]  oai:arXiv.org:astro-ph/0301020  [pdf] - 53991
The BaR-SPOrt Experiment
Comments: 12 pages, 10 figures, Astronomical Telescopes and Instrumentation (Polaimetry in Astronomy) Hawaii August 2002 SPIE Meeting
Submitted: 2003-01-02
BaR-SPOrt (Balloon-borne Radiometers for Sky Polarisation Observations) is an experiment to measure the linearly polarized emission of sky patches at 32 and 90 GHz with sub-degree angular resolution. It is equipped with high sensitivity correlation polarimeters for simultaneous detection of both the U and Q stokes parameters of the incident radiation. On-axis telescope is used to observe angular scales where the expected polarization of the Cosmic Microwave Background (CMBP) peaks. This project shares most of the know-how and sophisticated technology developed for the SPOrt experiment onboard the International Space Station. The payload is designed to flight onboard long duration stratospheric balloons both in the Northern and Southern hemispheres where low foreground emission sky patches are accessible. Due to the weakness of the expected CMBP signal (in the range of microK), much care has been spent to optimize the instrument design with respect to the systematics generation, observing time efficiency and long term stability. In this contribution we present the instrument design, and first tests on some components of the 32 GHz radiometer.