Normalized to: Naik, N.
[1]
oai:arXiv.org:1904.08867 [pdf] - 1898022
A joint deconvolution algorithm to combine single dish and
interferometer data for wideband multi-term and mosaic imaging
Submitted: 2019-04-18
Imaging in radio astronomy is usually carried out with a single-dish radio
telescope doing a raster scan of a region of the sky or with an interferometer
that samples the visibility function of the sky brightness. Mosaic observations
are the current standard for imaging large fields of view with an
interferometer and multi-frequency observations are now routinely carried out
with both types of telescopes to increase the continuum imaging sensitivity and
to probe spectral structure. This paper describes an algorithm to combine
wideband data from these two types of telescopes in a joint iterative
reconstruction scheme that can be applied to spectral cube or wideband
multi-term imaging both for narrow fields of view as well as mosaics. Our
results demonstrate the ability to prevent instabilities and error that
typically arise when wide-band or joint mosaicing algorithms are presented with
spatial and spectral structure that is inadequetely sampled by the
interferometer alone. For comparable noise levels in the single dish and
interferometer data, the numerical behaviour of this algorithm is expected to
be similar to the idea of generating artificial visibilities from single dish
data. However, our discussed implementation is simpler and more flexible in
terms of applying relative data weighting schemes to match noise levels while
preserving flux accuracy, fits within standard iterative image reconstruction
frameworks, is fully compatible with wide-field and joint mosaicing gridding
algorithms that apply corrections specific to the interferometer data and may
be configured to enable spectral cube and wideband multi-term deconvolution for
single-dish data alone.