Normalized to: Morana, G.
[1]
oai:arXiv.org:1507.07747 [pdf] - 1264865
Exclusion of Leptophilic Dark Matter Models using XENON100 Electronic
Recoil Data
The XENON Collaboration;
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Cervantes, M.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kaminsky, B.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vitells, O.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2015-07-28
Laboratory experiments searching for galactic dark matter particles
scattering off nuclei have so far not been able to establish a discovery. We
use data from the XENON100 experiment to search for dark matter interacting
with electrons. With no evidence for a signal above the low background of our
experiment, we exclude a variety of representative dark matter models that
would induce electronic recoils. For axial-vector couplings to electrons, we
exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2
GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as
explanation for the long-standing DAMA/LIBRA signal, such as couplings to
electrons through axial-vector interactions at a 4.4 sigma confidence level,
mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
[2]
oai:arXiv.org:1503.07698 [pdf] - 1342737
Lowering the radioactivity of the photomultiplier tubes for the XENON1T
dark matter experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arazi, L.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Buetikofer, L.;
Cardoso, J. M. R.;
Coderre, D.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowksi, M. P.;
Di Giovanni, A.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fieguth, A.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lyashenko, A.;
Macmullin, S.;
Undagoitia, T. Marrodan;
Masbou, J.;
Massoli, F. V.;
Mayani, D.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pakarha, P.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Rauch, L.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Tunnell, C.;
Vitells, O.;
Wall, R.;
Wang, H.;
Weber, M.;
Weinheimer, C.;
Laubenstein, M.
Submitted: 2015-03-26
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.
[3]
oai:arXiv.org:1406.2374 [pdf] - 940307
Conceptual design and simulation of a water Cherenkov muon veto for the
XENON1T experiment
Aprile, E.;
Agostini, F.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Auger, M.;
Balan, C.;
Barrow, P.;
Baudis, L.;
Bauermeister, B.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Breskin, A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Cardoso, J. M. R.;
Colijn, A. P.;
Contreras, H.;
Cussonneau, J. P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Garbini, M.;
Geis, C.;
Goetzke, L. W.;
Grignon, C.;
Gross, E.;
Hampel, W.;
Itay, R.;
Kaether, F.;
Kessler, G.;
Kish, A.;
Landsman, H.;
Lang, R. F.;
Calloch, M. Le;
Lellouch, D.;
Levinson, L.;
Levy, C.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Lyashenko, A.;
MacMullin, S.;
Undagoitia, T. Marrodán;
Masbou, J.;
Massoli, F. V.;
Paras, D. Mayani;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Messina, M.;
Miguez, B.;
Molinario, A.;
Morana, G.;
Murra, M.;
Naganoma, J.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Persiani, R.;
Piastra, F.;
Pienaar, J.;
Plante, G.;
Priel, N.;
Reichard, S.;
Reuter, C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schindler, S.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Tiseni, A.;
Trinchero, G.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer., C.
Submitted: 2014-06-09, last modified: 2015-02-25
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.