sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Murray, G. J.

Normalized to: Murray, G.

17 article(s) in total. 192 co-authors, from 1 to 9 common article(s). Median position in authors list is 4,0.

[1]  oai:arXiv.org:1811.03383  [pdf] - 1791342
Design and production of the DESI fibre cables
Comments: SPIE conference proceedings article of "Astronomical Telescopes and Instrumentation 2018" conference, Austin, Texas, USA
Submitted: 2018-11-08
The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the Universe using the Baryonic Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 sq deg will be measured during the life of the experiment. A new prime focus corrector for the KPNO Mayall telescope will deliver light to 5000 fibre optic positioners. The fibres in turn feed 10 broad-band spectrographs. We will describe the design and production progress on the fibre cables, strain relief system and preparation of the slit end. In contrast to former projects, the larger scale of production required for DESI requires teaming up with industry to find a solution to reduce the time scale of production as well as to minimise the stress on the optical fibres.
[2]  oai:arXiv.org:1608.01075  [pdf] - 1531175
Prime Focus Spectrograph (PFS) for the Subaru Telescope: Overview, recent progress, and future perspectives
Tamura, Naoyuki; Takato, Naruhisa; Shimono, Atsushi; Moritani, Yuki; Yabe, Kiyoto; Ishizuka, Yuki; Ueda, Akitoshi; Kamata, Yukiko; Aghazarian, Hrand; Arnouts, Stephane; Barban, Gabriel; Barkhouser, Robert H.; Borges, Renato C.; Braun, David F.; Carr, Michael A.; Chabaud, Pierre-Yves; Chang, Yin-Chang; Chen, Hsin-Yo; Chiba, Masashi; Chou, Richard C. Y.; Chu, You-Hua; Cohen, Judith G.; de Almeida, Rodrigo P.; de Oliveira, Antonio C.; de Oliveira, Ligia S.; Dekany, Richard G.; Dohlen, Kjetil; Santos, Jesulino B. dos; Santos, Leandro H. dos; Ellis, Richard S.; Fabricius, Maximilian; Ferrand, Didier; Ferreira, Decio; Golebiowski, Mirek; Greene, Jenny E.; Gross, Johannes; Gunn, James E.; Hammond, Randolph; Harding, Albert; Hart, Murdock; Heckman, Timothy M.; Hirata, Christopher M.; Ho, Paul; Hope, Stephen C.; Hovland, Larry; Hsu, Shu-Fu; Hu, Yen-Shan; Huang, Ping-Jie; Jaquet, Marc; Jing, Yipeng; Karr, Jennifer; Kimura, Masahiko; King, Matthew E.; Komatsu, Eiichiro; Brun, Vincent Le; Fevre, Olivier Le; Fur, Arnaud Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig P.; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas S.; de Oliveira, Claudia Mendes; Minowa, Yosuke; Morantz, Chaz N.; Murayama, Hitoshi; Murray, Graham J.; Ohyama, Youichi; Orndorff, Joseph; Pascal, Sandrine; Pereira, Jefferson M.; Reiley, Daniel J.; Reinecke, Martin; Ritter, Andreas; Roberts, Mitsuko; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Sodre, Laerte; Spergel, David N.; Steinkraus, Aaron J.; Strauss, Michael A.; Surace, Christian; Suto, Yasushi; Suzuki, Nao; Swinbank, John; Tait, Philip J.; Takada, Masahiro; Tamura, Tomonori; Tanaka, Yoko; Tresse, Laurence; Verducci, Orlando; Vibert, Didier; Vidal, Clement; Wang, Shiang-Yu; Wen, Chih-Yi; Yan, Chi-Hung; Yasuda, Naoki
Comments: 17 pages, 10 figures. Proceeding of SPIE Astronomical Telescopes and Instrumentation 2016
Submitted: 2016-08-03
PFS (Prime Focus Spectrograph), a next generation facility instrument on the 8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed, optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394 reconfigurable fibers will be distributed over the 1.3 deg field of view. The spectrograph has been designed with 3 arms of blue, red, and near-infrared cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure at a resolution of ~1.6-2.7A. An international collaboration is developing this instrument under the initiative of Kavli IPMU. The project is now going into the construction phase aiming at undertaking system integration in 2017-2018 and subsequently carrying out engineering operations in 2018-2019. This article gives an overview of the instrument, current project status and future paths forward.
[3]  oai:arXiv.org:1608.00675  [pdf] - 1531167
The Current Status of Prime Focus Instrument of Subaru Prime Focus Spectrograph
Comments: 9 pages, 8 figures, SPIE proceeding
Submitted: 2016-08-01
The Prime Focus Spectrograph (PFS) is a new optical/near-infrared multi-fiber spectrograph design for the prime focus of the 8.2m Subaru telescope. PFS will cover 1.3 degree diameter field with 2394 fibers to complement the imaging capability of Hyper SuprimeCam (HSC). The prime focus unit of PFS called Prime Focus Instrument (PFI) provides the interface with the top structure of Subaru telescope and also accommodates the optical bench in which Cobra fiber positioners are located. In addition, the acquisition and guiding cameras (AGCs), the optical fiber positioner system, the cable wrapper, the fiducial fibers, illuminator, and viewer, the field element, and the telemetry system are located inside the PFI. The mechanical structure of the PFI was designed with special care such that its deflections sufficiently match those of the HSC's Wide Field Corrector (WFC) so the fibers will stay on targets over the course of the observations within the required accuracy. In this report, the latest status of PFI development will be given including the performance of PFI components, the setup and performance of the integration and testing equipment.
[4]  oai:arXiv.org:1507.00725  [pdf] - 1241387
Prime Focus Spectrograph for the Subaru telescope: massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio Vital; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsu, Shu-Fu; Hu, Yen-Shan; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Fèvre, Olivier Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas Souza; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D.; Vilaça, Rodrigo de Paiva; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; Santos, Jesulino Bispo dos; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung
Comments: 19 pages, 11 figures
Submitted: 2015-07-02
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber spectrograph with 2394 science fibers distributed across a 1.3-deg diameter field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from 0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously strengthens its ability to target three main survey programs: cosmology, galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available by simply exchanging dispersers. We highlight some of the technological aspects of the design. To transform the telescope focal ratio, a broad-band coated microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of the cable system, optimizing overall throughput; a fiber with low focal ratio degradation is selected for the fiber-positioner and fiber-slit components, minimizing the effects of fiber movements and fiber bending. Fiber positioning will be performed by a positioner consisting of two stages of piezo-electric rotary motors. The positions of these motors are measured by taking an image of artificially back-illuminated fibers with the metrology camera located in the Cassegrain container; the fibers are placed in the proper location by iteratively measuring and then adjusting the positions of the motors. Target light reaches one of the four identical fast-Schmidt spectrograph modules, each with three arms. The PFS project has passed several project-wide design reviews and is now in the construction phase.
[5]  oai:arXiv.org:1408.3066  [pdf] - 863489
Studying focal ratio degradation of optical fibers for Subaru Prime Focus Spectrograph
Comments: 6 Pages, 10 Figures
Submitted: 2014-08-13
Focal Ration Degradation (FRD) is a change in light angular distribution caused by fiber optics. FRD is important to fiber-fed, spectroscopic astronomical systems because it can cause loss of signal, degradation in spectral resolution, or increased complexity in spectrograph design. Laborat\'orio Nacional de Astrof\'isica (LNA) has developed a system that can accurately and precisely measures FRD, using an absolute method that can also measure fiber throughput. This paper describes the metrology system and shows measurements of Polymicro fiber FBP129168190, FBP127165190 and Fujikura fiber 128170190. Although the FRD of the two fibers are low and similar to one another, it is very important to know the exact characteristics of these fibers since both will be used in the construction of FOCCoS (Fiber Optical Cable and Connectors System) for PFS (Prime Focus Spectrograph) to be installed at the Subaru telescope.
[6]  oai:arXiv.org:1408.2847  [pdf] - 863451
Fiber Optical Cable and Connector System (FOCCoS) for PFS/Subaru
Comments: 11 pages, 20 figures
Submitted: 2014-08-12
FOCCoS, Fiber Optical Cable and Connector System, has the main function of capturing the direct light from the focal plane of Subaru Telescope using optical fibers, each one with a microlens in its tip, and conducting this light through a route containing connectors to a set of four spectrographs. The optical fiber cable is divided in 3 different segments called Cable A, Cable B and Cable C. Multi-fibers connectors assure precise connection among all optical fibers of the segments, providing flexibility for instrument changes. To assure strong and accurate connection, these sets are arranged inside two types of assemblies: the Tower Connector, for connection between Cable C and Cable B; and the Gang Connector, for connection between Cable B and Cable A. Throughput tests were made to evaluate the efficiency of the connections. A lifetime test connection is in progress. Cable C is installed inside the PFI, Prime Focus Instrument, where each fiber tip with a microlens is bonded to the end of the shaft of a 2-stage piezo-electric rotatory motor positioner; this assembly allows each fiber to be placed anywhere within its patrol region, which is 9.5mm diameter.. Each positioner uses a fiber arm to support the ferrule, the microlens, and the optical fiber. 2400 of these assemblies are arranged on a motor bench plate in a hexagonal-closed-packed disposition.
[7]  oai:arXiv.org:1408.2825  [pdf] - 1216260
Progress with the Prime Focus Spectrograph for the Subaru Telescope: a massively multiplexed optical and near-infrared fiber spectrograph
Sugai, Hajime; Tamura, Naoyuki; Karoji, Hiroshi; Shimono, Atsushi; Takato, Naruhisa; Kimura, Masahiko; Ohyama, Youichi; Ueda, Akitoshi; Aghazarian, Hrand; de Arruda, Marcio Vital; Barkhouser, Robert H.; Bennett, Charles L.; Bickerton, Steve; Bozier, Alexandre; Braun, David F.; Bui, Khanh; Capocasale, Christopher M.; Carr, Michael A.; Castilho, Bruno; Chang, Yin-Chang; Chen, Hsin-Yo; Chou, Richard C. Y.; Dawson, Olivia R.; Dekany, Richard G.; Ek, Eric M.; Ellis, Richard S.; English, Robin J.; Ferrand, Didier; Ferreira, Décio; Fisher, Charles D.; Golebiowski, Mirek; Gunn, James E.; Hart, Murdock; Heckman, Timothy M.; Ho, Paul T. P.; Hope, Stephen; Hovland, Larry E.; Hsuc, Shu-Fu; Hu, Yen-Shan; Huang, Pin Jie; Jaquet, Marc; Karr, Jennifer E.; Kempenaar, Jason G.; King, Matthew E.; Fèvre, Olivier Le; Mignant, David Le; Ling, Hung-Hsu; Loomis, Craig; Lupton, Robert H.; Madec, Fabrice; Mao, Peter; Marrara, Lucas Souza; Ménard, Brice; Morantz, Chaz; Murayama, Hitoshi; Murray, Graham J.; de Oliveira, Antonio Cesar; de Oliveira, Claudia Mendes; de Oliveira, Ligia Souza; Orndorff, Joe D.; Vilaça, Rodrigo de Paiva; Partos, Eamon J.; Pascal, Sandrine; Pegot-Ogier, Thomas; Reiley, Daniel J.; Riddle, Reed; Santos, Leandro; Santos, Jesulino Bispo dos; Schwochert, Mark A.; Seiffert, Michael D.; Smee, Stephen A.; Smith, Roger M.; Steinkraus, Ronald E.; Sodré, Laerte; Spergel, David N.; Surace, Christian; Tresse, Laurence; Vidal, Clément; Vives, Sebastien; Wang, Shiang-Yu; Wen, Chih-Yi; Wu, Amy C.; Wyse, Rosie; Yan, Chi-Hung
Comments: 14 pages, 12 figures, submitted to "Ground-based and Airborne Instrumentation for Astronomy V, Suzanne K. Ramsay, Ian S. McLean, Hideki Takami, Editors, Proc. SPIE 9147 (2014)"
Submitted: 2014-08-12
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber spectrograph with 2394 science fibers, which are distributed in 1.3 degree diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000, strengthens its ability to target three main survey programs: cosmology, Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply exchanging dispersers. PFS takes the role for the spectroscopic part of the Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam works on the imaging part. To transform the telescope plus WFC focal ratio, a 3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip. A higher transmission fiber is selected for the longest part of cable system, while one with a better FRD performance is selected for the fiber-positioner and fiber-slit components, given the more frequent fiber movements and tightly curved structure. Each Fiber positioner consists of two stages of piezo-electric rotary motors. Its engineering model has been produced and tested. Fiber positioning will be performed iteratively by taking an image of artificially back-illuminated fibers with the Metrology camera located in the Cassegrain container. The camera is carefully designed so that fiber position measurements are unaffected by small amounts of high special-frequency inaccuracies in WFC lens surface shapes. Target light carried through the fiber system reaches one of four identical fast-Schmidt spectrograph modules, each with three arms. Prototype VPH gratings have been optically tested. CCD production is complete, with standard fully-depleted CCDs for red arms and more-challenging thinner fully-depleted CCDs with blue-optimized coating for blue arms.
[8]  oai:arXiv.org:1309.6569  [pdf] - 1179491
End effects in optical fibres
Comments: Accepted for publication by MNRAS
Submitted: 2013-09-25
The performance of highly-multiplexed spectrographs is limited by focal degradation (FRD) in the optical fibres. It has already been shown that this is caused mainly by processes concentrated around the mounting points at the ends of the fibres. We use the thickness of rings produced in the farfield when a fibre is illuminated by a collimated beam, to estimate the size of the region where the FRD is generated. This requires the development of a new model, using features of existing ray-tracing and wave-based models, which fits existing data very well. The results suggest that the amount of FRD is primarily determined by the length of fibre bonded into the supporting ferrule. We point out the implications for the production of future fibre systems.
[9]  oai:arXiv.org:1207.4512  [pdf] - 1124942
Simulation of complex phenomena in optical fibres
Comments: Accepted for publication in Monthly Notices of the Royal Astronomical Society 18 July 2012
Submitted: 2012-07-18
Optical fibres are essential for many types of highly-multiplexed and precision spectroscopy. The success of the new generation of multifibre instruments under construction to investigate fundamental problems in cosmology, such as the nature of dark energy, requires accurate modellisation of the fibre system to achieve their signal-to-noise goals. Despite their simple construction, fibres exhibit unexpected behaviour including non-conservation of Etendue (Focal Ratio Degradation; FRD) and modal noise. Furthermore, new fibre geometries (non-circular or tapered) have become available to improve the scrambling properties that, together with modal noise, limit the achievable SNR in precision spectroscopy. These issues have often been addressed by extensive tests on candidate fibres and their terminations but these are difficult and time-consuming. Modelling by ray-tracing and wave analysis is possible with commercial software packages but these do not address the more complex features, in particular FRD. We use a phase-tracking ray-tracing method to provide a practical description of FRD derived from our previous experimental work on circular fibres and apply it to non-standard fibres. This allows the relationship between scrambling and FRD to be quantified for the first time. We find that scrambling primarily affects the shape of the near-field pattern but has negligible effect on the barycentre. FRD helps to homogenise the nearfield pattern but does not make it completely uniform. Fibres with polygonal cross-section improve scrambling without amplifying the FRD. Elliptical fibres, in conjunction with tapering, may offer an efficient means of image slicing to improve the product of resolving power and throughput but the result is sensitive to the details of illumination.
[10]  oai:arXiv.org:1106.1288  [pdf] - 1077115
Modal noise prediction in fibre-spectroscopy I: Visibility and the coherent model
Comments: 10 pages, 15 figures, to appear in MNRAS
Submitted: 2011-06-07
Fibre modal noise occurs in high spectral resolution, high signal-to-noise applications. It imposes fundamental limits on the photometric accuracy of state-of-the-art fibre-spectrograph systems. In order to maximize the performance of current and future instruments it is therefore essential to predict fibre modal noise. To attain a predictive model we are using a dual approach, bringing theoretical assumptions in line with the experimental data obtained using a test-bench spectrograph. We show that the task of noise prediction can be reduced to determining the visibility of the modal pattern which can be measured at the detector plane. Subsequently, the visibility-dependence of essential parameters is presented. This work will soon provide a basis for prediction of modal noise limitations in fibre-coupled spectrograph designs.
[11]  oai:arXiv.org:1006.3102  [pdf] - 190657
The Fibre Multi-Object Spectrograph (FMOS) for Subaru Telescope
Comments: Accepted for publication in PASJ, 12 pages, 23 figures
Submitted: 2010-06-15
Fibre Multi-Object Spectrograph (FMOS) is the first near-infrared instrument with a wide field of view capable of acquiring spectra simultaneously from up to 400 objects. It has been developed as a common-use instrument for the F/2 prime-focus of the Subaru Telescope. The field coverage of 30' diameter is achieved using a new 3-element corrector optimized in the near-infrared (0.9-1.8um) wavelength range. Due to limited space at the prime-focus, we have had to develop a novel fibre positioner called "Echidna" together with two OH-airglow suppressed spectrographs. FMOS consists of three subsystems: the prime focus unit for IR, the fibre positioning system/connector units, and the two spectrographs. After full systems integration, FMOS was installed on the telescope in late 2007. Many aspects of performance were checked through various test and engineering observations. In this paper, we present the optical and mechanical components of FMOS and show the results of our on-sky engineering observations to date.
[12]  oai:arXiv.org:0908.1319  [pdf] - 1003360
Strategies for spectroscopy on Extremely Large Telescopes. II - Diverse field spectroscopy
Comments: Accepted by MNRAS
Submitted: 2009-08-10
The fields of view of Extremely Large Telescopes will contain vast numbers of spatial sampling elements (spaxels) as their Adaptive Optics systems approach the diffraction limit over wide fields. Since this will exceed the detection capabilities of any realistic instrument, the field must be dilutely sampled to extract spectroscopic data from selected regions of interest. The scientific return will be maximised if the sampling pattern provides an adaptable combination of separated independent spaxels and larger contiguous sub-fields, seamlessly combining integral-field and multiple-object spectroscopy. We illustrate the utility of this Diverse Field Spectroscopy (DFS) to cosmological studies of galaxy assembly. We show how to implement DFS with an instrument concept: the Celestial Selector. This integrates highly-multiplexed monolithic fibre systems (MFS) and switching networks of the type currently available in the telecommunications industry. It avoids bulky moving parts, whose limitations were noted in Paper I. In Paper III we will investigate the optimisation of such systems by varying the input-output mapping.
[13]  oai:arXiv.org:0908.1323  [pdf] - 1003361
Strategies for spectroscopy on Extremely Large Telescope. III - Remapping switched fibre systems
Comments: Accepted by MNRAS
Submitted: 2009-08-10
We explore the use of remapping techniques to improve the efficiency of highly-multiplexed fibre systems for astronomical spectroscopy. This is particularly important for the implementation of Diverse Field Spectroscopy (DFS, described in Paper II) using highly-multiplexed monolithic fibre systems (MFS). Diverse Field Spectroscopy allows arbitrary distributions of target regions to be addressed to optimise observing efficiency when observing complex, clumpy structures such as protoclusters which will be increasingly accessible to Extremely Large Telescopes (ELTS). We show how the adoption of various types of remapping between the input and output of a Monolithic Fibre Systems can allow contiguous regions of spatial elements to be selected using only simple switch arrays. Finally we show how this compares in efficiency with integral-field and multiobject spectroscopy by simulations using artificial and real catalogues of objects. With the adoption of these mapping strategies, DFS outperforms other techniques when addressing a range of realistic target distributions. These techniques are also applicable to bio-medical science and were in fact inspired by it.
[14]  oai:arXiv.org:astro-ph/0609069  [pdf] - 260784
Cryogenic tests of volume-phase holographic gratings: results at 100 K
Comments: 10 pages, 9 figures
Submitted: 2006-09-04
We present results from cryogenic tests of Volume-Phase Holographic(VPH) gratings at 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed 10 cycles between room temperature and 100 $K$, and find no clear evidence that the diffraction efficiency changes with temperature or with successive thermal cycle.
[15]  oai:arXiv.org:astro-ph/0509913  [pdf] - 76494
Measurement of Throughput Variation Across A Large Format Volume-Phase Holographic Grating
Comments: 12 pages
Submitted: 2005-09-30
In this paper, we report measurements of diffraction efficiency and angular dispersion for a large format (~ 25 cm diameter) Volume-Phase Holographic (VPH) grating optimized for near-infrared wavelengths (0.9 -- 1.8 micron). The aim of this experiment is to see whether optical characteristics vary significantly across the grating. We sampled three positions in the grating aperture with a separation of 5 cm between each. A 2 cm diameter beam is used to illuminate the grating. At each position, throughput and diffraction angle were measured at several wavelengths. It is found that whilst the relationship between diffraction angle and wavelength is nearly the same at the three positions, the throughputs vary by up to ~ 10% from position to position. We explore the origin of the throughput variation by comparing the data with predictions from coupled-wave analysis. We find that it can be explained by a combination of small variations over the grating aperture in gelatin depth and/or refractive index modulation amplitude, and amount of energy loss by internal absorption and/or surface reflection.
[16]  oai:arXiv.org:astro-ph/0311517  [pdf] - 61097
Cryogenic Tests of Volume-Phase Holographic Gratings: I. Results at 200 K
Comments: 14 pages, 7 figures, accepted for publication in Experimental Astronomy. A version including figures with higher quality (PDF file) is available from http://star-www.dur.ac.uk/~naoyuki/vph.pdf
Submitted: 2003-11-22
We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH grating are significantly different at a low temperature from those at a room temperature, and to see how many cooling and heating cycles the grating can withstand. We have completed 5 cycles between room temperature and 200 K, and find that the performance is nearly independent of temperature, at least over the temperature range which we are investigating. In future, we will not only try more cycles between these temperatures but also perform measurements at a much lower temperature (e.g., 80 K).
[17]  oai:arXiv.org:astro-ph/0202330  [pdf] - 47824
The GMOS integral field unit: first integral field spectroscopy with an 8m telescope
Comments: 12 pages including 7 figures (Figs 1 and 7 compressed with loss of quality to reduce file size as requested by archive). Invited talk at "Galaxies: The third dimension" conference, December 3-7 2001, Cozumel Mexico. To be published in the Conference Series of the Astronomical Society of the Pacific
Submitted: 2002-02-18
The Gemini Multiobject Spectrograph (GMOS) installed on the Gemini-North telescope has a facility for integral field spectroscopy over the wavelength range 0.4-1.0um. GMOS is converted to this mode by the remote insertion of an integral field unit (IFU) into the beam in place of the masks used for multiobject spectroscopy. With the IFU deployed, integral field spectroscopy is available over a fully-filled contiguous field of 5 x 7 arcsec with a sampling of 0.2 arcsec. A separate field of half the area, but otherwise identical, is also provided to aid background subtraction. The IFU contains 1500 lenslet-coupled fibres and is the largest-format fibre-based IFU yet tested on the sky and the first facility of any type for integral field spectroscopy employed on an 8/10m telescope. We describe the IFU and present results from commissioning.