Normalized to: Nagler, P.
[1]
oai:arXiv.org:1903.09718 [pdf] - 1924108
Observing exoplanets in the near-infrared from a high altitude balloon
platform
Nagler, Peter C.;
Edwards, Billy;
Kilpatrick, Brian;
Lewis, Nikole K.;
Maxted, Pierre;
Netterfield, C. Barth;
Parmentier, Vivien;
Pascale, Enzo;
Sarkar, Subhajit;
Tucker, Gregory S.;
Waldmann, Ingo
Submitted: 2019-03-22, last modified: 2019-07-29
Although there exists a large sample of known exoplanets, little
spectroscopic data exists that can be used to study their global atmospheric
properties. This deficiency can be addressed by performing phase-resolved
spectroscopy -- continuous spectroscopic observations of a planet's entire
orbit about its host star -- of transiting exoplanets. Planets with
characteristics suitable for atmospheric characterization have orbits of
several days, thus phase curve observations are highly resource intensive,
especially for shared use facilities. In this work, we show that an infrared
spectrograph operating from a high altitude balloon platform can perform
phase-resolved spectroscopy of hot Jupiter-type exoplanets with performance
comparable to a space-based telescope. Using the EXoplanet Climate Infrared
TElescope (EXCITE) experiment as an example, we quantify the impact of the most
important systematic effects that we expect to encounter from a balloon
platform. We show an instrument like EXCITE will have the stability and
sensitivity to significantly advance our understanding of exoplanet
atmospheres. Such an instrument will both complement and serve as a critical
bridge between current and future space-based near infrared spectroscopic
instruments.
[2]
oai:arXiv.org:1811.11313 [pdf] - 1791684
SOFIA - HIRMES: Looking forward to the HIgh-Resolution Mid-infrarEd
Spectrometer
Richards, Samuel N.;
Moseley, Samuel H.;
Stacey, Gordon;
Greenhouse, Matthew;
Kutyrev, Alexander;
Arendt, Richard;
Atanasoff, Hristo;
Banks, Stuart;
Brekosky, Regis P.;
Brown, Ari-David;
Bulcha, Berhanu;
Cazeau, Tony;
Choi, Michael;
Colazo, Felipe;
Engler, Chuck;
Hadjimichael, Theodore;
Hays-Wehle, James;
Henderson, Chuck;
Hsieh, Wen-Ting;
Huang, Jeffrey;
Jenstrom, Iver;
Kellogg, Jim;
Kimball, Mark;
Kovacs, Attila;
Leiter, Steve;
Maher, Steve;
McMurray, Robert;
Melnick, Gary J.;
Mentzell, Eric;
Mikula, Vilem;
Miller, Timothy M.;
Nagler, Peter;
Nikola, Thomas;
Oxborrow, Joseph;
Pontoppidan, Klaus M.;
Rangwala, Naseem;
Rhodes, Alan;
Roberge, Aki;
Rosner, Stefan;
Rostem, Karwan;
Rustemeyer, Nancy;
Sharp, Elmer;
Sparr, Leroy;
Stevanovic, Dejan;
Taraschi, Peter;
Temi, Pasquale;
Vacca, William D.;
de Lorenzo, Jordi Vila Hernandez;
Wohler, Bill;
Wollack, Edward J.;
Wilks, Shannon
Submitted: 2018-11-27
The HIgh-Resolution Mid-infrarEd Spectrometer (HIRMES) is the 3rd Generation
Instrument for the Stratospheric Observatory For Infrared Astronomy (SOFIA),
currently in development at the NASA Goddard Space Flight Center (GSFC), and
due for commissioning in 2019. By combining direct-detection Transition Edge
Sensor (TES) bolometer arrays, grating-dispersive spectroscopy, and a host of
Fabry-Perot tunable filters, HIRMES will provide the ability for High
Resolution (R~100,000), Mid-Resolution (R~10,000), and Low-Resolution (R~600)
slit-spectroscopy, and 2D Spectral Imaging (R~2000 at selected wavelengths)
over the 25 - 122 {\mu}m mid-far infrared waveband. The driving science
application is the evolution of proto-planetary systems via measurements of
water-vapor, water-ice, deuterated hydrogen (HD), and neutral oxygen lines.
However, HIRMES has been designed to be as flexible as possible to cover a wide
range of science cases that fall within its phase-space, all whilst reaching
sensitivities and observing powers not yet seen thus far on SOFIA, providing
unique observing capabilities which will remain unmatched for decades.
[3]
oai:arXiv.org:1611.04466 [pdf] - 1513841
Multimode bolometer development for the PIXIE instrument
Submitted: 2016-11-14
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission
concept designed to measure the polarization and absolute intensity of the
cosmic microwave background. In the following, we report on the design,
fabrication, and performance of the multimode polarization-sensitive bolometers
for PIXIE, which are based on silicon thermistors. In particular we focus on
several recent advances in the detector design, including the implementation of
a scheme to greatly raise the frequencies of the internal vibrational modes of
the large-area, low-mass optical absorber structure consisting of a grid of
micromachined, ion-implanted silicon wires. With $\sim30$ times the absorbing
area of the spider-web bolometers used by Planck, the tensioning scheme enables
the PIXIE bolometers to be robust in the vibrational and acoustic environment
at launch of the space mission. More generally, it could be used to reduce
microphonic sensitivity in other types of low temperature detectors. We also
report on the performance of the PIXIE bolometers in a dark cryogenic
environment.
[4]
oai:arXiv.org:1510.08089 [pdf] - 1315032
Systematic effects in polarizing Fourier transform spectrometers for
cosmic microwave background observations
Submitted: 2015-10-27
The detection of the primordial B-mode polarization signal of the cosmic
microwave background (CMB) would provide evidence for inflation. Yet as has
become increasingly clear, the detection of a such a faint signal requires an
instrument with both wide frequency coverage to reject foregrounds and
excellent control over instrumental systematic effects. Using a polarizing
Fourier transform spectrometer (FTS) for CMB observations meets both these
requirements. In this work, we present an analysis of instrumental systematic
effects in polarizing Fourier transform spectrometers, using the Primordial
Inflation Explorer (PIXIE) as a worked example. We analytically solve for the
most important systematic effects inherent to the FTS - emissive optical
components, misaligned optical components, sampling and phase errors, and spin
synchronous effects - and demonstrate that residual systematic error terms
after corrections will all be at the sub-nK level, well below the predicted 100
nK B-mode signal.