Normalized to: Morigi, G.
[1]
oai:arXiv.org:1001.4778 [pdf] - 33192
Planck-LFI: Design and Performance of the 4 Kelvin Reference Load Unit
Valenziano, Luca;
Cuttaia, Francesco;
De Rosa, Adriano;
Terenzi, Luca;
Brighenti, Alberto;
Cazzola, GianPaolo;
Garbesi, Anna;
Mariotti, Sergio;
Orsi, Giordano;
Pagan, Luca;
Cavaliere, Francesco;
Lapini, Roberto;
Biggi, Matteo;
Panagin, Enzo;
Paola, Battaglia;
Butler, Chris;
Bersanelli, Marco;
D'Arcangelo, Ocleto;
Levin, Steve;
Mandolesi, Nazzareno;
Mennella, Aniello;
Morgante, Gianluca;
Morigi, Gabriele;
Sandri, Maura;
Simonetto, Alessandro;
Tomasi, Maurizio;
Villa, Fabrizio;
Frailis, Marco;
Galeotta, Samuele;
Gregorio, Anna;
Leonardi, Rodrigo;
Lowe, Stuart;
Maris, Michele;
Meinhold, Peter;
Mendes, Luis;
Stringhetti, Luca;
Zonca, Andrea;
Zacchei, Andrea
Submitted: 2010-01-26
The LFI radiometers use a pseudo-correlation design where the signal from the
sky is continuously compared with a stable reference signal, provided by a
cryogenic reference load system. The reference unit is composed by small
pyramidal horns, one for each radiometer, 22 in total, facing small absorbing
targets, made of a commercial resin ECCOSORB CR (TM), cooled to approximately
4.5 K. Horns and targets are separated by a small gap to allow thermal
decoupling. Target and horn design is optimized for each of the LFI bands,
centered at 70, 44 and 30 GHz. Pyramidal horns are either machined inside the
radiometer 20K module or connected via external electro-formed bended
waveguides. The requirement of high stability of the reference signal imposed a
careful design for the radiometric and thermal properties of the loads.
Materials used for the manufacturing have been characterized for thermal, RF
and mechanical properties. We describe in this paper the design and the
performance of the reference system.
[2]
oai:arXiv.org:1001.2657 [pdf] - 1024642
Planck pre-launch status: the Planck-LFI programme
Mandolesi, N.;
Bersanelli, M.;
Butler, R. C.;
Artal, E.;
Baccigalupi, C.;
Balbi, A.;
Banday, A. J.;
Barreiro, R. B.;
Bartelmann, M.;
Bennett, K.;
Bhandari, P.;
Bonaldi, A.;
Borrill, J.;
Bremer, M.;
Burigana, C.;
Bowman, R. C.;
Cabella, P.;
Cantalupo, C.;
Cappellini, B.;
Courvoisier, T.;
Crone, G.;
Cuttaia, F.;
Danese, L.;
D'Arcangelo, O.;
Davies, R. D.;
Davis, R. J.;
De Angelis, L.;
de Gasperis, G.;
De Rosa, A.;
De Troia, G.;
de Zotti, G.;
Dick, J.;
Dickinson, C.;
Diego, J. M.;
Donzelli, S.;
Dörl, U.;
Dupac, X.;
Enßlin, T. A.;
Eriksen, H. K.;
Falvella, M. C.;
Finelli, F.;
Frailis, M.;
Franceschi, E.;
Gaier, T.;
Galeotta, S.;
Gasparo, F.;
Giardino, G.;
Gomez, F.;
Gonzalez-Nuevo, J.;
Górski, K. M.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F.;
Hell, R.;
Herranz, D.;
Herreros, J. M.;
Hildebrandt, S.;
Hovest, W.;
Hoyland, R.;
Huffenberger, K.;
Janssen, M.;
Jaffe, T.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T.;
Kurki-Suonio, H.;
Lähteenmäki, A.;
Lawrence, C. R.;
Leach, S. M.;
Leahy, J. P.;
Leonardi, R.;
Levin, S.;
Lilje, P. B.;
López-Caniego, M.;
Lowe, S. R.;
Lubin, P. M.;
Maino, D.;
Malaspina, M.;
Maris, M.;
Marti-Canales, J.;
Martinez-Gonzalez, E.;
Massardi, M.;
Matarrese, S.;
Matthai, F.;
Meinhold, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Morgante, G.;
Morigi, G.;
Morisset, N.;
Moss, A.;
Nash, A.;
Natoli, P.;
Nesti, R.;
Paine, C.;
Partridge, B.;
Pasian, F.;
Passvogel, T.;
Pearson, D.;
Pérez-Cuevas, L.;
Perrotta, F.;
Polenta, G.;
Popa, L. A.;
Poutanen, T.;
Prezeau, G.;
Prina, M.;
Rachen, J. P.;
Rebolo, R.;
Reinecke, M.;
Ricciardi, S.;
Riller, T.;
Rocha, G.;
Roddis, N.;
Rohlfs, R.;
Rubiño-Martin, J. A.;
Salerno, E.;
Sandri, M.;
Scott, D.;
Seiffert, M.;
Silk, J.;
Simonetto, A.;
Smoot, G. F.;
Sozzi, C.;
Sternberg, J.;
Stivoli, F.;
Stringhetti, L.;
Tauber, J.;
Terenzi, L.;
Tomasi, M.;
Tuovinen, J.;
Türler, M.;
Valenziano, L.;
Varis, J.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L.;
White, M.;
White, S.;
Wilkinson, A.;
Zacchei, A.;
Zonca, A.
Submitted: 2010-01-15
This paper provides an overview of the Low Frequency Instrument (LFI)
programme within the ESA Planck mission. The LFI instrument has been developed
to produce high precision maps of the microwave sky at frequencies in the range
27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation
spectrum. The scientific goals are described, ranging from fundamental
cosmology to Galactic and extragalactic astrophysics. The instrument design and
development are outlined, together with the model philosophy and testing
strategy. The instrument is presented in the context of the Planck mission. The
LFI approach to ground and inflight calibration is described. We also describe
the LFI ground segment. We present the results of a number of tests
demonstrating the capability of the LFI data processing centre (DPC) to
properly reduce and analyse LFI flight data, from telemetry information to
calibrated and cleaned time ordered data, sky maps at each frequency (in
temperature and polarization), component emission maps (CMB and diffuse
foregrounds), catalogs for various classes of sources (the Early Release
Compact Source Catalogue and the Final Compact Source Catalogue). The
organization of the LFI consortium is briefly presented as well as the role of
the core team in data analysis and scientific exploitation. All tests carried
out on the LFI flight model demonstrate the excellent performance of the
instrument and its various subunits. The data analysis pipeline has been tested
and its main steps verified. In the first three months after launch, the
commissioning, calibration, performance, and verification phases will be
completed, after which Planck will begin its operational life, in which LFI
will have an integral part.
[3]
oai:arXiv.org:astro-ph/0411412 [pdf] - 69011
The Planck Low Frequency Instrument
Mandolesi, N.;
Burigana, C.;
Butler, R. C.;
Cuttaia, F.;
De Rosa, A.;
Finelli, F.;
Franceschi, E.;
Gruppuso, A.;
Malaspina, M.;
Morgante, G.;
Morigi, G.;
Popa, L.;
Sandri, M.;
Stringhetti, L.;
Terenzi, L.;
Valenziano, L.;
Villa, F.
Submitted: 2004-11-15
Planck is the third generation of mm-wave instruments designed for space
observations of the cosmic microwave background (CMB) anisotropies within the
new Cosmic Vision 2020 ESA Science Program. Planck will map the whole sky with
unprecedented sensitivity, angular resolution, and frequency coverage, and it
likely leads us to the final comprehension of the CMB anisotropies. The Low
Frequency Instrument (LFI), operating in the 30-70 GHz range, is one of the two
instruments onboard Planck satellite, sharing the focal region of a 1.5 meter
off-axis dual reflector telescope together with the High Frequency Instrument
(HFI) operating at 100-857 GHz. We present LFI and discuss the major
instrumental systematic effects that could degrade the measurements and the
solutions adopted in the design and data analysis phase in order to adequately
reduce and control them.