sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Morales, R.

Normalized to: Morales, R.

6 article(s) in total. 59 co-authors, from 1 to 4 common article(s). Median position in authors list is 5,5.

[1]  oai:arXiv.org:1009.1095  [pdf] - 1034734
The Imaging Magnetograph eXperiment (IMaX) for the Sunrise balloon-borne solar observatory
Comments: 17 figures
Submitted: 2010-09-06
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by four institutions in Spain that flew on board the Sunrise balloon-borne telesocope in June 2009 for almost six days over the Arctic Circle. As a polarimeter IMaX uses fast polarization modulation (based on the use of two liquid crystal retarders), real-time image accumulation, and dual beam polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the instrument uses a LiNbO3 etalon in double pass and a narrow band pre-filter to achieve a spectral resolution of 85 mAA. IMaX uses the high Zeeman sensitive line of Fe I at 5250.2 AA and observes all four Stokes parameters at various points inside the spectral line. This allows vector magnetograms, Dopplergrams, and intensity frames to be produced that, after reconstruction, reach spatial resolutions in the 0.15-0.18 arcsec range over a 50x50 arcsec FOV. Time cadences vary between ten and 33 seconds, although the shortest one only includes longitudinal polarimetry. The spectral line is sampled in various ways depending on the applied observing mode, from just two points inside the line to 11 of them. All observing modes include one extra wavelength point in the nearby continuum. Gauss equivalent sensitivities are four Gauss for longitudinal fields and 80 Gauss for transverse fields per wavelength sample. The LOS velocities are estimated with statistical errors of the order of 5-40 m/s. The design, calibration and integration phases of the instrument, together with the implemented data reduction scheme are described in some detail.
[2]  oai:arXiv.org:1007.3682  [pdf] - 1033816
Comprehensive transient-state study for CARMENES-NIR high thermal stability
Comments:
Submitted: 2010-07-21
CARMENES has been proposed as a next-generation instrument for the 3.5m Calar Alto Telescope. Its objective is finding habitable exoplanets around M dwarfs through radial velocity measurements (m/s level) in the near-infrared. Consequently, the NIR spectrograph is highly constraint regarding thermal/mechanical requirements. As a first approach, the thermal stability has been limited to \pm 0.01K (within year period) over a working temperature of 243K. This can be achieved by means of several temperature-controlled rooms. The options considered to minimise the complexity of the thermal design are here presented, as well as the transient-state thermal analyses realised to make the best choice.
[3]  oai:arXiv.org:astro-ph/0110634  [pdf] - 45691
The Chandra High Energy Transmission Grating Spectrometer probes the dusty warm absorber in the Seyfert 1 galaxy MCG--6-30-15
Comments: 4 pages, 2 figures, one of two interpretations of the MCG--6-30-15 spectrum as presented during the workshop discussion; to appear in the proceedings of "X-ray Emission from Accretion onto Black Holes", JHU/LHEA Workshop, June 20-23,2001
Submitted: 2001-10-29
The Chandra HETGS spectra of the Seyfert 1 galaxy MCG--6-30-15 show numerous narrow, unresolved (FWHM < 200 km/s) absorption lines from a wide range of ionization states of N, O, Mg, Ne, Si, S, Ar, and Fe. The initial analysis of these data, presented in Lee et al. (2001), shows that a dusty warm absorber model adequately explains the spectral features > 0.48 keV (< 26 A). We attribute previous reports of an apparently highly redshifted O VII edge to the neutral Fe L absorption complex and the O VII resonance series (by transitions higher than He $\gamma$; He $\alpha,\beta,\gamma$ are also seen at lower energies). The implied dust column density needed to explain the FeI L edge feature agrees with that obtained from earlier reddening studies, which had already concluded that the dust should be associated with the ionized absorber (given the relatively lower observed X-ray absorption by cold gas). Our findings contradict the interpretation of Branduardi-Raymont et al. (2001), based on XMM-Newton RGS spectra, that this spectral region is dominated by highly relativistic soft X-ray line emission originating near the central black hole. Here we review these issues pertaining to the soft X-ray spectral features as addressed by Lee et al., (2001). (Details found in Lee et al., 2001, ApJ., 554, L13)
[4]  oai:arXiv.org:astro-ph/0109050  [pdf] - 44549
Weighing black holes with warm absorbers
Comments: 13 pages, 6 figures, 7 tables. MNRAS accepted
Submitted: 2001-09-04
We present a new technique for determining an upper limit for the mass of the black hole in active galactic nuclei showing warm absorption features. The method relies on the balance of radiative and gravitational forces acting on outflowing warm absorber clouds. It has been applied to 6 objects: five Seyfert 1 galaxies: IC 4329a, MCG-6-30-15, NGC 3516, NGC 4051 and NGC 5548; and one radio-quiet quasar: MR 2251-178. We discuss our result in comparison with other methods. The procedure could also be applied to any other radiatively driven optically thin outflow in which the spectral band covering the major absorption is directly observed.
[5]  oai:arXiv.org:astro-ph/0101065  [pdf] - 40203
Revealing the Dusty Warm Absorber in MCG--6-30-15 with the Chandra HETG
Comments: 4.5 pages, 1 color figure, accepted (April 2001) for publication in ApJL, not many changes from the initial submission - updated/added some measuements for the O VII resonance series, and added a discussion about FeO2 grains
Submitted: 2001-01-04, last modified: 2001-04-13
We present detailed evidence for a warm absorber in the Seyfert 1 galaxy MCG--6-30-15 and dispute earlier claims for relativistic O line emission. The HETG spectra show numerous narrow, unresolved (FWHM < 200 km/s) absorption lines from a wide range of ionization states of N, O, Mg, Ne, Si, S, Ar, and Fe. The O VII edge and 1s^2--1snp resonance line series to n=9 are clearly detected at rest in the AGN frame. We attribute previous reports of an apparently highly redshifted O VII edge to the 1s^2--1snp (n > 5) O VII resonance lines, and a neutral Fe L absorption complex. The shape of the Fe L feature is nearly identical to that seen in the spectra of several X-ray binaries, and in laboratory data. The implied dust column density agrees with that obtained from reddening studies, and gives the first direct X-ray evidence for dust embedded in a warm absorber. The O VIII resonance lines and weak edge are also detected, and the spectral rollover below 2 keV is explained by the superposition of numerous absorption lines and edges. We identify, for the first time, a KLL resonance in the O VI photoabsorption cross section, giving a measure of the O VI column density. The O VII (f) emission detected at the systemic velocity implies a covering fraction of ~5% (depending on the observed vs. time-averaged ionizing flux). Our observations show that a dusty warm absorber model is not only adequate to explain all the spectral features > 0.48 keV (< 26 \AA) the data REQUIRE it. This contradicts the interpretation of Branduardi-Raymont et al. (2001) that this spectral region is dominated by highly relativistic line emission from the vicinity of the black hole.
[6]  oai:arXiv.org:astro-ph/0002015  [pdf] - 34358
An extended multi-zone model for the MCG-6-30-15 warm absorber
Comments: 5 pages, 6 figures, accepted for publication in MNRAS
Submitted: 2000-02-01
The variable warm absorber seen with {\em ASCA} in the X-ray spectrum of MCG$-$6-30-15 shows complex time behaviour in which the optical depth of OVIII anticorrelates with the flux whereas that of OVII is unchanging. The explanation in terms of a two zone absorber has since been challenged by {\em BeppoSAX} observations. These present a more complicated behaviour for the OVIII edge. We demonstrate here that the presence of a third, intermediate, zone can explain all the observations. In practice, warm absorbers are likely to be extended, multi-zone regions of which only part causes directly observable absorption edges at any given time.