Normalized to: Morales, R.
[1]
oai:arXiv.org:1009.1095 [pdf] - 1034734
The Imaging Magnetograph eXperiment (IMaX) for the Sunrise balloon-borne
solar observatory
Pillet, V. Martinez;
Iniesta, J. C. del Toro;
Alvarez-Herrero, A.;
Domingo, V.;
Bonet, J. A.;
Fernandez, L. Gonzalez;
Jimenez, A. Lopez;
Pastor, C.;
Blesa, J. L. Gasent;
Mellado, P.;
Piqueras, J.;
Aparicio, B.;
Balaguer, M.;
Ballesteros, E.;
Belenguer, T.;
Rubio, L. R. Bellot;
Berkefeld, T.;
Collados, M.;
Deutsch, W.;
Feller, A.;
Girela, F.;
Grauf, B.;
Heredero, R. L.;
Herranz, M.;
Jeronimo, J. M.;
Laguna, H.;
Meller, R.;
Menendez, M.;
Morales, R.;
Suarez, D. Orozco;
Ramos, G.;
Reina, M.;
Ramos, J. L.;
Rodriguez, P.;
Sanchez, A.;
Uribe-Patarroyo, N.;
Barthol, P.;
Gandorfer, A.;
Knoelker, M.;
Schmidt, W.;
Solanki, S. K.;
Dominguez, S. Vargas
Submitted: 2010-09-06
The Imaging Magnetograph eXperiment (IMaX) is a spectropolarimeter built by
four institutions in Spain that flew on board the Sunrise balloon-borne
telesocope in June 2009 for almost six days over the Arctic Circle. As a
polarimeter IMaX uses fast polarization modulation (based on the use of two
liquid crystal retarders), real-time image accumulation, and dual beam
polarimetry to reach polarization sensitivities of 0.1%. As a spectrograph, the
instrument uses a LiNbO3 etalon in double pass and a narrow band pre-filter to
achieve a spectral resolution of 85 mAA. IMaX uses the high Zeeman sensitive
line of Fe I at 5250.2 AA and observes all four Stokes parameters at various
points inside the spectral line. This allows vector magnetograms, Dopplergrams,
and intensity frames to be produced that, after reconstruction, reach spatial
resolutions in the 0.15-0.18 arcsec range over a 50x50 arcsec FOV. Time
cadences vary between ten and 33 seconds, although the shortest one only
includes longitudinal polarimetry. The spectral line is sampled in various ways
depending on the applied observing mode, from just two points inside the line
to 11 of them. All observing modes include one extra wavelength point in the
nearby continuum. Gauss equivalent sensitivities are four Gauss for
longitudinal fields and 80 Gauss for transverse fields per wavelength sample.
The LOS velocities are estimated with statistical errors of the order of 5-40
m/s. The design, calibration and integration phases of the instrument, together
with the implemented data reduction scheme are described in some detail.
[2]
oai:arXiv.org:1007.3682 [pdf] - 1033816
Comprehensive transient-state study for CARMENES-NIR high thermal
stability
Becerril, S.;
Sánchez, M. A.;
Cárdenas, M. C.;
Rabaza, O.;
Ramón, A.;
Abril, M.;
Costillo, L. P.;
Morales, R.;
Rodríguez, A.;
Amado, P. J.;
team, the international CARMENES
Submitted: 2010-07-21
CARMENES has been proposed as a next-generation instrument for the 3.5m Calar
Alto Telescope. Its objective is finding habitable exoplanets around M dwarfs
through radial velocity measurements (m/s level) in the near-infrared.
Consequently, the NIR spectrograph is highly constraint regarding
thermal/mechanical requirements. As a first approach, the thermal stability has
been limited to \pm 0.01K (within year period) over a working temperature of
243K. This can be achieved by means of several temperature-controlled rooms.
The options considered to minimise the complexity of the thermal design are
here presented, as well as the transient-state thermal analyses realised to
make the best choice.
[3]
oai:arXiv.org:astro-ph/0110634 [pdf] - 45691
The Chandra High Energy Transmission Grating Spectrometer probes the
dusty warm absorber in the Seyfert 1 galaxy MCG--6-30-15
Submitted: 2001-10-29
The Chandra HETGS spectra of the Seyfert 1 galaxy MCG--6-30-15 show numerous
narrow, unresolved (FWHM < 200 km/s) absorption lines from a wide range of
ionization states of N, O, Mg, Ne, Si, S, Ar, and Fe. The initial analysis of
these data, presented in Lee et al. (2001), shows that a dusty warm absorber
model adequately explains the spectral features > 0.48 keV (< 26 A). We
attribute previous reports of an apparently highly redshifted O VII edge to the
neutral Fe L absorption complex and the O VII resonance series (by transitions
higher than He $\gamma$; He $\alpha,\beta,\gamma$ are also seen at lower
energies). The implied dust column density needed to explain the FeI L edge
feature agrees with that obtained from earlier reddening studies, which had
already concluded that the dust should be associated with the ionized absorber
(given the relatively lower observed X-ray absorption by cold gas). Our
findings contradict the interpretation of Branduardi-Raymont et al. (2001),
based on XMM-Newton RGS spectra, that this spectral region is dominated by
highly relativistic soft X-ray line emission originating near the central black
hole. Here we review these issues pertaining to the soft X-ray spectral
features as addressed by Lee et al., (2001). (Details found in Lee et al.,
2001, ApJ., 554, L13)
[4]
oai:arXiv.org:astro-ph/0109050 [pdf] - 44549
Weighing black holes with warm absorbers
Submitted: 2001-09-04
We present a new technique for determining an upper limit for the mass of the
black hole in active galactic nuclei showing warm absorption features. The
method relies on the balance of radiative and gravitational forces acting on
outflowing warm absorber clouds. It has been applied to 6 objects: five Seyfert
1 galaxies: IC 4329a, MCG-6-30-15, NGC 3516, NGC 4051 and NGC 5548; and one
radio-quiet quasar: MR 2251-178. We discuss our result in comparison with other
methods. The procedure could also be applied to any other radiatively driven
optically thin outflow in which the spectral band covering the major absorption
is directly observed.
[5]
oai:arXiv.org:astro-ph/0101065 [pdf] - 40203
Revealing the Dusty Warm Absorber in MCG--6-30-15 with the Chandra HETG
Submitted: 2001-01-04, last modified: 2001-04-13
We present detailed evidence for a warm absorber in the Seyfert 1 galaxy
MCG--6-30-15 and dispute earlier claims for relativistic O line emission. The
HETG spectra show numerous narrow, unresolved (FWHM < 200 km/s) absorption
lines from a wide range of ionization states of N, O, Mg, Ne, Si, S, Ar, and
Fe. The O VII edge and 1s^2--1snp resonance line series to n=9 are clearly
detected at rest in the AGN frame. We attribute previous reports of an
apparently highly redshifted O VII edge to the 1s^2--1snp (n > 5) O VII
resonance lines, and a neutral Fe L absorption complex. The shape of the Fe L
feature is nearly identical to that seen in the spectra of several X-ray
binaries, and in laboratory data. The implied dust column density agrees with
that obtained from reddening studies, and gives the first direct X-ray evidence
for dust embedded in a warm absorber. The O VIII resonance lines and weak edge
are also detected, and the spectral rollover below 2 keV is explained by the
superposition of numerous absorption lines and edges. We identify, for the
first time, a KLL resonance in the O VI photoabsorption cross section, giving a
measure of the O VI column density. The O VII (f) emission detected at the
systemic velocity implies a covering fraction of ~5% (depending on the observed
vs. time-averaged ionizing flux). Our observations show that a dusty warm
absorber model is not only adequate to explain all the spectral features > 0.48
keV (< 26 \AA) the data REQUIRE it. This contradicts the interpretation of
Branduardi-Raymont et al. (2001) that this spectral region is dominated by
highly relativistic line emission from the vicinity of the black hole.
[6]
oai:arXiv.org:astro-ph/0002015 [pdf] - 34358
An extended multi-zone model for the MCG-6-30-15 warm absorber
Submitted: 2000-02-01
The variable warm absorber seen with {\em ASCA} in the X-ray spectrum of
MCG$-$6-30-15 shows complex time behaviour in which the optical depth of OVIII
anticorrelates with the flux whereas that of OVII is unchanging. The
explanation in terms of a two zone absorber has since been challenged by {\em
BeppoSAX} observations. These present a more complicated behaviour for the
OVIII edge. We demonstrate here that the presence of a third, intermediate,
zone can explain all the observations. In practice, warm absorbers are likely
to be extended, multi-zone regions of which only part causes directly
observable absorption edges at any given time.