sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mols, J. P.

Normalized to: Mols, J.

8 article(s) in total. 118 co-authors, from 1 to 7 common article(s). Median position in authors list is 14,5.

[1]  oai:arXiv.org:1902.08960  [pdf] - 1890376
Precision laser-based measurements of the single electron response of SPCs for the NEWS-G light dark matter search experiment
Comments: 12 pages, 8 figures, submitted to Phys. Rev. D
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector technology employed by the NEWS-G low-mass dark matter search experiment for their high sensitivity to single electrons from ionization. In this paper, we report on the first characterization of the single electron response of SPCs with unprecedented precision, using a UV-laser calibration system. The experimental approach and analysis methodology are presented along with various direct applications for the upcoming next phase of the experiment at SNOLAB. These include the continuous monitoring of the detector response and electron drift properties during dark matter search runs, as well as the experimental measurement of the trigger threshold efficiency. We measure a mean ionization energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$ for 2.8 keV X-rays, and demonstrate the feasibility of performing similar precision measurements at sub-keV energies for future gas mixtures to be used for dark matter searches at SNOLAB.
[2]  oai:arXiv.org:1706.04934  [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at the LSM
Comments: 18 pages, 10 figures, acknowledgments section updated
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection experiment using Spherical Proportional Counters (SPCs) with light noble gases to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report the results from the first physics run taken at the Laboratoire Souterrain de Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the spin-independent WIMP-nucleon scattering cross-section in the sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times \mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5 $\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to be installed at SNOLAB by summer 2018.
[3]  oai:arXiv.org:1111.1566  [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark matter
Comments: Proceedings of the 3rd International Conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois- France- June 2011
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.
[4]  oai:arXiv.org:1109.1675  [pdf] - 1083919
Micromegas detector developments for MIMAC
Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
[5]  oai:arXiv.org:1102.3265  [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Comments: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physics
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
[6]  oai:arXiv.org:1012.1166  [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Comments: Proceedings of Identification of Dark Matter 2010-IDM2010 conference
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
[7]  oai:arXiv.org:1008.4712  [pdf] - 228441
Directional detection of non-baryonic dark matter with MIMAC
Comments: 4 pages, proc. of the 22nd Rencontres de Blois: Particle Physics and Cosmology, 15-20 July 2010, Blois, France
Submitted: 2010-08-27, last modified: 2010-09-17
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating genuine WIMP events from background ones. However, carrying out such a strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed: it is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low energy nuclei recoils obtained with a low energy neutron field are presented.
[8]  oai:arXiv.org:astro-ph/9804046  [pdf] - 100927
The CAT Imaging Telescope for Very-High-Energy Gamma-Ray Astronomy
Comments: 24 pages, 15 figures. submitted to Elsevier Preprint
Submitted: 1998-04-04
The CAT (Cherenkov Array at Themis) imaging telescope, equipped with a very-high-definition camera (546 fast phototubes with 0.12 degrees spacing surrounded by 54 larger tubes in two guard rings) started operation in Autumn 1996 on the site of the former solar plant Themis (France). Using the atmospheric Cherenkov technique, it detects and identifies very high energy gamma-rays in the range 250 GeV to a few tens of TeV. The instrument, which has detected three sources (Crab nebula, Mrk 421 and Mrk 501), is described in detail.