sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Muleri, Fabio

Normalized to: Muleri, F.

52 article(s) in total. 641 co-authors, from 1 to 38 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1910.10092  [pdf] - 1984093
ESA Voyage 2050 white paper: A Polarized View of the Hot and Violent Universe
Comments: White Paper submitted in response to the ESA Voyage 2050 call, 20 pages + title page + references + list of team members, 10 figures
Submitted: 2019-10-22
Since the birth of X-ray Astronomy, spectacular advances have been seen in the imaging, spectroscopic and timing studies of the hot and violent X-ray Universe, and further leaps forward are expected in the future. On the other hand, polarimetry is very much lagging behind: after the measurements of the Crab Nebula and Scorpius X-1, obtained by OSO-8 in the 70s, no more observations have been performed in the classical X-ray band, even if some interesting results have been obtained in hard X-rays and in soft gamma-rays. The NASA/ASI mission IXPE, scheduled for the launch in 2021, is going to provide for the first time imaging X-ray polarimetry in the 2-8 keV band thanks to its photoelectric polarimeter, coupled with ~25'' angular resolution X-ray mirrors. Its orders of magnitude improvement in sensitivity with respect to the OSO-8 Bragg polarimeter implies scientifically meaningful polarimetric measurements for at least the brightest specimens of most classes of X-ray sources. In 2027, the Chinese-led mission eXTP should also be launched. In addition to timing and spectroscopic instruments, eXTP will have on board photoelectric polarimeters very similar to those of IXPE, but with a total effective area 2-3 times larger. Building on IXPE results, eXTP will increase the number of sources for which significant polarimetric measurements could be obtained. However, further progresses, such as exploring a broader energy range, considering a larger effective area, improving the angular resolution, and performing wide-field polarization measurements, are needed to reach a mature phase for X-ray polarimetry. In the first part of this White Paper we will discuss a few scientific cases in which a next generation X-ray Polarimetry mission can provide significant advances. In the second part, a possible concept for a medium-class Next Generation X-ray Polarimetry (NGXP) mission will be sketched.
[2]  oai:arXiv.org:1903.01619  [pdf] - 1864023
PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector
Comments: Accepted for publication in Experimental Astronomy
Submitted: 2019-03-04
The gas pixel detector (GPD) is designed and developed for high-sensitivity astronomical X-ray polarimetry, which is a new window about to open in a few years. Due to the small mass, low power, and compact geometry of the GPD, we propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and test the technology directly in space. There is no optics but a collimator to constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether (DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat, which was launched into a low Earth Sun-synchronous orbit on October 29, 2018, and is currently under test. More launches with improved designs are planned in 2019. These tests will help increase the technology readiness for future missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better understand the orbital background, and may help constrain the physics with observations of the brightest objects.
[3]  oai:arXiv.org:1812.04020  [pdf] - 1795995
The enhanced X-ray Timing and Polarimetry mission - eXTP
Zhang, ShuangNan; Santangelo, Andrea; Feroci, Marco; Xu, YuPeng; Lu, FangJun; Chen, Yong; Feng, Hua; Zhang, Shu; Brandt, Søren; Hernanz, Margarita; Baldini, Luca; Bozzo, Enrico; Campana, Riccardo; De Rosa, Alessandra; Dong, YongWei; Evangelista, Yuri; Karas, Vladimir; Meidinger, Norbert; Meuris, Aline; Nandra, Kirpal; Pan, Teng; Pareschi, Giovanni; Orleanski, Piotr; Huang, QiuShi; Schanne, Stephane; Sironi, Giorgia; Spiga, Daniele; Svoboda, Jiri; Tagliaferri, Gianpiero; Tenzer, Christoph; Vacchi, Andrea; Zane, Silvia; Walton, Dave; Wang, ZhanShan; Winter, Berend; Wu, Xin; Zand, Jean J. M. in 't; Ahangarianabhari, Mahdi; Ambrosi, Giovanni; Ambrosino, Filippo; Barbera, Marco; Basso, Stefano; Bayer, Jörg; Bellazzini, Ronaldo; Bellutti, Pierluigi; Bertucci, Bruna; Bertuccio, Giuseppe; Borghi, Giacomo; Cao, XueLei; Cadoux, Franck; Campana, Riccardo; Ceraudo, Francesco; Chen, TianXiang; Chen, YuPeng; Chevenez, Jerome; Civitani, Marta; Cui, Wei; Cui, WeiWei; Dauser, Thomas; Del Monte, Ettore; Di Cosimo, Sergio; Diebold, Sebastian; Doroshenko, Victor; Dovciak, Michal; Du, YuanYuan; Ducci, Lorenzo; Fan, QingMei; Favre, Yannick; Fuschino, Fabio; Gálvez, José Luis; Gao, Min; Ge, MingYu; Gevin, Olivier; Grassi, Marco; Gu, QuanYing; Gu, YuDong; Han, DaWei; Hong, Bin; Hu, Wei; Ji, Long; Jia, ShuMei; Jiang, WeiChun; Kennedy, Thomas; Kreykenbohm, Ingo; Kuvvetli, Irfan; Labanti, Claudio; Latronico, Luca; Li, Gang; Li, MaoShun; Li, Xian; Li, Wei; Li, ZhengWei; Limousin, Olivier; Liu, HongWei; Liu, XiaoJing; Lu, Bo; Luo, Tao; Macera, Daniele; Malcovati, Piero; Martindale, Adrian; Michalska, Malgorzata; Meng, Bin; Minuti, Massimo; Morbidini, Alfredo; Muleri, Fabio; Paltani, Stephane; Perinati, Emanuele; Picciotto, Antonino; Piemonte, Claudio; Qu, JinLu; Rachevski, Alexandre; Rashevskaya, Irina; Rodriguez, Jerome; Schanz, Thomas; Shen, ZhengXiang; Sheng, LiZhi; Song, JiangBo; Song, LiMing; Sgro, Carmelo; Sun, Liang; Tan, Ying; Uttley, Phil; Wang, Juan; Wang, LangPing; Wang, YuSa; Watts, Anna L.; Wen, XiangYang; Wilms, Jörn; Xiong, ShaoLin; Yang, JiaWei; Yang, Sheng; Yang, YanJi; Yu, Nian; Zhang, WenDa; Zampa, Gianluigi; Zampa, Nicola; Zdziarski, Andrzej A.; Zhang, AiMei; Zhang, ChengMo; Zhang, Fan; Zhang, Long; Zhang, Tong; Zhang, Yi; Zhang, XiaoLi; Zhang, ZiLiang; Zhao, BaoSheng; Zheng, ShiJie; Zhou, YuPeng; Zorzi, Nicola; Zwart, J. Frans
Comments: Accepted for publication on Sci. China Phys. Mech. Astron. (2019)
Submitted: 2018-12-10
In this paper we present the enhanced X-ray Timing and Polarimetry mission - eXTP. eXTP is a space science mission designed to study fundamental physics under extreme conditions of density, gravity and magnetism. The mission aims at determining the equation of state of matter at supra-nuclear density, measuring effects of QED, and understanding the dynamics of matter in strong-field gravity. In addition to investigating fundamental physics, eXTP will be a very powerful observatory for astrophysics that will provide observations of unprecedented quality on a variety of galactic and extragalactic objects. In particular, its wide field monitoring capabilities will be highly instrumental to detect the electro-magnetic counterparts of gravitational wave sources. The paper provides a detailed description of: (1) the technological and technical aspects, and the expected performance of the instruments of the scientific payload; (2) the elements and functions of the mission, from the spacecraft to the ground segment.
[4]  oai:arXiv.org:1807.11269  [pdf] - 1724303
The Large Area Detector onboard the eXTP mission
Comments: Paper presented at SPIE Space Telescopes and Instrumentation 2018
Submitted: 2018-07-30
The eXTP (enhanced X-ray Timing and Polarimetry) mission is a major project of the Chinese Academy of Sciences (CAS) and China National Space Administration (CNSA) currently performing an extended phase A study and proposed for a launch by 2025 in a low-earth orbit. The eXTP scientific payload envisages a suite of instruments (Spectroscopy Focusing Array, Polarimetry Focusing Array, Large Area Detector and Wide Field Monitor) offering unprecedented simultaneous wide-band X-ray spectral, timing and polarimetry sensitivity. A large European consortium is contributing to the eXTP study and it is expected to provide key hardware elements, including a Large Area Detector (LAD). The LAD instrument for eXTP is based on the design originally proposed for the LOFT mission within the ESA context. The eXTP/LAD envisages a deployed 3.4 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we provide an overview of the LAD instrument design, including new elements with respect to the earlier LOFT configuration.
[5]  oai:arXiv.org:1801.01391  [pdf] - 1613221
Correlation methods for the analysis of X-ray polarimetric signals
Comments:
Submitted: 2018-01-04
X-ray polarimetric measurements are based on studying the distribution of the directions of scattered photons or photoelectrons and on the search of a sinusoidal modulation with a period of {\pi}. We developed two tools for investigating these angular distributions based on the correlations between counts in phase bins separated by fixed phase distances. In one case we use the correlation between data separated by half of the bin number (one period) which is expected to give a linear pattern. In the other case, the scatter plot obtained by shifting by 1/8 of the bin number (1/4 of period) transforms the sinusoid in a circular pattern whose radius is equal to the amplitude of the modulation. For unpolarized radiation these plots are reduced to a random point distribution centred at the mean count level. This new methods provide direct visual and simple statistical tools for evaluating the quality of polarization measurements and for estimating the polarization parameters. Furthermore they are useful for investigating distortions due to systematic effects.
[6]  oai:arXiv.org:1709.03304  [pdf] - 1588186
Predicting the X-ray polarization of type-2 Seyfert galaxies
Comments: 32 pages, 24 figures, accepted for publication in MNRAS
Submitted: 2017-09-11
Infrared, optical and ultraviolet spectropolarimetric observations have proven to be ideal tools for the study of the hidden nuclei of type-2 active galactic nuclei (AGN) and for constraining the composition and morphology of the sub-parsec scale emission components. In this paper, we extend the analysis to the polarization of the X-rays from type-2 AGN. Combining two radiative transfer codes, we performed the first simulations of photons originating in the gravity dominated vicinity of the black hole and scattering in structures all the way out to the parsec-scale torus and polar winds. We demonstrate that, when strong gravity effects are accounted for, the X-ray polarimetric signal of Seyfert-2s carries as much information about the central AGN components as spectropolarimetric observations of Seyfert-1s. The spectropolarimetric measurements can constrain the spin of the central supermassive black hole even in edge-on AGN, the hydrogen column density along the observer's line-of-sight, and the composition of the polar outflows. However, the polarization state of the continuum source is washed out by multiple scattering, and should not be measurable unless the initial polarization is exceptionally strong. Finally, we estimate that modern X-ray polarimeters, either based on the photo-electric effect or on Compton scattering, will require long observational times on the order of a couple of mega-seconds to be able to properly measure the polarization of type-2 AGN.
[7]  oai:arXiv.org:1609.09683  [pdf] - 1489510
Testing multilayer-coated polarizing mirrors for the LAMP soft X-ray telescope
Comments: Preprint version: the fully published paper can be downloaded at http://dx.doi.org/10.1117/12.2185432
Submitted: 2016-09-30
The LAMP (Lightweight Asymmetry and Magnetism Probe) X-ray telescope is a mission concept to measure the polarization of X-ray astronomical sources at 250 eV via imaging mirrors that reflect at incidence angles near the polarization angle, i.e., 45 deg. Hence, it will require the adoption of multilayer coatings with a few nanometers d-spacing in order to enhance the reflectivity. The nickel electroforming technology has already been successfully used to fabricate the high angular resolution imaging mirrors of the X-ray telescopes SAX, XMM-Newton, and Swift/XRT. We are investigating this consolidated technology as a possible technique to manufacture focusing mirrors for LAMP. Although the very good reflectivity performances of this kind of mirrors were already demonstrated in grazing incidence, the reflectivity and the scattering properties have not been tested directly at the unusually large angle of 45 deg. Other possible substrates are represented by thin glass foils or silicon wafers. In this paper we present the results of the X-ray reflectivity campaign performed at the BEAR beamline of Elettra - Sincrotrone Trieste on multilayer coatings of various composition (Cr/C, Co/C), deposited with different sputtering parameters on nickel, silicon, and glass substrates, using polarized X-rays in the spectral range 240 - 290 eV.
[8]  oai:arXiv.org:1607.08823  [pdf] - 2064188
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Zhang, S. N.; Feroci, M.; Santangelo, A.; Dong, Y. W.; Feng, H.; Lu, F. J.; Nandra, K.; Wang, Z. S.; Zhang, S.; Bozzo, E.; Brandt, S.; De Rosa, A.; Gou, L. J.; Hernanz, M.; van der Klis, M.; Li, X. D.; Liu, Y.; Orleanski, P.; Pareschi, G.; Pohl, M.; Poutanen, J.; Qu, J. L.; Schanne, S.; Stella, L.; Uttley, P.; Watts, A.; Xu, R. X.; Yu, W. F.; Zand, J. J. M. in 't; Zane, S.; Alvarez, L.; Amati, L.; Baldini, L.; Bambi, C.; Basso, S.; Bhattacharyya, S.; Bellazzini, R.; Belloni, T.; Bellutti, P.; Bianchi, S.; Brez, A.; Bursa, M.; Burwitz, V.; Budtz-Jorgensen, C.; Caiazzo, I.; Campana, R.; Cao, X. L.; Casella, P.; Chen, C. Y.; Chen, L.; Chen, T. X.; Chen, Y.; Chen, Y.; Chen, Y. P.; Civitani, M.; Zelati, F. Coti; Cui, W.; Cui, W. W.; Dai, Z. G.; Del Monte, E.; De Martino, D.; Di Cosimo, S.; Diebold, S.; Dovciak, M.; Donnarumma, I.; Doroshenko, V.; Esposito, P.; Evangelista, Y.; Favre, Y.; Friedrich, P.; Fuschino, F.; Galvez, J. L.; Gao, Z. L.; Ge, M. Y.; Gevin, O.; Goetz, D.; Han, D. W.; Heyl, J.; Horak, J.; Hu, W.; Huang, F.; Huang, Q. S.; Hudec, R.; Huppenkothen, D.; Israel, G. L.; Ingram, A.; Karas, V.; Karelin, D.; Jenke, P. A.; Ji, L.; Kennedy, T.; Korpela, S.; Kunneriath, D.; Labanti, C.; Li, G.; Li, X.; Li, Z. S.; Liang, E. W.; Limousin, O.; Lin, L.; Ling, Z. X.; Liu, H. B.; Liu, H. W.; Liu, Z.; Lu, B.; Lund, N.; Lai, D.; Luo, B.; Luo, T.; Ma, B.; Mahmoodifar, S.; Marisaldi, M.; Martindale, A.; Meidinger, N.; Men, Y. P.; Michalska, M.; Mignani, R.; Minuti, M.; Motta, S.; Muleri, F.; Neilsen, J.; Orlandini, M.; Pan, A T.; Patruno, A.; Perinati, E.; Picciotto, A.; Piemonte, C.; Pinchera, M.; Rachevski, A.; Rapisarda, M.; Rea, N.; Rossi, E. M. R.; Rubini, A.; Sala, G.; Shu, X. W.; Sgro, C.; Shen, Z. X.; Soffitta, P.; Song, L. M.; Spandre, G.; Stratta, G.; Strohmayer, T. E.; Sun, L.; Svoboda, J.; Tagliaferri, G.; Tenzer, C.; Tong, H.; Taverna, R.; Torok, G.; Turolla, R.; Vacchi, A.; Wang, J.; Wang, J. X.; Walton, D.; Wang, K.; Wang, J. F.; Wang, R. J.; Wang, Y. F.; Weng, S. S.; Wilms, J.; Winter, B.; Wu, X.; Wu, X. F.; Xiong, S. L.; Xu, Y. P.; Xue, Y. Q.; Yan, Z.; Yang, S.; Yang, X.; Yang, Y. J.; Yuan, F.; Yuan, W. M.; Yuan, Y. F.; Zampa, G.; Zampa, N.; Zdziarski, A.; Zhang, C.; Zhang, C. L.; Zhang, L.; Zhang, X.; Zhang, Z.; Zhang, W. D.; Zheng, S. J.; Zhou, P.; Zhou, X. L.
Comments: 16 pages, 16 figures. Oral talk presented at SPIE Astronomical Telescopes and Instrumentation, June 26 to July 1, 2016, Edingurgh, UK
Submitted: 2016-07-29
eXTP is a science mission designed to study the state of matter under extreme conditions of density, gravity and magnetism. Primary targets include isolated and binary neutron stars, strong magnetic field systems like magnetars, and stellar-mass and supermassive black holes. The mission carries a unique and unprecedented suite of state-of-the-art scientific instruments enabling for the first time ever the simultaneous spectral-timing-polarimetry studies of cosmic sources in the energy range from 0.5-30 keV (and beyond). Key elements of the payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV respectively, equipped with Silicon Drift Detectors offering <180 eV spectral resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10 keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV, equipped with imaging gas pixel photoelectric polarimeters; the Wide Field Monitor (WFM) - a set of 3 coded mask wide field units, equipped with position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90 degrees FoV. The eXTP international consortium includes mostly major institutions of the Chinese Academy of Sciences and Universities in China, as well as major institutions in several European countries and the United States. The predecessor of eXTP, the XTP mission concept, has been selected and funded as one of the so-called background missions in the Strategic Priority Space Science Program of the Chinese Academy of Sciences since 2011. The strong European participation has significantly enhanced the scientific capabilities of eXTP. The planned launch date of the mission is earlier than 2025.
[9]  oai:arXiv.org:1509.05595  [pdf] - 1323479
Assembly and Test of the Gas Pixel Detector for X-ray Polarimetry
Comments: accepted for publication in Nuclear Instruments and Methods in Physics Research Section A (NIMA)
Submitted: 2015-09-18
The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is selected as the focal plane detector for the ESA medium-class mission concept X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design, assembly, and preliminary test results of a small GPD for the purpose of gas mixture optimization needed for the phase A study of XIPE. The detector is assembled in house at Tsinghua University following a design by the INFN-Pisa group. The improved detector design results in a good uniformity for the electric field. Filled with pure dimethyl ether (DME) at 0.8 atm, the measured energy resolution is 18% at 6 keV and inversely scales with the square root of the X-ray energy. The measured modulation factor is well consistent with that from simulation, up to ~0.6 above 6 keV. The residual modulation is found to be 0.30% +/- 0.15% at 6 keV for the whole sensitive area, which can be translated into a systematic error of less than 1% for polarization measurement at a confidence level of 99%. The position resolution of the detector is about 80 um in FWHM, consistent with previous studies and sufficient for XIPE requirements.
[10]  oai:arXiv.org:1509.05023  [pdf] - 1282257
Polarization of neutron star surface emission: a systematic analysis
Comments: 13 pages, 9 figures, accepted for publication in MNRAS
Submitted: 2015-09-16
New-generation X-ray polarimeters currently under development promise to open a new window in the study of high-energy astrophysical sources. Among them, neutron stars appear particularly suited for polarization measurements. Radiation from the (cooling) surface of a neutron star is expected to exhibit a large intrinsic polarization degree due to the star strong magnetic field ($\approx 10^{12}-10^{15}$ G), which influences the plasma opacity in the outermost stellar layers. The polarization fraction and polarization angle as measured by an instrument, however, do not necessary coincide with the intrinsic ones derived from models of surface emission. This is due to the effects of quantum electrodynamics in the highly magnetized vacuum around the star (the vacuum polarization) coupled with the rotation of the Stokes parameters in the plane perpendicular to the line of sight induced by the non-uniform magnetic field. Here we revisit the problem and present an efficient method for computing the observed polarization fraction and polarization angle in the case of radiation coming from the entire surface of a neutron star, accounting for both vacuum polarization and geometrical effects due to the extended emitting region. Our approach is fairly general and is illustrated in the case of blackbody emission from a neutron star with either a dipolar or a (globally) twisted magnetic field.
[11]  oai:arXiv.org:1509.04392  [pdf] - 1277254
LAMP: a micro-satellite based soft X-ray polarimeter for astrophysics
Comments:
Submitted: 2015-09-15
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite mission concept dedicated for astronomical X-ray polarimetry and is currently under early phase study. It consists of segmented paraboloidal multilayer mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV X-rays, which will be detected by position sensitive detectors at the focal plane. The primary targets of LAMP include the thermal emission from the surface of pulsars and synchrotron emission produced by relativistic jets in blazars. With the expected sensitivity, it will allow us to detect polarization or place a tight upper limit for about 10 pulsars and 20 blazars. In addition to measuring magnetic structures in these objects, LAMP will also enable us to discover bare quark stars if they exist, whose thermal emission is expected to be zero polarized, while the thermal emission from neutron stars is believed to be highly polarized due to plasma polarization and the quantum electrodynamics (QED) effect. Here we present an overview of the mission concept, its science objectives and simulated observational results.
[12]  oai:arXiv.org:1502.04894  [pdf] - 959578
Reflection nebulae in the Galactic Center: the case for soft X-ray imaging polarimetry
Comments: 7 pages, 3 figures, 2 tables, accepted for publication in A&A
Submitted: 2015-02-17
The origin of irradiation and fluorescence of the 6.4 keV bright giant molecular clouds surrounding Sgr A*, the central supermassive black hole of our Galaxy, remains enigmatic. Testing the theory of a past active period of Sgr A* requires X-ray polarimetry. In this paper, we show how modern imaging polarimeters could revolutionize our understanding of the Galactic Center. Through Monte Carlo modeling, we produce a 4-8 keV polarization map of the Galactic Center, focusing on the polarimetric signature produced by Sgr B1, Sgr B2, G0.11-0.11, Bridge E, Bridge D, Bridge B2, MC2, MC1, Sgr C3, Sgr C2, and Sgr C1. We estimate the resulting polarization, include polarized flux dilution by the diffuse plasma emission detected toward the GC, and simulate the polarization map that modern polarimetric detectors would obtain assuming the performances of a mission prototype. The eleven reflection nebulae investigated in this paper present a variety of polarization signatures, ranging from nearly unpolarized to highly polarized (about 77%) fluxes. A major improvement in our simulation is the addition of a diffuse, unpolarized plasma emission that strongly impacts soft X-ray polarized fluxes. The dilution factor is in the range 50% - 70%, making the observation of the Bridge structure unlikely even in the context of modern polarimetry. The best targets are the Sgr B and Sgr C complexes, and the G0.11-0.11 cloud. An exploratory observation of a few hundred kilo-seconds of the Sgr B complex would allow a significant detection of the polarization and be sufficient to derive hints on the primary source of radiation. A more ambitious program (few Ms) of mapping the giant molecular clouds could then be carried out to probe with great precision the turbulent history of Sgr A*, and place important constraints on the composition and three-dimensional position of the surrounding gas.
[13]  oai:arXiv.org:1408.6526  [pdf] - 864022
The Large Observatory For x-ray Timing
Feroci, M.; Herder, J. W. den; Bozzo, E.; Barret, D.; Brandt, S.; Hernanz, M.; van der Klis, M.; Pohl, M.; Santangelo, A.; Stella, L.; Watts, A.; Wilms, J.; Zane, S.; Ahangarianabhari, M.; Albertus, C.; Alford, M.; Alpar, A.; Altamirano, D.; Alvarez, L.; Amati, L.; Amoros, C.; Andersson, N.; Antonelli, A.; Argan, A.; Artigue, R.; Artigues, B.; Atteia, J. -L.; Azzarello, P.; Bakala, P.; Baldazzi, G.; Balman, S.; Barbera, M.; van Baren, C.; Bhattacharyya, S.; Baykal, A.; Belloni, T.; Bernardini, F.; Bertuccio, G.; Bianchi, S.; Bianchini, A.; Binko, P.; Blay, P.; Bocchino, F.; Bodin, P.; Bombaci, I.; Bidaud, J. -M. Bonnet; Boutloukos, S.; Bradley, L.; Braga, J.; Brown, E.; Bucciantini, N.; Burderi, L.; Burgay, M.; Bursa, M.; Budtz-Jørgensen, C.; Cackett, E.; Cadoux, F. R.; Cais, P.; Caliandro, G. A.; Campana, R.; Campana, S.; Capitanio, F.; Casares, J.; Casella, P.; Castro-Tirado, A. J.; Cavazzuti, E.; Cerda-Duran, P.; Chakrabarty, D.; Château, F.; Chenevez, J.; Coker, J.; Cole, R.; Collura, A.; Cornelisse, R.; Courvoisier, T.; Cros, A.; Cumming, A.; Cusumano, G.; D'Aì, A.; D'Elia, V.; Del Monte, E.; De Luca, A.; De Martino, D.; Dercksen, J. P. C.; De Pasquale, M.; De Rosa, A.; Del Santo, M.; Di Cosimo, S.; Diebold, S.; Di Salvo, T.; Donnarumma, I.; Drago, A.; Durant, M.; Emmanoulopoulos, D.; Erkut, M. H.; Esposito, P.; Evangelista, Y.; Fabian, A.; Falanga, M.; Favre, Y.; Feldman, C.; Ferrari, V.; Ferrigno, C.; Finger, M.; Finger, M. H.; Fraser, G. W.; Frericks, M.; Fuschino, F.; Gabler, M.; Galloway, D. K.; Sanchez, J. L. Galvez; Garcia-Berro, E.; Gendre, B.; Gezari, S.; Giles, A. B.; Gilfanov, M.; Giommi, P.; Giovannini, G.; Giroletti, M.; Gogus, E.; Goldwurm, A.; Goluchová, K.; Götz, D.; Gouiffes, C.; Grassi, M.; Groot, P.; Gschwender, M.; Gualtieri, L.; Guidorzi, C.; Guy, L.; Haas, D.; Haensel, P.; Hailey, M.; Hansen, F.; Hartmann, D. H.; Haswell, C. A.; Hebeler, K.; Heger, A.; Hermsen, W.; Homan, J.; Hornstrup, A.; Hudec, R.; Huovelin, J.; Ingram, A.; Zand, J. J. M. in't; Israel, G.; Iwasawa, K.; Izzo, L.; Jacobs, H. M.; Jetter, F.; Johannsen, T.; Jacobs, H. M.; Jonker, P.; Josè, J.; Kaaret, P.; Kanbach, G.; Karas, V.; Karelin, D.; Kataria, D.; Keek, L.; Kennedy, T.; Klochkov, D.; Kluzniak, W.; Kokkotas, K.; Korpela, S.; Kouveliotou, C.; Kreykenbohm, I.; Kuiper, L. M.; Kuvvetli, I.; Labanti, C.; Lai, D.; Lamb, F. K.; Laubert, P. P.; Lebrun, F.; Lin, D.; Linder, D.; Lodato, G.; Longo, F.; Lund, N.; Maccarone, T. J.; Macera, D.; Maestre, S.; Mahmoodifar, S.; Maier, D.; Malcovati, P.; Mandel, I.; Mangano, V.; Manousakis, A.; Marisaldi, M.; Markowitz, A.; Martindale, A.; Matt, G.; McHardy, I. M.; Melatos, A.; Mendez, M.; Mereghetti, S.; Michalska, M.; Migliari, S.; Mignani, R.; Miller, M. C.; Miller, J. M.; Mineo, T.; Miniutti, G.; Morsink, S.; Motch, C.; Motta, S.; Mouchet, M.; Mouret, G.; Mulačová, J.; Muleri, F.; Muñoz-Darias, T.; Negueruela, I.; Neilsen, J.; Norton, A. J.; Nowak, M.; O'Brien, P.; Olsen, P. E. H.; Orienti, M.; Orio, M.; Orlandini, M.; Orleanski, P.; Osborne, J. P.; Osten, R.; Ozel, F.; Pacciani, L.; Paolillo, M.; Papitto, A.; Paredes, J. M.; Patruno, A.; Paul, B.; Perinati, E.; Pellizzoni, A.; Penacchioni, A. V.; Perez, M. A.; Petracek, V.; Pittori, C.; Pons, J.; Portell, J.; Possenti, A.; Poutanen, J.; Prakash, M.; Provost, P. Le; Psaltis, D.; Rambaud, D.; Ramon, P.; Ramsay, G.; Rapisarda, M.; Rachevski, A.; Rashevskaya, I.; Ray, P. S.; Rea, N.; Reddy, S.; Reig, P.; Aranda, M. Reina; Remillard, R.; Reynolds, C.; Rezzolla, L.; Ribo, M.; de la Rie, R.; Riggio, A.; Rios, A.; Gil, P. Rodríguez-; Rodriguez, J.; Rohlfs, R.; Romano, P.; Rossi, E. M. R.; Rozanska, A.; Rousseau, A.; Ryde, F.; Sabau-Graziati, L.; Sala, G.; Salvaterra, R.; Sanna, A.; Sandberg, J.; Scaringi, S.; Schanne, S.; Schee, J.; Schmid, C.; Shore, S.; Schneider, R.; Schwenk, A.; Schwope, A. D.; Seyler, J. -Y.; Shearer, A.; Smith, A.; Smith, D. M.; Smith, P. J.; Sochora, V.; Soffitta, P.; Soleri, P.; Spencer, A.; Stappers, B.; Steiner, A. W.; Stergioulas, N.; Stratta, G.; Strohmayer, T. E.; Stuchlik, Z.; Suchy, S.; Sulemainov, V.; Takahashi, T.; Tamburini, F.; Tauris, T.; Tenzer, C.; Tolos, L.; Tombesi, F.; Tomsick, J.; Torok, G.; Torrejon, J. M.; Torres, D. F.; Tramacere, A.; Trois, A.; Turolla, R.; Turriziani, S.; Uter, P.; Uttley, P.; Vacchi, A.; Varniere, P.; Vaughan, S.; Vercellone, S.; Vrba, V.; Walton, D.; Watanabe, S.; Wawrzaszek, R.; Webb, N.; Weinberg, N.; Wende, H.; Wheatley, P.; Wijers, R.; Wijnands, R.; Wille, M.; Wilson-Hodge, C. A.; Winter, B.; Wood, K.; Zampa, G.; Zampa, N.; Zampieri, L.; Zdunik, L.; Zdziarski, A.; Zhang, B.; Zwart, F.; Ayre, M.; Boenke, T.; van Damme, C. Corral; Kuulkers, E.; Lumb, D.
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91442T
Submitted: 2014-08-27, last modified: 2014-08-29
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.
[14]  oai:arXiv.org:1408.6548  [pdf] - 1941966
Radiation tests of the Silicon Drift Detectors for LOFT
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 914464
Submitted: 2014-08-27
During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite instrumentation. In particular, we irradiated the detectors with protons (of 0.8 and 11 MeV energy) to study the increment of leakage current and the variation of the charge collection efficiency produced by the displacement damage, and we "bombarded" the detectors with hypervelocity dust grains to measure the effect of the debris impacts. In this paper we describe the measurements and discuss the results in the context of the LOFT mission.
[15]  oai:arXiv.org:1408.6539  [pdf] - 864031
The Large Area Detector of LOFT: the Large Observatory for X-ray Timing
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91442W
Submitted: 2014-08-27
LOFT (Large Observatory for X-ray Timing) is one of the five candidates that were considered by ESA as an M3 mission (with launch in 2022-2024) and has been studied during an extensive assessment phase. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -class instrument operating in the 2-30keV range, which holds the capability to revolutionise studies of variability from X-ray sources on the millisecond time scales. The LAD instrument has now completed the assessment phase but was not down-selected for launch. However, during the assessment, most of the trade-offs have been closed leading to a robust and well documented design that will be re- proposed in future ESA calls. In this talk, we will summarize the characteristics of the LAD design and give an overview of the expectations for the instrument capabilities.
[16]  oai:arXiv.org:1408.6538  [pdf] - 864030
Optimisation of the design for the LOFT Large Area Detector Module
Comments: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 914462
Submitted: 2014-08-27
LOFT (Large Observatory for X-ray Timing) is an X-ray timing observatory that, with four other candidates, was considered by ESA as an M3 mission (with launch in 2022-2024) and has been studied during an extensive assessment phase. Its pointed instrument is the Large Area Detector (LAD), a 10 m 2 -class instrument operating in the 2-30 keV range, which is designed to perform X-ray timing of compact objects with unprecedented resolution down to millisecond time scales. Although LOFT was not downselected for launch, during the assessment most of the trade-offs have been closed, leading to a robust and well documented design that will be reproposed in future ESA calls. The building block of the LAD instrument is the Module, and in this paper we summarize the rationale for the module concept, the characteristics of the module and the trade-offs/optimisations which have led to the current design.
[17]  oai:arXiv.org:1408.0354  [pdf] - 860396
Probing the Galactic center with X-ray polarimetry
Comments: 4 pages, 2 figures, to be published in the Proceedings of the annual meeting of the French Astronomical Society
Submitted: 2014-08-02
The Galactic center (GC) holds the closest-to-Earth supermassive black hole (SMBH), which makes it the best laboratory to study the close environment of extremely massive compact objects. Polarimetry is sensitive to geometry of the source, which makes it a particularly suitable technique to probe the medium surrounding the GC SMBH. The detection of hard X-ray spectra and prominent iron K$\alpha$ fluorescence features coincident with localized gas clouds (e.g. Sgr~B2, Sgr~C) is known for nearly twenty years now and is commonly associated with a past outburst of the SMBH whose radiation is reprocessing onto the so-called "reflection nebulae". Since scattering leads to polarization, the re-emitted signal from the giant molecular clouds in the first 100~pc of the GC is expected to be polarized. X-ray polarization measurement is thus particularly adapted to probe the origin of the diffuse X-ray emission from the GC reflection nebulae and reveal the past activity of the central SMBH. In this research note, we summarize the results from past and current polarimetric simulations in order to show how a future X-ray polarimeter equipped with imaging detectors could improve our understanding of high-energy astrophysics.
[18]  oai:arXiv.org:1407.1710  [pdf] - 1399568
Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors
Comments: 15 pages, 11 figures. Accepted for publication in Journal of Instrumentation (JINST)
Submitted: 2014-07-07
Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.
[19]  oai:arXiv.org:1405.0898  [pdf] - 918776
Prospects of 3D mapping of the Galactic Centre clouds with X-ray polarimetry
Comments: 8 pages, 4 Figures, 4 Tables, accepted for publication in MNRAS
Submitted: 2014-05-05
Despite past panchromatic observations of the innermost part of the Milky Way, the overall structure of the Galactic Centre (GC) remains enigmatic in terms of geometry. In this paper, we aim to show how polarimetry can probe the three-dimensional position of the molecular material in the central ~100 pc of the GC. We investigate a model where the central supermassive black hole Sgr A* is radiatively coupled to a fragmented circumnuclear disc (CND), an elliptical twisted ring representative of the central molecular zone (CMZ), and the two main, bright molecular clouds Sgr B2 and Sgr C. 8 -- 35 keV integrated polarization mapping reveals that Sgr B2 and Sgr C, situated at the two sides of the CMZ, present the highest polarization degrees (66.5 and 47.8 per cent respectively), both associated with a polarization position angle psi = 90deg (normal to the scattering plane). The CND shows a lower polarization degree, 1.0 per cent with psi = -20.5deg, tracing the inclination of the CND with respect to the Galactic plane. The CMZ polarization is spatially variable. We also consider a range of spatial locations for Sgr A* and the reprocessing media, and investigate how the modeled three-dimensional geometry influences the resulting GC polarization. The two reflection nebulae are found to always produce high polarization degrees (>> 10 per cent). We show that a 500 ks observation with a broadband polarimeter could constrain the location and the morphology of the scattering material with respect to the emitting source, revealing the past activity of Sgr A*.
[20]  oai:arXiv.org:1403.7200  [pdf] - 1208656
The imaging properties of the Gas Pixel Detector as a focal plane polarimeter
Comments: Accepted for publication in The Astrophysical Journal Supplement
Submitted: 2014-03-27
X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.
[21]  oai:arXiv.org:1311.2220  [pdf] - 786443
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Comments: Author's accepted manuscript posted to arXiv.org as permitted by Springer's Self-Archiving Policy. The final publication is available at http://rd.springer.com/article/10.1007%2Fs10686-013-9365-y
Submitted: 2013-11-09, last modified: 2014-02-18
The Joint European X-ray Telescope (JET-X) was the core instrument of the Russian Spectrum-X-gamma space observatory. It consisted of two identical soft X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured angular resolution of nearly 15 arcsec. Soon after the payload completion, the mission was cancelled and the two optical flight modules (FM) were brought to the Brera Astronomical Observatory where they had been manufactured. After 16 years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel Detector (GPD) with polarimetric capabilities in the focal plane of the FM2. The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In the first phase of the test campaign, we have re-tested the FM2 at PANTER to have an up-to-date characterization in terms of angular resolution and effective area, while in the second part of the test the GPD has been placed in the focal plane of the FM2. In this paper we report the results of the tests of the sole FM2, using an unpolarized X-ray source, comparing the results with the calibration done in 1996.
[22]  oai:arXiv.org:1312.2497  [pdf] - 1202133
On the operation of X-ray polarimeters with a large field of view
Comments: Accepted for publication in ApJ
Submitted: 2013-12-09
The measurement of the linear polarization is one of the hot topics of High Energy Astrophysics. Gas detectors based on photoelectric effect have paved the way for the design of sensitive instruments and mission proposals based on them have been presented in the last few years in the energy range from about 2 keV to a few tens of keV. As well, a number of polarimeters based on Compton scattering are approved or discussed for launch on-board balloons or space satellites at higher energies. These instruments are typically dedicated to pointed observations with narrow field of view telescopes or collimators, but there are also projects aimed at the polarimetry of bright transient sources, like Soft Gamma Repeaters or the prompt emission of Gamma Ray Bursts. Given the erratic appearance of such events in the sky, these polarimeters have a large field of view to catch a reasonable number of them and, as a result, photons may impinge on the detector off-axis. This changes dramatically the response of the instrument to polarization, regardless if photoabsorption or Compton scattering is involved. Instead of the simple cosine square dependency expected for polarized photons which are incident on-axis, the response is never purely cosinusoidal and a systematic modulation appears also for unpolarized radiation. We investigate the origin of these differences and present an analytic treatment which proves that actually such systematic effects are the natural consequence of how current instruments operate. Our analysis provides the expected response of photoelectric or Compton polarimeters to photons impinging with any inclination and state of polarization.
[23]  oai:arXiv.org:1311.7500  [pdf] - 1201928
Probing magnetars magnetosphere through X-ray polarization measurements
Comments: 12 pages, 8 figures, accepted for publication in MNRAS
Submitted: 2013-11-29
The study of magnetars is of particular relevance since these objects are the only laboratories where the physics in ultra-strong magnetic fields can be directly tested. Until now, spectroscopic and timing measurements at X-ray energies in soft gamma-repeaters (SGRs) and anomalous X-ray pulsar (AXPs) have been the main source of information about the physical properties of a magnetar and of its magnetosphere. Spectral fitting in the ~ 0.5-10 keV range allowed to validate the "twisted magnetosphere" model, probing the structure of the external field and estimating the density and velocity of the magnetospheric currents. Spectroscopy alone, however, may fail in disambiguating the two key parameters governing magnetospheric scattering (the charge velocity and the twist angle) and is quite insensitive to the source geometry. X-ray polarimetry, on the other hand, can provide a quantum leap in the field by adding two extra observables, the linear polarization degree and the polarization angle. Using the bright AXP 1RXS J170849.0-400910 as a template, we show that phase-resolved polarimetric measurements can unambiguously determine the model parameters, even with a small X-ray polarimetry mission carrying modern photoelectric detectors and existing X-ray optics. We also show that polarimetric measurements can pinpoint vacuum polarization effects and thus provide an indirect evidence for ultra-strong magnetic fields.
[24]  oai:arXiv.org:1309.6995  [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo; Barcons, Xavier; Bellazzini, Ronaldo; Braga, João; Costa, Enrico; Fraser, George W.; Gburek, Szymon; Huovelin, Juhani; Matt, Giorgio; Pearce, Mark; Poutanen, Juri; Reglero, Victor; Santangelo, Andrea; Sunyaev, Rashid A.; Tagliaferri, Gianpiero; Weisskopf, Martin; Aloisio, Roberto; Amato, Elena; Attiná, Primo; Axelsson, Magnus; Baldini, Luca; Basso, Stefano; Bianchi, Stefano; Blasi, Pasquale; Bregeon, Johan; Brez, Alessandro; Bucciantini, Niccoló; Burderi, Luciano; Burwitz, Vadim; Casella, Piergiorgio; Churazov, Eugene; Civitani, Marta; Covino, Stefano; da Silva, Rui Miguel Curado; Cusumano, Giancarlo; Dadina, Mauro; D'Amico, Flavio; De Rosa, Alessandra; Di Cosimo, Sergio; Di Persio, Giuseppe; Di Salvo, Tiziana; Dovciak, Michal; Elsner, Ronald; Eyles, Chris J.; Fabian, Andrew C.; Fabiani, Sergio; Feng, Hua; Giarrusso, Salvatore; Goosmann, René W.; Grandi, Paola; Grosso, Nicolas; Israel, Gianluca; Jackson, Miranda; Kaaret, Philip; Karas, Vladimir; Kuss, Michael; Lai, Dong; La Rosa, Giovanni; Larsson, Josefin; Larsson, Stefan; Latronico, Luca; Maggio, Antonio; Maia, Jorge; Marin, Frédéric; Massai, Marco Maria; Mineo, Teresa; Minuti, Massimo; Moretti, Elena; Muleri, Fabio; O'Dell, Stephen L.; Pareschi, Giovanni; Peres, Giovanni; Pesce, Melissa; Petrucci, Pierre-Olivier; Pinchera, Michele; Porquet, Delphine; Ramsey, Brian; Rea, Nanda; Reale, Fabio; Rodrigo, Juana Maria; Różańska, Agata; Rubini, Alda; Rudawy, Pawel; Ryde, Felix; Salvati, Marco; Júnior, Valdivino Alexandre de Santiago; Sazonov, Sergey; Sgró, Carmelo; Silver, Eric; Spandre, Gloria; Spiga, Daniele; Stella, Luigi; Tamagawa, Toru; Tamborra, Francesco; Tavecchio, Fabrizio; Dias, Teresa Teixeira; van Adelsberg, Matthew; Wu, Kinwah; Zane, Silvia
Comments: 49 pages, 14 figures, 6 tables. Paper published in Experimental Astronomy http://link.springer.com/journal/10686
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).
[25]  oai:arXiv.org:1309.1691  [pdf] - 716503
Modelling the X-ray polarimetric signatures of complex geometry: the case study of the "changing look" AGN NGC 1365
Comments: 6 pages, 4 figures, accepted for publication in the Monthly Notices of the Royal Astronomical Society
Submitted: 2013-09-06
"Changing look" Active Galactic Nuclei (AGN) are a subset of Seyfert galaxies characterized by rapid transitions between Compton-thin and Compton-thick regimes. In their Compton-thin state, the central engine is less obscured, hence spectroscopy or timing observations can probe their innermost structures. However, it is not clear if the observed emission features and the Compton hump are associated with relativistic reflection onto the accretion disc, or complex absorption by distant, absorbing gas clouds passing by the observer's line-of-sight. Here, we investigate these two scenarios under the scope of X-ray polarimetry, providing the first polarisation predictions for an archetypal "changing look" AGN: NGC 1365. We explore the resulting polarisation emerging from lamp-post emission and scattering off an accretion disc in the immediate vicinity of a supermassive black hole. The computed polarisation signatures are compared to the results of an absorption-dominated model, where high column density gas partially covers the central source. While the shape of the polarisation spectrum is similar, the two models differ in net polarisation percentage, with the relativistic reflection scenario producing significantly stronger polarisation. Additionally, the variation of the polarisation position angle is distinctly different between both scenarios: the reflection-dominated model produces smooth rotations of the polarisation angle with photon energy whereas circumnuclear absorption causes an orthogonal switch of the polarisation angle between the soft and the hard X-ray bands. By comparing the predicted polarisation of NGC 1365 to the detectability levels of X-ray polarimetry mission concepts proposed in the past, we demonstrate that with a large, soft X-ray observatory or a medium-sized mission equipped with a hard (6 - 35 keV) polarimeter, the correct interpretation would be unambiguous.
[26]  oai:arXiv.org:1301.1161  [pdf] - 610925
Characterization of scatterers for an active focal plane Compton polarimeter
Comments: Accepted in press on Astroparticle Physics, 2013
Submitted: 2013-01-07
In this work we present an active Compton scattering polarimeter as a focal plane instrument able to extend the X-ray polarimetry towards hard X-rays. Other authors have already studied various instrument design by means of Monte Carlo simulations, in this work we will show for the first time the experimental measurements of "tagging efficiency" aimed to evaluate the polarimeter sensitivity as a function of energy. We performed a characterization of different scattering materials by measuring the tagging efficiency that was used as an input to the Monte Carlo simulation. Then we calculated the sensitivity to polarization of a design based on the laboratory set-up. Despite the geometry tested is not optimized for a realistic focal plane instrument, we demonstrated the feasibility of polarimetry with a low energy threshold of 20 keV. Moreover we evaluated a Minimum Detectable Polarization of 10% for a 10 mCrab source in 100 ks between 20 and 80 keV in the focal plane of one multilayer optics module of NuSTAR. The configuration used consisted of a doped p-terphenyl scatterer 3 cm long and 0.7 cm of diameter coupled with a 0.2 cm thick LaBr3 absorber.
[27]  oai:arXiv.org:1209.1497  [pdf] - 1151206
LOFT: the Large Observatory For X-ray Timing
Feroci, M.; Herder, J. W. den; Bozzo, E.; Barret, D.; Brandt, S.; Hernanz, M.; van der Klis, M.; Pohl, M.; Santangelo, A.; Stella, L.; Watts, A.; Wilms, J.; Zane, S.; Ahangarianabhari, M.; Alpar, A.; Altamirano, D.; Alvarez, L.; Amati, L.; Amoros, C.; Andersson, N.; Antonelli, A.; Argan, A.; Artigue, R.; Azzarello, P.; Baldazzi, G.; Balman, S.; Barbera, M.; Belloni, T.; Bertuccio, G.; Bianchi, S.; Bianchini, A.; Bodin, P.; Bidaud, J. -M. Bonnet; Boutloukos, S.; Braga, J.; Brown, E.; Bucciantini, N.; Burderi, L.; Bursa, M.; Budtz-Jørgensen, C.; Cackett, E.; Cadoux, F. R.; Cais, P.; Caliandro, G. A.; Campana, R.; Campana, S.; Casella, P.; Chakrabarty, D.; Chenevez, J.; Coker, J.; Cole, R.; Collura, A.; Courvoisier, T.; Cros, A.; Cumming, A.; Cusumano, G.; D'Aì, A.; D'Elia, V.; Del Monte, E.; De Martino, D.; De Rosa, A.; Di Cosimo, S.; Diebold, S.; Di Salvo, T.; Donnarumma, I.; Drago, A.; Durant, M.; Emmanoulopoulos, D.; Evangelista, Y.; Fabian, A.; Falanga, M.; Favre, Y.; Feldman, C.; Ferrigno, C.; Finger, M. H.; Fraser, G. W.; Fuschino, F.; Galloway, D. K.; Sanchez, J. L. Galvez; Garcia-Berro, E.; Gendre, B.; Gezari, S.; Giles, A. B.; Gilfanov, M.; Giommi, P.; Giovannini, G.; Giroletti, M.; Goldwurm, A.; Götz, D.; Gouiffes, C.; Grassi, M.; Guidorzi, P. Groot C.; Haas, D.; Hansen, F.; Hartmann, D. H.; Haswe, C. A.; Heger, A.; Homan, J.; Hornstrup, A.; Hudec, R.; Huovelin, J.; Ingram, A.; Zand, J. J. M. in't; Isern, J.; Israe, G.; Izzo, L.; Jonker, P.; Kaaret, P.; Karas, V.; Karelin, D.; Kataria, D.; Keek, L.; Kennedy, T.; Klochkov, D.; Kluzniak, W.; Kokkotas, K.; Korpela, S.; Kouveliotou, C.; Kreykenbohm, I.; Kuiper, L. M.; Kuvvetli, I.; Labanti, C.; Lai, D.; Lamb, F. K.; Lebrun, F.; Lin, D.; Linder, D.; Lodato, G.; Longo, F.; Lund, N.; Maccarone, T. J.; Macera, D.; Maier, D.; Malcovati, P.; Mangano, V.; Manousakis, A.; Marisaldi, M.; Markowitz, A.; Martindale, A.; Matt, G.; McHardy, I. M.; Melatos, A.; Mendez, M.; Migliari, S.; Mignani, R.; Miller, M. C.; Miller, J. M.; Mineo, T.; Miniutti, G.; Morsink, S.; Motch, C.; Motta, S.; Mouchet, M.; Muleri, F.; Norton, A. J.; Nowak, M.; O'Brien, P.; Orienti, M.; Orio, M.; Orlandini, M.; Orleanski, P.; Osborne, J. P.; Osten, R.; Ozel, F.; Pacciani, L.; Papitto, A.; Paul, B.; Perinati, E.; Petracek, V.; Portell, J.; Poutanen, J.; Psaltis, D.; Rambaud, D.; Ramsay, G.; Rapisarda, M.; Rachevski, A.; Ray, P. S.; Rea, N.; Reddy, S.; Reig, P.; Aranda, M. Reina; Remillard, R.; Reynolds, C.; Rodríguez-Gil, P.; Rodriguez, J.; Romano, P.; Rossi, E. M. R.; Ryde, F.; Sabau-Graziati, L.; Sala, G.; Salvaterra, R.; Sanna, A.; Schanne, S.; Schee, J.; Schmid, C.; Schwenk, A.; Schwope, A. D.; Seyler, J. -Y.; Shearer, A.; Smith, A.; Smith, D. M.; Smith, P. J.; Sochora, V.; Soffitta, P.; Soleri, P.; Stappers, B.; Stelzer, B.; Stergioulas, N.; Stratta, G.; Strohmayer, T. E.; Stuchlik, Z.; Suchy, S.; Sulemainov, V.; Takahashi, T.; Tamburini, F.; Tenzer, C.; Tolos, L.; Torok, G.; Torrejon, J. M.; Torres, D. F.; Tramacere, A.; Trois, A.; Turriziani, S.; Uter, P.; Uttley, P.; Vacchi, A.; Varniere, P.; Vaughan, S.; Vercellone, S.; Vrba, V.; Walton, D.; Watanabe, S.; Wawrzaszek, R.; Webb, N.; Weinberg, N.; Wende, H.; Wheatley, P.; Wijers, R.; Wijnands, R.; Wille, M.; Wilson-Hodge, C. A.; Winter, B.; Wood, K.; Zampa, G.; Zampa, N.; Zampieri, L.; Zdziarski, A.; Zhang, B.
Comments: Proceedings of SPIE, Vol. 8443, Paper No. 8443-85, 2012
Submitted: 2012-09-07
The LOFT mission concept is one of four candidates selected by ESA for the M3 launch opportunity as Medium Size missions of the Cosmic Vision programme. The launch window is currently planned for between 2022 and 2024. LOFT is designed to exploit the diagnostics of rapid X-ray flux and spectral variability that directly probe the motion of matter down to distances very close to black holes and neutron stars, as well as the physical state of ultra-dense matter. These primary science goals will be addressed by a payload composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a collimated (<1 degree field of view) experiment operating in the energy range 2-50 keV, with a 10 m^2 peak effective area and an energy resolution of 260 eV at 6 keV. The WFM will operate in the same energy range as the LAD, enabling simultaneous monitoring of a few-steradian wide field of view, with an angular resolution of <5 arcmin. The LAD and WFM experiments will allow us to investigate variability from submillisecond QPO's to year-long transient outbursts. In this paper we report the current status of the project.
[28]  oai:arXiv.org:1209.1501  [pdf] - 1151210
Simulations of the X-ray imaging capabilities of the Silicon Drift Detectors (SDD) for the LOFT Wide Field Monitor
Comments: Proceedings of SPIE, Vol. 8443, Paper No. 8443-210, 2012
Submitted: 2012-09-07
The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionize the study of compact objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. The Large Area Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask Wide Field Monitor, in charge of monitoring a large fraction of the sky potentially accessible to the LAD, to provide the history and context for the sources observed by LAD and to trigger its observations on their most interesting and extreme states. In this paper we present detailed simulations of the imaging capabilities of the Silicon Drift Detectors developed for the LOFT Wide Field Monitor detection plane. The simulations explore a large parameter space for both the detector design and the environmental conditions, allowing us to optimize the detector characteristics and demonstrating the X-ray imaging performance of the large-area SDDs in the 2-50 keV energy band.
[29]  oai:arXiv.org:1209.1498  [pdf] - 1151207
A Large Area Detector proposed for the Large Observatory for X-ray Timing (LOFT)
Comments: Proceedings of SPIE, Vo. 8443, Paper No. 8443-87
Submitted: 2012-09-07
The Large Observatory for X-ray Timing (LOFT) is one of the four candidate ESA M3 missions considered for launch in the 2022 time-frame. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. The LOFT scientific payload is composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a 10 m2-class pointed instrument with 20 times the collecting area of the best past timing missions (such as RXTE) over the 2-30 keV range, which holds the capability to revolutionize studies of X-ray variability down to the millisecond time scales. Its ground-breaking characteristic is a low mass per unit surface, enabling an effective area of ~10 m^2 (@10 keV) at a reasonable weight. The development of such large but light experiment, with low mass and power per unit area, is now made possible by the recent advancements in the field of large-area silicon detectors - able to time tag an X-ray photon with an accuracy <10 {\mu}s and an energy resolution of ~260 eV at 6 keV - and capillary-plate X-ray collimators. In this paper, we will summarize the characteristics of the LAD instrument and give an overview of its capabilities.
[30]  oai:arXiv.org:1208.6330  [pdf] - 1151008
Measurement of the position resolution of the Gas Pixel Detector
Comments: Submitted to Nuclear Instruments and Methods in Physics Research Section A; 15 figures, 3 tables
Submitted: 2012-08-30
The Gas Pixel Detector was designed and built as a focal plane instrument for X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray astronomy. It promises to perform detailed and sensitive measurements resolving extended sources and detecting polarization in faint sources in crowded fields at the focus of telescopes of good angular resolution. Its polarimetric and spectral capability were already studied in earlier works. Here we investigate for the first time, with both laboratory measurements and Monte Carlo simulations, its imaging properties to confirm its unique capability to carry out imaging spectral-polarimetry in future X-ray missions.
[31]  oai:arXiv.org:1208.3314  [pdf] - 1150721
X-ray polarimetry as a new tool to discriminate reflection from absorption scenarios -- Predictions for MCG-6-30-15
Comments: Accepted for publication in MNRAS 5 pages, 3 figures
Submitted: 2012-08-16
We present modelling of X-ray polarisation spectra emerging from the two competing scenarios that are proposed to explain the broad Fe K{\alpha} line in the Seyfert 1 galaxy MCG-6-30-15. The polarisation signature of complex absorption is studied for a partial covering scenario using a clumpy wind and compared to a reflection model based on the lamp-post geometry. The shape of the polarisation percentage and angle as a function of photon energy are found to be distinctly different between the reflection and the absorption case. Relativistic reflection produces significantly stronger polarisation in the 1-10 keV energy band than absorption. The spectrum of the polarisation angle adds additional constraints: in the absorption case it shows a constant shape, whereas the relativistic reflection scenario typically leads to a smooth rotation of the polarisation angle with photon energy. Based on this work, we conclude that a soft X-ray polarimeter on-board a small X-ray satellite may already discriminate between the absorption and the reflection scenario. A promising opportunity may arise with the X-ray Imaging Polarimetry Explorer (XIPE) mission, which has been proposed to ESA in response to a small-size (S-class) mission call due for launch in 2017.
[32]  oai:arXiv.org:1204.0681  [pdf] - 1117736
Sensitivity of stacked imaging detectors to hard X-ray polarization
Comments: 14 pages, 11 figures. Accepted for publication in ApJ
Submitted: 2012-04-03
The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions dedicated to spectroscopy and imaging at energies >10 keV, e.g. Astro-H and NuSTAR. Nevertheless, our understanding of the hard X-ray sky would greatly benefit from carrying out contemporaneous polarimetric measurements, because the study of hard spectral tails and of polarized emission often are two complementary diagnostics of the same non-thermal and acceleration processes. At energies above a few tens of keV, the preferred technique to detect polarization involves the determination of photon directions after a Compton scattering. Many authors have asserted that stacked detectors with imaging capabilities can be exploited for this purpose. If it is possible to discriminate those events which initially interact in the first detector by Compton scattering and are subsequently absorbed by the second layer, the direction of scattering is singled out from the hit pixels in the two detectors. In this paper we give the first detailed discussion of the sensitivity of such a generic design to the X-ray polarization. The efficiency and the modulation factor are calculated analytically from the geometry of the instruments and then compared with the performance as derived by means of Geant4 Monte Carlo simulations.
[33]  oai:arXiv.org:1111.6391  [pdf] - 444318
The gas pixel detector as a solar X-ray polarimeter and imager
Comments: J. Adv. Space Res. (2011)
Submitted: 2011-11-28
The Sun is the nearest astrophysical source with a very intense emission in the X-ray band. The study of energetic events, such as solar flares, can help us to understand the behaviour of the magnetic field of our star. There are in the literature numerous studies published about polarization predictions, for a wide range of solar flares models involving the emission from thermal and/or non-thermal processes, but observations in the X-ray band have never been exhaustive. The gas pixel detector (GPD) was designed to achieve X-ray polarimetric measurements as well as X-ray images for far astrophysical sources. Here we present the possibility to employ this instrument for the observation of our Sun in the X-ray band.
[34]  oai:arXiv.org:1105.0637  [pdf] - 353860
POLARIX: a pathfinder mission of X-ray polarimetry
Comments: 42 pages, 28 figures
Submitted: 2011-05-03
Since the birth of X-ray astronomy, spectral, spatial and timing observation improved dramatically, procuring a wealth of information on the majority of the classes of the celestial sources. Polarimetry, instead, remained basically unprobed. X-ray polarimetry promises to provide additional information procuring two new observable quantities, the degree and the angle of polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits the polarimetric response of a Gas Pixel Detector, combined with position sensitivity, that, at the focus of a telescope, results in a huge increase of sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics which are the heritage of JET-X mission. POLARIX will measure time resolved X-ray polarization with an angular resolution of about 20 arcsec in a field of view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6 keV. The Minimum Detectable Polarization is 12 % for a source having a flux of 1 mCrab and 10^5 s of observing time. The satellite will be placed in an equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry down-link station will be Malindi. The pointing of POLARIX satellite will be gyroless and it will perform a double pointing during the earth occultation of one source, so maximizing the scientific return. POLARIX data are for 75 % open to the community while 25 % + SVP (Science Verification Phase, 1 month of operation) is dedicated to a core program activity open to the contribution of associated scientists. The planned duration of the mission is one year plus three months of commissioning and SVP, suitable to perform most of the basic science within the reach of this instrument.
[35]  oai:arXiv.org:1102.4247  [pdf] - 1052233
Light bending scenario for accreting black holes in X-ray polarimetry
Comments: 17 pages, 14 figures, accepted in ApJ
Submitted: 2011-02-21
We discuss a model of an X-ray illuminating source above an accretion disk of a rotating black hole. Within the so called lamp-post scheme we compute the expected (observed) polarization properties of the radiation reaching an observer. We explore the dependencies on model parameters, employing Monte Carlo radiation transfer computations of the X-ray reflection on the accretion disk and taking general relativity effects into account. In particular, we discuss the role of the black hole spin, of the observer viewing angle, and of the primary X-ray source distance from the black hole. We give several examples of the resulting polarization degree for two types of exemplary objects - active galactic nuclei and Galactic black holes. In order to assess potential observability of the polarization features, we assume the sensitivity of the proposed New Hard X-ray Mission (NHXM). We examine the energy range from several keV to ~50 keV, so the iron-line complex and the Compton hump are included in our model spectra. We find the resultant polarization degree to increase at the higher end of the studied energy band, i.e. at >~20 keV. Thus, the best results for polarimetry of reflection spectra should be achieved at the Compton hump energy region. We also obtain higher polarization degree for large spin values of the black hole, small heights of the primary source, and low inclination angles of the observer.
[36]  oai:arXiv.org:1008.1009  [pdf] - 1034126
LOFT - a Large Observatory For x-ray Timing
Comments: 13 pages, 8 figures, 1 table, Proceedings of SPIE Vol. 7732, Paper No. 7732-66, 2010
Submitted: 2010-08-05
The high time resolution observations of the X-ray sky hold the key to a number of diagnostics of fundamental physics, some of which are unaccessible to other types of investigations, such as those based on imaging and spectroscopy. Revealing strong gravitational field effects, measuring the mass and spin of black holes and the equation of state of ultradense matter are among the goals of such observations. At present prospects for future, non-focused X-ray timing experiments following the exciting age of RXTE/PCA are uncertain. Technological limitations are unavoidably faced in the conception and development of experiments with effective area of several square meters, as needed in order to meet the scientific requirements. We are developing large-area monolithic Silicon Drift Detectors offering high time and energy resolution at room temperature, which require modest resources and operation complexity (e.g., read-out) per unit area. Based on the properties of the detector and read-out electronics that we measured in the lab, we developed a realistic concept for a very large effective area mission devoted to X-ray timing in the 2-30 keV energy range. We show that effective areas in the range of 10-15 square meters are within reach, by using a conventional spacecraft platform and launcher of the small-medium class.
[37]  oai:arXiv.org:1004.4766  [pdf] - 155228
X-ray Polarimetry: a new window on the high energy sky
Comments: Accepted for publication by NIMA. Proceeding of the 1st International Conference on "Frontiers in Diagnostic Technologies", November 25-27 2009, Frascati (Italy). 11 pages, 4 figures, 1 table.
Submitted: 2010-04-27
Polarimetry is widely considered a powerful observational technique in X-ray astronomy, useful to enhance our understanding of the emission mechanisms, geometry and magnetic field arrangement of many compact objects. However, the lack of suitable sensitive instrumentation in the X-ray energy band has been the limiting factor for its development in the last three decades. Up to now, polarization measurements have been made exclusively with Bragg diffraction at 45 degrees or Compton scattering at 90 degrees and the only unambiguous detection of X-ray polarization has been obtained for one of the brightest object in the X-ray sky, the Crab Nebula. Only recently, with the development of a new class of high sensitivity imaging detectors, the possibility to exploit the photoemission process to measure the photon polarization has become a reality. We will report on the performance of an imaging X-ray polarimeter based on photoelectric effect. The device derives the polarization information from the track of the photoelectrons imaged by a finely subdivided Gas Pixel Detector. It has a great sensitivity even with telescopes of modest area and can perform simultaneously good imaging, moderate spectroscopy and high rate timing. Being truly 2D it is non-dispersive and does not require any rotation. This device is included in the scientific payload of many proposals of satellite mission which have the potential to unveil polarimetry also in X-rays in a few years.
[38]  oai:arXiv.org:1003.6009  [pdf] - 1026036
Spectral and polarimetric characterization of the Gas Pixel Detector filled with dimethyl ether
Comments: 20 pages, 11 figures, 5 tables. Accepted for publication by NIMA
Submitted: 2010-03-31
The Gas Pixel Detector belongs to the very limited class of gas detectors optimized for the measurement of X-ray polarization in the emission of astrophysical sources. The choice of the mixture in which X-ray photons are absorbed and photoelectrons propagate, deeply affects both the energy range of the instrument and its performance in terms of gain, track dimension and ultimately, polarimetric sensitivity. Here we present the characterization of the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME) at 0.79 atm, selected among other mixtures for the very low diffusion coefficient. Almost completely polarized and monochromatic photons were produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg diffraction at nearly 45 degrees. For the first time ever, we measured the modulation factor and the spectral capabilities of the instrument at energies as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV. These measurements cover almost completely the energy range of the instrument and allows to compare the sensitivity achieved with that of the standard mixture, composed of helium and DME.
[39]  oai:arXiv.org:0911.5698  [pdf] - 902584
X-ray polarimetry in Astrophysics with the Gas Pixel Detector
Comments: Proceeding of MPGD2009 Conference, June 12-15, 2009 Kolympari, Crete, Greece; 10 pages, 6 figures and 1 table
Submitted: 2009-11-30
The Gas Pixel Detector, recently developed and continuously improved by Pisa INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced within a low Z gas by photoelectrons of few keV. By reconstructing the impact point and the original direction of the photoelectrons, the GPD can measure the linear polarization of X-rays, while preserving the information on the absorption point, the energy and the time of individual photons. Applied to X-ray Astrophysics, in the focus of grazing incidence telescopes, it can perform angular resolved polarimetry with a huge improvement of sensitivity, when compared with the conventional techniques of Bragg diffraction at 45 degrees and Compton scattering around 90 degrees. This configuration is the basis of POLARIX and HXMT, two pathfinder missions, and is included in the baseline design of IXO, the very large X-ray telescope under study by NASA, ESA and JAXA.
[40]  oai:arXiv.org:0911.5099  [pdf] - 31065
Angular Resolution of a Photoelectric Polarimeter in the Focus of an Optical System
Comments: Proceedings of "The coming of age of x-ray polarimetry" Conference, Rome, April 27th-30th, 2009
Submitted: 2009-11-26
The INFN and INAF Italian research institutes developed a space-borne X-Ray polarimetry experiment based on a X-Ray telescope, focussing the radiation on a Gas Pixel Detector (GPD). The instrument obtains the polarization angle of the absorbed photons from the direction of emission of the photoelectrons as visualized in the GPD. Here we will show how we compute the angular resolution of such an instrument.
[41]  oai:arXiv.org:0810.2700  [pdf] - 17470
XPOL: a photoelectric polarimeter onboard XEUS
Comments: 10 pages, 6 figures
Submitted: 2008-10-15
The XEUS mission incorporates two satellites: the Mirror Spacecraft with 5 m2 of collecting area at 1 keV and 2 m2 at 7 keV, and an imaging resolution of 5" HEW and the Payload Spacecraft which carries the focal plane instrumentation. XEUS was submitted to ESA Cosmic Vision and was selected for an advanced study as a large mission. The baseline design includes XPOL, a polarimeter based on the photoelectric effect, that takes advantage of the large effective area which permits the study of the faint sources and of the long focal length, resulting in a very good spatial resolution, which allows the study of spatial features in extended sources. We show how, with XEUS, Polarimetry becomes an efficient tool at disposition of the Astronomical community.
[42]  oai:arXiv.org:0810.2693  [pdf] - 17468
The Gas Pixel Detector as an X-ray photoelectric polarimeter with a large field of view
Comments: 11 pages, 8 figures
Submitted: 2008-10-15
The Gas Pixel Detector (GPD) is a new generation device which, thanks to its 50 um pixels, is capable of imaging the photoelectrons tracks produced by photoelectric absorption in a gas. Since the direction of emission of the photoelectrons is strongly correlated with the direction of polarization of the absorbed photons, this device has been proposed as a polarimeter for the study of astrophysical sources, with a sensitivity far higher than the instruments flown to date. The GPD has been always regarded as a focal plane instrument and then it has been proposed to be included on the next generation space-borne missions together with a grazing incidence optics. Instead in this paper we explore the feasibility of a new kind of application of the GPD and of the photoelectric polarimeters in general, i.e. an instrument with a large field of view. By means of an analytical treatment and measurements, we verify if it is possible to preserve the sensitivity to the polarization for inclined beams, opening the way for the measurement of X-ray polarization for transient astrophysical sources. While severe systematic effects arise for inclination greater than about 20 degrees, methods and algorithms to control them are discussed.
[43]  oai:arXiv.org:0810.2684  [pdf] - 17465
A versatile facility for the calibration of X-ray polarimeters with polarized and unpolarized controlled beams
Comments: 12 pages, 11 figures
Submitted: 2008-10-15
We devised and built a versatile facility for the calibration of the next generation X-ray polarimeters with unpolarized and polarized radiation. The former is produced at 5.9 keV by means of a Fe55 radioactive source or by X-ray tubes, while the latter is obtained by Bragg diffraction at nearly 45 degrees. Crystals tuned with the emission lines of X-ray tubes with molybdenum, rhodium, calcium and titanium anodes are employed for the efficient production of highly polarized photons at 2.29, 2.69, 3.69 and 4.51 keV respectively. Moreover the continuum emission is exploited for the production of polarized photons at 1.65 keV and 2.04 keV and at energies corresponding to the higher orders of diffraction. The photons are collimated by means of interchangeable capillary plates and diaphragms, allowing a trade-off between collimation and high fluxes. The direction of the beam is accurately arranged by means of high precision motorized stages, controlled via computer so that long and automatic measurements can be done. Selecting the direction of polarization and the incidence point we can map the response of imaging devices to both polarized and unpolarized radiation. Changing the inclination of the beam we can study the systematic effects due to the focusing of grazing incidence optics and the feasibility of instruments with large field of view.
[44]  oai:arXiv.org:0810.2708  [pdf] - 17472
X-ray polarimetry on-board HXMT
Comments: 10 pages, 7 figures
Submitted: 2008-10-15
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray Photoelectric Polarimeter) in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources, the proposed instrument can represent a breakthrough in X-ray Polarimetry.
[45]  oai:arXiv.org:0809.0418  [pdf] - 15897
Thermal disc emission from a rotating black hole: X-ray polarization signatures
Comments: 8 pages, 7 figures, accepted by MNRAS
Submitted: 2008-09-02
Thermal emission from the accretion disc around a black hole can be polarized, due to Thomson scattering in a disc atmosphere. In Newtonian space, the polarization angle must be either parallel or perpendicular to the projection of the disc axis on the sky. As first pointed out by Stark and Connors in 1977, General Relativity effects strongly modify the polarization properties of the thermal radiation as observed at infinity. Among these effects, the rotation of the polarization angle with energy is particularly useful as a diagnostic tool. In this paper, we extend the Stark and Connors calculations by including the spectral hardening factor, several values of the optical depth of the scattering atmosphere and rendering the results to the expected performances of planned X-ray polarimeters. In particular, to assess the perspectives for the next generation of X-ray polarimeters, we consider the expected sensitivity of the detectors onboard the planned POLARIX and IXO missions. We assume the two cases of a Schwarzschild and an extreme Kerr black hole with a standard thin disc and a scattering atmosphere. We compute the expected polarization degree and the angle as functions of the energy as they could be measured for different inclinations of the observer, optical thickness of the atmosphere and different values of the black hole spin. We assume the thermal emission dominates the X-ray band. Using the flux level of the microquasar GRS 1915+105 in the thermal state, we calculate the observed polarization.
[46]  oai:arXiv.org:0709.4623  [pdf] - 5478
Low energy polarization sensitivity of the Gas Pixel Detector
Comments: 15 pages, 12 figures. Accepted for publication in NIMA
Submitted: 2007-09-28
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances. In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly 45 degrees. The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.
[47]  oai:arXiv.org:0709.3992  [pdf] - 5336
An X-ray Polarimeter for HXMT Mission
Comments: 10 pages, 9 figures
Submitted: 2007-09-25
The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources the proposed instrument can represent a breakthrough in X-ray Polarimetry.
[48]  oai:arXiv.org:0709.3978  [pdf] - 5330
A very compact polarizer for an X-ray polarimeter calibration
Comments: 12 pages, 22 figures
Submitted: 2007-09-25
We devised and built a light, compact and transportable X-ray polarized source based on the Bragg diffraction at nearly 45 degrees. The source is composed by a crystal coupled to a small power X-ray tube. The angles of incidence are selected by means of two orthogonal capillary plates which, due to the small diameter holes (10 um) allow good collimation with limited sizes. All the orders of diffraction defined by the crystal lattice spacing are polarized up to the maximum order limited by the X-ray tube voltage. Selecting suitably the crystal and the X-ray tube, either the line or the continuum emission can be diffracted, producing polarized photons at different energies. A very high degree of polarization and reasonable fluxes can be reached with a suitable choice of the capillary plates collimation. We present the source and test its performances with the production of nearly completely polarized radiation at 2.6, 5.2, 3.7 and 7.4 keV thanks to the employment of graphite and aluminum crystals, with copper and calcium X-ray tubes respectively. Triggered by the very compact design of the source, we also present a feasibility study for an on-board polarized source, coupled to a radioactive Fe55 nuclide and a PVC thin film, for the calibration of the next generation space-borne X-ray polarimeters at 2.6 and 5.9 keV.
[49]  oai:arXiv.org:astro-ph/0609576  [pdf] - 85168
POLARIX: a small mission of x-ray polarimetry
Comments: 9 pages, 5 figures
Submitted: 2006-09-20
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX has been conceived as such a pathfinder. It is a Small Satellite based on the optics of JET-X. Two telescopes are available in flight configuration and three more can be easily produced starting from the available superpolished mandrels. We show the capabilities of such a cluster of telescopes each equipped with a focal plane photoelectric polarimeter and discuss a few alternative solutions.
[50]  oai:arXiv.org:astro-ph/0609573  [pdf] - 85165
An X-ray polarimeter for hard X-ray optics
Comments: 12 pages, 7 figures
Submitted: 2006-09-20
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer optics, galatic and extragalactic X-ray polarimetry can be done up till 30 keV.
[51]  oai:arXiv.org:astro-ph/0609571  [pdf] - 85163
A photoelectric polarimeter for XEUS: a new window in x-ray sky
Comments: 12 pages, 7 figures
Submitted: 2006-09-20
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a device is capable to solve open problems on many classes of High Energy Astrophysics objects and to use X-ray sources as a laboratory for a substantial progress on Fundamental Physics.
[52]  oai:arXiv.org:astro-ph/0603399  [pdf] - 80608
Opening a New Window to Fundamental Physics and Astrophysics: X-ray Polarimetry
Comments: 8 pages 1 table 14 figures
Submitted: 2006-03-15
An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescope could open this new window in the High Energy Sky.