sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Miuchi, Kentaro

Normalized to: Miuchi, K.

45 article(s) in total. 646 co-authors, from 1 to 30 common article(s). Median position in authors list is 15,0.

[1]  oai:arXiv.org:2006.09721  [pdf] - 2124928
Observation of Excess Electronic Recoil Events in XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Angevaare, J. R.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Cimmino, B.; Clark, M.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; Depoian, A.; Di Gangi, P.; Di Giovanni, A.; Di Stefano, R.; Diglio, S.; Elykov, A.; Eurin, G.; Ferella, A. D.; Fulgione, W.; Gaemers, P.; Gaior, R.; Galloway, M.; Gao, F.; Grandi, L.; Hasterok, C.; Hils, C.; Hiraide, K.; Hoetzsch, L.; Howlett, J.; Iacovacci, M.; Itow, Y.; Joerg, F.; Kato, N.; Kazama, S.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Long, J.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Mancuso, A.; Manenti, L.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Martens, K.; Masbou, J.; Masson, D.; Mastroianni, S.; Messina, M.; Miuchi, K.; Mizukoshi, K.; Molinario, A.; Morå, K.; Moriyama, S.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Plante, G.; Qin, J.; Qiu, H.; García, D. Ramírez; Reichard, S.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Semeria, F.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Takeda, A.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Vargas, M.; Volta, G.; Wang, H.; Wei, Y.; Weinheimer, C.; Weiss, M.; Wenz, D.; Wittweg, C.; Xu, Z.; Yamashita, M.; Ye, J.; Zavattini, G.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.; Mougeot, X.
Comments: 24 pages, 15 figures, v2 added Ar37 background discussion and best-fit mass of bosonic dark matter, data upload fig 2,4,15 in 10.5281/zenodo.3924406
Submitted: 2020-06-17, last modified: 2020-06-30
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector, with an exposure of 0.65 t-y and an unprecedentedly low background rate of $76 \pm 2_{stat}$ events/(t y keV) between 1-30 keV. An excess over known backgrounds is observed below 7 keV, rising towards lower energies and prominent between 2-3 keV. The solar axion model has a 3.5$\sigma$ significance, and a three-dimensional 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae} < 3.7 \times 10^{-12}$, $g_{ae}g_{an}^{eff} < 4.6 \times 10^{-18}$, and $g_{ae}g_{a\gamma} < 7.6\times10^{-22}~{GeV}^{-1}$, and excludes either $g_{ae}=0$ or $g_{ae}g_{a\gamma}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic moment signal is similarly favored over background at 3.2$\sigma$ and a confidence interval of $\mu_{\nu} \in (1.4,~2.9)\times10^{-11}\mu_B$ (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by $\beta$ decays of tritium at 3.2$\sigma$ significance with a corresponding tritium concentration in xenon of $(6.2 \pm 2.0) \times 10^{-25}$ mol/mol. Such a trace amount can be neither confirmed nor excluded with current knowledge of production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are decreased to 2.1$\sigma$ and 0.9$\sigma$, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ($2.3 \pm 0.2$) keV (68% C.L.) with a 3.0$\sigma$ global (4.0$\sigma$ local) significance over background. This analysis sets the most restrictive direct constraints to date on pseudoscalar and vector bosonic dark matter for most masses between 1 and 210 keV/c$^2$.
[2]  oai:arXiv.org:2005.11891  [pdf] - 2112667
Search for exotic neutrino-electron interactions using solar neutrinos in XMASS-I
Comments:
Submitted: 2020-05-24
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three species of neutrino have common millicharge. We also set flavor dependent limits assuming the respective neutrino flavor is the only one carrying a millicharge, $7.3 \times 10^{-12} e$ for $\nu_e$, $1.1 \times 10^{-11} e$ for $\nu_{\mu}$, and $1.1 \times 10^{-11} e$ for $\nu_{\tau}$. These limits are the most stringent yet obtained from direct measurements. We also obtain an upper limit for the neutrino magnetic moment of 1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for the coupling constant of dark photons in the $U(1)_{B-L}$ model of 1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$, and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
[3]  oai:arXiv.org:2004.09706  [pdf] - 2081177
Development of a Negative Ion Micro TPC Detector with SF$_{6}$ Gas for the Directional Dark Matter Search
Comments:
Submitted: 2020-04-20
A negative ion micro time projection chamber (NI$\mu$TPC) was developed and its performance studied. An NI$\mu$TPC is a novel technology that enables the measurement of absolute $z$ coordinates for self-triggering TPCs. This technology provides full-fiducialization analysis, which is not possible with conventional gaseous TPCs, and is useful for directional dark matter searches in terms of background rejection and the improvement of the angular resolution. The developed NI$\mu$TPC prototype had a detection volume of 12.8 $\times$ 25.6 $\times$ 144 mm$^{3}$. The absolute $z$ coordinate was determined with a location accuracy of 16 mm using minority carrieres of SF$_{5}^{-}$. Simultaneously, there was a successful reconstruction of the three-dimensional (3D) tracks with a spatial resolution of 130 $\mu\rm{m}$. This is the first demonstration of 3D tracking with the detection of absolute $z$ coordinates, and it is an important step in improving the sensitivity of directional dark matter searches.
[4]  oai:arXiv.org:1707.05523  [pdf] - 2073943
Discrimination of anisotropy in dark matter velocity distribution with directional detectors
Comments: 19 pages, 34 figures
Submitted: 2017-07-18, last modified: 2020-04-01
Directional detection of dark matter has sensitivity for both recoil energy and direction of nuclear recoil. It opens the way to measure local velocity distribution of dark matter. In this paper, we study possibility to discriminate isotropic distribution and anisotropic one suggested by a N-body simulation with directional detector. Numerical simulation is performed for two cases according to the detectors, one corresponds to angular histogram and the other is energy-angular distribution of the signals. We reveal that the anisotropy of velocity distribution can be discriminated at 90% C.L. with chi-squared test if O($10^4$) signals are obtained.
[5]  oai:arXiv.org:2003.03825  [pdf] - 2060953
Energy resolution and linearity in the keV to MeV range measured in XENON1T
Aprile, E.; Aalbers, J.; Agostini, F.; Alfonsi, M.; Althueser, L.; Amaro, F. D.; Antochi, V. C.; Angelino, E.; Angevaare, J.; Arneodo, F.; Barge, D.; Baudis, L.; Bauermeister, B.; Bellagamba, L.; Benabderrahmane, M. L.; Berger, T.; Breur, P. A.; Brown, A.; Brown, E.; Bruenner, S.; Bruno, G.; Budnik, R.; Capelli, C.; Cardoso, J. M. R.; Cichon, D.; Cimmino, B.; Clark, M.; Coderre, D.; Colijn, A. P.; Conrad, J.; Cussonneau, J. P.; Decowski, M. P.; Di Stefano, A. Depoian P. Di Gangi A. Di Giovanni R.; Diglio, S.; Elykov, A.; Eurin, G.; Ferella, A. D.; Fulgione, W.; Gaemers, P.; Gaior, R.; Rosso, A. Gallo; Galloway, M.; Gao, F.; Garbini, M.; Grandi, L.; Hasterok, C.; Hils, C.; Hiraide, K.; Hoetzsch, L.; Hogenbirk, E.; Howlett, J.; Iacovacci, M.; Itow, Y.; Joerg, F.; Kato, N.; Kazama, S.; Kobayashi, M.; Koltman, G.; Kopec, A.; Landsman, H.; Lang, R. F.; Levinson, L.; Lin, Q.; Lindemann, S.; Lindner, M.; Lombardi, F.; Lopes, J. A. M.; Fune, E. López; Macolino, C.; Mahlstedt, J.; Manenti, L.; Manfredini, A.; Marignetti, F.; Undagoitia, T. Marrodán; Martens, K.; Masbou, J.; Masson, D.; Mastroianni, S.; Messina, M.; Miuchi, K.; Molinario, A.; Morå, K.; Moriyama, S.; Mosbacher, Y.; Murra, M.; Naganoma, J.; Ni, K.; Oberlack, U.; Odgers, K.; Palacio, J.; Pelssers, B.; Peres, R.; Pienaar, J.; Pizzella, V.; Qin, G. Plante J.; Qiu, H.; García, D. Ramírez; Reichard, S.; Rocchetti, A.; Rupp, N.; Santos, J. M. F. dos; Sartorelli, G.; Šarčević, N.; Scheibelhut, M.; Schindler, S.; Schreiner, J.; Schulte, D.; Schumann, M.; Lavina, L. Scotto; Selvi, M.; Semeria, F.; Shagin, P.; Shockley, E.; Silva, M.; Simgen, H.; Takeda, A.; Therreau, C.; Thers, D.; Toschi, F.; Trinchero, G.; Tunnell, C.; Vargas, M.; Volta, G.; Wack, O.; Wang, H.; Wei, Y.; Weinheimer, C.; Xu, M. Weiss; Wenz, D.; Wittweg, C.; Wulf, J.; Xu, Z.; Yamashita, M.; Ye, J.; Zavattini, G.; Zhang, Y.; Zhu, T.; Zopounidis, J. P.
Comments: 9 pages, 7 figures
Submitted: 2020-03-08
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{\beta\beta}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $\sigma/\mu$ is as low as (0.79$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{\beta\beta}$. We achieve this by using a signal correction method to rectify the saturation effects of the signal readout system. The very good energy resolution from keV to MeV energies demonstrated in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
[6]  oai:arXiv.org:1903.04843  [pdf] - 2056762
Probing GHz Gravitational Waves with Graviton-magnon Resonance
Comments: 5 pages, 1 figure, minor changes
Submitted: 2019-03-12, last modified: 2020-03-02
A novel method for extending frequency frontier in gravitational wave observations is proposed. It is shown that gravitational waves can excite a magnon. Thus, gravitational waves can be probed by a graviton-magnon detector which measures resonance fluorescence of magnons. Searching for gravitational waves with a wave length $\lambda$ by using a ferromagnetic sample with a dimension $l$, the sensitivity of the graviton-magnon detector reaches spectral densities, around $5.4 \times 10^{-22} \times (\frac{l}{\lambda /2\pi})^{-2} \ [{\rm Hz}^{-1/2}]$ at 14 GHz and $8.6 \times 10^{-21} \times (\frac{l}{\lambda /2\pi})^{-2} \ [{\rm Hz}^{-1/2}]$ at 8.2 GHz, respectively.
[7]  oai:arXiv.org:1903.01090  [pdf] - 2038205
Development of an alpha-particle imaging detector based on a low radioactivity micro-time-projection chamber
Comments: Accept 25 Oct 2019, Nucl. Instr. Meth. A
Submitted: 2019-03-04, last modified: 2019-10-30
An important issue for rare-event-search experiments, such as the search for dark matter or neutrinoless double beta decay, is to reduce radioactivity of the detector materials and the experimental environment. The selection of materials with low radioactive impurities, such as isotopes of the uranium and thorium chains, requires a precise measurement of surface and bulk radioactivity. Focused on the first one, an alpha-particle detector has been developed based on a gaseous micro-time-projection chamber. A low-alpha mu-PIC with reduced alpha-emission background was installed in the detector. The detector offers the advantage of position sensitivity, which allows the alpha-particle contamination of the sample to be imaged and the background to be measured at the same time. The detector performance was measured by using an alpha-particle source. The measurement with a sample was also demonstrated and the sensitivity is discussed.
[8]  oai:arXiv.org:1907.12729  [pdf] - 1925210
MPGD simulation in negative-ion gas for direction-sensitive dark matter searches
Comments: MPGD2019 proceedings, 8 pages, 11 figures
Submitted: 2019-07-30
Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark mater searches. The characteristics of micro pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both experiments and simulations to develop an NITPC for dark matter search experiments. An MPGD simulation method for the negative-ion gas with Garfield++, which has not yet been established, was developed. We present herein the MPGD simulation results in negative-ion gas, $\mathrm{SF_{6}}$ gas, together with the experimental results, such as gain, energy resolution, and signal creation from the MPGD for future NITPC optimization.
[9]  oai:arXiv.org:1809.05358  [pdf] - 1851548
Search for WIMP-$^{129}$Xe inelastic scattering with particle identification in XMASS-I
Comments: 8 pages, 10 figures
Submitted: 2018-09-14, last modified: 2019-03-19
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classification based on scintillation timing that distinguished $\gamma$-rays and $\beta$-rays, and simultaneous fitting of the energy spectra of $\gamma$-like and $\beta$-like samples. No evidence of a WIMP signal was found. Thus, we set the upper limits of the inelastic channel cross section at 90\% confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\; {\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm GeV}/c^2$ than the existing experimental limit.
[10]  oai:arXiv.org:1808.03617  [pdf] - 1822844
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Comments: 7 pages, 3 figures
Submitted: 2018-08-10, last modified: 2019-01-29
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
[11]  oai:arXiv.org:1804.02180  [pdf] - 1806000
A direct dark matter search in XMASS-I
Comments: 16 pages, 8 figures
Submitted: 2018-04-06, last modified: 2018-12-25
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
[12]  oai:arXiv.org:1808.06177  [pdf] - 1901740
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Comments: 7 pages, 5 figures
Submitted: 2018-08-19, last modified: 2018-12-22
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
[13]  oai:arXiv.org:1807.08516  [pdf] - 1786927
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Comments: 18 pages, 5 figures
Submitted: 2018-07-23, last modified: 2018-11-18
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $\alpha' / \alpha$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $\alpha' / \alpha < 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
[14]  oai:arXiv.org:1803.00752  [pdf] - 1732596
Angular dependence of columnar recombination in high pressure xenon gas using time profile of scintillation emission
Comments: 11 pages, 11figures
Submitted: 2018-03-02, last modified: 2018-06-04
The angular dependence of the columnar recombination in xenon gas, if observed for low energy nuclear tracks, can be used for a direction-sensitive dark matter search. We measured both scintillation and ionization to study columnar recombination for 5.4 MeV alpha particles in a high pressure gas detector filled with 8 atm xenon. Since the recombination photons are emitted several~$\mu$s after de-excitation emission, scintillation photons are separated to the fast and slow components. The fast component does not show dependence on the track angle relative to the drift electric field, on the other hand, the slow component increases when the track is aligned with the electric field. The result indicates that the track angle relative to the electric field can be reconstructed from the scintillation time profile.
[15]  oai:arXiv.org:1801.10096  [pdf] - 1690355
Direct dark matter search by annual modulation with 2.7 years of XMASS-I data
Comments: 10 pages, 11 figures
Submitted: 2018-01-30, last modified: 2018-05-25
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.
[16]  oai:arXiv.org:1707.08995  [pdf] - 1586478
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Comments: 11 pages, 6 figures, published in PTEP
Submitted: 2017-07-19, last modified: 2017-11-15
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $\delta = 2$ that axions can propagate in.
[17]  oai:arXiv.org:1709.06219  [pdf] - 1648626
Study of Negative-Ion TPC Using {\mu}-PIC for Directional Dark Matter Search
Comments:
Submitted: 2017-09-18
Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the {\mu}-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.
[18]  oai:arXiv.org:1707.04591  [pdf] - 1585955
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Battaglieri, Marco; Belloni, Alberto; Chou, Aaron; Cushman, Priscilla; Echenard, Bertrand; Essig, Rouven; Estrada, Juan; Feng, Jonathan L.; Flaugher, Brenna; Fox, Patrick J.; Graham, Peter; Hall, Carter; Harnik, Roni; Hewett, JoAnne; Incandela, Joseph; Izaguirre, Eder; McKinsey, Daniel; Pyle, Matthew; Roe, Natalie; Rybka, Gray; Sikivie, Pierre; Tait, Tim M. P.; Toro, Natalia; Van De Water, Richard; Weiner, Neal; Zurek, Kathryn; Adelberger, Eric; Afanasev, Andrei; Alexander, Derbin; Alexander, James; Antochi, Vasile Cristian; Asner, David Mark; Baer, Howard; Banerjee, Dipanwita; Baracchini, Elisabetta; Barbeau, Phillip; Barrow, Joshua; Bastidon, Noemie; Battat, James; Benson, Stephen; Berlin, Asher; Bird, Mark; Blinov, Nikita; Boddy, Kimberly K.; Bondi, Mariangela; Bonivento, Walter M.; Boulay, Mark; Boyce, James; Brodeur, Maxime; Broussard, Leah; Budnik, Ranny; Bunting, Philip; Caffee, Marc; Caiazza, Sabato Stefano; Campbell, Sheldon; Cao, Tongtong; Carosi, Gianpaolo; Carpinelli, Massimo; Cavoto, Gianluca; Celentano, Andrea; Chang, Jae Hyeok; Chattopadhyay, Swapan; Chavarria, Alvaro; Chen, Chien-Yi; Clark, Kenneth; Clarke, John; Colegrove, Owen; Coleman, Jonathon; Cooke, David; Cooper, Robert; Crisler, Michael; Crivelli, Paolo; D'Eramo, Francesco; D'Urso, Domenico; Dahl, Eric; Dawson, William; De Napoli, Marzio; De Vita, Raffaella; DeNiverville, Patrick; Derenzo, Stephen; Di Crescenzo, Antonia; Di Marco, Emanuele; Dienes, Keith R.; Diwan, Milind; Dongwi, Dongwi Handiipondola; Drlica-Wagner, Alex; Ellis, Sebastian; Ezeribe, Anthony Chigbo; Farrar, Glennys; Ferrer, Francesc; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fiorillo, Giuliana; Fornal, Bartosz; Freyberger, Arne; Frugiuele, Claudia; Galbiati, Cristian; Galon, Iftah; Gardner, Susan; Geraci, Andrew; Gerbier, Gilles; Graham, Mathew; Gschwendtner, Edda; Hearty, Christopher; Heise, Jaret; Henning, Reyco; Hill, Richard J.; Hitlin, David; Hochberg, Yonit; Hogan, Jason; Holtrop, Maurik; Hong, Ziqing; Hossbach, Todd; Humensky, T. B.; Ilten, Philip; Irwin, Kent; Jaros, John; Johnson, Robert; Jones, Matthew; Kahn, Yonatan; Kalantarians, Narbe; Kaplinghat, Manoj; Khatiwada, Rakshya; Knapen, Simon; Kohl, Michael; Kouvaris, Chris; Kozaczuk, Jonathan; Krnjaic, Gordan; Kubarovsky, Valery; Kuflik, Eric; Kusenko, Alexander; Lang, Rafael; Leach, Kyle; Lin, Tongyan; Lisanti, Mariangela; Liu, Jing; Liu, Kun; Liu, Ming; Loomba, Dinesh; Lykken, Joseph; Mack, Katherine; Mans, Jeremiah; Maris, Humphrey; Markiewicz, Thomas; Marsicano, Luca; Martoff, C. J.; Mazzitelli, Giovanni; McCabe, Christopher; McDermott, Samuel D.; McDonald, Art; McKinnon, Bryan; Mei, Dongming; Melia, Tom; Miller, Gerald A.; Miuchi, Kentaro; Nazeer, Sahara Mohammed Prem; Moreno, Omar; Morozov, Vasiliy; Mouton, Frederic; Mueller, Holger; Murphy, Alexander; Neilson, Russell; Nelson, Tim; Neu, Christopher; Nosochkov, Yuri; O'Hare, Ciaran; Oblath, Noah; Orrell, John; Ouellet, Jonathan; Pastore, Saori; Paul, Sebouh; Perelstein, Maxim; Peter, Annika; Phan, Nguyen; Phinney, Nan; Pivovaroff, Michael; Pocar, Andrea; Pospelov, Maxim; Pradler, Josef; Privitera, Paolo; Profumo, Stefano; Raggi, Mauro; Rajendran, Surjeet; Randazzo, Nunzio; Raubenheimer, Tor; Regenfus, Christian; Renshaw, Andrew; Ritz, Adam; Rizzo, Thomas; Rosenberg, Leslie; Rubbia, Andre; Rybolt, Ben; Saab, Tarek; Safdi, Benjamin R.; Santopinto, Elena; Scarff, Andrew; Schneider, Michael; Schuster, Philip; Seidel, George; Sekiya, Hiroyuki; Seong, Ilsoo; Simi, Gabriele; Sipala, Valeria; Slatyer, Tracy; Slone, Oren; Smith, Peter F; Smolinsky, Jordan; Snowden-Ifft, Daniel; Solt, Matthew; Sonnenschein, Andrew; Sorensen, Peter; Spooner, Neil; Srivastava, Brijesh; Stancu, Ion; Strigari, Louis; Strube, Jan; Sushkov, Alexander O.; Szydagis, Matthew; Tanedo, Philip; Tanner, David; Tayloe, Rex; Terrano, William; Thaler, Jesse; Thomas, Brooks; Thorpe, Brianna; Thorpe, Thomas; Tiffenberg, Javier; Tran, Nhan; Trovato, Marco; Tully, Christopher; Tyson, Tony; Vachaspati, Tanmay; Vahsen, Sven; van Bibber, Karl; Vandenbroucke, Justin; Villano, Anthony; Volansky, Tomer; Wang, Guojian; Ward, Thomas; Wester, William; Whitbeck, Andrew; Williams, David A.; Wing, Matthew; Winslow, Lindley; Wojtsekhowski, Bogdan; Yu, Hai-Bo; Yu, Shin-Shan; Yu, Tien-Tien; Zhang, Xilin; Zhao, Yue; Zhong, Yi-Ming
Comments: 102 pages + references
Submitted: 2017-07-14
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
[19]  oai:arXiv.org:1703.07600  [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an Electron-Tracking Compton Camera
Comments: 22 pages, 19 figures, 1 table, accepted for publication in ApJ
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging polarimeter. The ETCC provides powerful background rejection and a high modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging based on a well-defined point spread function. Importantly, we demonstrated for the first time the stability of the modulation factor under realistic conditions of off-axis incidence and huge backgrounds using the SPring-8 polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$ 0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$ and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis incidence. These measured results are consistent with the simulation results. Consequently, we found that the satellite-ETCC proposed in Tanimori et al. (2015) would provide all-sky surveys of weak persistent sources of 13 mCrab with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a $6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year observation.
[20]  oai:arXiv.org:1702.01483  [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Comments: 22 pages, 8 figures
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
[21]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[22]  oai:arXiv.org:1604.01503  [pdf] - 1458949
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Comments: 7 pages, 3 figures, accepted for publication in Nucl. Instrum. Meth. A
Submitted: 2016-04-06, last modified: 2016-08-18
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
[23]  oai:arXiv.org:1511.04807  [pdf] - 1413079
Direct dark matter search by annual modulation in XMASS-I
Comments: 5 pages, 4 figures
Submitted: 2015-11-15, last modified: 2016-05-25
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$\gamma$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
[24]  oai:arXiv.org:1508.00990  [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Comments: 11 pages, 24 figures
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
[25]  oai:arXiv.org:1507.03850  [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Comments: 19 pages, 12 figures, Accepted to the Astrophysical Journal
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
[26]  oai:arXiv.org:1507.06987  [pdf] - 1251453
Light Dark Matter Search with SOIPIX
Comments: Proceedings of International Workshop on SOI Pixel Detector (SOIPIX2015), Tohoku University, Sendai, Japan, 3-6, June, 2015. C15-06-03
Submitted: 2015-07-24
We propose a light dark matter search experiment using an SOI pixel detector (SOIPIX). The event-driven SOIPIX can be a powerful tool for detecting light WIMPs because of its low energy threshold (< 1 keV) and high timing resolution (few {\mu}s). In this study, we evaluate the performance of an SOIPIX prototype detector and we examine the required specifications of SOIPIX for our target sensitivity.
[27]  oai:arXiv.org:1412.3918  [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Comments: 10 pages, 8figures, http://www-cr.scphys.kyoto-u.ac.jp/research/MeV-gamma/wiki/wiki.cgi , PSD10
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
[28]  oai:arXiv.org:1406.0502  [pdf] - 869600
Search for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector
Comments: 12 pages, 3 figures, accepted for publication in Physical Review Letters
Submitted: 2014-06-02, last modified: 2014-08-21
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data no significant excess above background was observed in the fiducial mass of 41 kg. The present limit for the vector super-WIMPs excludes the possibility that such particles constitute all of dark matter. The absence of a signal also provides the most stringent direct constraint on the coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented sensitivity was achieved exploiting the low background at a level $10^{-4}$ kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
[29]  oai:arXiv.org:1401.4737  [pdf] - 1425198
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from the XMASS-I experiment
Comments: 13 pages, 7 figures, to be published in PTEP
Submitted: 2014-01-19, last modified: 2014-04-29
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to derive our limits without explicitly subtracting the remaining events which are compatible with background expectations and derive for e.g. a 50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei of 3.2 pb at the 90% confidence level.
[30]  oai:arXiv.org:1312.0438  [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the SMILE-II Experiment
Comments: 9 pages, 7 figures, Proceedings of the 15th International Workshop on Radiation Imaging Detectors (iWoRiD 2013)
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed the Electron-Tracking Compton Camera (ETCC), and carried out the first performance test at room condition using several gamma-ray sources in the sub-MeV energy band. Using a simple track analysis for a quick first test of the performance, the gamma-ray imaging capability was demonstrated by clear images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV. As the greatest impact of this work, a gamma-ray detection efficiency on the order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one order of magnitude higher than our previous experiment. This angular resolution and detection efficiency enables us to detect the Crab Nebula at the 5 sigma level with several hours observation at balloon altitude in middle latitude. Furthermore, good consistency of efficiencies between this performance test and simulation including only physical processes has a large importance; it means we achieve nearly 100% detection of Compton recoil electrons. Thus, our estimation of enhancements by upgrades of the detector is more dependable. We are planning to confirm the imaging capability of the ETCC by observation of celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment II). The SMILE-II and following SMILE-III project will be an important key of sub-MeV/MeV gamma-ray astronomy.
[31]  oai:arXiv.org:1212.6153  [pdf] - 753387
Search for solar axions in XMASS, a large liquid-xenon detector
Comments:
Submitted: 2012-12-26, last modified: 2013-05-29
XMASS, a low-background, large liquid-xenon detector, was used to search for solar axions that would be produced by bremsstrahlung and Compton effects in the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$ (90% C.L.), which is a factor of two stronger than the existing experimental limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are 1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced the most stringent limit, which is better than that previously derived from astrophysical arguments regarding the Sun to date.
[32]  oai:arXiv.org:1211.5404  [pdf] - 620998
Light WIMP search in XMASS
Comments: 13 pages, 8 figures
Submitted: 2012-11-22, last modified: 2013-01-16
A search for light dark matter using low-threshold data from the single phase liquid xenon scintillation detector XMASS, has been conducted. Using the entire 835 kg inner volume as target, the analysis threshold can be lowered to 0.3 keVee (electron-equivalent) to search for light dark matter. With low-threshold data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and without discriminating between nuclear-recoil and electronic events, XMASS excludes part of the parameter space favored by other experiments.
[33]  oai:arXiv.org:1301.2815  [pdf] - 831840
XMASS detector
Comments: 21 pages, 9 figures
Submitted: 2013-01-13
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon. The first phase of the XMASS experiment searches for dark matter. In this paper, we describe the XMASS detector in detail, including its configuration, data acquisition equipment and calibration system.
[34]  oai:arXiv.org:1109.3099  [pdf] - 1084087
NEWAGE
Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011
Submitted: 2011-09-14, last modified: 2011-09-15
NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the detector components with radio-pure materials. We also studied the possibilities of head-tail recognition of nuclear tracks in the surface laboratory. For the future large volume detector, we are developing a pixel ASIC named QPIX. In this paper, these recent R&D activities are described.
[35]  oai:arXiv.org:1103.3436  [pdf] - 966507
Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon Altitudes with an Electron-tracking Compton Camera
Comments: The Astrophysical Journal accepted
Submitted: 2011-03-17, last modified: 2011-03-23
We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be ten times better than that of other experiments at around 1 MeV.
[36]  oai:arXiv.org:1002.1794  [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark matter detector
Comments: 21 pages, 8 figures, to appear in Physics Letters B
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152 Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg, respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly interacting massive particle (WIMP)-proton cross section limits by a direction-sensitive method were achieved including a new record of 5400 pb for 150 GeV/c2 WIMPs. We studied the remaining background and found that ambient gamma-rays contributed about one-fifth of the remaining background and radioactive contaminants inside the gas chamber contributed the rest.
[37]  oai:arXiv.org:0911.0323  [pdf] - 902277
The case for a directional dark matter detector and the status of current experimental efforts
Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
[38]  oai:arXiv.org:0708.2579  [pdf] - 4090
Direction-sensitive dark matter search results in a surface laboratory
Comments: 9 figures, accepted for publication in Phys. Lett. B
Submitted: 2007-08-19
We developed a three-dimensional gaseous tracking device and performed a direction-sensitive dark matter search in a surface laboratory. By using 150 Torr carbon-tetrafluoride (CF_4 gas), we obtained a sky map drawn with the recoil directions of the carbon and fluorine nuclei, and set the first limit on the spin-dependent WIMP (Weakly Interacting Massive Particles)-proton cross section by a direction-sensitive method. Thus, we showed that a WIMP-search experiment with a gaseous tracking device can actually set limits. Furthermore, we demonstrated that this method will potentially play a certain role in revealing the nature of dark matter when a low-background large-volume detector is developed.
[39]  oai:arXiv.org:astro-ph/0601568  [pdf] - 79426
Development of Gaseous Tracking Devices for the Search of WIMPs
Comments: 8 pages, 4 figures, Proceedings of the 7th international workshop on position sensitive detectors(PSD7), submitted to NIM A
Submitted: 2006-01-25, last modified: 2006-02-14
The Time Projection Chamber (TPC) has been recognized as a potentially powerful detector for the search of WIMPs by measuring the directions of nuclear recoils, in which the most convincing signature of WIMPs, caused by the Earth's motion around the Galaxy, appears. We report on the first results of a performance study of the neutron exposure of our prototype micro-TPC with Ar-C$_2$H$_6$ (90:10) and CF$_4$ gas of 150 Torr.
[40]  oai:arXiv.org:astro-ph/0412047  [pdf] - 69451
Development of an advanced Compton camera with gaseous TPC and scintillator
Comments: 4 pages, 5 figures. Proceedings of the 6th International Workshop On Radiation Imaging Detectors
Submitted: 2004-12-02
A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM (Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV gamma-rays were $18^\circ$ and $35^\circ$, respectively.
[41]  oai:arXiv.org:astro-ph/0403518  [pdf] - 63709
MeV Gamma-Ray Imaging Detector with micro-TPC
Comments: 7 pages, 6 figures Proceedings of the "Astronomy With Radioactives IV and Filling The Sensitivity Gap In MEV Astronomy", May 26-30, 2003 Seeon, Bavaria, Germany
Submitted: 2004-03-22
We propose a new imaging gamma-ray detector in the MeV region. By measuring the directions and energies of not only a scattered gamma ray but also a recoil electron, the direction of an incident gamma ray would be essentially reconstructed event by event. Furthermore, one of two measured (zenith and azimuth) angles of a recoil electron gives us an additional redundancy which enables us to reject the background events by kinematic constraints. In order to measure the track of a recoil electron, the micro Time Projection Chamber($\mu$-TPC) has been developed, which can measure the successive positions of the track of charged particles in a few hundred micron meter pitch. The $\mu$-TPC consists of the new type of a gas proportional chamber: micro PIxel gas Chamber ($\mu$-PIC) which is one of wireless gas chambers and expected to be robust and stable. Using this $\mu$-TPC and the Anger camera for the detection of a scattered gamma ray, we have obtained the first gamma-ray image by the full reconstruction of the direction of gamma rays event by event.
[42]  oai:arXiv.org:astro-ph/0310638  [pdf] - 880671
Detecting the WIMP-wind via spin-dependent interactions
Comments: 14 pages, 5 figures, submitted for Physics Letters B
Submitted: 2003-10-22
Revealing the nature of dark matter is one of the most interesting tasks in astrophysics. Measuring the distribution of recoil angles is said to be one of the most reliable methods to detect a positive signature of dark matter. We focused on measurements via spin-dependent interactions, and studied the feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into account the performance of an existing three-dimensional tracking detector. We consequently found that it is highly possible to detect a positive signature of dark matter via spin-dependent interactions.
[43]  oai:arXiv.org:astro-ph/0306365  [pdf] - 57446
Limits on the WIMP-Nucleon Coupling Coefficients from Dark Matter Search Experiment with NaF Bolometer
Comments: 10 pages, 4 figures
Submitted: 2003-06-18, last modified: 2003-10-08
We have performed the underground dark matter search experiment with a sodium fl uoride (NaF) bolometer array from 2002 through 2003 at Kamioka Observatory (2700 m.w.e.). The bolometer array consists of eight NaF absorbers with a total mass of 176 g, and sensitive NTD germanium thermistors glued to each of them. This experiment aims for the direct detection of weakly interacting massive part icles (WIMPs) via spin-dependent interaction. With an exposure of 3.38 kg days, we derived the limits on the WIMP-n ucleon coupling coefficients, a_p and a_n. These limits confirmed and tightened those derived from our previous results wit h the lithium fluoride (LiF) bolometer. Our results excluded the parameter space complementary to the results obtained b y NaI detectors of UKDMC experiment.
[44]  oai:arXiv.org:hep-ex/0301012  [pdf] - 113348
Performance of the TPC with Micro Pixel Chamber Readout: micro-TPC
Comments: 6 pages 16 figures, submitted for IEEE/TNS 2002
Submitted: 2003-01-10, last modified: 2003-04-02
Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position sensitive gaseous detector, or the $\mu$-PIC, with the detection area of 10$\times$10 cm${}^{2}$ and 65536 anode electrodes of 400 $\mu$m pitch. We achieved the gas gain of over 10000 without any other multipliers. With the pipe-line readout system specially developed for the $\mu$-PIC, we detected X-rays at the rate as high as 7.7 Mcps. We attached a drift cage with an 8 cm drift length to the $\mu$-PIC and developed a micro-TPC. We measured the basic performances of the micro-TPC and took three-dimensional tracks of electrons. We also developed a prototype of the MeV gamma-ray imaging detector which is a hybrid of the micro-TPC and NaI(Tl) scintillators and confirmed its concept by reconstructing the obtained data.
[45]  oai:arXiv.org:astro-ph/0204411  [pdf] - 48956
First results from dark matter search experiment with LiF bolometer at Kamioka Underground Laboratory
Comments: 15 pages, 5 figures
Submitted: 2002-04-24, last modified: 2003-02-17
Tokyo group has performed first underground dark matter search experiment in 2001 through 2002 at Kamioka Observatory(2700m.w.e). The detector is eight LiF bolometers with total mass 168g aiming for the direct detection of WIMPs via spin-dependent interaction. With a total exposure of 4.1 kg days, we derived the limits in the a_p-a_n (WIMP-nucleon couplings) plane and excluded a large part of the parameter space allowed by the UKDMC experiment.