sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Morozov, D. V.

Normalized to: Morozov, D.

4 article(s) in total. 23 co-authors, from 1 to 3 common article(s). Median position in authors list is 6,0.

[1]  oai:arXiv.org:1905.07410  [pdf] - 1885699
Cosmic Inference: Constraining Parameters With Observations and Highly Limited Number of Simulations
Comments: 23 pages, 17 figures, submitted to ApJ
Submitted: 2019-05-17
Cosmological probes pose an inverse problem where the measurement result is obtained through observations, and the objective is to infer values of model parameters which characterize the underlying physical system -- our Universe. Modern cosmological probes increasingly rely on measurements of the small-scale structure, and the only way to accurately model physical behavior on those scales, roughly 65 Mpc/h or smaller, is via expensive numerical simulations. In this paper, we provide a detailed description of a novel statistical framework for obtaining accurate parameter constraints by combining observations with a very limited number of cosmological simulations. The proposed framework utilizes multi-output Gaussian process emulators that are adaptively constructed using Bayesian optimization methods. We compare several approaches for constructing multi-output emulators that enable us to take possible inter-output correlations into account while maintaining the efficiency needed for inference. Using Lyman alpha forest flux power spectrum, we demonstrate that our adaptive approach requires considerably fewer --- by a factor of a few in Lyman alpha P(k) case considered here --- simulations compared to the emulation based on Latin hypercube sampling, and that the method is more robust in reconstructing parameters and their Bayesian credible intervals.
[2]  oai:arXiv.org:1603.07944  [pdf] - 1388264
Optical performance of an ultra-sensitive horn-coupled transition-edge-sensor bolometer with hemispherical backshort in the far infrared
Comments: 22 pages, 11 figures. The following article has been accepted by Review of Scientific Instruments. After it is published, it will be found at http://scitation.aip.org/content/aip/journal/rsi
Submitted: 2016-03-25
The next generation of far infrared space observatories will require extremely sensitive detectors that can be realized only by combining extremely low intrinsic noise with high optical efficiency. We have measured the broad-band optical response of ultra-sensitive TES bolometers (NEP$\approx2\rm\ aW/\sqrt Hz$) in the 30--60-$\mu\rm m$ band where radiation is coupled to the detectors with a few-moded conical feedhorn and a hemispherical backshort. We show that these detectors have an optical efficiency of 60% (the ratio of the power detected by the TES bolometer to the total power propagating through the feedhorn). We find that the measured optical efficiency can be understood in terms of the modes propagating through the feedhorn with the aid of a spatial mode-filtering technique.
[3]  oai:arXiv.org:1603.03309  [pdf] - 1372118
Optical Response of Strained- and Unstrained-Silicon Cold-Electron Bolometers
Comments: Accepted for publication in Journal of Low Tempature Physics
Submitted: 2016-03-10
We describe the optical characterisation of two silicon cold-electron bolometers each consisting of a small ($32 \times 14~\mathrm{\mu m}$) island of degenerately doped silicon with superconducting aluminium contacts. Radiation is coupled into the silicon absorber with a twin-slot antenna designed to couple to 160-GHz radiation through a silicon lens.The first device has a highly doped silicon absorber, the second has a highly doped strained-silicon absorber.Using a novel method of cross-correlating the outputs from two parallel amplifiers, we measure noise-equivalent powers of $3.0 \times 10^{-16}$ and $6.6 \times 10^{-17}~\mathrm{W\,Hz^{-1/2}}$ for the control and strained device, respectively, when observing radiation from a 77-K source. In the case of the strained device, the noise-equivalent power is limited by the photon noise.
[4]  oai:arXiv.org:1407.2113  [pdf] - 860359
A Strained Silicon Cold Electron Bolometer using Schottky Contacts
Comments: Published in Applied Physics Letters, 105, pp. 043509
Submitted: 2014-07-08, last modified: 2014-07-31
We describe optical characterisation of a Strained Silicon Cold Electron Bolometer (CEB), operating on a $350~\mathrm{mK}$ stage, designed for absorption of millimetre-wave radiation. The silicon Cold Electron Bolometer utilises Schottky contacts between a superconductor and an n++ doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to $160~\mathrm{GHz}$ and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of $50~\%$ for radiation coupled into the device by the planar antenna and an overall noise equivalent power (NEP), referred to absorbed optical power, of $1.1 \times 10^{-16}~\mathrm{\mbox{W Hz}^{-1/2}}$ when the detector is observing a $300~\mathrm{K}$ source through a $4~\mathrm{K}$ throughput limiting aperture. Even though this optical system is not optimised we measure a system noise equivalent temperature difference (NETD) of $6~\mathrm{\mbox{mK Hz}^{-1/2}}$. We measure the noise of the device using a cross-correlation of time stream data measured simultaneously with two junction field-effect transistor (JFET) amplifiers, with a base correlated noise level of $300~\mathrm{\mbox{pV Hz}^{-1/2}}$ and find that the total noise is consistent with a combination of photon noise, current shot noise and electron-phonon thermal noise.