sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Moreau, V.

Normalized to: Moreau, V.

4 article(s) in total. 58 co-authors, from 1 to 3 common article(s). Median position in authors list is 9,5.

[1]  oai:arXiv.org:1508.02488  [pdf] - 1260877
The Mid-Infrared Instrument for the James Webb Space Telescope, III: MIRIM, The MIRI Imager
Comments: 29 pages, 9 figures
Submitted: 2015-08-11
In this article, we describe the MIRI Imager module (MIRIM), which provides broad-band imaging in the 5 - 27 microns wavelength range for the James Webb Space Telescope. The imager has a 0"11 pixel scale and a total unobstructed view of 74"x113". The remainder of its nominal 113"x113" field is occupied by the coronagraphs and the low resolution spectrometer. We present the instrument optical and mechanical design. We show that the test data, as measured during the test campaigns undertaken at CEA-Saclay, at the Rutherford Appleton Laboratory, and at the NASA Goddard Space Flight Center, indicate that the instrument complies with its design requirements and goals. We also discuss the operational requirements (multiple dithers and exposures) needed for optimal scientific utilization of the MIRIM.
[2]  oai:arXiv.org:1508.02417  [pdf] - 1264208
The Mid-Infrared Instrument for the James Webb Space Telescope, VIII: The MIRI Focal Plane System
Comments:
Submitted: 2015-08-10
We describe the layout and unique features of the focal plane system for MIRI. We begin with the detector array and its readout integrated circuit (combining the amplifier unit cells and the multiplexer), the electronics, and the steps by which the data collection is controlled and the output signals are digitized and delivered to the JWST spacecraft electronics system. We then discuss the operation of this MIRI data system, including detector readout patterns, operation of subarrays, and data formats. Finally, we summarize the performance of the system, including remaining anomalies that need to be corrected in the data pipeline.
[3]  oai:arXiv.org:1207.2513  [pdf] - 1124732
Design Differences between the Pan-STARRS PS1 and PS2 Telescopes
Comments: 15 pages, 16 figures
Submitted: 2012-07-10
The PS2 telescope is the second in an array of wide-field telescopes that is being built for the Panoramic-Survey Telescope and Rapid Response System (Pan-STARRS) on Haleakala. The PS2 design has evolved incrementally based on lessons learned from PS1, but these changes should result in significant improvements in image quality, tracking performance in windy conditions, and reductions in scattered light. The optics for this telescope are finished save for their coatings and the fabrication for the telescope structure itself is well on the way towards completion and installation on-site late this year (2012). The most significant differences between the two telescopes include the following: secondary mirror support changes, improvements in the optical polishing, changes in the optical coatings to improve throughput and decrease ghosting, removal of heat sources inside the mirror cell, expansion of the primary mirror figure control system, changes in the baffle designs, and an improved cable wrap design. This paper gives a description of each of these design changes and discusses the motivations for making them.
[4]  oai:arXiv.org:1006.5735  [pdf] - 1033405
Optical performance of the JWST MIRI flight model: characterization of the point spread function at high-resolution
Comments: 13 pages, submitted to SPIE Proceedings vol. 7731, Space Telescopes and Instrumentation 2010: Optical, Infrared, and Millimeter Wave
Submitted: 2010-06-29
The Mid Infra Red Instrument (MIRI) is one of the four instruments onboard the James Webb Space Telescope (JWST), providing imaging, coronagraphy and spectroscopy over the 5-28 microns band. To verify the optical performance of the instrument, extensive tests were performed at CEA on the flight model (FM) of the Mid-InfraRed IMager (MIRIM) at cryogenic temperatures and in the infrared. This paper reports on the point spread function (PSF) measurements at 5.6 microns, the shortest operating wavelength for imaging. At 5.6 microns the PSF is not Nyquist-sampled, so we use am original technique that combines a microscanning measurement strategy with a deconvolution algorithm to obtain an over-resolved MIRIM PSF. The microscanning consists in a sub-pixel scan of a point source on the focal plane. A data inversion method is used to reconstruct PSF images that are over-resolved by a factor of 7 compared to the native resolution of MIRI. We show that the FWHM of the high-resolution PSFs were 5-10% wider than that obtained with Zemax simulations. The main cause was identified as an out-of-specification tilt of the M4 mirror. After correction, two additional test campaigns were carried out, and we show that the shape of the PSF is conform to expectations. The FWHM of the PSFs are 0.18-0.20 arcsec, in agreement with simulations. 56.1-59.2% of the total encircled energy (normalized to a 5 arcsec radius) is contained within the first dark Airy ring, over the whole field of view. At longer wavelengths (7.7-25.5 microns), this percentage is 57-68%. MIRIM is thus compliant with the optical quality requirements. This characterization of the MIRIM PSF, as well as the deconvolution method presented here, are of particular importance, not only for the verification of the optical quality and the MIRI calibration, but also for scientific applications.