Normalized to: Mols, J.
[1]
oai:arXiv.org:1902.08960 [pdf] - 1890376
Precision laser-based measurements of the single electron response of
SPCs for the NEWS-G light dark matter search experiment
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Bard, J. -P.;
Brossard, A.;
Chapellier, M.;
Clark, M.;
Crawford, S.;
Corcoran, E. C.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Giroux, G.;
Gorel, P.;
Gros, M.;
Gros, P.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Knights, P.;
Langrock, S.;
Lautridou, P.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Nikolopoulos, K.;
Piquemal, F.;
Piro, M. -C.;
Santos, D.;
Savvidis, G.;
Savvidis, I.;
Fernandez, F. Vazquez de Sola;
Vidal, M.;
Zampaolo, M.
Submitted: 2019-02-24
Spherical Proportional Counters (SPCs) are a novel gaseous detector
technology employed by the NEWS-G low-mass dark matter search experiment for
their high sensitivity to single electrons from ionization. In this paper, we
report on the first characterization of the single electron response of SPCs
with unprecedented precision, using a UV-laser calibration system. The
experimental approach and analysis methodology are presented along with various
direct applications for the upcoming next phase of the experiment at SNOLAB.
These include the continuous monitoring of the detector response and electron
drift properties during dark matter search runs, as well as the experimental
measurement of the trigger threshold efficiency. We measure a mean ionization
energy of $\mathrm{W}=27.6\pm0.2~\mathrm{eV}$ in $\mathrm{Ne + CH_4}$ $(2\%)$
for 2.8 keV X-rays, and demonstrate the feasibility of performing similar
precision measurements at sub-keV energies for future gas mixtures to be used
for dark matter searches at SNOLAB.
[2]
oai:arXiv.org:1706.04934 [pdf] - 1604802
First results from the NEWS-G direct dark matter search experiment at
the LSM
Collaboration, NEWS-G;
:;
Arnaud, Q.;
Asner, D.;
Bard, J. -P.;
Brossard, A.;
Cai, B.;
Chapellier, M.;
Clark, M.;
Corcoran, E. C.;
Dandl, T.;
Dastgheibi-Fard, A.;
Dering, K.;
Di Stefano, P.;
Durnford, D.;
Gerbier, G.;
Giomataris, I.;
Gorel, P.;
Gros, M.;
Guillaudin, O.;
Hoppe, E. W.;
Kamaha, A.;
Katsioulas, I.;
Kelly, D. G.;
Martin, R. D.;
McDonald, J.;
Muraz, J. -F.;
Mols, J. -P.;
Navick, X. -F.;
Papaevangelou, T.;
Piquemal, F.;
Roth, S.;
Santos, D.;
Savvidis, I.;
Ulrich, A.;
Fernandez, F. Vazquez de Sola;
Zampaolo, M.
Submitted: 2017-06-15, last modified: 2017-09-07
New Experiments With Spheres-Gas (NEWS-G) is a direct dark matter detection
experiment using Spherical Proportional Counters (SPCs) with light noble gases
to search for low-mass Weakly Interacting Massive Particles (WIMPs). We report
the results from the first physics run taken at the Laboratoire Souterrain de
Modane (LSM) with SEDINE, a 60 cm diameter prototype SPC operated with a
mixture of $\mathrm{Ne}+\mathrm{CH}_{4}$ (0.7 %) at 3.1 bars for a total
exposure of $9.7\;\mathrm{kg\cdot days}$. New constraints are set on the
spin-independent WIMP-nucleon scattering cross-section in the
sub-$\mathrm{GeV/c^2}$ mass region. We exclude cross-sections above $4.4 \times
\mathrm{10^{-37}\;cm^2}$ at 90 % confidence level (C.L.) for a 0.5
$\mathrm{GeV/c^2}$ WIMP. The competitive results obtained with SEDINE are
promising for the next phase of the NEWS-G experiment: a 140 cm diameter SPC to
be installed at SNOLAB by summer 2018.
[3]
oai:arXiv.org:1111.1566 [pdf] - 435178
MIMAC: A micro-tpc matrix project for directional detection of dark
matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-11-07
Directional detection of non-baryonic DarkMatter is a promising search
strategy for discriminating WIMP events from background ones. This strategy
requires both a measurement of the recoil energy down to a few keV and 3D
reconstruction of tracks down to a few mm. The MIMAC project, based on a
micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first
results of a chamber prototype of this matrix, on low energy nuclear recoils
(1H and 19F) obtained with mono-energetic neutron fields are presented. The
discovery potential of this search strategy is illustrated by a realistic case
accessible to MIMAC.
[4]
oai:arXiv.org:1109.1675 [pdf] - 1083919
Micromegas detector developments for MIMAC
Ferrer-Ribas, E.;
AttiƩ, D.;
Calvet, D.;
Colas, P.;
Druillole, F.;
Giomataris, Y.;
Iguaz, F. J.;
Mols, J. P.;
Pancin, J.;
Papaevangelou, T.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-09-08, last modified: 2011-09-12
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a
directional TPC. The recent Micromegas efforts towards building a large size
detector will be described, in particular the characterization measurements of
a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout
plane. Track reconstruction with alpha particles will be shown.
[5]
oai:arXiv.org:1102.3265 [pdf] - 399526
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bouly, J. L.;
Bourrion, O.;
Fourel, Ch.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Delbart, A.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Golabek, C.;
Lebreton, L.
Submitted: 2011-02-16
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with CF4 and CHF3. The first results on low energy nuclear recoils (H, F)
obtained with a low mono-energetic neutron field are presented. The discovery
potential of this search strategy is discussed and illustrated by a realistic
case accessible to MIMAC.
[6]
oai:arXiv.org:1012.1166 [pdf] - 955699
MIMAC : A micro-tpc matrix for directional detection of dark matter
Santos, D.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Grignon, C.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Ferrer, E.;
Giomataris, I.;
Iguaz, F. J.;
Mols, J. P.;
Allaoua, A.;
Golabek, C.;
Lebreton, L.
Submitted: 2010-12-06
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from background. However, this strategy
requires both a precise measurement of the energy down to a few keV and 3D
reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC
project has been developed. It is based on a gaseous micro-TPC matrix, filled
with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H
and 19F) obtained with a low mono-energetic neutron field are presented. The
discovery potential of this search strategy is discussed and illustrated by a
realistic case accessible to MIMAC.
[7]
oai:arXiv.org:1008.4712 [pdf] - 228441
Directional detection of non-baryonic dark matter with MIMAC
Grignon, C.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Guillaudin, O.;
Mayet, F.;
Richer, J. P.;
Santos, D.;
Ferrer, E.;
Giomataris, I.;
Mols, J. P.
Submitted: 2010-08-27, last modified: 2010-09-17
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating genuine WIMP events from background ones. However,
carrying out such a strategy requires both a precise measurement of the energy
down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve
this goal, the MIMAC project has been developed: it is based on a gaseous
micro-TPC matrix, filled with 3He, CF4 and/or C4H10. Firsts results of low
energy nuclei recoils obtained with a low energy neutron field are presented.
[8]
oai:arXiv.org:astro-ph/9804046 [pdf] - 100927
The CAT Imaging Telescope for Very-High-Energy Gamma-Ray Astronomy
Barrau, A.;
Bazer-Bachi, R.;
Beyer, E.;
Cabot, H.;
Cerutti, M.;
Chounet, L. M.;
Debiais, G.;
Degrange, B.;
Delchini, H.;
Denance, J. P.;
Descotes, G.;
Dezalay, J. P.;
Djannati-Atai, A.;
Dumora, D.;
Espigat, P.;
Fabre, B.;
Fleury, P.;
Fontaine, G.;
George, R.;
Ghesquiere, C.;
Gilly, J.;
Goret, P.;
Gouiffes, C.;
Gouillaud, J. C.;
Gregory, C.;
Grenier, I. A.;
Iacoucci, L.;
Kalt, L.;
Bohec, S. Le;
Malet, I.;
Meynadier, C.;
Mols, J. P.;
de Freitas, P. Mora;
Morano, R.;
Morinaud, G.;
Munz, F.;
Palatka, M.;
Palfrey, T. A.;
Pare, E.;
Pons, Y.;
Punch, M.;
Quebert, J.;
Ragan, K.;
Renault, C.;
Rivoal, M.;
Rob, L.;
Schovanek, P.;
Smith, D.;
Tabary, A.;
Tavernet, J. P.;
Toussenel, F.;
Vrana, J.
Submitted: 1998-04-04
The CAT (Cherenkov Array at Themis) imaging telescope, equipped with a
very-high-definition camera (546 fast phototubes with 0.12 degrees spacing
surrounded by 54 larger tubes in two guard rings) started operation in Autumn
1996 on the site of the former solar plant Themis (France). Using the
atmospheric Cherenkov technique, it detects and identifies very high energy
gamma-rays in the range 250 GeV to a few tens of TeV. The instrument, which has
detected three sources (Crab nebula, Mrk 421 and Mrk 501), is described in
detail.