sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mokina, V. M.

Normalized to: Mokina, V.

6 article(s) in total. 121 co-authors, from 1 to 6 common article(s). Median position in authors list is 26,0.

[1]  oai:arXiv.org:2005.02692  [pdf] - 2090731
Cryogenic characterization of a LiAlO$_{2}$ crystal and new results on spin-dependent dark matter interactions with ordinary matter
Comments:
Submitted: 2020-05-06
In this work, a first cryogenic characterization of a scintillating LiAlO$_{2}$ single crystal is presented. The results achieved show that this material holds great potential as a target for direct dark matter search experiments. Three different detector modules obtained from one crystal grown at the Leibniz-Institut f\"ur Kristallz\"uchtung (IKZ) have been tested to study different properties at cryogenic temperatures. Firstly, two 2.8 g twin crystals were used to build different detector modules which were operated in an above-ground laboratory at the Max Planck Institute for Physics (MPP) in Munich, Germany. The first detector module was used to study the scintillation properties of LiAlO$_{2}$ at cryogenic temperatures. The second achieved an energy threshold of (213.02$\pm$1.48) eV which allows setting a competitive limit on the spin-dependent dark matter particle-proton scattering cross section for dark matter particle masses between 350 MeV/c$^{2}$ and 1.50 GeV/c$^{2}$. Secondly, a detector module with a 373 g LiAlO$_{2}$ crystal as the main absorber was tested in an underground facility at the Laboratori Nazionali del Gran Sasso (LNGS): from this measurement it was possible to determine the radiopurity of the crystal and study the feasibility of using this material as a neutron flux monitor for low-background experiments.
[2]  oai:arXiv.org:1905.07335  [pdf] - 2075555
Description of CRESST-III Data
Comments: Added appendix with information for better reproducibility
Submitted: 2019-05-17, last modified: 2020-04-06
In CRESST-III, 10 cryogenic detector modules optimized for low energy thresholds were operated for almost two years (May 2016 - February 2018). Together with this document we are publishing data from the best performing detector module which has a nuclear recoil threshold of 30.1eV. With this data-set we were able to set limits on the cross-section for spin-dependent and spin-independent elastic scattering of dark matter particles off nuclei at dark matter masses down to 160MeV/c$^2$. We publish the energies of all events after data selection as well as of all events within the acceptance region for dark-matter searches. In this document we describe how to use these data sets.
[3]  oai:arXiv.org:1902.07587  [pdf] - 2045154
First results on sub-GeV spin-dependent dark matter interactions with $^{7}$Li
Comments:
Submitted: 2019-02-20, last modified: 2019-09-04
In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li$_2$MoO$_4$ target crystal in an above-ground laboratory. Despite the high background environment, the detector sets competitive limits on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 0.8 GeV/c$^2$ and 1.5 GeV/c$^2$.
[4]  oai:arXiv.org:1908.06755  [pdf] - 2001880
Geant4-based electromagnetic background model for the CRESST dark matter experiment
Comments: 19 pages, 12 figures
Submitted: 2019-08-19
The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) dark matter search experiment aims for the detection of dark matter particles via elastic scattering off nuclei in $\mathrm{CaWO_4}$ crystals. To understand the CRESST electromagnetic background due to the bulk contamination in the employed materials, a model based on Monte Carlo simulations was developed using the Geant4 simulation toolkit. The results of the simulation are applied to the TUM40 detector module of CRESST-II phase 2. We are able to explain up to $(68 \pm 16)\,\mathrm{\%}$ of the electromagnetic background in the energy range between $1\,\mathrm{keV}$ and $40\,\mathrm{keV}$.
[5]  oai:arXiv.org:1904.00498  [pdf] - 2007901
First results from the CRESST-III low-mass dark matter program
Comments: 9 pages, 9 figures
Submitted: 2019-03-31
The CRESST experiment is a direct dark matter search which aims to measure interactions of potential dark matter particles in an earth-bound detector. With the current stage, CRESST-III, we focus on a low energy threshold for increased sensitivity towards light dark matter particles. In this manuscript we describe the analysis of one detector operated in the first run of CRESST-III (05/2016-02/2018) achieving a nuclear recoil threshold of 30.1eV. This result was obtained with a 23.6g CaWO$_4$ crystal operated as a cryogenic scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del Gran Sasso (LNGS). Both the primary phonon/heat signal and the simultaneously emitted scintillation light, which is absorbed in a separate silicon-on-sapphire light absorber, are measured with highly sensitive transition edge sensors operated at ~15mK. The unique combination of these sensors with the light element oxygen present in our target yields sensitivity to dark matter particle masses as low as 160MeV/c$^2$.
[6]  oai:arXiv.org:1304.4611  [pdf] - 653466
Astrophysical and cosmological problems of invisible mass and dark energy in the Universe
Comments: Proceedings of the Workshop on results of the Project Kosmomikrofizyka-2 (Astroparticle Physics) of the National Academy of Sciences of Ukraine, November 21-22, 2012, Institute for Nuclear Research, Kyiv, Ukraine. 94 pages, 29 figures, 5 tables (in English, Ukrainian, Russian)
Submitted: 2013-04-16
The Workshop on results of the Project Kosmomikrofizyka-2 (Astroparticle Physics) of the National Academy of Sciences (NAS) of Ukraine "Astrophysical and cosmological problems of invisible mass and dark energy in the Universe" was held on November 21-22, 2012 in the Institute for Nuclear Research, Kyiv, Ukraine (http://lpd.kinr.kiev.ua/kmf12). This Project was carried out during three years (2010-2012) by scientists from various universities and institutes of the National Academy of Sciences of Ukraine; it was a logical continuation of the previous scientific program of the NAS of Ukraine "Researches of structure and composition of the Universe, hidden mass and dark energy (Kosmomikrofizyka)" in 2007-2009. These programs were devoted to theoretical and experimental investigations in astronomy, astrophysics, cosmology, physics of atomic nuclei and particle physics, which are related with the problems of dark matter and dark energy in the Universe.