oai:arXiv.org:astro-ph/0703230 [pdf] - 90039
Measurement of air fluorescence light yield induced by an
electromagnetic shower
Colin, P.;
Chukanov, A.;
Grebenyuk, V.;
Naumov, D.;
Nedelec, P.;
Nefedov, Yu.;
Onofre, A.;
Porokhovoi, S.;
Sabirov, B.;
Tkatchev, L.
Submitted: 2007-03-09, last modified: 2008-10-20
For most of the Ultra-High-Energy-Cosmic-Ray (UHECR) experiments and projects
(HiRes, AUGER, TA, JEM-EUSO, TUS,...), the detection technique of Extensive Air
Showers is based, at least, on the measurement of the air-fluorescence-induced
signal. The knowledge of the Fluorescence-Light Yield (FLY) is of paramount
importance for the UHECR energy reconstruction. The MACFLY experiment was
designed to perform absolute measurements of the air FLY and to study its
properties. Here, we report the result of measurement of dry-air FLY induced by
50 GeV electromagnetic showers as a function of the shower age and as a
function of the pressure. The experiment was performed at CERN using a
SPS-electron-test-beam line. The result shows the air FLY is proportional to
the energy deposited in air (E_d). The ratio FLY/E_d and its pressure
dependence remain constant independently of shower age, and more generally,
independently of the excitation source used (single-electron track or air
shower).
[2]
oai:arXiv.org:astro-ph/0612110 [pdf] - 87448
Measurement of air and nitrogen fluorescence light yields induced by
electron beam for UHECR experiments
Colin, P.;
Chukanov, A.;
Grebenyuk, V.;
Naumov, D.;
Nedelec, P.;
Nefedov, Y.;
Onofre, A.;
Porokhovoi, S.;
Sabirov, B.;
Tkatchev, L.
Submitted: 2006-12-04
Most of the Ultra High Energy Cosmic Ray (UHECR) experiments and projects
(HiRes, AUGER, TA, EUSO, TUS,...) use air fluorescence to detect and measure
extensive air showers (EAS). The precise knowledge of the Fluorescence Light
Yield (FLY) is of paramount importance for the reconstruction of UHECR. The
MACFLY - Measurement of Air Cherenkov and Fluorescence Light Yield - experiment
has been designed to perform such FLY measurements. In this paper we will
present the results of FLY in the 290-440 nm wavelength range for dry air and
pure nitrogen, both excited by electrons with energy of 1.5 MeV, 20 GeV and 50
GeV. The experiment uses a 90Sr radioactive source for low energy measurement
and a CERN SPS electron beam for high energy. We find that the FLY is
proportional to the deposited energy (E_d) in the gas and we show that the air
fluorescence properties remain constant independently of the electron energy.
At the reference point: atmospheric dry air at 1013 hPa and 23C, the ratio
FLY/E_d=17.6 photon/MeV with a systematic error of 13.2%.