Normalized to: Narita, T.
[1]
oai:arXiv.org:1712.00148 [pdf] - 2127370
Construction of KAGRA: an Underground Gravitational Wave Observatory
Akutsu, T.;
Ando, M.;
Araki, S.;
Araya, A.;
Arima, T.;
Aritomi, N.;
Asada, H.;
Aso, Y.;
Atsuta, S.;
Awai, K.;
Baiotti, L.;
Barton, M. A.;
Chen, D.;
Cho, K.;
Craig, K.;
DeSalvo, R.;
Doi, K.;
Eda, K.;
Enomoto, Y.;
Flaminio, R.;
Fujibayashi, S.;
Fujii, Y.;
Fujimoto, M. -K.;
Fukushima, M.;
Furuhata, T.;
Hagiwara, A.;
Haino, S.;
Harita, S.;
Hasegawa, K.;
Hasegawa, M.;
Hashino, K.;
Hayama, K.;
Hirata, N.;
Hirose, E.;
Ikenoue, B.;
Inoue, Y.;
Ioka, K.;
Ishizaki, H.;
Itoh, Y.;
Jia, D.;
Kagawa, T.;
Kaji, T.;
Kajita, T.;
Kakizaki, M.;
Kakuhata, H.;
Kamiizumi, M.;
Kanbara, S.;
Kanda, N.;
Kanemura, S.;
Kaneyama, M.;
Kasuya, J.;
Kataoka, Y.;
Kawaguchi, K.;
Kawai, N.;
Kawamura, S.;
Kawazoe, F.;
Kim, C.;
Kim, J.;
Kim, J. C.;
Kim, W.;
Kimura, N.;
Kitaoka, Y.;
Kobayashi, K.;
Kojima, Y.;
Kokeyama, K.;
Komori, K.;
Kotake, K.;
Kubo, K.;
Kumar, R.;
Kume, T.;
Kuroda, K.;
Kuwahara, Y.;
Lee, H. -K.;
Lee, H. -W.;
Lin, C. -Y.;
Liu, Y.;
Majorana, E.;
Mano, S.;
Marchio, M.;
Matsui, T.;
Matsumoto, N.;
Matsushima, F.;
Michimura, Y.;
Mio, N.;
Miyakawa, O.;
Miyake, K.;
Miyamoto, A.;
Miyamoto, T.;
Miyo, K.;
Miyoki, S.;
Morii, W.;
Morisaki, S.;
Moriwaki, Y.;
Muraki, Y.;
Murakoshi, M.;
Musha, M.;
Nagano, K.;
Nagano, S.;
Nakamura, K.;
Nakamura, T.;
Nakano, H.;
Nakano, M.;
Nakano, M.;
Nakao, H.;
Nakao, K.;
Narikawa, T.;
Ni, W. -T.;
Nonomura, T.;
Obuchi, Y.;
Oh, J. J.;
Oh, S. -H.;
Ohashi, M.;
Ohishi, N.;
Ohkawa, M.;
Ohmae, N.;
Okino, K.;
Okutomi, K.;
Ono, K.;
Ono, Y.;
Oohara, K.;
Ota, S.;
Park, J.;
Arellano, F. E. Peña;
Pinto, I. M.;
Principe, M.;
Sago, N.;
Saijo, M.;
Saito, T.;
Saito, Y.;
Saitou, S.;
Sakai, K.;
Sakakibara, Y.;
Sasaki, Y.;
Sato, S.;
Sato, T.;
Sato, Y.;
Sekiguchi, T.;
Sekiguchi, Y.;
Shibata, M.;
Shiga, K.;
Shikano, Y.;
Shimoda, T.;
Shinkai, H.;
Shoda, A.;
Someya, N.;
Somiya, K.;
Son, E. J.;
Starecki, T.;
Suemasa, A.;
Sugimoto, Y.;
Susa, Y.;
Suwabe, H.;
Suzuki, T.;
Tachibana, Y.;
Tagoshi, H.;
Takada, S.;
Takahashi, H.;
Takahashi, R.;
Takamori, A.;
Takeda, H.;
Tanaka, H.;
Tanaka, K.;
Tanaka, T.;
Tatsumi, D.;
Telada, S.;
Tomaru, T.;
Tsubono, K.;
Tsuchida, S.;
Tsukada, L.;
Tsuzuki, T.;
Uchikata, N.;
Uchiyama, T.;
Uehara, T.;
Ueki, S.;
Ueno, K.;
Uraguchi, F.;
Ushiba, T.;
van Putten, M. H. P. M.;
Wada, S.;
Wakamatsu, T.;
Yaginuma, T.;
Yamamoto, K.;
Yamamoto, S.;
Yamamoto, T.;
Yano, K.;
Yokoyama, J.;
Yokozawa, T.;
Yoon, T. H.;
Yuzurihara, H.;
Zeidler, S.;
Zhao, Y.;
Zheng, L.;
Agatsuma, K.;
Akiyama, Y.;
Arai, N.;
Asano, M.;
Bertolini, A.;
Fujisawa, M.;
Goetz, R.;
Guscott, J.;
Hashimoto, Y.;
Hayashida, Y.;
Hennes, E.;
Hirai, K.;
Hirayama, T.;
Ishitsuka, H.;
Kato, J.;
Khalaidovski, A.;
Koike, S.;
Kumeta, A.;
Miener, T.;
Morioka, M.;
Mueller, C. L.;
Narita, T.;
Oda, Y.;
Ogawa, T.;
Sekiguchi, T.;
Tamura, H.;
Tanner, D. B.;
Tokoku, C.;
Toritani, M.;
Utsuki, T.;
Uyeshima, M.;
Brand, J. van den;
van Heijningen, J.;
Yamaguchi, S.;
Yanagida, A.
Submitted: 2017-11-30, last modified: 2017-12-11
Major construction and initial-phase operation of a second-generation
gravitational-wave detector KAGRA has been completed. The entire 3-km detector
is installed underground in a mine in order to be isolated from background
seismic vibrations on the surface. This allows us to achieve a good sensitivity
at low frequencies and high stability of the detector. Bare-bones equipment for
the interferometer operation has been installed and the first test run was
accomplished in March and April of 2016 with a rather simple configuration. The
initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we
summarize the construction of KAGRA, including the study of the advantages and
challenges of building an underground detector and the operation of the iKAGRA
interferometer together with the geophysics interferometer that has been
constructed in the same tunnel.
[2]
oai:arXiv.org:astro-ph/0508312 [pdf] - 1592058
Developing a Compton Polarimeter to Measure Polarization of Hard X-Rays
in the 50-300 keV Energy Range
Submitted: 2005-08-14
This paper discusses the latest progress in the development of GRAPE
(Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The
purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300
keV energy range. We are particularly interested in X-rays that are emitted
from solar flares and gamma-ray bursts (GRBs). Accurately measuring the
polarization of the emitted radiation from these sources will lead, to a better
understating of both the emission mechanisms and source geometries. The GRAPE
design consists of an array of plastic scintillators surrounding a central
high-Z crystal scintillator. We can monitor individual Compton scatters that
occur in the plastics and determine whether the photon is photo absorbed by the
high-Z crystal or not. A Compton scattered photon that is immediately photo
absorbed by the high-Z crystal constitutes a valid event. These valid events
provide us with the interaction locations of each incident photon and
ultimately produces a modulation pattern for the Compton scattering of the
polarized radiation. Comparing with Monte Carlo simulations of a 100% polarized
beam, the level of polarization of the measured beam can then be determined.
The complete array is mounted on a flat-panel multi-anode photomultiplier tube
(MAPMT) that can measure the deposited energies resulting from the photon
interactions. The design of the detector allows for a large field-of-view (>pi
steradian), at the same time offering the ability to be close-packed with
multiple modules in order to reduce deadspace. We plan to present in this paper
the latest laboratory results obtained from GRAPE using partially polarized
radiation sources.
[3]
oai:arXiv.org:astro-ph/0508314 [pdf] - 75203
GRAPE - A Balloon-Borne Gamma-Ray Polarimeter Experiment
Submitted: 2005-08-14
This paper reviews the development status of GRAPE (the Gamma-Ray Polarimeter
Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to
measure the polarization of hard X-rays in the 50-300 keV energy range. We are
particularly interested in X-rays that are emitted from solar flares and
gamma-ray bursts (GRBs), although GRAPE could also be employed in the study of
other astrophysical sources. Accurately measuring the polarization of the
emitted radiation will lead to a better understating of both emission
mechanisms and source geometries. The GRAPE design consists of an array of
plastic scintillators surrounding a central high-Z crystal scintillator. The
azimuthal distribution of photon scatters from the plastic array into the
central calorimeter provides a measure of the polarization fraction and
polarization angle of the incident radiation. The design of the detector
provides sensitivity over a large field-of-view (>pi steradian). The design
facilitates the fabrication of large area arrays with minimal deadspace. This
paper presents the latest design concept and the most recent results from
laboratory tests of a GRAPE science model.
[4]
oai:arXiv.org:astro-ph/0409085 [pdf] - 67166
Multipixel characterization of imaging CZT detectors for hard X-ray
imaging and spectroscopy
Vadawale, S. V.;
Hong, J.;
Grindlay, J.;
Williams, P.;
Zhang, M.;
Bellm, E.;
Narita, T.;
Craig, W.;
Parker, B.;
Stahle, C.;
Yan, Feng
Submitted: 2004-09-03
We report our in-depth study of Cd-Zn-Te (CZT) crystals to determine an
optimum pixel and guard band configuration for Hard X-ray imaging and
spectroscopy. We tested 20x20x5mm crystals with 8x8 pixels on a 2.46mm pitch.
We have studied different types of cathode / anode contacts and different pixel
pad sizes. We present the measurements of leakage current as well as spectral
response for each pixel. Our I-V measurement setup is custom designed to allow
automated measurements of the I-V curves sequentially for all 64 pixels,
whereas the radiation properties measurement setup allows for interchangeable
crystals with the same XAIM3.2 ASIC readout from IDEAS. We have tested multiple
crystals of each type, and each crystal in different positions to measure the
variation between individual crystals and variation among the ASIC channels. We
also compare the same crystals with and without a grounded guard band deposited
on the crystal side walls vs. a floating guard band and compare results to
simulations. This study was carried out to find the optimum CZT crystal
configuration for prototype detectors for the proposed Black-Hole Finder
mission, EXIST.
[5]
oai:arXiv.org:astro-ph/0409002 [pdf] - 67083
Laboratory coded aperture imaging experiments: radial hole coded masks
and depth-sensitive CZT detectors
Submitted: 2004-08-31
The proposed black-hole finder mission EXIST will consist of multiple
wide-field hard X-ray coded-aperture telescopes. The high science goals set for
the mission require innovations in telescope design. In particular, wide energy
band coverage and fine angular resolution require relatively thick coded masks
and thick detectors compared to their pixel size, which may introduce mask
self-collimation and depth-induced image blurring with conventional design
approaches. Previously we proposed relatively simple solutions to these
potential problems: radial hole for mask selfcollimation and cathode depth
sensing detector for image blurring. We have now performed laboratory
experiments to explore the potential of these two techniques. The experimental
results show that the radial hole mask greatly alleviates mask self-collimation
and a ~1 mm resolution depth-sensitive detector scheme can be relatively easily
achieved for the large scale required for EXIST.
[6]
oai:arXiv.org:astro-ph/0402133 [pdf] - 62647
EXITE2 Observation of the SIGMA Source GRS 1227+025
Submitted: 2004-02-05
We report the EXITE2 hard X-ray imaging of the sky around 3C273. A 2h
observation on May 8, 1997, shows a $\sim$260 mCrab source detected at
$\sim4\sigma$ in each of two bands (50-70 and 70-93 keV) and located $\sim$30'
from 3C273 and consistent in position with the SIGMA source GRS1227+025. The
EXITE2 spectrum is consistent with a power law with photon index 3 and large
low energy absorption, as indicated by the GRANAT/SIGMA results. No source was
detected in more sensitive followup EXITE2 observations in 2000 and 2001 with
3$\sigma$ upper limits of 190 and 65 mCrab, respectively. Comparison with the
flux detected by SIGMA shows the source to be highly variable, suggesting it
may be non-thermal and beamed and thus the first example of a ``type 2''
(absorbed) Blazar. Alternatively it might be (an unprecedented) very highly
absorbed binary system undergoing accretion disk instability outbursts,
possibly either a magnetic CV, or a black hole X-ray nova.
[7]
oai:arXiv.org:astro-ph/0310475 [pdf] - 60138
Cathode depth sensing in CZT detectors
Submitted: 2003-10-16
Measuring the depth of interaction in thick Cadmium-Zinc-Telluride (CZT)
detectors allows improved imaging and spectroscopy for hard X-ray imaging above
100 keV. The Energetic X-ray Imaging Survey Telescope (EXIST) will employ
relatively thick (5 - 10 mm) CZT detectors, which are required to perform the
broad energy-band sky survey. Interaction depth information is needed to
correct events to the detector "focal plane" for correct imaging and can be
used to improve the energy resolution of the detector at high energies by
allowing event-based corrections for incomplete charge collection. Background
rejection is also improved by allowing low energy events from the rear and
sides of the detector to be rejected. We present experimental results of
interaction depth sensing in a 5 mm thick pixellated Au-contact IMARAD CZT
detector. The depth sensing was done by making simultaneous measurements of
cathode and anode signals, where the interaction depth at a given energy is
proportional to the ratio of cathode/anode signals. We demonstrate how a simple
empirical formula describing the event distributions in the cathode/anode
signal space can dramatically improve the energy resolution. We also estimate
the energy and depth resolution of the detector as a function of the energy and
the interaction depth. We also show a depth-sensing prototype system currently
under development for EXIST in which cathode signals from 8, 16 or 32 crystals
can be read-out by a small multi-channel ASIC board that is vertically
edge-mounted on the cathode electrode along every second CZT crystal boundary.
This allows CZT crystals to be tiled contiguously with minimum impact on
throughput of incoming photons. The robust packaging is crucial in EXIST, which
will employ very large area imaging CZT detector arrays.
[8]
oai:arXiv.org:astro-ph/0305085 [pdf] - 56558
X-ray Dip Monitoring of XB 1916-053
Submitted: 2003-05-06
We report on the long term monitoring of X-ray dips from the ultracompact
low-mass X-ray binary (LMXB) XB 1916-053. Roughly one-month interval
observations were carried out with the Rossi X-ray Timing Explorer (RXTE)
during 1996, during which the source varied between dim, hard states and more
luminous, soft states. The dip spectra and dip lightcurves were compared
against both the broadband luminosity and the derived mass accretion rate Mdot.
The dips spectra could be fitted by an absorbed blackbody plus cut-off power
law non-dip spectral model, with additional absorption ranging from 0 to >100 x
10^22 cm^-2. The amount of additional blackbody absorption was found to vary
with the source luminosity. Our results are consistent with an obscuration of
the inner disk region by a partially ionized outer disk. The size of the
corona, derived from the dip ingress times, was found to be ~10^9 cm. The
corona size did not correlate with the coronal temperature, but seemed to
increase when \Mdot also increased. We discuss our findings in the context of
an evaporated accretion disk corona model and an ADAF-type model.
[9]
oai:arXiv.org:astro-ph/0211529 [pdf] - 53264
Background Measurements from Balloon-Borne CZT Detectors
Submitted: 2002-11-24, last modified: 2002-12-03
We report detector characteristics and background measurements from two
prototype imaging CZT detectors flown on a scientific balloon payload in May
2001. The detectors are both platinum-contact 10mm x 10mm x 5mm CZT crystals,
each with a 4 $\times$ 4 array of pixels tiling the anode. One is made from
IMARAD horizontal Bridgman CZT, the other from eV Products high-pressure
Bridgman material. Both detectors were mounted side-by-side in a flip-chip
configuration and read out by a 32-channel IDE VA/TA ASIC preamp/shaper. We
enclosed the detectors in the same 40deg field-of-view collimator (comprisinga
graded passive shield and plastic scintillator) used in our previously-reported
September 2000 flight. I-V curves for the detectors are diode-like, and we find
that the platinum contacts adhere significantly better to the CZT surfaces than
gold to previous detectors. The detectors and instrumentation performed well in
a 20-hour balloon flight on 23/24 May 2001. Although we discovered a
significant instrumental background component in flight, it was possible to
measure and subtract this component from the spectra. The resulting IMARAD
detector background spectrum (from 30 keV to ~450 keV) reaches ~5 x 10^{-3}$
counts/cm^2 -sec-keV at 100 keV and has a power-law index of ~2 at high
energies. The eV Products detector has a similar spectrum, although there is
more uncertainty in the energy scale because of calibration complications.
[10]
oai:arXiv.org:astro-ph/0110074 [pdf] - 1232753
Balloon Flight Background Measurement with Actively-Shielded Planar and
Imaging CZT Detectors
Submitted: 2001-10-03
We present results from the flight of two prototype CZT detectors on a
scientific balloon payload in September 2000. The first detector, referred to
as ``CZT1,'' consisted of a 10 mm x 10 mm x 2 mm CZT crystal with a single gold
planar electrode readout. This detector was shielded by a combination of a
passive collimator surrounded by plastic scintillator and a thick BGO crystal
in the rear. The second detector, ``CZT2,'' comprised two 10 mm x 10 mm x 5 mm
CZT crystals, one made of eV Products high pressure Bridgman material and the
other of IMARAD horizontal Bridgman material, each fashioned with a 4 x 4 array
of gold pixels on a 2.5 mm pitch. The pixellated detectors were
flip-chip-mounted side by side and read out by a 32-channel ASIC. This detector
was also shielded by a passive/plastic collimator in the front, but used only
additional passive/plastic shielding in the rear. Both experiments were flown
from Ft. Sumner, NM on September 19, 2000 on a 24 hour balloon flight. CZT1
recorded a non-vetoed background level at 100 keV of ~1e-3 cts/cm2/s/keV.
Raising the BGO threshold from 50 keV to ~1 MeV produced only an 18% increase
in this level. CZT2 recorded a background at 100 keV of ~4e-3 cts/cm2/s/keV in
the eV Products detector and ~6e-3 cts/cm2/s/keV in the IMARAD detector. Both
CZT1 and CZT2 spectra were in basic agreement with Monte Carlo simulations,
though both recorded systematically higher count rates at high energy than
predicted. No lines were observed, indicating that neutron capture reactions,
at least those producing decay lines at a few 100 keV, are not significant
components of the CZT background. Comparison of the CZT1 and CZT2 spectra
indicates that passive/plastic shielding may provide adequately low background
levels for many applications.
[11]
oai:arXiv.org:astro-ph/0109122 [pdf] - 44621
Development of an XSPEC-Based Spectral Analysis System for the
Coded-Aperture Hard X-ray Balloon Payload EXITE2
Submitted: 2001-09-07
We present the spectral analysis system for the second-generation Energetic
X-ray Imaging Telescope Experiment (EXITE2) balloon payload. EXITE2 is an
imaging hard X-ray telescope using a coded-aperture mask and a NaI/CsI phoswich
detector operating in the energy range 20--600 keV. The instrument was flown on
a high-altitude scientific balloon from Ft. Sumner, NM on 1997 May 7-8. We
describe the details of the EXITE2 spectral analysis system, with emphasis on
those aspects peculiar to coded-aperture instruments. In particular, we have
made our analysis compatible with the standard X-ray spectral fitting package
XSPEC by generating a response matrix in the appropriate format including all
the effects of a coded-aperture system. The use of XSPEC, which may be a first
for coded-aperture data, permits great flexibility in the fitting of spectral
models. The additional effects of our phoswich system, or any other
detector-specific considerations, may be easily included as well. We test our
spectral analysis using observations of the Crab Nebula, and find that the
EXITE2 Crab spectrum is consistent with those recorded by previous instruments
operating in this energy range.
[12]
oai:arXiv.org:astro-ph/0008275 [pdf] - 1232533
Development of Gold Contacted Flip-chip Detectors with IMARAD CZT
Submitted: 2000-08-17
We present initial results from our evaluation of a gold-contacted pixellated
detector using cadmium zinc telluride substrate produced by IMARAD Imaging
Systems. The Horizontal Bridgman (HB) grown crystals from IMARAD have been
shown to produce high resolution photopeaks, but they are also seen to have
large leakage current. Our previous tests with IMARAD CZT showed that the use
of indium anodes and gold cathode improved the resistivity compared to the
standard indium-contacted detectors. We seek to test whether simple evaporated
gold contacts alone could also reduce the leakage current and thus improve the
spectral resolution, especially in the 10-100 keV energy range. We have
fabricated several metal-semiconductor-metal (MSM) detectors with a 4x4 array
of pixels on 10x10 mm substrates. Measurements of the detectors' leakage
current, spectral response, and temperature sensitivity are presented and
compared to IMARAD's ohmic contact detector and gold contact MSM detectors made
of High Pressure Bridgman (HPB) material. Finally, we show preliminary results
from a tiled flip-chip pixellated detector made using the IMARAD detectors.
[13]
oai:arXiv.org:astro-ph/0008284 [pdf] - 1232535
Construction and Testing of a Pixellated CZT Detector and Shield for a
Hard X-ray Astronomy Balloon Flight
Submitted: 2000-08-17
We report on the construction and laboratory testing of pixellated CZT
detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as
required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm
detectors were fabricated, one out of standard eV Products high-pressure
Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned
with a 4 x 4 array of gold pixels on a 2.5 mm pitch with a surrounding guard
ring. The detectors were mounted side by side on a carrier card, such that the
pixel pitch was preserved, and read out by a 32-channel VA-TA ASIC from IDE AS
Corp. controlled by a PC/104 single-board computer. A passive shield/collimator
surrounded by plastic scintillator encloses the detectors on five sides and
provides a ~40deg field of view. Thus this experiment tests key techniques
required for future hard X-ray survey instruments. The experiment was taken to
Ft Sumner, NM in May 2000 in preparation for a scientific balloon flight aboard
the joint Harvard-MSFC EXITE2/HERO payload. Although we did not receive a
flight opportunity, and are currently scheduled to fly in September 2000, we
present our calibration data in the flight configuration together with data
analysis techniques and simulations of the expected flight background spectrum.
[14]
oai:arXiv.org:astro-ph/0008274 [pdf] - 1468151
ASCA Observations of GX 354-0 and KS 1731-260
Submitted: 2000-08-17
We report on ASCA observations of the low mass X-ray binaries GX 354-0 and KS
1731-260. The spectrum of GX 354-0 is best described as a power-law or a
Comptonized spectrum with tau ~ 5 and kT ~ 8 keV and a residual at ~6.5 keV.
The residual may be a disk reflection or a Compton broadened Gaussian line from
the hot inner ADAF-like coronal region. The absorption column density to the
source is 2.9e22 cm^-2. No soft thermal component was detected. The spectrum
from KS 1731-260 is softer and it is best fit with a two component model with a
column density of 1.1e22 cm^-2. The likely interpretation is emission from a
Comptonizing cloud with an optical depth tau>12 and either a neutron star or a
disk blackbody emission. We discuss the likely location of the Comptonizing
cloud for both sources within the context of several proposed emission models.
[15]
oai:arXiv.org:astro-ph/9910244 [pdf] - 1235401
Design and Testing of a Prototype Pixellated CZT Detector and Shield for
Hard X-Ray Astronomy
Submitted: 1999-10-13
We report on the design and laboratory testing of a prototype imaging CZT
detector intended for balloon flight testing in April 2000. The detector tests
several key techniques needed for the construction of large-area CZT arrays, as
required for proposed hard X-ray astronomy missions. Two 10 mm x 10 mm x 5 mm
CZT detectors, each with a 4 x 4 array of 1.9 mm pixels on a 2.5 mm pitch, will
be mounted in a ``flip-chip'' fashion on a printed circuit board carrier card;
the detectors will be placed 0.3 mm apart in a tiled configuration such that
the pixel pitch is preserved across both crystals. One detector is eV Products
high-pressure Bridgman CZT, and the other is IMARAD horizontal Bridgman
material. Both detectors are read out by a 32-channel VA-TA ASIC controlled by
a PC/104 single-board computer. A passive shield/collimator surrounded by
plastic scintillator surrounds the detectors on five sides and provides a ~45
deg field of view. The background spectrum recorded by this instrument will be
compared to that measured by a single-element CZT detector (10 mm x 10 mm x 2
mm high-pressure Bridgman material from eV Products) fitted with the same
passive/plastic collimator but including an active BGO shield to the rear. This
detector has been previously flown by us completely shielded by a passive
cover. We describe preliminary laboratory results for the various systems,
discuss initial background simulations, and describe our plans for balloon
flight tests.
[16]
oai:arXiv.org:astro-ph/9808241 [pdf] - 102585
CdZnTe Background Measurement at Balloon Altitudes
Submitted: 1998-08-21
We report results of an experiment conducted in May 1997 to measure CdZnTe
background and background reduction schemes in space flight conditions similar
to those of proposed hard X-ray astrophysics missions. A 1 cm^2 CdZnTe detector
was placed adjacent to a thick BGO anticoincidence shield and flown piggybacked
onto the EXITE2 scientific balloon payload. The planar shield was designed to
veto background countsproduced by local gamma-ray production in passive
material and neutron interactions in the detector. The CdZnTe and BGO were
partially surrounded by a Pb-Sn-Cu shield to approximate the grammage of an
X-ray collimator, although the field of view was still ~2 pi sr. At an altitude
of 127000 feet we find a reduction in background by a factor of 6 at 100 keV.
The non-vetoed background is 9 X 10^{-4} cts /cm^2-sec-keV at 100 keV, about a
factor of 2 higher than that of the collimated (4.5 deg FWHM) EXITE2 phoswich
detector. We compare our recorded spectrum with that expected from simulations
using GEANT and find agreement within a factor of 2 between 30 and 300 keV. We
also compare our results with those of previous experiments using passive lead
and active NaI shields, and discuss possible active shielding schemes in future
astronomy missions employing large arrays of CdZnTe detectors.
[17]
oai:arXiv.org:astro-ph/9806179 [pdf] - 1235230
Development of Prototype Pixellated PIN CdZnTe Detectors
Submitted: 1998-06-12
We report initial results from the design and evaluation of two pixellated
PIN Cadmium Zinc Telluride detectors and an ASIC-based readout system. The
prototype imaging PIN detectors consist of 4X4 1.5 mm square indium anode
contacts with 0.2 mm spacing and a solid cathode plane on 10X10 mm CdZnTe
substrates of thickness 2 mm and 5 mm. The detector readout system, based on
low noise preamplifier ASICs, allows for parallel readout of all channels upon
cathode trigger. This prototype is under development for use in future
astrophysical hard X-ray imagers with 10-600 keV energy response. Measurements
of the detector uniformity, spatial resolution, and spectral resolution will be
discussed and compared with a similar pixellated MSM detector. Finally, a
prototype design for a large imaging array is outlined.
[18]
oai:arXiv.org:astro-ph/9801156 [pdf] - 100005
Prototype Imaging Cd-Zn-Te Array Detector
Submitted: 1998-01-15
We describe initial results of our program to develop and test Cd-Zn-Te (CZT)
detectors with a pixellated array readout. Our primary interest is in the
development of relatively thick CZT detectors for use in astrophysical coded
aperture telescopes with response extending over the energy range $\sim 10-600$
keV. The coded aperture imaging configuration requires only relatively large
area pixels (1-3 mm), whereas the desired high energy response requires
detector thicknesses of at least 3-5 mm. We have developed a prototype detector
employing a 10 x 10 x 5 mm CZT substrate and 4 x 4 pixel (1.5 mm each) readout
with gold metal contacts for the pixels and continuous gold contact for the
bias on the opposite detector face. This MSM contact configuration was
fabricated by RMD and tested at Harvard for uniformity, efficiency and spatial
as well as spectral resolution. We have developed an ASIC readout (IDE-VA-1)
and analysis system and report results, including $\sim 4$% (FWHM) energy
resolution at 60 keV. A prototype design for a full imaging detector array is
discussed.
[19]
oai:arXiv.org:astro-ph/9705198 [pdf] - 97460
A Search for Very High Energy Neutrinos from Active Galactic Nuclei
Bolesta, J. W.;
Bradner, H.;
Camerini, U.;
Clem, J.;
Dye, S. T.;
George, J.;
Gorham, P. W.;
Grieder, P. K. F.;
Hauptman, J.;
Hayashino, T.;
Jaworski, M.;
Kitamura, T.;
Kondo, S.;
Learned, J. G.;
March, R.;
Matsumoto, T.;
Matsuno, S.;
Mauritz, K.;
Minkowski, P.;
Narita, T.;
O'Connor, D. J.;
Ohashi, Y.;
Okada, A.;
Peterson, V.;
Stenger, V. J.;
Uehara, S.;
Webster, M.;
Wilkes, R. J.;
Young, K. K.;
Yamaguchi, A.
Submitted: 1997-05-24, last modified: 1997-05-27
We report the results of a search for neutrino-induced particle cascades
using a deep ocean water Cherenkov detector. The effective mass of the
detector, a string of seven 40 cm diameter photomultipliers at 5.2 m spacing,
is found through simulation analysis to be surprisingly large: greater than 1
megaton of water at incident neutrino energies of 1 PeV. We find no evidence
for neutrino-induced cascades in 18.6 hours of observation. Although the limit
implied by this observation is the strongest yet for predictions of active
galatic nuclei (AGN) neutrinos at energies above 100 TeV, perhaps the more
intriguing result is that the power of these techniques can be exploited to
test these AGN models in a relatively short time.