Nakamasu, Yuma
Normalized to: Nakamasu, Y.
2 article(s) in total. 19 co-authors, from 1 to 2 common article(s). Median position in authors list is 12,5.
[1]
oai:arXiv.org:1703.07600 [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an
Electron-Tracking Compton Camera
Komura, Shotaro;
Takada, Atsushi;
Mizumura, Yoshitaka;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tanimori, Toru;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and
the magnetic configuration of various celestial objects, such as binary black
holes or gamma-ray bursts (GRBs). However, statistically significant
polarizations have been detected in few of the brightest objects. Even though
future polarimeters using X-ray telescopes are expected to observe weak
persistent sources, there are no effective approaches to survey transient and
serendipitous sources with a wide field of view (FoV). Here we present an
electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging
polarimeter. The ETCC provides powerful background rejection and a high
modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging
based on a well-defined point spread function. Importantly, we demonstrated for
the first time the stability of the modulation factor under realistic
conditions of off-axis incidence and huge backgrounds using the SPring-8
polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$
0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$
and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis
incidence. These measured results are consistent with the simulation results.
Consequently, we found that the satellite-ETCC proposed in Tanimori et al.
(2015) would provide all-sky surveys of weak persistent sources of 13 mCrab
with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a
$6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year
observation.
[2]
oai:arXiv.org:1702.01483 [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on
Geometrical Optics
Tanimori, Toru;
Mizumura, Yoshitaka;
Takada, Atsushi;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Komura, Shotaro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to
pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does
not keep physical information (intensity, or brightness in Optics) along a ray,
and thus is capable of no more than qualitative imaging of bright objects. To
attain quantitative imaging, cameras that realize geometrical optics is
essential, which would be, for nuclear MeV gammas, only possible via complete
reconstruction of the Compton process. Recently we have revealed that "Electron
Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function
(PSF). The information of an incoming gamma is kept along a ray with the PSF
and that is equivalent to geometrical optics. Here we present an
imaging-spectroscopic measurement with the ETCC. Our results highlight the
intrinsic difficulty with CCs in performing accurate imaging, and show that the
ETCC surmounts this problem. The imaging capability also helps the ETCC
suppress the noise level dramatically by ~3 orders of magnitude without a
shielding structure. Furthermore, full reconstruction of Compton process with
the ETCC provides spectra free of Compton edges. These results mark the first
proper imaging of nuclear gammas based on the genuine geometrical optics.