sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Morren, Johan

Normalized to: Morren, J.

4 article(s) in total. 28 co-authors, from 1 to 4 common article(s). Median position in authors list is 2,5.

[1]  oai:arXiv.org:1607.02965  [pdf] - 1530996
PLC-controlled cryostats for the BlackGEM and MeerLICHT detectors
Comments: 11 pages, SPIE Astronomical Telescopes and Instrumentation 2016 Conference Proceedings
Submitted: 2016-07-11
BlackGEM (BG) is an array of telescopes, currently under development at the Radboud University Nijmegen and at NOVA. It targets the detection of the optical counterparts of gravitational waves. The first 3 BG telescopes are planned to be installed in 2018 at the La Silla observatory. A single prototype telescope, named MeerLICHT, will already be commissioned early 2017 in Sutherland to provide an optical complement for the MeerKAT radio array. The BG array consists of, initially, a set of 3 robotic 65-cm wide-field telescopes. Each telescope is equipped with a single STA1600 CCD detector with 10.5k x 10.5k 9-mum pixels that covers a 2.7 square degrees field of view. The cryostats for housing these detectors are developed and built at the KU Leuven University. The operational model of BG requires long periods of reliable ands-off operation. Therefore, we designed the cryostats for long vacuum hold time and we make use of a closed-cycle cooling system, based on Polycold PCC Joule-Thomson coolers. A single programmable logic controller (PLC) controls the cryogenic systems of several BG telescopes simultaneously, resulting in a highly reliable, cost-efficient and maintenance-friendly system. PLC-based cryostat control offers some distinct advantages, especially for a robotic facility. Apart of temperature monitoring and control, the PLC also monitors the vacuum quality, the power supply and the status of the PCC coolers (compressor power consumption and temperature, pressure in the gas lines, etc.). Furthermore, it provides an alarming system and safe and reproducible procedures for automatic cool down and warm up. The communication between PLC and higher-level software takes place via the OPC-UA protocol, offering a simple to implement, yet very powerful interface. Finally, a touch-panel display on the PLC provides the operator with a user-friendly and robust technical interface.
[2]  oai:arXiv.org:1311.0685  [pdf] - 741528
Compact Stirling cooling of astronomical detectors
Comments: 10 pages, 7 figures, Proceedings of the Scientific Detector Workshop 2013 (Florence)
Submitted: 2013-11-04
MAIA, a three-channel imager targeting fast cadence photometry, was recently installed on the Mercator telescope (La Palma, Spain). This instrument observes a 9.4 x 14.1 arcmin field of view simultaneously in three color bands ($u$, $g$ and $r$), using three of the largest (un-) available frame-transfer CCDs, namely the 2k x 6k CCD42-C0 from e2v. As these detectors are housed in three separate cryostats, compact cooling devices are required that offer sufficient power to cool the large chips to a temperature of 165K. We explored a broad spectrum of cooling options and technologies to cool the MAIA detectors. Finally, compact free-piston Stirling coolers were selected, namely the CryoTel MT cryo-coolers from SUNPOWER, that can extract 5W of heat at a temperature of 77K. In this contribution we give details of the MAIA detector cooling solution. We also discuss the general usability of this type of closed-cycle cryo-coolers for astronomical detectors. They offer distinct advantages but the vibrations caused by mechanical cryo-cooling impose a serious drawback. We present a solution to mechanically decouple the coolers from the instrument and show some results of how this reduces the vibrations to a level that is acceptable for most applications on astronomical telescopes.
[3]  oai:arXiv.org:1310.2266  [pdf] - 1179808
MAIA, a three-channel imager for asteroseismology: instrument design
Comments: 11 pages, 10 figures, Accepted by Astronomy and Astrophysics
Submitted: 2013-10-08
MAIA, an acronym for Mercator Advanced Imager for Asteroseismology, is a three-channel instrument that targets fast-cadence three-colour photometry, installed at the 1.2-m Mercator telescope at the Roque de los Muchachos at La Palma (Canary Islands, Spain). This instrument observes a 9.4x14.1arcmin2 Field-of-View simultaneously in three wavelength bands on three large frame-transfer CCDs. These detectors were developed for ESA's cancelled Eddington space mission and were offered on permanent loan to the Institute of Astronomy (KU Leuven, Belgium). MAIA uses its own ugr photometric system that is a crude approximation of the SDSS system. The instrument is designed to perform multi-colour observations for asteroseismology, with specific emphasis on subdwarf and white dwarf single and binary stars. We describe the design of the instrument, discuss key components, and report on its performance and first results.
[4]  oai:arXiv.org:1011.0258  [pdf] - 1041654
HERMES: a high-resolution fibre-fed spectrograph for the Mercator telescope
Comments: 13 pages
Submitted: 2010-11-01
The HERMES high-resolution spectrograph project aims at exploiting the specific potential of small but flexible telescopes in observational astrophysics. The optimised optical design of the spectrograph is based on the well-proven concept of white-pupil beam folding for high-resolution spectroscopy. In this contribution we present the complete project, including the spectrograph design and procurement details, the telescope adaptor and calibration unit, the detector system, as well as the optimised data-reduction pipeline. We present a detailed performance analysis to show that the spectrograph performs as specified both in optical quality and in total efficiency. With a spectral resolution of 85000 (63000 for the low-resolution fibre), a spectral coverage from 377 to 900nm in a single exposure and a peak efficiency of 28%, HERMES proves to be an ideal instrument for building up time series of high-quality data of variable (stellar) phenomena.