Normalized to: Morgan, B.
[1]
oai:arXiv.org:1602.03781 [pdf] - 1384743
A review of the discovery reach of directional Dark Matter detection
Mayet, F.;
Green, A. M.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Gelmini, G. B.;
Gondolo, P.;
Kavanagh, B. J.;
Lee, S. K.;
Loomba, D.;
Monroe, J.;
Morgan, B.;
O'Hare, C. A. J.;
Peter, A. H. G.;
Phan, N. S.;
Vahsen, S. E.
Submitted: 2016-02-11, last modified: 2016-03-17
Cosmological observations indicate that most of the matter in the Universe is
Dark Matter. Dark Matter in the form of Weakly Interacting Massive Particles
(WIMPs) can be detected directly, via its elastic scattering off target nuclei.
Most current direct detection experiments only measure the energy of the
recoiling nuclei. However, directional detection experiments are sensitive to
the direction of the nuclear recoil as well. Due to the Sun's motion with
respect to the Galactic rest frame, the directional recoil rate has a dipole
feature, peaking around the direction of the Solar motion. This provides a
powerful tool for demonstrating the Galactic origin of nuclear recoils and
hence unambiguously detecting Dark Matter. Furthermore, the directional recoil
distribution depends on the WIMP mass, scattering cross section and local
velocity distribution. Therefore, with a large number of recoil events it will
be possible to study the physics of Dark Matter in terms of particle and
astrophysical properties. We review the potential of directional detectors for
detecting and characterizing WIMPs.
[2]
oai:arXiv.org:1208.4992 [pdf] - 673135
Probing light WIMPs with directional detection experiments
Submitted: 2012-08-24, last modified: 2012-10-08
The CoGeNT and CRESST WIMP direct detection experiments have recently
observed excesses of nuclear recoil events, while the DAMA/LIBRA experiment has
a long standing annual modulation signal. It has been suggested that these
excesses may be due to light mass, m_chi ~ 5-10 GeV, WIMPs. The Earth's motion
with respect to the Galactic rest frame leads to a directional dependence in
the WIMP scattering rate, providing a powerful signal of the Galactic origin of
any recoil excess. We investigate whether direct detection experiments with
directional sensitivity have the potential to observe this anisotropic
scattering rate with the elastically scattering light WIMPs proposed to explain
the observed excesses. We find that the number of recoils required to detect an
anisotropic signal from light WIMPs at 5 sigma significance varies from 7 to
more than 190 over the set of target nuclei and energy thresholds expected for
directional detectors. Smaller numbers arise from configurations where the
detector is only sensitive to recoils from the highest speed, and hence most
anisotropic, WIMPs. However, the event rate above threshold is very small in
these cases, leading to the need for large experimental exposures to accumulate
even a small number of events. To account for this sensitivity to the tail of
the WIMP velocity distribution, whose shape is not well known, we consider two
exemplar halo models spanning the range of possibilities. We also note that for
an accurate calculation the Earth's orbital speed must be averaged over. We
find that the exposures required to detect 10 GeV WIMPs at a WIMP-proton
cross-section of 10^-4 pb are of order 10^3 kg day for a 20 keV energy
threshold, within reach of planned directional detectors. Lower WIMP masses
require higher exposures and/or lower energy thresholds for detection.
[3]
oai:arXiv.org:1002.2717 [pdf] - 163227
The median recoil direction as a WIMP directional detection signal
Submitted: 2010-02-13, last modified: 2010-03-03
Direct detection experiments have reached the sensitivity required to detect
dark matter WIMPs. Demonstrating that a putative signal is due to WIMPs, and
not backgrounds, is a major challenge however. The direction dependence of the
WIMP scattering rate provides a potential WIMP `smoking gun'. If the WIMP
distribution is predominantly smooth, the Galactic recoil distribution is
peaked in the direction opposite to the direction of Solar motion. Previous
studies have found that, for an ideal detector, of order 10 WIMP events would
be sufficient to reject isotropy, and rule out an isotropic background. We
examine how the median recoil direction could be used to confirm the WIMP
origin of an anisotropic recoil signal. Specifically we determine the number of
events required to reject the null hypothesis that the median direction is
random (corresponding to an isotropic Galactic recoil distribution) at 95%
confidence. We find that for zero background 31 events are required, a factor
of roughly 2 more than are required to simply reject isotropy. We also
investigate the effect of a non-zero isotropic background. As the background
rate is increased the number of events required increases, initially fairly
gradually and then more rapidly, once the signal becomes subdominant. We also
discuss the effect of features in the speed distribution at large speeds, as
found in recent high resolution simulations, on the median recoil direction.
[4]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[5]
oai:arXiv.org:0711.2234 [pdf] - 7037
Consequences of statistical sense determination for WIMP directional
detection
Submitted: 2007-11-14, last modified: 2007-12-14
We study the consequences of limited recoil sense reconstruction on the
number of events required to reject isotropy and detect a WIMP signal using a
directional detector. For a constant probability of determining the sense
correctly, 3-d read-out and zero background, we find that as the probability is
decreased from 1.0 to 0.75 the number of events required to reject isotropy
using the mean angle statistic is increased by a factor of a few. As the
probability is decreased further the number of events required using this
statistic increases sharply, and in fact isotropy can be rejected more easily
by discarding the sense information and using axial statistics. This however
requires an order of magnitude more events than vectorial data with perfect
sense determination. We also consider energy dependent probabilities of
correctly measuring the sense, 2-d read-out and non-zero background. Our main
conclusion regarding the sense determination is that correctly determining the
sense of the abundant, but less anisotropic, low energy recoils is most
important for minimising the number of events required.
[6]
oai:arXiv.org:astro-ph/0701858 [pdf] - 88987
First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase
xenon detector for dark matter detection
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Cashmore, R. J.;
Chagani, H.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Gao, J.;
Ghag, C.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Korolkova, E. V.;
Kudryavtsev, V. A.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Neves, F.;
Nicklin, G. G.;
Ooi, W.;
Paling, S. M.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R. M.;
Quenby, J. J.;
Robinson, M.;
Sergiampietri, F.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F. L. H.
Submitted: 2007-01-30, last modified: 2007-01-31
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
[7]
oai:arXiv.org:astro-ph/0609115 [pdf] - 84707
Optimizing WIMP directional detectors
Submitted: 2006-09-05, last modified: 2006-10-04
We study the dependence of the exposure required to directly detect a WIMP
directional recoil signal on the capabilities of a directional detector.
Specifically we consider variations in the nuclear recoil energy threshold, the
background rate, whether the detector measures the recoil momentum vector in 2
or 3 dimensions and whether or not the sense of the momentum vector can be
determined. We find that the property with the biggest effect on the required
exposure is the measurement of the momentum vector sense. If the detector
cannot determine the recoil sense, the exposure required is increased by an
order of magnitude for 3-d read-out and two orders of magnitude for 2-d
read-out. For 2-d read-out the required exposure, in particular if the senses
can not be measured, can be significantly reduced by analyzing the reduced
angles with the, time dependent, projected direction of solar motion
subtracted. The background rate effectively places a lower limit on the WIMP
cross-section to which the detector is sensitive; it will be very difficult to
detect WIMPs with a signal rate more than an order of magnitude below the
background rate. Lowering the energy threshold also reduces the required
exposure, but only for thresholds above 20 keV.
[8]
oai:arXiv.org:astro-ph/0605500 [pdf] - 82187
The ZEPLIN-III dark matter detector: instrument design, manufacture and
commissioning
Akimov, D. Yu.;
Alner, G. J.;
Araujo, H. M.;
Bewick, A.;
Bungau, C.;
Burenkov, A. A.;
Carson, M. J.;
Chepel, V.;
Cline, D.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Chag, C.;
Hollingworth, R. J.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Kuznetsov, I. S.;
Lawson, T.;
Lebedenko, V. N.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G. G.;
Paling, S. M.;
Muna, D.;
da Cunha, J. Pinto;
Plank, S. J. S.;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Thorne, C.;
Tovey, D. R.;
Tziaferi, E.;
Walker, R. J.;
Wang, H.;
White, J.;
Wolfs, F.
Submitted: 2006-05-19
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
[9]
oai:arXiv.org:astro-ph/0603243 [pdf] - 80452
The ZEPLIN-III dark matter detector: performance study using an
end-to-end simulation tool
Araujo, H. M.;
Akimov, D. Yu.;
Alner, G. J.;
Bewick, A.;
Bungau, C.;
Camanzi, B.;
Carson, M. J.;
Chepel, V.;
Chagani, H.;
Davidge, D.;
Davies, J. C.;
Daw, E.;
Dawson, J.;
Durkin, T.;
Edwards, B.;
Gamble, T.;
Ghag, C.;
Hollingworth, R.;
Howard, A. S.;
Jones, W. G.;
Joshi, M.;
Kirkpatrick, J.;
Kovalenko, A.;
Kudryavtsev, V. A.;
Lebedenko, V. N.;
Lawson, T.;
Lewin, J. D.;
Lightfoot, P.;
Lindote, A.;
Liubarsky, I.;
Lopes, M. I.;
Luscher, R.;
Majewski, P.;
Mavrokoridis, K.;
McMillan, J.;
Morgan, B.;
Muna, D.;
Murphy, A. S.;
Neves, F.;
Nicklin, G.;
Paling, S.;
da Cunha, J. Pinto;
Preece, R.;
Quenby, J. J.;
Robinson, M.;
Silva, C.;
Solovov, V. N.;
Smith, N. J. T.;
Smith, P. F.;
Spooner, N. J. C.;
Stekhanov, V.;
Sumner, T. J.;
Tovey, D. R.;
Thorne, C.;
Tziaferi, E.;
Walker, R. J.
Submitted: 2006-03-09
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
[10]
oai:arXiv.org:physics/0601012 [pdf] - 119140
Development of Ground-testable Phase Fresnel Lenses in Silicon
Submitted: 2006-01-03
Diffractive/refractive optics, such as Phase Fresnel Lenses (PFL's), offer
the potential to achieve excellent imaging performance in the x-ray and
gamma-ray photon regimes. In principle, the angular resolution obtained with
these devices can be diffraction limited. Furthermore, improvements in signal
sensitivity can be achieved as virtually the entire flux incident on a lens can
be concentrated onto a small detector area. In order to verify experimentally
the imaging performance, we have fabricated PFL's in silicon using gray-scale
lithography to produce the required Fresnel profile. These devices are to be
evaluated in the recently constructed 600-meter x-ray interferometry testbed at
NASA/GSFC. Profile measurements of the Fresnel structures in fabricated PFL's
have been performed and have been used to obtain initial characterization of
the expected PFL imaging efficiencies.
[11]
oai:arXiv.org:astro-ph/0508134 [pdf] - 75023
Directional Statistics for WIMP direct detection II: 2-d read-out
Submitted: 2005-08-04, last modified: 2005-11-17
The direction dependence of the WIMP direct detection rate provides a
powerful tool for distinguishing a WIMP signal from possible backgrounds. We
study the the number of events required to discriminate a WIMP signal from an
isotropic background for a detector with 2-d read-out using non-parametric
circular statistics. We also examine the number of events needed to i) detect a
deviation from rotational symmetry, due to flattening of the Milky Way halo and
ii) detect a deviation in the mean direction due to a tidal stream. If the
senses of the recoils are measured then of order 20-70 events (depending on the
plane of the 2-d read out) will be sufficient to reject isotropy of the raw
recoil angles at 90% confidence. If the senses can not be measured these number
increase by roughly two orders of magnitude (compared with an increase of one
order of magnitude for the case of full 3-d read-out). The distributions of the
reduced angles, with the (time dependent) direction of solar motion subtracted,
are far more anisotropic, however, and if the isotropy tests are applied to
these angles then the numbers of events required are similar to the case of 3-d
read-out. A deviation from rotational symmetry will only be detectable if the
Milky Way halo is significantly flattened. The deviation in the mean direction
due to a tidal stream is potentially detectable, however, depending on the
density and direction of the stream.
[12]
oai:arXiv.org:astro-ph/0408047 [pdf] - 265339
Directional statistics for WIMP direct detection
Submitted: 2004-08-03, last modified: 2005-05-03
The direction dependence of the event rate in WIMP direct detection
experiments provides a powerful tool for distinguishing WIMP events from
potential backgrounds. We use a variety of (non-parametric) statistical tests
to examine the number of events required to distinguish a WIMP signal from an
isotropic background when the uncertainty in the reconstruction of the nuclear
recoil direction is included in the calculation of the expected signal. We
consider a range of models for the Milky Way halo, and also study rotational
symmetry tests aimed at detecting non-sphericity/isotropy of the Milky Way
halo. Finally we examine ways of detecting tidal streams of WIMPs. We find that
if the senses of the recoils are known then of order ten events will be
sufficient to distinguish a WIMP signal from an isotropic background for all of
the halo models considered, with the uncertainties in reconstructing the recoil
direction only mildly increasing the required number of events. If the senses
of the recoils are not known the number of events required is an order of
magnitude larger, with a large variation between halo models, and the recoil
resolution is now an important factor. The rotational symmetry tests require of
order a thousand events to distinguish between spherical and significantly
triaxial halos, however a deviation of the peak recoil direction from the
direction of the solar motion due to a tidal stream could be detected with of
order a hundred events, regardless of whether the sense of the recoils is
known.
[13]
oai:arXiv.org:hep-ex/0109013 [pdf] - 363345
Study and suppression of anomalous fast events in inorganic
scintillators for dark matter searches
Kudryavtsev, V. A.;
Spooner, N. J. C.;
Lightfoot, P. K.;
Roberts, J. W.;
Lehner, M. J.;
Gamble, T.;
Carson, M. J.;
Lawson, T. B.;
Luscher, R.;
McMillan, J. E.;
Morgan, B.;
Paling, S. M.;
Robinson, M.;
Tovey, D. R.;
Smith, N. J. T.;
Smith, P. F.;
Alner, G. J.;
Hart, S. P.;
Lewin, J. D.;
Preece, R. M.;
Sumner, T. J.;
Jones, W. G.;
Quenby, J. J.;
Ahmed, B.;
Bewick, A.;
Davidge, D.;
Dawson, J. V.;
Howard, A. S.;
Ivaniouchenkov, I.;
Joshi, M. K.;
Lebedenko, V.;
Liubarsky, I.;
Barton, J. C.;
Gerbier, G.;
Mallet, J.;
Mosca, L.;
Tao, C.
Submitted: 2001-09-12
The status of dark matter searches with inorganic scintillator detectors at
Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are
presented. The objectives of the latter experiment were to study anomalous fast
events previously observed and to identify ways to remove this background.
Clear indications were found that these events were due to surface
contamination of crystals by alphas, probably from radon decay. A new array of
unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure
nitrogen atmosphere is under construction at Boulby. Such an approach allows
complete control of the surface of the crystals and the ability to remove any
surface contamination. First data from the unencapsulated NaI(Tl) do not show
the presence of anomalous fast events.