Normalized to: Negri, M.
[1]
oai:arXiv.org:0810.2693 [pdf] - 17468
The Gas Pixel Detector as an X-ray photoelectric polarimeter with a
large field of view
Muleri, Fabio;
Soffitta, Paolo;
Bellazzini, Ronaldo;
Brez, Alessandro;
Costa, Enrico;
Fabiani, Sergio;
Frutti, Massimo;
Minuti, Massimo;
Negri, Maria Barbara;
Pinchera, Michele;
Rubini, Alda;
Spandre, Gloria
Submitted: 2008-10-15
The Gas Pixel Detector (GPD) is a new generation device which, thanks to its
50 um pixels, is capable of imaging the photoelectrons tracks produced by
photoelectric absorption in a gas. Since the direction of emission of the
photoelectrons is strongly correlated with the direction of polarization of the
absorbed photons, this device has been proposed as a polarimeter for the study
of astrophysical sources, with a sensitivity far higher than the instruments
flown to date. The GPD has been always regarded as a focal plane instrument and
then it has been proposed to be included on the next generation space-borne
missions together with a grazing incidence optics. Instead in this paper we
explore the feasibility of a new kind of application of the GPD and of the
photoelectric polarimeters in general, i.e. an instrument with a large field of
view. By means of an analytical treatment and measurements, we verify if it is
possible to preserve the sensitivity to the polarization for inclined beams,
opening the way for the measurement of X-ray polarization for transient
astrophysical sources. While severe systematic effects arise for inclination
greater than about 20 degrees, methods and algorithms to control them are
discussed.
[2]
oai:arXiv.org:0709.4623 [pdf] - 5478
Low energy polarization sensitivity of the Gas Pixel Detector
Muleri, F.;
Soffitta, P.;
Baldini, L.;
Bellazzini, R.;
Bregeon, J.;
Brez, A.;
Costa, E.;
Frutti, M.;
Latronico, L.;
Minuti, M.;
Negri, M. B.;
Omodei, N.;
Pinchera, M.;
Pesce-Rollins, M.;
Razzano, M.;
Rubini, A.;
Sgro', C.;
Spandre, G.
Submitted: 2007-09-28
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been
proposed to be included in many upcoming space missions to fill the gap of
about 30 years from the first (and to date only) positive measurement of
polarized X-ray emission from an astrophysical source. The estimated
sensitivity of the current prototype peaks at an energy of about 3 keV, but the
lack of readily available polarized sources in this energy range has prevented
the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector
polarimetric sensitivity at energies of a few keV and the new, light, compact
and transportable polarized source that was devised and built to this aim.
Polarized photons are produced, from unpolarized radiation generated with an
X-ray tube, by means of Bragg diffraction at nearly 45 degrees.
The employment of mosaic graphite and flat aluminum crystals allow the
production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from
the diffraction of unpolarized continuum or line emission. The measured
modulation factor of the Gas Pixel Detector at these energies is in good
agreement with the estimates derived from a Monte Carlo software, which was up
to now employed for driving the development of the instrument and for
estimating its low energy sensitivity. In this paper we present the excellent
polarimetric performance of the Gas Pixel Detector at energies where the peak
sensitivity is expected. These measurements not only support our previous
claims of high sensitivity but confirm the feasibility of astrophysical X-ray
photoelectric polarimetry.
[3]
oai:arXiv.org:0709.3978 [pdf] - 5330
A very compact polarizer for an X-ray polarimeter calibration
Muleri, Fabio;
Soffitta, Paolo;
Bellazzini, Ronaldo;
Brez, Alessandro;
Costa, Enrico;
Fabiani, Sergio;
Frutti, Massimo;
Minuti, Massimo;
Negri, Maria Barbara;
Pascale, Piermarco;
Rubini, Alda;
Sindoni, Giuseppe;
Spandre, Gloria
Submitted: 2007-09-25
We devised and built a light, compact and transportable X-ray polarized
source based on the Bragg diffraction at nearly 45 degrees. The source is
composed by a crystal coupled to a small power X-ray tube. The angles of
incidence are selected by means of two orthogonal capillary plates which, due
to the small diameter holes (10 um) allow good collimation with limited sizes.
All the orders of diffraction defined by the crystal lattice spacing are
polarized up to the maximum order limited by the X-ray tube voltage. Selecting
suitably the crystal and the X-ray tube, either the line or the continuum
emission can be diffracted, producing polarized photons at different energies.
A very high degree of polarization and reasonable fluxes can be reached with a
suitable choice of the capillary plates collimation.
We present the source and test its performances with the production of nearly
completely polarized radiation at 2.6, 5.2, 3.7 and 7.4 keV thanks to the
employment of graphite and aluminum crystals, with copper and calcium X-ray
tubes respectively. Triggered by the very compact design of the source, we also
present a feasibility study for an on-board polarized source, coupled to a
radioactive Fe55 nuclide and a PVC thin film, for the calibration of the next
generation space-borne X-ray polarimeters at 2.6 and 5.9 keV.