Normalized to: Morgan, F.
[1]
oai:arXiv.org:2001.03524 [pdf] - 2065361
In-Flight Performance and Calibration of the LOng Range Reconnaissance
Imager (LORRI) for the New Horizons Mission
Weaver, H. A.;
Cheng, A. F.;
Morgan, F.;
Taylor, H. W.;
Conard, S. J.;
Nunez, J. I.;
Rodgers, D. J.;
Lauer, T. R.;
Owen, W. M.;
Spencer, J. R.;
Barnouin, O.;
Rivkin, A. S.;
Olkin, C. B.;
Stern, S. A.;
Young, L. A.;
Tapley, M. B.;
Vincent, M.
Submitted: 2020-01-10
The LOng Range Reconnaissance Imager (LORRI) is a panchromatic (360--910 nm),
narrow-angle (field of view = 0.29 deg), high spatial resolution (pixel scale =
1.02 arcsec) visible light imager used on NASA's New Horizons (NH) mission for
both science observations and optical navigation. Calibration observations
began several months after the NH launch on 2006 January 19 and have been
repeated annually throughout the course of the mission, which is ongoing. This
paper describes the in-flight LORRI calibration measurements, and the results
derived from our analysis of the calibration data. LORRI has been remarkably
stable over time with no detectable changes (at the 1% level) in sensitivity or
optical performance since launch. By employing 4 by 4 re-binning of the CCD
pixels during read out, a special spacecraft tracking mode, exposure times of
30 sec, and co-addition of approximately 100 images, LORRI can detect
unresolved targets down to V = 22 (SNR=5). LORRI images have an instantaneous
dynamic range of 3500, which combined with exposure time control ranging from
0ms to 64,967 ms in 1ms steps supports high resolution, high sensitivity
imaging of planetary targets spanning heliocentric distances from Jupiter to
deep in the Kuiper belt, enabling a wide variety of scientific investigations.
We describe here how to transform LORRI images from raw (engineering) units
into scientific (calibrated) units for both resolved and unresolved targets. We
also describe various instrumental artifacts that could affect the
interpretation of LORRI images under some observing circumstances.