Normalized to: Nesti, R.
[1]
oai:arXiv.org:1912.10841 [pdf] - 2052103
Wideband 67-116 GHz receiver development for ALMA Band 2
Yagoubov, P.;
Mroczkowski, T.;
Belitsky, V.;
Cuadrado-Calle, D.;
Cuttaia, F.;
Fuller, G. A.;
Gallego, J. -D.;
Gonzalez, A.;
Kaneko, K.;
Mena, P.;
Molina, R.;
Nesti, R.;
Tapia, V.;
Villa, F.;
Beltran, M.;
Cavaliere, F.;
Ceru, J.;
Chesmore, G. E.;
Coughlin, K.;
De Breuck, C.;
Fredrixon, M.;
George, D.;
Gibson, H.;
Golec, J.;
Josaitis, A.;
Kemper, F.;
Kotiranta, M.;
Lapkin, I.;
Lopez-Fernandez, I.;
Marconi, G.;
Mariotti, S.;
McGenn, W.;
McMahon, J.;
Murk, A.;
Pezzotta, F.;
Phillips, N.;
Reyes, N.;
Ricciardi, S.;
Sandri, M.;
Strandberg, M.;
Terenzi, L.;
Testi, L.;
Thomas, B.;
Uzawa, Y.;
Vigano, D.;
Wadefalk, N.
Submitted: 2019-12-20, last modified: 2020-02-20
ALMA has been operating since 2011, but has not yet been populated with the
full suite of intended frequency bands. In particular, ALMA Band 2 (67-90 GHz)
is the final band in the original ALMA band definition to be approved for
production. We aim to produce a wideband, tuneable, sideband-separating
receiver with 28 GHz of instantaneous bandwidth per polarisation operating in
the sky frequency range 67-116 GHz. Our design anticipates new ALMA
requirements following the recommendations in the 2030 ALMA Development
Roadmap. The cryogenic cartridge is designed to be compatible with the ALMA
Band 2 cartridge slot, where the coldest components -- the feedhorns, orthomode
transducers, and cryogenic low noise amplifiers -- operate at a temperature of
15 K. We use multiple simulation methods and tools to optimise our designs for
both the passive optics and the active components. The cryogenic cartridge
interfaces with a room temperature cartridge hosting the local oscillator (LO)
and the downconverter module. This warm cartridge is largely based on GaAs
semiconductor technology and is optimised to match the cryogenic receiver
bandwidth with the required instantaneous LO tuning range. Our collaboration
has designed, fabricated, and tested multiple technical solutions for each of
the components, producing a state-of-the-art receiver covering the full ALMA
Band 2 & 3 atmospheric window. The receiver is suitable for deployment on ALMA
in the coming years, and is capable of dual-polarisation, sideband-separating
observations in intermediate frequency bands spanning 4-18 GHz, for a total of
28 GHz on-sky bandwidth per polarisation channel. We conclude that the 67-116
GHz wideband implementation for ALMA Band 2 is now feasible, and this receiver
is a compelling instrumental upgrade that will enhance observational
capabilities and scientific reach.
[2]
oai:arXiv.org:1812.03575 [pdf] - 1795026
Wideband 67-116 GHz cryogenic receiver development for ALMA Band 2
Yagoubov, P.;
Mroczkowski, T.;
Testi, L.;
De Breuck, C.;
Gonzalez, A.;
Kaneko, K.;
Uzawa, Y.;
Molina, R.;
Tapia, V.;
Reyes, N.;
Mena, P.;
Beltran, M.;
Nesti, R.;
Cuttaia, F.;
Ricciardi, S.;
Sandri, M.;
Terenzi, L.;
Villa, F.;
Murk, A.;
Kotiranta, M.;
McGenn, W.;
Cuadrado-Calle, D.;
Fuller, G. A.;
George, D.;
Gallego, J. -D.;
Lapkin, I.;
Fredrixon, M.;
Belitsky, V.
Submitted: 2018-12-09
The Atacama Large Millimeter/sub-millimeter Array (ALMA) is already
revolutionising our understanding of the Universe. However, ALMA is not yet
equipped with all of its originally planned receiver bands, which will allow it
to observe over the full range of frequencies from 35-950 GHz accessible
through the Earth's atmosphere. In particular Band 2 (67-90 GHz) has not yet
been approved for construction. Recent technological developments in cryogenic
monolithic microwave integrated circuit (MMIC) high electron mobility
transistor (HEMT) amplifier and orthomode transducer (OMT) design provide an
opportunity to extend the originally planned on-sky bandwidth, combining ALMA
Bands 2 and 3 into one receiver cartridge covering 67-116 GHz.
The IF band definition for the ALMA project took place two decades ago, when
8 GHz of on-sky bandwidth per polarisation channel was an ambitious goal. The
new receiver design we present here allows the opportunity to expand ALMA's
wideband capabilities, anticipating future upgrades across the entire
observatory. Expanding ALMA's instantaneous bandwidth is a high priority, and
provides a number of observational advantages, including lower noise in
continuum observations, the ability to probe larger portions of an astronomical
spectrum for, e.g., widely spaced molecular transitions, and the ability to
scan efficiently in frequency space to perform surveys where the redshift or
chemical complexity of the object is not known a priori. Wider IF bandwidth
also reduces uncertainties in calibration and continuum subtraction that might
otherwise compromise science objectives.
Here we provide an overview of the component development and overall design
for this wideband 67-116 GHz cryogenic receiver cartridge, designed to operate
from the Band 2 receiver cartridge slot in the current ALMA front end receiver
cryostat.
[3]
oai:arXiv.org:1610.08796 [pdf] - 1560184
Laboratory measurements of super-resolving Toraldo pupils for radio
astronomical applications
Olmi, Luca;
Bolli, Pietro;
Cresci, Luca;
D'Agostino, Francesco;
Migliozzi, Massimo;
Mugnai, Daniela;
Natale, Enzo;
Nesti, Renzo;
Panella, Dario;
Stefani, Lorenzo
Submitted: 2016-10-27, last modified: 2017-04-07
The concept of super-resolution refers to various methods for improving the
angular resolution of an optical imaging system beyond the classical
diffraction limit. Although several techniques to narrow the central lobe of
the illumination Point Spread Function have been developed in optical
microscopy, most of these methods cannot be implemented on astronomical
telescopes. A possible exception is represented by the variable transmittance
filters, also known as "Toraldo Pupils" (TPs) since they were introduced for
the first time by G. Toraldo di Francia in 1952. In the microwave range, the
first successful laboratory test of TPs was performed in 2003. These first
results suggested that TPs could represent a viable approach to achieve
super-resolution in Radio Astronomy. We have therefore started a project
devoted to a more exhaustive analysis of TPs and how they could be implemented
on a radio telescope. In the present work we report on the results of extensive
microwave measurements, using TPs with different geometrical shapes, which
confirm the correctness of the first experiments in 2003. We have also extended
the original investigation to carry out full-wave electromagnetic numerical
simulations and also to perform planar scanning of the near-field and transform
the results into the far-field.
[4]
oai:arXiv.org:1101.2038 [pdf] - 955981
Planck early results. III. First assessment of the Low Frequency
Instrument in-flight performance
Mennella, A.;
Bersanelli, M.;
Butler, R. C.;
Curto, A.;
Cuttaia, F.;
Davis, R. J.;
Dick, J.;
Frailis, M.;
Galeotta, S.;
Gregorio, A.;
Kurki-Suonio, H.;
Lawrence, C. R.;
Leach, S.;
Leahy, J. P.;
Lowe, S.;
Maino, D.;
Mandolesi, N.;
Maris, M.;
Martínez-González, E.;
Meinhold, P. R.;
Morgante, G.;
Pearson, D.;
Perrotta, F.;
Polenta, G.;
Poutanen, T.;
Sandri, M.;
Seiffert, M. D.;
Suur-Uski, A. -S.;
Tavagnacco, D.;
Terenzi, L.;
Tomasi, M.;
Valiviita, J.;
Villa, F.;
Watson, R.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.;
Aja, B.;
Artal, E.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Bartlett, J. G.;
Bartolo, N.;
Battaglia, P.;
Bennett, K.;
Bonaldi, A.;
Bonavera, L.;
Borrill, J.;
Bouchet, F. R.;
Burigana, C.;
Cabella, P.;
Cappellini, B.;
Chen, X.;
Colombo, L.;
Cruz, M.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
de Gasperis, G.;
de Rosa, A.;
de Zotti, G.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Foley, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T. C.;
Génova-Santos, R. T.;
George, D.;
Gómez, F.;
González-Nuevo, J.;
Górski, K. M.;
Gruppuso, A.;
Hansen, F. K.;
Herranz, D.;
Herreros, J. M.;
Hoyland, R. J.;
Hughes, N.;
Jewell, J.;
Jukkala, P.;
Juvela, M.;
Kangaslahti, P.;
Keihänen, E.;
Keskitalo, R.;
Kilpia, V. -H.;
Kisner, T. S.;
Knoche, J.;
Knox, L.;
Laaninen, M.;
Lähteenmäki, A.;
Lamarre, J. -M.;
Leonardi, R.;
León-Tavares, J.;
Leutenegger, P.;
Lilje, P. B.;
López-Caniego, M.;
Lubin, P. M.;
Malaspina, M.;
Marinucci, D.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Melchiorri, A.;
Mendes, L.;
Miccolis, M.;
Migliaccio, M.;
Mitra, S.;
Moss, A.;
Natoli, P.;
Nesti, R.;
Nørgaard-Nielsen, H. U.;
Pagano, L.;
Paladini, R.;
Paoletti, D.;
Partridge, B.;
Pasian, F.;
Pettorino, V.;
Pietrobon, D.;
Pospieszalski, M.;
Prézeau, G.;
Prina, M.;
Procopio, P.;
Puget, J. -L.;
Quercellini, C.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Robbers, G.;
Rocha, G.;
Roddis, N.;
Rubiño-Martín, J. A.;
Savelainen, M.;
Scott, D.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Tauber, J. A.;
Tofani, G.;
Toffolatti, L.;
Tuovinen, J.;
Türler, M.;
Umana, G.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Vittorio, N.;
Wade, L. A.;
Watson, C.;
White, S. D. M.;
Winder, F.
Submitted: 2011-01-11, last modified: 2011-12-19
The scientific performance of the Planck Low Frequency Instrument (LFI) after
one year of in-orbit operation is presented. We describe the main optical
parameters and discuss photometric calibration, white noise sensitivity, and
noise properties. A preliminary evaluation of the impact of the main systematic
effects is presented. For each of the performance parameters, we outline the
methods used to obtain them from the flight data and provide a comparison with
pre-launch ground assessments, which are essentially confirmed in flight.
[5]
oai:arXiv.org:1001.4633 [pdf] - 33153
Planck LFI flight model feed horns
Villa, F.;
D'Arcangelo, O.;
Pecora, M.;
Figini, L.;
Nesti, R.;
Simonetto, A.;
Sozzi, C.;
Sandri, M.;
Battaglia, P.;
Guzzi, P.;
Bersanelli, M.;
Butler, R. C.;
Mandolesi, N.
Submitted: 2010-01-26
this paper is part of the Prelaunch status LFI papers published on JINST:
http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency
Instrument is optically interfaced with the ESA Planck telescope through 11
corrugated feed horns each connected to the Radiometer Chain Assembly (RCA).
This paper describes the design, the manufacturing and the testing of the
flight model feed horns. They have been designed to optimize the LFI optical
interfaces taking into account the tight mechanical requirements imposed by the
Planck focal plane layout. All the eleven units have been successfully tested
and integrated with the Ortho Mode transducers.
[6]
oai:arXiv.org:1001.3321 [pdf] - 1024699
Planck pre-launch status: Design and description of the Low Frequency
Instrument
Bersanelli, M.;
Mandolesi, N.;
Butler, R. C.;
Mennella, A.;
Villa, F.;
Aja, B.;
Artal, E.;
Artina, E.;
Baccigalupi, C.;
Balasini, M.;
Baldan, G.;
Banday, A.;
Bastia, P.;
Battaglia, P.;
Bernardino, T.;
Blackhurst, E.;
Boschini, L.;
Burigana, C.;
Cafagna, G.;
Cappellini, B.;
Cavaliere, F.;
Colombo, F.;
Crone, G.;
Cuttaia, F.;
D'Arcangelo, O.;
Danese, L.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
De Gasperis, G. C.;
De La Fuente, L.;
De Rosa, A.;
De Zotti, G.;
Falvella, M. C.;
Ferrari, F.;
Ferretti, R.;
Figini, L.;
Fogliani, S.;
Franceschet, C.;
Franceschi, E.;
Gaier, T.;
Garavaglia, S.;
Gomez, F.;
Gorski, K.;
Gregorio, A.;
Guzzi, P.;
Herreros, J. M.;
Hildebrandt, S. R.;
Hoyland, R.;
Hughes, N.;
Janssen, M.;
Jukkala, P.;
Kettle, D.;
Kilpia, V. H.;
Laaninen, M.;
Lapolla, P. M.;
Lawrence, C. R.;
Leahy, J. P.;
Leonardi, R.;
Leutenegger, P.;
Levin, S.;
Lilje, P. B.;
Lowe, S. R.;
Lubin, D. Lawson P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Mediavilla, A.;
Meinhold, P.;
Miccolis, M.;
Morgante, G.;
Natoli, P.;
Nesti, R.;
Pagan, L.;
Paine, C.;
Partridge, B.;
Pascual, J. P.;
Pasian, F.;
Pearson, D.;
Pecora, M.;
Perrotta, F.;
Platania, P.;
Pospieszalski, M.;
Poutanen, T.;
Prina, M.;
Rebolo, R.;
Roddis, N.;
Rubino-Martin, J. A.;
Salmon, n M. J.;
Sandri, M.;
Seiffert, M.;
Silvestri, R.;
Simonetto, A.;
Sjoman, P.;
Smoot, G. F.;
Sozzi, C.;
Stringhetti, L.;
Taddei, E.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Valenziano, L.;
Varis, J.;
Vittorio, N.;
Wade, L. A.;
Wilkinson, A.;
Winder, F.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-19
In this paper we present the Low Frequency Instrument (LFI), designed and
developed as part of the Planck space mission, the ESA program dedicated to
precision imaging of the cosmic microwave background (CMB). Planck-LFI will
observe the full sky in intensity and polarisation in three frequency bands
centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be
covered by the HFI instrument. The LFI is an array of microwave radiometers
based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers
implemented in a differential system using blackbody loads as reference
signals. The front-end is cooled to 20K for optimal sensitivity and the
reference loads are cooled to 4K to minimise low frequency noise. We provide an
overview of the LFI, discuss the leading scientific requirements and describe
the design solutions adopted for the various hardware subsystems. The main
drivers of the radiometric, optical and thermal design are discussed, including
the stringent requirements on sensitivity, stability, and rejection of
systematic effects. Further details on the key instrument units and the results
of ground calibration are provided in a set of companion papers.
[7]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[8]
oai:arXiv.org:0710.0790 [pdf] - 5638
Water maser variability over 20 years in a large sample of star-forming
regions: the complete database
Felli, M.;
Brand, J.;
Cesaroni, R.;
Codella, C.;
Comoretto, G.;
Di Franco, S.;
Massi, F.;
Moscadelli, L.;
Nesti, R.;
Olmi, L.;
Palagi, F.;
Panella, D.;
Valdettaro, R.
Submitted: 2007-10-03
Context. Water vapor emission at 22 GHz from masers associated with
star-forming regions is highly variable. Aims. We present a database of up to
20 years of monitoring of a sample of 43 masers within star-forming regions.
The sample covers a large range of luminosities of the associated IRAS source
and is representative of the entire population of H2O masers of this type. The
database forms a good starting point for any further study of H2O maser
variability. Methods. The observations were obtained with the Medicina 32-m
radiotelescope, at a rate of 4-5 observations per year. Results. To provide a
database that can be easily accessed through the web, we give for each source:
plots of the calibrated spectra, the velocity-time-flux density plot, the light
curve of the integrated flux, the lower and upper envelopes of the maser
emission, the mean spectrum, and the rate of the maser occurrence as a function
of velocity. Figures for just one source are given in the text for
representative purposes. Figures for all the sources are given in electronic
form in the on-line appendix. A discussion of the main properties of the H2O
variability in our sample will be presented in a forthcoming paper.
[9]
oai:arXiv.org:astro-ph/0307309 [pdf] - 58022
High Performances Corrugated Feed Horns for Space Applications at
Millimetre Wavelengths
Villa, F.;
Sandri, M.;
Mandolesi, N.;
Nesti, R.;
Bersanelli, M.;
Simonetto, A.;
Sozzi, C.;
D'Arcangelo, O.;
Muzzini, V.;
Mennella, A.;
Guzzi, P.;
Radaelli, P.;
Fusi, R.;
Alippi, E.
Submitted: 2003-07-16
We report on the design, fabrication and testing of a set of high performance
corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced
prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission.
The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70
GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and
by electro-formation at higher frequencies. The measured performances on side
lobes and return loss meet the stringent Planck requirements over the large
(20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape
and side lobes levels of the dual profiled designs has been demonstrated.
[10]
oai:arXiv.org:astro-ph/0305152 [pdf] - 56625
Trade-off between angular resolution and straylight contamination in CMB
anisotropy experiments. I. Pattern simulations
Submitted: 2003-05-09
The study of Cosmic Microwave Background (CMB) anisotropies represents one of
the most powerful Cosmological tools. After the great success of the two NASA's
satellite missions COBE and WMAP, Planck represents the third generation of
mm-wave instruments designed for space observations of CMB anisotropies within
the new Cosmic Vision 2020 ESA Science Programme. The Planck survey will cover
the whole sky with unprecedented sensitivity, angular resolution and frequency
coverage, using two instruments that share the focal region of a 1.5 m off-axis
dual reflector telescope: the Low Frequency Instrument (LFI) and the High
Frequency Instrument (HFI). Within the LFI optical interfaces optimisation
activity, two concurrent demands have to be satisfied: the best angular
resolution (which impacts the ability to reconstruct the anisotropy power
spectrum of the CMB anisotropies at high multipoles) and the lowest level of
straylight contamination (that may be one of the most critical sources of
systematic effects). We present the results of the optical simulations aimed to
establish the trade-off between angular resolution and straylight rejection,
carried out for the 100 GHz channel of Planck Low Frequency Instrument. Antenna
pattern of different models of dual profiled corrugated conical feed horns have
been simulated using advanced simulation techniques, considering the whole
spacecraft geometry in order to obtain truthful sidelobe predictions. Optical
computation accuracy necessary to provide strong straylight evaluation in
reasonable computational time is shown and the inadequacy of a Gaussian feed
model in realistic far pattern predictions is demonstrated. This paper is based
on LFI activities.
[11]
oai:arXiv.org:astro-ph/0301020 [pdf] - 53991
The BaR-SPOrt Experiment
Zannoni, M.;
Cortiglioni, S.;
Bernardi, G.;
Carretti, E.;
Cecchini, S.;
Macculi, C.;
Morelli, E.;
Sbarra, C.;
Ventura, G.;
Nicastro, L.;
Monari, J.;
Poloni, M.;
Poppi, S.;
Natale, V.;
Baralis, M.;
Peverini, O.;
Tascone, R.;
Virone, G.;
Boscaleri, A.;
Pascale, E.;
Boella, G.;
Bonometto, S.;
Gervasi, M.;
Sironi, G.;
Tucci, M.;
Nesti, R.;
Fabbri, R.;
de Bernardis, P.;
De Petris, M.;
Masi, S.;
Sazhin, M. V.;
Vinyajkin, E. N.
Submitted: 2003-01-02
BaR-SPOrt (Balloon-borne Radiometers for Sky Polarisation Observations) is an
experiment to measure the linearly polarized emission of sky patches at 32 and
90 GHz with sub-degree angular resolution. It is equipped with high sensitivity
correlation polarimeters for simultaneous detection of both the U and Q stokes
parameters of the incident radiation. On-axis telescope is used to observe
angular scales where the expected polarization of the Cosmic Microwave
Background (CMBP) peaks. This project shares most of the know-how and
sophisticated technology developed for the SPOrt experiment onboard the
International Space Station. The payload is designed to flight onboard long
duration stratospheric balloons both in the Northern and Southern hemispheres
where low foreground emission sky patches are accessible. Due to the weakness
of the expected CMBP signal (in the range of microK), much care has been spent
to optimize the instrument design with respect to the systematics generation,
observing time efficiency and long term stability. In this contribution we
present the instrument design, and first tests on some components of the 32 GHz
radiometer.