Normalized to: Muraz, J.
[1]
oai:arXiv.org:1903.02159 [pdf] - 2070434
Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter
directional detector prototype
Tao, Y.;
Beaufort, C.;
Moric, I.;
Tao, C.;
Santos, D.;
Sauzet, N.;
Couturier, C.;
Guillaudin, O.;
Muraz, J. F.;
Naraghi, F.;
Zhou, N.;
Busto, J.
Submitted: 2019-03-05, last modified: 2020-03-26
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred
candidate for Dark Matter. WIMPs should interact with the nuclei of detectors.
If a robust signal is eventually observed in direct detection experiments, the
best signature to confirm its Galactic origin would be the nuclear recoil track
direction. The MIMAC collaboration has developed a low pressure gas detector
providing both the kinetic energy and three-dimensional track reconstruction of
nuclear recoils. In this paper we report the first ever observations of
$^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC detector, in the low
kinetic energy range ($6$-$26$ keV), using specially developed ion beam
facilities. We have measured the recoil track lengths and found significant
differences between our measurements and standard simulations. In order to
understand these differences, we have performed a series of complementary
experiments and simulations to study the impact of the diffusion and eventual
systematics. We show an unexpected dependence of the number of read-out
corresponding to the track on the electric field applied to the $512\
\mathrm{\mu m}$ gap of the Micromegas detector. We have introduced, based on
the flash-ADC observable, corrections in order to reconstruct the physical 3D
track length of the primary electron clouds proposing the physics behind these
corrections. We show that diffusion and space charge effects need to be taken
into account to explain the differences between measurements and standard
simulations. These measurements and simulations may shed a new light on the
high-gain TPC ionization signals in general and particularly at low energy.
[2]
oai:arXiv.org:1902.08960 [pdf] - 1890376
Precision laser-based measurements of the single electron response of
SPCs for the NEWS-G light dark matter search experiment
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Bard, J. -P.;
Brossard, A.;
Chapellier, M.;
Clark, M.;
Crawford, S.;
Corcoran, E. C.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Giroux, G.;
Gorel, P.;
Gros, M.;
Gros, P.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Knights, P.;
Langrock, S.;
Lautridou, P.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Nikolopoulos, K.;
Piquemal, F.;
Piro, M. -C.;
Santos, D.;
Savvidis, G.;
Savvidis, I.;
Fernandez, F. Vazquez de Sola;
Vidal, M.;
Zampaolo, M.
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector
technology employed by the NEWS-G low-mass dark matter search experiment for
their high sensitivity to single electrons from ionization. In this paper, we
report on the first characterization of the single electron response of SPCs
with unprecedented precision, using a UV-laser calibration system. The
experimental approach and analysis methodology are presented along with various
direct applications for the upcoming next phase of the experiment at SNOLAB.
These include the continuous monitoring of the detector response and electron
drift properties during dark matter search runs, as well as the experimental
measurement of the trigger threshold efficiency. We measure a mean ionization
energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$
for 2.8 keV X-rays, and demonstrate the feasibility of performing similar
precision measurements at sub-keV energies for future gas mixtures to be used
for dark matter searches at SNOLAB.
[3]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[4]
oai:arXiv.org:1504.05865 [pdf] - 1579629
First detection of tracks of radon progeny recoils by MIMAC
Riffard, Q.;
Santos, D.;
Bosson, G.;
Bourrion, O.;
Descombes, T.;
Fourel, C.;
Guillaudin, O.;
Muraz, J. -F.;
Colas, P.;
Ferrer-Ribas, E.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Tao, C.;
Lebreton, L.;
Maire, D.
Submitted: 2015-04-22, last modified: 2017-06-20
The MIMAC experiment is a $\mu$-TPC matrix project for directional dark
matter search. Directional detection is a strategy based on the measurement of
the WIMP flux anisotropy due to the solar system motion with respect to the
dark matter halo. The main purpose of MIMAC project is the measurement of the
energy and the direction of nuclear recoils in 3D produced by elastic
scattering of WIMPs. Since June 2012 a bi-chamber prototype is operating at the
Modane underground laboratory. In this paper, we report the first ionization
energy and 3D track observations of nuclear recoils produced by the radon
progeny. This measurement shows the capability of the MIMAC detector and opens
the possibility to explore the low energy recoil directionality signature.
[5]
oai:arXiv.org:1602.01738 [pdf] - 1483260
MIMAC low energy electron-recoil discrimination measured with fast
neutrons
Riffard, Q.;
Santos, D.;
Guillaudin, O.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Descombes, T.;
Muraz, J. -F.;
Lebreton, L.;
Maire, D.;
Colas, P.;
Giomataris, I.;
Busto, J.;
Fouchez, D.;
Brunner, J.;
Tao, C.
Submitted: 2016-02-04, last modified: 2016-07-04
MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter
detector project. Direct dark matter experiments need a high level of
electron/recoil discrimination to search for nuclear recoils produced by
WIMP-nucleus elastic scattering. In this paper, we proposed an original method
for electron event rejection based on a multivariate analysis applied to
experimental data acquired using monochromatic neutron fields. This analysis
shows that a $10^5$ rejection power is reachable for electron/recoil
discrimination. Moreover, the efficiency was estimated by a Monte-Carlo
simulation showing that a 105 electron rejection power is reached with a
$86.49\pm 0.17$\% nuclear recoil efficiency considering the full energy range
and $94.67\pm0.19$\% considering a 5~keV lower threshold.
[6]
oai:arXiv.org:1311.0616 [pdf] - 1180445
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional
detection
Santos, D.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. F.;
Richer, J. P.;
Riffard, Q.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-11-04
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from neutrons, the ultimate background
for dark matter direct detection. This strategy requires both a precise
measurement of the energy down to a few keV and 3D reconstruction of tracks
down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has
developed in the last years an original prototype detector based on the direct
coupling of large pixelized micromegas with a special developed fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The first bi-chamber prototype has been installed at
Modane, underground laboratory in June 2012. The first undergournd background
events, the gain stability and calibration are shown. The first spectrum of
nuclear recoils showing 3D tracks coming from the radon progeny is presented.
[7]
oai:arXiv.org:1306.4173 [pdf] - 681293
Dark Matter directional detection with MIMAC
Riffard, Q.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Lamblin, J.;
Mayet, F.;
Muraz, J. -F.;
Richer, J. -P.;
Santos, D.;
Lebreton, L.;
Maire, D.;
Busto, J.;
Brunner, J.;
Fouchez, D.
Submitted: 2013-06-18
Directional detection is a promising direct Dark Matter (DM) search strategy.
The angular distribution of the nuclear recoil tracks from WIMP events should
present an anisotropy in galactic coordinates. This strategy requires both a
measurement of the recoil energy with a threshold of about 5 keV and 3D recoil
tracks down to few millimeters.
The MIMAC project, based on a \textmu-TPC matrix, with $CF_4$ and $CHF_3$, is
being developed. In June 2012, a bi-chamber prototype was installed at the LSM
(Laboratoire Souterrain de Modane). A preliminary analysis of the first four
months data taking allowed, for the first time, the observation of recoils from
the $\mathrm{^{222}Rn}$ progeny.
[8]
oai:arXiv.org:1304.2255 [pdf] - 1165808
MIMAC: A micro-tpc matrix for dark matter directional detection
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, C.;
Guillaudin, O.;
Lamblin, J.;
Muraz, J. F.;
Mayet, F.;
Richer, J. P.;
Riffard, Q.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Lebreton, L.;
Maire, D.
Submitted: 2013-04-08
The dark matter directional detection opens a new field in cosmology bringing
the possibility to build a map of nuclear recoils that would be able to explore
the galactic dark matter halo giving access to a particle characterization of
such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers)
collaboration has developed in the last years an original prototype detector
based on the direct coupling of large pixelized micromegas with a devoted fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The discovery potential of this search strategy is
discussed and illustrated. In June 2012, the first bi-chamber prototype has
been installed at Modane Underground Laboratory (LSM) and the first underground
background events, the gain stability and calibration are shown.