Normalized to: Miyamoto, S.
[1]
oai:arXiv.org:1706.06483 [pdf] - 1584925
Performance measurement of HARPO: a Time Projection Chamber as a
gamma-ray telescope and polarimeter
Gros, P.;
Amano, S.;
Attié, D.;
Baron, P.;
Baudin, D.;
Bernard, D.;
Bruel, P.;
Calvet, D.;
Colas, P.;
Daté, S.;
Delbart, A.;
Frotin, M.;
Geerebaert, Y.;
Giebels, B.;
Götz, D.;
Hashimoto, S.;
Horan, D.;
Kotaka, T.;
Louzir, M.;
Magniette, F.;
Minamiyama, Y.;
Miyamoto, S.;
Ohkuma, H.;
Poilleux, P.;
Semeniouk, I.;
Sizun, P.;
Takemoto, A.;
Yamaguchi, M.;
Yonamine, R.;
Wang, S.
Submitted: 2017-06-20, last modified: 2017-08-30
We analyse the performance of a gas time projection chamber (TPC) as a
high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair
creation regime. We use data collected at a gamma-ray beam of known
polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$
of the tracks induced by each conversion in the gas volume. We use a simple
vertex finder in which vertices and pseudo-tracks exiting from them are
identified.
We study the various contributions to the single-photon angular resolution
using Monte Carlo simulations and compare them with the experimental data and
find that they are in excellent agreement. The distribution of the azimutal
angle of pair conversions shows a bias due to the non-cylindrical-symmetric
structure of the detector. This bias would average out for a long duration
exposure on a space mission, but for this pencil-beam characterisation we have
ensured its accurate simulation by a double systematics control scheme, data
taking with the detector rotated at several angles with respect to the beam
polarisation direction and systematics control with a non-polarised beam.
We measure, for the first time, the polarisation asymmetry of a linearly
polarised gamma-ray beam in the low energy pair creation regime. This sub-GeV
energy range is critical for cosmic sources as their spectra are power laws
which fall quickly as a function of increasing energy.
This work could pave the way to extending polarised gamma-ray astronomy
beyond the MeV energy regime.
[2]
oai:arXiv.org:1703.07600 [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an
Electron-Tracking Compton Camera
Komura, Shotaro;
Takada, Atsushi;
Mizumura, Yoshitaka;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tanimori, Toru;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and
the magnetic configuration of various celestial objects, such as binary black
holes or gamma-ray bursts (GRBs). However, statistically significant
polarizations have been detected in few of the brightest objects. Even though
future polarimeters using X-ray telescopes are expected to observe weak
persistent sources, there are no effective approaches to survey transient and
serendipitous sources with a wide field of view (FoV). Here we present an
electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging
polarimeter. The ETCC provides powerful background rejection and a high
modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging
based on a well-defined point spread function. Importantly, we demonstrated for
the first time the stability of the modulation factor under realistic
conditions of off-axis incidence and huge backgrounds using the SPring-8
polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$
0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$
and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis
incidence. These measured results are consistent with the simulation results.
Consequently, we found that the satellite-ETCC proposed in Tanimori et al.
(2015) would provide all-sky surveys of weak persistent sources of 13 mCrab
with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a
$6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year
observation.
[3]
oai:arXiv.org:1702.01483 [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on
Geometrical Optics
Tanimori, Toru;
Mizumura, Yoshitaka;
Takada, Atsushi;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Komura, Shotaro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to
pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does
not keep physical information (intensity, or brightness in Optics) along a ray,
and thus is capable of no more than qualitative imaging of bright objects. To
attain quantitative imaging, cameras that realize geometrical optics is
essential, which would be, for nuclear MeV gammas, only possible via complete
reconstruction of the Compton process. Recently we have revealed that "Electron
Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function
(PSF). The information of an incoming gamma is kept along a ray with the PSF
and that is equivalent to geometrical optics. Here we present an
imaging-spectroscopic measurement with the ETCC. Our results highlight the
intrinsic difficulty with CCs in performing accurate imaging, and show that the
ETCC surmounts this problem. The imaging capability also helps the ETCC
suppress the noise level dramatically by ~3 orders of magnitude without a
shielding structure. Furthermore, full reconstruction of Compton process with
the ETCC provides spectra free of Compton edges. These results mark the first
proper imaging of nuclear gammas based on the genuine geometrical optics.
[4]
oai:arXiv.org:1606.09417 [pdf] - 1479435
First measurement of polarisation asymmetry of a gamma-ray beam between
1.74 to 74 MeV with the HARPO TPC
Gros, Philippe;
Amano, Sho;
Attié, David;
Bernard, Denis;
Bruel, Philippe;
Calvet, Denis;
Colas, Paul;
Daté, Schin;
Delbart, Alain;
Frotin, Mickael;
Geerebaert, Yannick;
Giebels, Berrie;
Götz, Diego;
Hashimoto, S.;
Horan, Deirdr;
Kotaka, T.;
Louzir, Marc;
Minamiyama, Y.;
Miyamoto, Shuji;
Ohkuma, H.;
Poilleux, Patrick;
Semeniouk, Igor;
Sizun, Patrick;
Takemoto, A.;
Yamaguchi, M.;
Wang, Shaobo
Submitted: 2016-06-30
Current $\gamma$-ray telescopes suffer from a gap in sensitivity in the
energy range between 100keV and 100MeV, and no polarisation measurement has
ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair
telescopes are limited at lower energies by the multiple scattering of
electrons in passive tungsten converter plates. This results in low angular
resolution, and, consequently, a drop in sensitivity to point sources below
1GeV. The polarisation information, which is carried by the azimuthal angle of
the conversion plane, is lost for the same reasons.
HARPO (Hermetic ARgon POlarimeter) is an R\&D program to characterise the
operation of a gaseous detector (a Time Projection Chamber or TPC) as a high
angular-resolution and sensitivity telescope and polarimeter for $\gamma$ rays
from cosmic sources. It represents a first step towards a future space
instrument in the MeV-GeV range.
We built and characterised a 30cm cubic demonstrator [SPIE 91441M], and put
it in a polarised $\gamma$-ray beam at the NewSUBARU accelerator in Japan. Data
were taken at photon energies from 1.74MeV to 74MeV, and with different
polarisation configurations.
We describe the experimental setup in beam. We then describe the software we
developed to reconstruct the photon conversion events, with special focus on
low energies. We also describe the thorough simulation of the detector used to
compare results. Finally we will present the performance of the detector as
extracted from this analysis and preliminary measurements of the polarisation
asymmetry.
This beam-test qualification of a gas TPC prototype in a $\gamma$-ray beam
could open the way to high-performance $\gamma$-ray astronomy and polarimetry
in the MeV-GeV energy range in the near future.
[5]
oai:arXiv.org:1603.06817 [pdf] - 1432235
Measurement of 1.7 to 74 MeV polarised gamma rays with the HARPO TPC
Geerebaert, Y.;
Gros, Ph.;
Amano, S.;
Attié, D.;
Bernard, D.;
Bruel, P.;
Calvet, D.;
Colas, P.;
Daté, S.;
Delbart, A.;
Frotin, M.;
Giebels, B.;
Götz, D.;
Hashimoto, S.;
Horan, D.;
Kotaka, T.;
Louzir, M.;
Minamiyama, Y.;
Miyamoto, S.;
Ohkuma, H.;
Poilleux, P.;
Semeniouk, I.;
Sizun, P.;
Takemoto, A.;
Yamaguchi, M.;
Wang, S.
Submitted: 2016-03-22
Current {\gamma}-ray telescopes based on photon conversions to
electron-positron pairs, such as Fermi, use tungsten converters. They suffer of
limited angular resolution at low energies, and their sensitivity drops below 1
GeV. The low multiple scattering in a gaseous detector gives access to higher
angular resolution in the MeV-GeV range, and to the linear polarisation of the
photons through the azimuthal angle of the electron-positron pair.
HARPO is an R&D program to characterise the operation of a TPC (Time
Projection Chamber) as a high angular-resolution and sensitivity telescope and
polarimeter for {\gamma} rays from cosmic sources. It represents a first step
towards a future space instrument. A 30 cm cubic TPC demonstrator was built,
and filled with 2 bar argon-based gas. It was put in a polarised {\gamma}-ray
beam at the NewSUBARU accelerator in Japan in November 2014. Data were taken at
different photon energies from 1.7 MeV to 74 MeV, and with different
polarisation configurations. The electronics setup is described, with an
emphasis on the trigger system. The event reconstruction algorithm is quickly
described, and preliminary measurements of the polarisation of 11 MeVphotons
are shown.
[6]
oai:arXiv.org:1508.00990 [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton
camera for MeV gamma-ray astronomy (SMILE-II)
Mizumoto, Tetsuya;
Matsuoka, Yoshihiro;
Mizumura, Yoshitaka;
Tanimori, Toru;
Kubo, Hidetoshi;
Takada, Atsushi;
Iwaki, Satoru;
Sawano, Tatsuya;
Nakamura, Kiseki;
Komura, Shotaro;
Nakamura, Shogo;
Kishimoto, Tetsuro;
Oda, Makoto;
Miyamoto, Shohei;
Takemura, Taito;
Parker, Joseph D.;
Tomono, Dai;
Sonoda, Shinya;
Miuchi, Kentaro;
Kurosawa, Shunsuke
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton
camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation
background and attaining the high sensitivity of near 1 mCrab in space. Our
ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas
detector for tracking recoil electrons and a position-sensitive scintillation
camera for detecting scattered gamma rays. After the success of a first balloon
experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$
TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV
gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$
medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial
sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II).
To achieve this goal, a 100-times-larger detection area compared with that of
SMILE-I is required without changing the weight or power consumption of the
detector system. In addition, the event rate is also expected to dramatically
increase during observation. Here, we describe both the concept and the
performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to
manage 100 times more data while satisfying the severe restrictions regarding
the weight and power consumption imposed by a balloon-borne observation. In
particular, to improve the detection efficiency of the fine tracks in the TPC
from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in
the TPC. Therefore, for efficient management of such large amounts of data, we
developed a data-acquisition system with parallel data flow.
[7]
oai:arXiv.org:1507.03850 [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe
by MeV gamma-rays
Tanimori, T.;
Kubo, H.;
Takada, A.;
Iwaki, S.;
Komura, S.;
Kurosawa, S.;
Matsuoka, Y.;
Miuchi, K.;
Miyamoto, S.;
Mizumoto, T.;
Mizumura, Y.;
Nakamura, K.;
Nakamura, S.;
Oda, M.;
Parker, J. D.;
Sawano, T.;
Sonoda, S.;
Takemura, T.;
Tomono, D.;
Ueno, K.
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge
backgrounds and unclearness in images, which are originated from incompleteness
in determining the physical parameters of Compton scattering in detection,
e.g., lack of the directional information of the recoil electrons. The recent
major mission/instrument in the MeV band, Compton Gamma Ray
Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$
persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV
band. Here we report the performance of an Electron-Tracking Compton Camera
(ETCC), and prove that it has a good potential to break through this stagnation
in MeV gamma-ray astronomy. The ETCC provides all the parameters of
Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter
Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx),
which CCs cannot measure, is also obtained, and is found to be indeed helpful
to reduce the background under conditions similar to space. Accordingly the
significance in gamma detection is improved severalfold. On the other hand, SPD
is essential to determine the point-spread function (PSF) quantitatively. The
SPD resolution is improved close to the theoretical limit for multiple
scattering of recoil electrons. With such a well-determined PSF, we demonstrate
for the first time that it is possible to provide reliable sensitivity in
Compton imaging without utilizing an optimization algorithm. As such, this
study highlights the fundamental weak-points of CCs. In contrast we demonstrate
the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg
cm$^{-2}$ s$^{-1}$ at 1 MeV.
[8]
oai:arXiv.org:1503.03772 [pdf] - 1323356
HARPO: beam characterization of a TPC for gamma-ray polarimetry and high
angular-resolution astronomy in the MeV-GeV range
Wang, Shaobo;
Bernard, Denis;
Bruel, Philippe;
Frotin, Mickael;
Geerebaert, Yannick;
Giebels, Berrie;
Gros, Philippe;
Horan, Deirdre;
Louzir, Marc;
Poilleux, Patrick;
Semeniouk, Igor;
Attié, David;
Calvet, Denis;
Colas, Paul;
Delbart, Alain;
Sizun, Patrick;
Götz, Diego;
Amano, Sho;
Kotaka, Takuya;
Hashimoto, Satoshi;
Minamiyama, Yasuhito;
Takemoto, Akinori;
Yamaguchi, Masashi;
Miyamoto, Shuji;
Daté, Schin;
Ohkuma, Haruo
Submitted: 2015-03-12
A time projection chamber (TPC) can be used to measure the polarization of
gamma rays with excellent angular precision and sensitivity in the MeV-GeV
energy range through the conversion of photons to e+e- pairs. The Hermetic
ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It
was recently tested in the polarized photon beam at the NewSUBARU facility in
Japan. We present this data-taking run, which demonstrated the excellent
performance of the HARPO TPC.
[9]
oai:arXiv.org:1412.3918 [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense
radiations from a water target irradiated with a proton beam
Matsuoka, Yoshihiro;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Mizumura, Y.;
Iwaki, S.;
Sawano, T.;
Komura, S.;
Kishimoto, T.;
Oda, M.;
Takemura, T.;
Miyamoto, S.;
Sonoda, S.;
Tomono, D.;
Miuchi, K.;
Kabuki, S.;
Kurosawa, S.
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in
next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time
projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC
measures the three dimensional tracks of Compton-recoil electrons, the ETCC can
completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates
efficient background rejection power in Compton-kinematics tests, identifies
particle from the energy deposit rate (dE/dX) registered in the TPC, and
provides high quality imaging by completely reconstructing the Compton
scattering process. We are planning the "Sub-MeV gamma ray Imaging
Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey
satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for
observing the Crab nebula, are ongoing. However, observations at balloon
altitudes or satellite orbits are obstructed by radiation background from the
atmosphere and the detector itself. The background rejection power was checked
using proton accelerator experiments conducted at the Research Center for
Nuclear Physics, Osaka University. To create the intense radiation fields
encountered in space, which comprise gamma rays, neutrons, protons, and other
energetic entities, we irradiated a water target with a 140 MeV proton beam and
placed a SMILE-II ETCC near the target. In this situation, the counting rate
was five times than that expected at the balloon altitude. Nonetheless, the
ETCC stably operated and identified particles sufficiently to obtain a clear
gamma ray image of the checking source. Here, we report the performance of our
detector and demonstrate its effective background rejection based in electron
tracking experiments.
[10]
oai:arXiv.org:1202.2529 [pdf] - 475837
Balloon-borne gamma-ray telescope with nuclear emulsion : overview and
status
Aoki, Shigeki;
Fukuda, Tsutomu;
Hamada, Kaname;
Hara, Toshio;
Iyono, Atsushi;
Kawada, Jiro;
Kazuyama, Masashi;
Kodama, Koichi;
Komatsu, Masahiro;
Koshiba, Shinichiro;
Kubota, Hirotaka;
Miyamoto, Seigo;
Miyanishi, Motoaki;
Morishima, Kunihiro;
Naganawa, Naotaka;
Naka, Tatsuhiro;
Nakamura, Mitsuhiro;
Nakano, Toshiyuki;
Niwa, Kimio;
Nonoyama, Yoshiaki;
Ozaki, Keita;
Rokujo, Hiroki;
Sako, Takashi;
Sato, Osamu;
Sato, Yoshihiro;
Suzuki, Atsumu;
Suzuki, Kazuya;
Takahashi, Satoru;
Tezuka, Ikuo;
Yoshida, Junya;
Yoshioka, Teppei
Submitted: 2012-02-12
Detecting the first electron pairs with nuclear emulsion allows a precise
measurement of the direction of incident gamma-rays as well as their
polarization. With recent innovations in emulsion scanning, emulsion analyzing
capability is becoming increasingly powerful. Presently, we are developing a
balloon-borne gamma-ray telescope using nuclear emulsion. An overview and a
status of our telescope is given.