sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mizumoto, T.

Normalized to: Mizumoto, T.

17 article(s) in total. 120 co-authors, from 1 to 10 common article(s). Median position in authors list is 5,0.

[1]  oai:arXiv.org:1703.07600  [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an Electron-Tracking Compton Camera
Comments: 22 pages, 19 figures, 1 table, accepted for publication in ApJ
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging polarimeter. The ETCC provides powerful background rejection and a high modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging based on a well-defined point spread function. Importantly, we demonstrated for the first time the stability of the modulation factor under realistic conditions of off-axis incidence and huge backgrounds using the SPring-8 polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$ 0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$ and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis incidence. These measured results are consistent with the simulation results. Consequently, we found that the satellite-ETCC proposed in Tanimori et al. (2015) would provide all-sky surveys of weak persistent sources of 13 mCrab with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a $6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year observation.
[2]  oai:arXiv.org:1702.01484  [pdf] - 1535426
First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant
Comments: 19 pages, 7 figures, 2 tables
Submitted: 2017-02-05
We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in the vicinity of the Fukushima Daiichi Nuclear Power Plants in Japan in 2014. The obtained distribution of brightness (or emissivity) with remote-sensing observations is unambiguously converted into the dose distribution. We confirm that the dose distribution is consistent with the one taken by conventional mapping measurements with a dosimeter physically placed at each grid point. Furthermore, its imaging spectroscopy, boosted by Compton-edge-free spectra, reveals complex radioactive features in a quantitative manner around each individual target point in the background-dominated environment. Notably, we successfully identify a "micro hot spot" of residual caesium contamination even in an already decontaminated area. These results show that the ETCC performs exactly as the geometrical optics predicts, demonstrates its versatility in the field radiation measurement, and reveals potentials for application in many fields, including the nuclear industry, medical field, and astronomy.
[3]  oai:arXiv.org:1702.01483  [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Comments: 22 pages, 8 figures
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
[4]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[5]  oai:arXiv.org:1508.00990  [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Comments: 11 pages, 24 figures
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
[6]  oai:arXiv.org:1508.01287  [pdf] - 1259555
A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation
Comments: 10 pages, 7 figures, proceeding of the 10th International Conference on Position Sensitive Detectors (PSD10)
Submitted: 2015-08-06
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;\mu\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$\sigma$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
[7]  oai:arXiv.org:1507.03850  [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Comments: 19 pages, 12 figures, Accepted to the Astrophysical Journal
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
[8]  oai:arXiv.org:1412.3918  [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Comments: 10 pages, 8figures, http://www-cr.scphys.kyoto-u.ac.jp/research/MeV-gamma/wiki/wiki.cgi , PSD10
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
[9]  oai:arXiv.org:1312.0438  [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Comments: 9 pages, 7 figures, Proceedings of the 15th International Workshop on Radiation Imaging Detectors (iWoRiD 2013)
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
[10]  oai:arXiv.org:1302.1000  [pdf] - 691203
Experimental search for solar hidden photons in the eV energy range using kinetic mixing with photons
Comments: 11 pages, 4 figures. To be submitted to JCAP. Added fig.2. Added references to some recent theoretical developments. Added results of new references to the exclusion plot(fig.5). Our results remain unchanged
Submitted: 2013-02-05, last modified: 2013-06-18
We have searched for solar hidden photons in the eV energy range using a dedicated hidden photon detector. The detector consisted of a parabolic mirror with a diameter of 500mm and a focal length of 1007mm installed in a vacuum chamber, and a photomultiplier tube at its focal point. The detector was attached to the Tokyo axion helioscope, Sumico which has a mechanism to track the sun. From the result of the measurement, we found no evidence for the existence of hidden photons and set a limit on the photon-hidden photon mixing parameter \chi depending on the hidden photon mass m_{\gamma '}.
[11]  oai:arXiv.org:1201.4622  [pdf] - 467136
The Tokyo Axion Helioscope
Comments:
Submitted: 2012-01-22
The Tokyo Axion Helioscope experiment aims to detect axions which are produced in the solar core. The helioscope uses a strong magnetic field in order to convert axions into X-ray photons and has a mounting to follow the sun very accurately. The photons are detected by an X-ray detector which is made of 16 PIN-photodiodes. In addition, a gas container and a gas regulation system is adopted for recovering the coherence between axions and photons in the conversion region giving sensitivity to axions with masses up to 2 eV. In this paper, we report on the technical detail of the Tokyo Axion Helioscope.
[12]  oai:arXiv.org:1109.3099  [pdf] - 1084087
NEWAGE
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-09-14, last modified: 2011-09-15
NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the detector components with radio-pure materials. We also studied the possibilities of head-tail recognition of nuclear tracks in the surface laboratory. For the future large volume detector, we are developing a pixel ASIC named QPIX. In this paper, these recent R&D activities are described.
[13]  oai:arXiv.org:1002.0468  [pdf] - 33408
Tokyo axion helioscope experiment
Comments: 5 pages, 4 figures. Identification of dark matter 2008 (idm2008), August 18-22, 2008, Stockholm, Sweden
Submitted: 2010-02-02
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m x 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. In the past measurements, axion mass up to 0.27eV have been scanned. It has been upgraded to handle dispersion-matching gas (He-4) of higher density to explore higher mass region. From December 2007 through April 2008, the axion mass region 0.84 < m < 1.00eV was newly explored, where the axions in the "photon-coupling vs. mass" parameter region of the preferred axion models were newly searched. From the absence of any evidence, a limit on axion-photon coupling constant was set to be g < 5.6-13.4e-10/GeV at 95% confidence level in the above mass region.
[14]  oai:arXiv.org:0911.0738  [pdf] - 30267
Prospects of Search for Solar Axions with Mass over 1 eV and Hidden Sector Photons
Comments: 4 pages, 5 figures, contribution to 5th Patras Workshop on Axions, WIMPs and WISPs, Durham, UK, 13-17 July 2009
Submitted: 2009-11-04
We present prospects of two experiments using the Tokyo Axion Helioscope. One is a search for solar axions. In the past measurements, axion mass from 0 to 0.27 eV and from 0.84 to 1.00 eV have been scanned and no positive evidence was seen. We are now actively preparing a new phase of the experiment aiming at axion mass over 1 eV. The other is a search for hidden sector photons from the Sun. We have been designing and testing some additional equipments, which have to be installed on the helioscope to search for hidden photons with mass of over $10^{-3}$ eV.
[15]  oai:arXiv.org:0809.0596  [pdf] - 15935
Tokyo Axion Helioscope
Comments: 4th Patras Workshop on Axions, WIMPs and WISPs
Submitted: 2008-09-03
A new search result of the Tokyo axion helioscope is presented. The axion helioscope consists of a dedicated cryogen-free 4T superconducting magnet with an effective length of 2.3 m and PIN photodiodes as x-ray detectors. Solar axions, if exist, would be converted into X-ray photons through the inverse Primakoff process in the magnetic field. Conversion is coherently enhanced even for massive axions by filling the conversion region with helium gas. The present third phase measurement sets a new limit of g_{a\gamma\gamma}<(5.6--13.4)\times10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.0 eV at 95% confidence level.
[16]  oai:arXiv.org:0806.2230  [pdf] - 369033
Search for solar axions with mass around 1 eV using coherent conversion of axions into photons
Comments: 13 pages, 6 figures, to be published in PLB
Submitted: 2008-06-13, last modified: 2008-08-26
A search for solar axions has been performed using an axion helioscope which is equipped with a 2.3m-long 4T superconducting magnet, a gas container to hold dispersion-matching gas, PIN-photodiode X-ray detectors, and a telescope mount mechanism to track the sun. A mass region around m_a = 1eV was newly explored. From the absence of any evidence, analysis sets a limit on axion-photon coupling constant to be g < 5.6-13.4x10^{-10} GeV^{-1} for the axion mass of 0.84<m_a<1.00eV at 95% confidence level. It is the first result to search for the axion in the g-m_a parameter region of the preferred axion models with a magnetic helioscope.
[17]  oai:arXiv.org:0806.1471  [pdf] - 341922
Status report of the Tokyo axion helioscope experiment
Comments: 3 pages, 3 figures, submitted to be included in the proceedings of TAUP 2007
Submitted: 2008-06-09
We have searched for solar axions with a detector which consists of a 4T x 2.3m superconducting magnet, PIN-photodiode X-ray detectors, and an altazimuth mount to track the sun. The conversion region is filled with cold helium gas which modifies the axion mass at which coherent conversion occurs. In the past measurements, axion mass from 0 to 0.27eV have been scanned. Since no positive evidence was seen, an upper limit to the axion-photon coupling constant was set to be g < 6-10E-10/GeV (95%CL) depending on the axion masses. We are now actively preparing for a new stage of the experiment aiming at one to a few eV solar axions. In this mass region, our detector might be able to check parameter regions which are preferable to the axion models.