Normalized to: Miuchi, K.
[1]
oai:arXiv.org:2006.09721 [pdf] - 2124928
Observation of Excess Electronic Recoil Events in XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J. R.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Depoian, A.;
Di Gangi, P.;
Di Giovanni, A.;
Di Stefano, R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Galloway, M.;
Gao, F.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Long, J.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Mancuso, A.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Mizukoshi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Plante, G.;
Qin, J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Weiss, M.;
Wenz, D.;
Wittweg, C.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.;
Mougeot, X.
Submitted: 2020-06-17, last modified: 2020-06-30
We report results from searches for new physics with low-energy electronic
recoil data recorded with the XENON1T detector, with an exposure of 0.65 t-y
and an unprecedentedly low background rate of $76 \pm 2_{stat}$ events/(t y
keV) between 1-30 keV. An excess over known backgrounds is observed below 7
keV, rising towards lower energies and prominent between 2-3 keV. The solar
axion model has a 3.5$\sigma$ significance, and a three-dimensional 90%
confidence surface is reported for axion couplings to electrons, photons, and
nucleons. This surface is inscribed in the cuboid defined by $g_{ae} < 3.7
\times 10^{-12}$, $g_{ae}g_{an}^{eff} < 4.6 \times 10^{-18}$, and
$g_{ae}g_{a\gamma} < 7.6\times10^{-22}~{GeV}^{-1}$, and excludes either
$g_{ae}=0$ or $g_{ae}g_{a\gamma}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic
moment signal is similarly favored over background at 3.2$\sigma$ and a
confidence interval of $\mu_{\nu} \in (1.4,~2.9)\times10^{-11}\mu_B$ (90% C.L.)
is reported. Both results are in strong tension with stellar constraints. The
excess can also be explained by $\beta$ decays of tritium at 3.2$\sigma$
significance with a corresponding tritium concentration in xenon of $(6.2 \pm
2.0) \times 10^{-25}$ mol/mol. Such a trace amount can be neither confirmed nor
excluded with current knowledge of production and reduction mechanisms. The
significances of the solar axion and neutrino magnetic moment hypotheses are
decreased to 2.1$\sigma$ and 0.9$\sigma$, respectively, if an unconstrained
tritium component is included in the fitting. With respect to bosonic dark
matter, the excess favors a monoenergetic peak at ($2.3 \pm 0.2$) keV (68%
C.L.) with a 3.0$\sigma$ global (4.0$\sigma$ local) significance over
background. This analysis sets the most restrictive direct constraints to date
on pseudoscalar and vector bosonic dark matter for most masses between 1 and
210 keV/c$^2$.
[2]
oai:arXiv.org:2005.11891 [pdf] - 2112667
Search for exotic neutrino-electron interactions using solar neutrinos
in XMASS-I
XMASS collaboration;
Abe, K.;
Chen, Y.;
Hiraide, K.;
Ichimura, K.;
Imaizumi, S.;
Kato, N.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Kim, Y. H.;
Ishii, R.;
Itow, Y.;
Kanzawa, K.;
Martens, K.;
Mason, A.;
Suzuki, Y.;
Miuchi, K.;
Takeuchi, Y.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Ogawa, H.;
Kishimoto, Y.;
Nishijima, K.;
Fushimi, K.;
Xu, B. D.;
Nakamura, S.
Submitted: 2020-05-24
We have searched for exotic neutrino-electron interactions that could be
produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark
photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed
no significant signals in 711 days of data. We obtain an upper limit for
neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level
assuming all three species of neutrino have common millicharge. We also set
flavor dependent limits assuming the respective neutrino flavor is the only one
carrying a millicharge, $7.3 \times 10^{-12} e$ for $\nu_e$, $1.1 \times
10^{-11} e$ for $\nu_{\mu}$, and $1.1 \times 10^{-11} e$ for $\nu_{\tau}$.
These limits are the most stringent yet obtained from direct measurements. We
also obtain an upper limit for the neutrino magnetic moment of
1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for
the coupling constant of dark photons in the $U(1)_{B-L}$ model of
1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$,
and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
[3]
oai:arXiv.org:2004.09706 [pdf] - 2081177
Development of a Negative Ion Micro TPC Detector with SF$_{6}$ Gas for
the Directional Dark Matter Search
Submitted: 2020-04-20
A negative ion micro time projection chamber (NI$\mu$TPC) was developed and
its performance studied. An NI$\mu$TPC is a novel technology that enables the
measurement of absolute $z$ coordinates for self-triggering TPCs. This
technology provides full-fiducialization analysis, which is not possible with
conventional gaseous TPCs, and is useful for directional dark matter searches
in terms of background rejection and the improvement of the angular resolution.
The developed NI$\mu$TPC prototype had a detection volume of 12.8 $\times$ 25.6
$\times$ 144 mm$^{3}$. The absolute $z$ coordinate was determined with a
location accuracy of 16 mm using minority carrieres of SF$_{5}^{-}$.
Simultaneously, there was a successful reconstruction of the three-dimensional
(3D) tracks with a spatial resolution of 130 $\mu\rm{m}$. This is the first
demonstration of 3D tracking with the detection of absolute $z$ coordinates,
and it is an important step in improving the sensitivity of directional dark
matter searches.
[4]
oai:arXiv.org:1707.05523 [pdf] - 2073943
Discrimination of anisotropy in dark matter velocity distribution with
directional detectors
Submitted: 2017-07-18, last modified: 2020-04-01
Directional detection of dark matter has sensitivity for both recoil energy
and direction of nuclear recoil. It opens the way to measure local velocity
distribution of dark matter. In this paper, we study possibility to
discriminate isotropic distribution and anisotropic one suggested by a N-body
simulation with directional detector. Numerical simulation is performed for two
cases according to the detectors, one corresponds to angular histogram and the
other is energy-angular distribution of the signals. We reveal that the
anisotropy of velocity distribution can be discriminated at 90% C.L. with
chi-squared test if O($10^4$) signals are obtained.
[5]
oai:arXiv.org:2003.03825 [pdf] - 2060953
Energy resolution and linearity in the keV to MeV range measured in
XENON1T
Aprile, E.;
Aalbers, J.;
Agostini, F.;
Alfonsi, M.;
Althueser, L.;
Amaro, F. D.;
Antochi, V. C.;
Angelino, E.;
Angevaare, J.;
Arneodo, F.;
Barge, D.;
Baudis, L.;
Bauermeister, B.;
Bellagamba, L.;
Benabderrahmane, M. L.;
Berger, T.;
Breur, P. A.;
Brown, A.;
Brown, E.;
Bruenner, S.;
Bruno, G.;
Budnik, R.;
Capelli, C.;
Cardoso, J. M. R.;
Cichon, D.;
Cimmino, B.;
Clark, M.;
Coderre, D.;
Colijn, A. P.;
Conrad, J.;
Cussonneau, J. P.;
Decowski, M. P.;
Di Stefano, A. Depoian P. Di Gangi A. Di Giovanni R.;
Diglio, S.;
Elykov, A.;
Eurin, G.;
Ferella, A. D.;
Fulgione, W.;
Gaemers, P.;
Gaior, R.;
Rosso, A. Gallo;
Galloway, M.;
Gao, F.;
Garbini, M.;
Grandi, L.;
Hasterok, C.;
Hils, C.;
Hiraide, K.;
Hoetzsch, L.;
Hogenbirk, E.;
Howlett, J.;
Iacovacci, M.;
Itow, Y.;
Joerg, F.;
Kato, N.;
Kazama, S.;
Kobayashi, M.;
Koltman, G.;
Kopec, A.;
Landsman, H.;
Lang, R. F.;
Levinson, L.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lombardi, F.;
Lopes, J. A. M.;
Fune, E. López;
Macolino, C.;
Mahlstedt, J.;
Manenti, L.;
Manfredini, A.;
Marignetti, F.;
Undagoitia, T. Marrodán;
Martens, K.;
Masbou, J.;
Masson, D.;
Mastroianni, S.;
Messina, M.;
Miuchi, K.;
Molinario, A.;
Morå, K.;
Moriyama, S.;
Mosbacher, Y.;
Murra, M.;
Naganoma, J.;
Ni, K.;
Oberlack, U.;
Odgers, K.;
Palacio, J.;
Pelssers, B.;
Peres, R.;
Pienaar, J.;
Pizzella, V.;
Qin, G. Plante J.;
Qiu, H.;
García, D. Ramírez;
Reichard, S.;
Rocchetti, A.;
Rupp, N.;
Santos, J. M. F. dos;
Sartorelli, G.;
Šarčević, N.;
Scheibelhut, M.;
Schindler, S.;
Schreiner, J.;
Schulte, D.;
Schumann, M.;
Lavina, L. Scotto;
Selvi, M.;
Semeria, F.;
Shagin, P.;
Shockley, E.;
Silva, M.;
Simgen, H.;
Takeda, A.;
Therreau, C.;
Thers, D.;
Toschi, F.;
Trinchero, G.;
Tunnell, C.;
Vargas, M.;
Volta, G.;
Wack, O.;
Wang, H.;
Wei, Y.;
Weinheimer, C.;
Xu, M. Weiss;
Wenz, D.;
Wittweg, C.;
Wulf, J.;
Xu, Z.;
Yamashita, M.;
Ye, J.;
Zavattini, G.;
Zhang, Y.;
Zhu, T.;
Zopounidis, J. P.
Submitted: 2020-03-08
Xenon dual-phase time projection chambers designed to search for Weakly
Interacting Massive Particles have so far shown a relative energy resolution
which degrades with energy above $\sim$200 keV. This has limited their
sensitivity in the search for rare events like the neutrinoless double-beta
decay of $^{136}$Xe at its $Q$-value, $Q_{\beta\beta}\simeq$ 2.46 MeV. For the
XENON1T dual-phase time projection chamber, we demonstrate that the relative
energy resolution at 1 $\sigma/\mu$ is as low as (0.79$\pm$0.02) % in its
one-ton fiducial mass, and for single-site interactions at $Q_{\beta\beta}$. We
achieve this by using a signal correction method to rectify the saturation
effects of the signal readout system. The very good energy resolution from keV
to MeV energies demonstrated in XENON1T opens up new windows for the xenon
dual-phase dark matter detectors to simultaneously search for other rare
events.
[6]
oai:arXiv.org:1903.04843 [pdf] - 2056762
Probing GHz Gravitational Waves with Graviton-magnon Resonance
Submitted: 2019-03-12, last modified: 2020-03-02
A novel method for extending frequency frontier in gravitational wave
observations is proposed. It is shown that gravitational waves can excite a
magnon. Thus, gravitational waves can be probed by a graviton-magnon detector
which measures resonance fluorescence of magnons. Searching for gravitational
waves with a wave length $\lambda$ by using a ferromagnetic sample with a
dimension $l$, the sensitivity of the graviton-magnon detector reaches spectral
densities, around $5.4 \times 10^{-22} \times (\frac{l}{\lambda /2\pi})^{-2} \
[{\rm Hz}^{-1/2}]$ at 14 GHz and $8.6 \times 10^{-21} \times (\frac{l}{\lambda
/2\pi})^{-2} \ [{\rm Hz}^{-1/2}]$ at 8.2 GHz, respectively.
[7]
oai:arXiv.org:1903.01090 [pdf] - 2038205
Development of an alpha-particle imaging detector based on a low
radioactivity micro-time-projection chamber
Submitted: 2019-03-04, last modified: 2019-10-30
An important issue for rare-event-search experiments, such as the search for
dark matter or neutrinoless double beta decay, is to reduce radioactivity of
the detector materials and the experimental environment. The selection of
materials with low radioactive impurities, such as isotopes of the uranium and
thorium chains, requires a precise measurement of surface and bulk
radioactivity. Focused on the first one, an alpha-particle detector has been
developed based on a gaseous micro-time-projection chamber. A low-alpha mu-PIC
with reduced alpha-emission background was installed in the detector. The
detector offers the advantage of position sensitivity, which allows the
alpha-particle contamination of the sample to be imaged and the background to
be measured at the same time. The detector performance was measured by using an
alpha-particle source. The measurement with a sample was also demonstrated and
the sensitivity is discussed.
[8]
oai:arXiv.org:1907.12729 [pdf] - 1925210
MPGD simulation in negative-ion gas for direction-sensitive dark matter
searches
Submitted: 2019-07-30
Negative-ion time projection chambers (NITPCs) provide the absolute
z-position from the arrival-times' difference of several species of
negative-ions. This is a strong background reduction method for rare event
searches, such as direct dark mater searches. The characteristics of micro
pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both
experiments and simulations to develop an NITPC for dark matter search
experiments. An MPGD simulation method for the negative-ion gas with
Garfield++, which has not yet been established, was developed. We present
herein the MPGD simulation results in negative-ion gas, $\mathrm{SF_{6}}$ gas,
together with the experimental results, such as gain, energy resolution, and
signal creation from the MPGD for future NITPC optimization.
[9]
oai:arXiv.org:1809.05358 [pdf] - 1851548
Search for WIMP-$^{129}$Xe inelastic scattering with particle
identification in XMASS-I
XMASS Collaboration;
Suzuki, T.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-09-14, last modified: 2019-03-19
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with
the single-phase liquid-xenon detector XMASS through inelastic scattering in
which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times
800.0 \; days$) 48 times larger than that of our previous study. The inelastic
excitation sensitivity was improved by detailed evaluation of background, event
classification based on scintillation timing that distinguished $\gamma$-rays
and $\beta$-rays, and simultaneous fitting of the energy spectra of
$\gamma$-like and $\beta$-like samples. No evidence of a WIMP signal was found.
Thus, we set the upper limits of the inelastic channel cross section at 90\%
confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\;
{\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD
WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm
GeV}/c^2$ than the existing experimental limit.
[10]
oai:arXiv.org:1808.03617 [pdf] - 1822844
Development of low radioactivity photomultiplier tubes for the XMASS-I
detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-08-10, last modified: 2019-01-29
XMASS-I is a single-phase liquid xenon detector whose purpose is direct
detection of dark matter. To achieve the low background requirements necessary
in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a
hexagonal window was developed based on the R8778 PMT used in the XMASS
prototype detector. We screened the numerous component materials for their
radioactivity. During development, the largest contributions to the reduction
of radioactivity came from the stem and the dynode support. The glass stem was
exchanged to the Kovar alloy one and the ceramic support were changed to the
quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted
these materials for low background purposes and provided a groundbreaking step
for further reductions of radioactivity in PMTs. Measurements with germanium
detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of
$^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of
$^{60}$Co. In this paper, the radioactive details of the developed R10789 are
described together with our screening methods and the components of the PMT.
[11]
oai:arXiv.org:1804.02180 [pdf] - 1806000
A direct dark matter search in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-04-06, last modified: 2018-12-25
A search for dark matter using an underground single-phase liquid xenon
detector was conducted at the Kamioka Observatory in Japan, particularly for
Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of
data in a fiducial volume containing 97 kg of liquid xenon at the center of the
detector. The event rate in the fiducial volume after the data reduction was
${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm
5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining
events are consistent with our background evaluation, mostly of the
"mis-reconstructed events" originated from $^{210}$Pb in the copper plates
lining the detector's inner surface. The obtained upper limit on a
spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \,
cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence
level, which was the most stringent limit among results from single-phase
liquid xenon detectors.
[12]
oai:arXiv.org:1808.06177 [pdf] - 1901740
Search for sub-GeV dark matter by annual modulation using XMASS-I
detector
Kobayashi, M.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-08-19, last modified: 2018-12-22
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV)
was conducted by looking for an annual modulation signal in XMASS, a
single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by
bremsstrahlung emission was used to search down to an electron equivalent
energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in
calendar time), resulting in a total exposure of 2.38 ton-years. No significant
modulation signal was observed and 90% confidence level upper limits of $1.6
\times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section.
This is the first experimental result of a search for DM mediated by the
bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV
region (4-20 GeV) was conducted with a lower energy threshold than previous
analysis of XMASS. Elastic nuclear scattering was used to search down to a
nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9
$\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
[13]
oai:arXiv.org:1807.08516 [pdf] - 1786927
Search for dark matter in the form of hidden photons and axion-like
particles in the XMASS detector
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Suzuki, T.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Masuda, K.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Fushimi, K.;
Kanzaki, G.;
Nakamura, S.
Submitted: 2018-07-23, last modified: 2018-11-18
Hidden photons and axion-like particles are candidates for cold dark matter
if they were produced non-thermally in the early universe. We conducted a
search for both of these bosons using 800 live-days of data from the XMASS
detector with 327 kg of liquid xenon in the fiducial volume. No significant
signal was observed, and thus we set constraints on the $\alpha' / \alpha$
parameter related to kinetic mixing of hidden photons and the coupling constant
$g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$,
resulting in $\alpha' / \alpha < 6 \times 10^{-26}$ and $g_{Ae} < 4 \times
10^{-13}$. These limits are the most stringent derived from both direct and
indirect searches to date.
[14]
oai:arXiv.org:1803.00752 [pdf] - 1732596
Angular dependence of columnar recombination in high pressure xenon gas
using time profile of scintillation emission
Nakamura, K. D.;
Ban, S.;
Hirose, M.;
Ichikawa, A. K.;
Ishiyama, Y.;
Minamino, A.;
Miuchi, K.;
Nakaya, T.;
Sekiya, H.;
Tanaka, S.;
Ueshima, K.
Submitted: 2018-03-02, last modified: 2018-06-04
The angular dependence of the columnar recombination in xenon gas, if
observed for low energy nuclear tracks, can be used for a direction-sensitive
dark matter search. We measured both scintillation and ionization to study
columnar recombination for 5.4 MeV alpha particles in a high pressure gas
detector filled with 8 atm xenon. Since the recombination photons are emitted
several~$\mu$s after de-excitation emission, scintillation photons are
separated to the fast and slow components. The fast component does not show
dependence on the track angle relative to the drift electric field, on the
other hand, the slow component increases when the track is aligned with the
electric field. The result indicates that the track angle relative to the
electric field can be reconstructed from the scintillation time profile.
[15]
oai:arXiv.org:1801.10096 [pdf] - 1690355
Direct dark matter search by annual modulation with 2.7 years of XMASS-I
data
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2018-01-30, last modified: 2018-05-25
An annual modulation signal due to the Earth orbiting around the Sun would be
one of the strongest indications of the direct detection of dark matter. In
2016, we reported a search for dark matter by looking for this annual
modulation with our single-phase liquid xenon XMASS-I detector. That analysis
resulted in a slightly negative modulation amplitude at low energy. In this
work, we included more than one year of additional data, which more than
doubles the exposure to 800 live days with the same 832 kg target mass. When we
assume weakly interacting massive particle (WIMP) dark matter elastically
scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon
cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8
GeV/c$^2$ at 90\% confidence level with our newly implemented data selection
through a likelihood method. For the model-independent case, without assuming
any specific dark matter model, we obtained more consistency with the null
hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy
region. This search probed this region with an exposure that was larger than
that of DAMA/LIBRA. We also did not find any significant amplitude in the data
for periodicity with periods between 50 and 600 days in the energy region
between 1 to 6 keV.
[16]
oai:arXiv.org:1707.08995 [pdf] - 1586478
Search for solar Kaluza-Klein axion by annual modulation with the
XMASS-I detector
XMASS Collaboration;
Oka, N.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sato, K.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kanzawa, K.;
Kegasa, R.;
Masuda, K.;
Takiya, H.;
Fushimi, K.;
Kanzaki, G.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Miyasaka, M.;
Nishijima, K.;
Nakamura, S.
Submitted: 2017-07-19, last modified: 2017-11-15
In theories with the large extra dimensions beyond the standard 4-dimensional
spacetime, axions could propagate in such extra dimensions, and acquire
Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and
could solve unexplained heating of the solar corona. While most of the solar KK
axions escape from the solar system, a small fraction is gravitationally
trapped in orbits around the Sun. They would decay into two photons inside a
terrestrial detector. The event rate is expected to modulate annually depending
on the distance from the Sun. We have searched for the annual modulation
signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant
event rate modulation is found, and hence we set the first experimental
constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\,
\mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of
$\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number
of extra dimensions $n = 2$, and the number of extra dimensions $\delta = 2$
that axions can propagate in.
[17]
oai:arXiv.org:1709.06219 [pdf] - 1648626
Study of Negative-Ion TPC Using {\mu}-PIC for Directional Dark Matter
Search
Ikeda, Tomonori;
Miuchi, Kentaro;
Ochi, Atsuhiko;
Yakabe, Ryota;
Hashimoto, Takashi;
Taishaku, Ryosuke;
Snowden-Ifft, Daniel P.;
Gauvreau, Jean-Luc;
Tanimori, Toru;
Takada, Atsushi;
Nakamura, Kiseki
Submitted: 2017-09-18
Negative-ion time projection chambers(TPCs) have been studied for low-rate
and high-resolution applications such as dark matter search experiments.
Recently, a full volume fiducialization in a self-triggering TPC was realized.
This innovative technology demonstrated a significant reduction in the
background with MWPC-TPCs. We studied negative-ion TPC using the {\mu}-PIC+GEM
system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at
low pressures. We expect an improvement in detector sensitivity and angular
resolution with better electronics.
[19]
oai:arXiv.org:1703.07600 [pdf] - 1564143
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an
Electron-Tracking Compton Camera
Komura, Shotaro;
Takada, Atsushi;
Mizumura, Yoshitaka;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Oda, Makoto;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tanimori, Toru;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-03-22
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and
the magnetic configuration of various celestial objects, such as binary black
holes or gamma-ray bursts (GRBs). However, statistically significant
polarizations have been detected in few of the brightest objects. Even though
future polarimeters using X-ray telescopes are expected to observe weak
persistent sources, there are no effective approaches to survey transient and
serendipitous sources with a wide field of view (FoV). Here we present an
electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging
polarimeter. The ETCC provides powerful background rejection and a high
modulation factor over a FoV of up to 2$\pi$ sr thanks to its excellent imaging
based on a well-defined point spread function. Importantly, we demonstrated for
the first time the stability of the modulation factor under realistic
conditions of off-axis incidence and huge backgrounds using the SPring-8
polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$
0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$
and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis
incidence. These measured results are consistent with the simulation results.
Consequently, we found that the satellite-ETCC proposed in Tanimori et al.
(2015) would provide all-sky surveys of weak persistent sources of 13 mCrab
with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a
$6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year
observation.
[20]
oai:arXiv.org:1702.01483 [pdf] - 1535425
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on
Geometrical Optics
Tanimori, Toru;
Mizumura, Yoshitaka;
Takada, Atsushi;
Miyamoto, Shohei;
Takemura, Taito;
Kishimoto, Tetsuro;
Komura, Shotaro;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Matsuoka, Yoshihiro;
Miuchi, Kentaro;
Mizumoto, Tetsuya;
Nakamasu, Yuma;
Nakamura, Kiseki;
Parker, Joseph D.;
Sawano, Tatsuya;
Sonoda, Shinya;
Tomono, Dai;
Yoshikawa, Kei
Submitted: 2017-02-05
Since the discovery of nuclear gamma-rays, its imaging has been limited to
pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does
not keep physical information (intensity, or brightness in Optics) along a ray,
and thus is capable of no more than qualitative imaging of bright objects. To
attain quantitative imaging, cameras that realize geometrical optics is
essential, which would be, for nuclear MeV gammas, only possible via complete
reconstruction of the Compton process. Recently we have revealed that "Electron
Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function
(PSF). The information of an incoming gamma is kept along a ray with the PSF
and that is equivalent to geometrical optics. Here we present an
imaging-spectroscopic measurement with the ETCC. Our results highlight the
intrinsic difficulty with CCs in performing accurate imaging, and show that the
ETCC surmounts this problem. The imaging capability also helps the ETCC
suppress the noise level dramatically by ~3 orders of magnitude without a
shielding structure. Furthermore, full reconstruction of Compton process with
the ETCC provides spectra free of Compton edges. These results mark the first
proper imaging of nuclear gammas based on the genuine geometrical optics.
[21]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[22]
oai:arXiv.org:1604.01503 [pdf] - 1458949
A measurement of the time profile of scintillation induced by low energy
gamma-rays in liquid xenon with the XMASS-I detector
XMASS Collaboration;
Takiya, H.;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Tasaka, S.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masuda, K.;
Fushimi, K.;
Martens, K.;
Suzuki, Y.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Oka, N.;
Onishi, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Nishijima, K.;
Nakamura, S.
Submitted: 2016-04-06, last modified: 2016-08-18
We report the measurement of the emission time profile of scintillation from
gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation
detector. Decay time constant was derived from a comparison of scintillation
photon timing distributions between the observed data and simulated samples in
order to take into account optical processes such as absorption and scattering
in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe,
$^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming
two decay components, $\tau_1$ and $\tau_2$, the decay time constant $\tau_2$
increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9
keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all
energy levels. A fast decay component with $\tau_1 \sim 2$ ns was necessary to
reproduce data. Energy dependencies of $\tau_2$ and the fraction of the fast
decay component were studied as a function of the kinetic energy of electrons
induced by gamma-rays. The obtained data almost reproduced previously reported
results and extended them to the lower energy region relevant to direct dark
matter searches.
[23]
oai:arXiv.org:1511.04807 [pdf] - 1413079
Direct dark matter search by annual modulation in XMASS-I
XMASS Collaboration;
Abe, K.;
Hiraide, K.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Kobayashi, M.;
Moriyama, S.;
Nakahata, M.;
Norita, T.;
Ogawa, H.;
Sekiya, H.;
Takachio, O.;
Takeda, A.;
Yamashita, M.;
Yang, B. S.;
Kim, N. Y.;
Kim, Y. D.;
Tasaka, S.;
Fushimi, K.;
Liu, J.;
Martens, K.;
Suzuki, Y.;
Xu, B. D.;
Fujita, R.;
Hosokawa, K.;
Miuchi, K.;
Onishi, Y.;
Oka, N.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, J. S.;
Lee, K. B.;
Lee, M. K.;
Fukuda, Y.;
Itow, Y.;
Kegasa, R.;
Kobayashi, K.;
Masada, K.;
Takiya, H.;
Nishijima, K.;
Nakamura, S.
Submitted: 2015-11-15, last modified: 2016-05-25
A search for dark matter was conducted by looking for an annual modulation
signal due to the Earth's rotation around the Sun using XMASS, a single phase
liquid xenon detector. The data used for this analysis was 359.2 live days
times 832 kg of exposure accumulated between November 2013 and March 2015. When
we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically
scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon
cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we
exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range
at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without
assuming any specific dark matter model but including electron/$\gamma$ events,
showed a slight negative amplitude. The $p$-values obtained with two
independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we
obtained 90\% C.L. upper bounds that can be used to test various models. This
is the first extensive annual modulation search probing this region with an
exposure comparable to DAMA/LIBRA.
[24]
oai:arXiv.org:1508.00990 [pdf] - 1268655
New readout and data-acquisition system in an electron-tracking Compton
camera for MeV gamma-ray astronomy (SMILE-II)
Mizumoto, Tetsuya;
Matsuoka, Yoshihiro;
Mizumura, Yoshitaka;
Tanimori, Toru;
Kubo, Hidetoshi;
Takada, Atsushi;
Iwaki, Satoru;
Sawano, Tatsuya;
Nakamura, Kiseki;
Komura, Shotaro;
Nakamura, Shogo;
Kishimoto, Tetsuro;
Oda, Makoto;
Miyamoto, Shohei;
Takemura, Taito;
Parker, Joseph D.;
Tomono, Dai;
Sonoda, Shinya;
Miuchi, Kentaro;
Kurosawa, Shunsuke
Submitted: 2015-08-05, last modified: 2015-08-29
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton
camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation
background and attaining the high sensitivity of near 1 mCrab in space. Our
ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas
detector for tracking recoil electrons and a position-sensitive scintillation
camera for detecting scattered gamma rays. After the success of a first balloon
experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$
TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV
gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$
medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial
sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II).
To achieve this goal, a 100-times-larger detection area compared with that of
SMILE-I is required without changing the weight or power consumption of the
detector system. In addition, the event rate is also expected to dramatically
increase during observation. Here, we describe both the concept and the
performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to
manage 100 times more data while satisfying the severe restrictions regarding
the weight and power consumption imposed by a balloon-borne observation. In
particular, to improve the detection efficiency of the fine tracks in the TPC
from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in
the TPC. Therefore, for efficient management of such large amounts of data, we
developed a data-acquisition system with parallel data flow.
[25]
oai:arXiv.org:1507.03850 [pdf] - 1267930
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe
by MeV gamma-rays
Tanimori, T.;
Kubo, H.;
Takada, A.;
Iwaki, S.;
Komura, S.;
Kurosawa, S.;
Matsuoka, Y.;
Miuchi, K.;
Miyamoto, S.;
Mizumoto, T.;
Mizumura, Y.;
Nakamura, K.;
Nakamura, S.;
Oda, M.;
Parker, J. D.;
Sawano, T.;
Sonoda, S.;
Takemura, T.;
Tomono, D.;
Ueno, K.
Submitted: 2015-07-14, last modified: 2015-08-04
Photon imaging for MeV gammas has serious difficulties due to huge
backgrounds and unclearness in images, which are originated from incompleteness
in determining the physical parameters of Compton scattering in detection,
e.g., lack of the directional information of the recoil electrons. The recent
major mission/instrument in the MeV band, Compton Gamma Ray
Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$
persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV
band. Here we report the performance of an Electron-Tracking Compton Camera
(ETCC), and prove that it has a good potential to break through this stagnation
in MeV gamma-ray astronomy. The ETCC provides all the parameters of
Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter
Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx),
which CCs cannot measure, is also obtained, and is found to be indeed helpful
to reduce the background under conditions similar to space. Accordingly the
significance in gamma detection is improved severalfold. On the other hand, SPD
is essential to determine the point-spread function (PSF) quantitatively. The
SPD resolution is improved close to the theoretical limit for multiple
scattering of recoil electrons. With such a well-determined PSF, we demonstrate
for the first time that it is possible to provide reliable sensitivity in
Compton imaging without utilizing an optimization algorithm. As such, this
study highlights the fundamental weak-points of CCs. In contrast we demonstrate
the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg
cm$^{-2}$ s$^{-1}$ at 1 MeV.
[26]
oai:arXiv.org:1507.06987 [pdf] - 1251453
Light Dark Matter Search with SOIPIX
Submitted: 2015-07-24
We propose a light dark matter search experiment using an SOI pixel detector
(SOIPIX). The event-driven SOIPIX can be a powerful tool for detecting light
WIMPs because of its low energy threshold (< 1 keV) and high timing resolution
(few {\mu}s). In this study, we evaluate the performance of an SOIPIX prototype
detector and we examine the required specifications of SOIPIX for our target
sensitivity.
[27]
oai:arXiv.org:1412.3918 [pdf] - 1223621
Performance of a new electron-tracking Compton camera under intense
radiations from a water target irradiated with a proton beam
Matsuoka, Yoshihiro;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Mizumura, Y.;
Iwaki, S.;
Sawano, T.;
Komura, S.;
Kishimoto, T.;
Oda, M.;
Takemura, T.;
Miyamoto, S.;
Sonoda, S.;
Tomono, D.;
Miuchi, K.;
Kabuki, S.;
Kurosawa, S.
Submitted: 2014-12-12, last modified: 2015-01-22
We have developed an electron-tracking Compton camera (ETCC) for use in
next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time
projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC
measures the three dimensional tracks of Compton-recoil electrons, the ETCC can
completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates
efficient background rejection power in Compton-kinematics tests, identifies
particle from the energy deposit rate (dE/dX) registered in the TPC, and
provides high quality imaging by completely reconstructing the Compton
scattering process. We are planning the "Sub-MeV gamma ray Imaging
Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey
satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for
observing the Crab nebula, are ongoing. However, observations at balloon
altitudes or satellite orbits are obstructed by radiation background from the
atmosphere and the detector itself. The background rejection power was checked
using proton accelerator experiments conducted at the Research Center for
Nuclear Physics, Osaka University. To create the intense radiation fields
encountered in space, which comprise gamma rays, neutrons, protons, and other
energetic entities, we irradiated a water target with a 140 MeV proton beam and
placed a SMILE-II ETCC near the target. In this situation, the counting rate
was five times than that expected at the balloon altitude. Nonetheless, the
ETCC stably operated and identified particles sufficiently to obtain a clear
gamma ray image of the checking source. Here, we report the performance of our
detector and demonstrate its effective background rejection based in electron
tracking experiments.
[28]
oai:arXiv.org:1406.0502 [pdf] - 869600
Search for bosonic superweakly interacting massive dark matter particles
with the XMASS-I detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Ichimura, K.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-06-02, last modified: 2014-08-21
Bosonic superweakly interacting massive particles (super-WIMPs) are a
candidate for warm dark matter. With the absorption of such a boson by a xenon
atom these dark matter candidates would deposit an energy equivalent to their
rest mass in the detector. This is the first direct detection experiment
exploring the vector super-WIMPs in the mass range between 40 and 120 keV.
Using 165.9 days of data no significant excess above background was observed in
the fiducial mass of 41 kg. The present limit for the vector super-WIMPs
excludes the possibility that such particles constitute all of dark matter. The
absence of a signal also provides the most stringent direct constraint on the
coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented
sensitivity was achieved exploiting the low background at a level $10^{-4}$
kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
[29]
oai:arXiv.org:1401.4737 [pdf] - 1425198
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from
the XMASS-I experiment
Uchida, H.;
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Ichimura, K.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2014-01-19, last modified: 2014-04-29
A search for inelastic scattering of Weakly Interacting Massive Particles
(WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase
liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted
volume containing 41 kg of LXe at the very center of our detector we observed
no significant excess of events in 165.9 days of data. Our background reduction
allowed us to derive our limits without explicitly subtracting the remaining
events which are compatible with background expectations and derive for e.g. a
50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei
of 3.2 pb at the 90% confidence level.
[30]
oai:arXiv.org:1312.0438 [pdf] - 829396
Development of a 30 cm-cube Electron-Tracking Compton Camera for the
SMILE-II Experiment
Mizumura, Y.;
Tanimori, T.;
Kubo, H.;
Takada, A.;
Parker, J. D.;
Mizumoto, T.;
Sonoda, S.;
Tomono, D.;
Sawano, T.;
Nakamura, K.;
Matsuoka, Y.;
Komura, S.;
Nakamura, S.;
Oda, M.;
Miuchi, K.;
Kabuki, S.;
Kishimoto, Y.;
Kurosawa, S.;
Iwaki, S.
Submitted: 2013-12-02, last modified: 2014-02-07
To explore the sub-MeV/MeV gamma-ray window for astronomy, we have developed
the Electron-Tracking Compton Camera (ETCC), and carried out the first
performance test at room condition using several gamma-ray sources in the
sub-MeV energy band. Using a simple track analysis for a quick first test of
the performance, the gamma-ray imaging capability was demonstrated by clear
images and 5.3 degrees of angular resolution measure (ARM) measured at 662 keV.
As the greatest impact of this work, a gamma-ray detection efficiency on the
order of $10^{-4}$ was achieved at the sub-MeV gamma-ray band, which is one
order of magnitude higher than our previous experiment. This angular resolution
and detection efficiency enables us to detect the Crab Nebula at the 5 sigma
level with several hours observation at balloon altitude in middle latitude.
Furthermore, good consistency of efficiencies between this performance test and
simulation including only physical processes has a large importance; it means
we achieve nearly 100% detection of Compton recoil electrons. Thus, our
estimation of enhancements by upgrades of the detector is more dependable. We
are planning to confirm the imaging capability of the ETCC by observation of
celestial objects in the SMILE-II (Sub-MeV gamma ray Imaging Loaded-on-balloon
Experiment II). The SMILE-II and following SMILE-III project will be an
important key of sub-MeV/MeV gamma-ray astronomy.
[31]
oai:arXiv.org:1212.6153 [pdf] - 753387
Search for solar axions in XMASS, a large liquid-xenon detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-12-26, last modified: 2013-05-29
XMASS, a low-background, large liquid-xenon detector, was used to search for
solar axions that would be produced by bremsstrahlung and Compton effects in
the Sun. With an exposure of 5.6ton days of liquid xenon, the model-independent
limit on the coupling for mass $\ll$ 1keV is $|g_{aee}|< 5.4\times 10^{-11}$
(90% C.L.), which is a factor of two stronger than the existing experimental
limit. The bounds on the axion masses for the DFSZ and KSVZ axion models are
1.9 and 250eV, respectively. In the mass range of 10-40keV, this study produced
the most stringent limit, which is better than that previously derived from
astrophysical arguments regarding the Sun to date.
[32]
oai:arXiv.org:1211.5404 [pdf] - 620998
Light WIMP search in XMASS
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Suzuki, A. Shinozaki Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Masuda, K.;
Nishitani, Y.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2012-11-22, last modified: 2013-01-16
A search for light dark matter using low-threshold data from the single phase
liquid xenon scintillation detector XMASS, has been conducted. Using the entire
835 kg inner volume as target, the analysis threshold can be lowered to 0.3
keVee (electron-equivalent) to search for light dark matter. With low-threshold
data corresponding to a 5591.4 kg$\cdot$day exposure of the detector and
without discriminating between nuclear-recoil and electronic events, XMASS
excludes part of the parameter space favored by other experiments.
[33]
oai:arXiv.org:1301.2815 [pdf] - 831840
XMASS detector
Abe, K.;
Hieda, K.;
Hiraide, K.;
Hirano, S.;
Kishimoto, Y.;
Kobayashi, K.;
Moriyama, S.;
Nakagawa, K.;
Nakahata, M.;
Nishiie, H.;
Ogawa, H.;
Oka, N.;
Sekiya, H.;
Shinozaki, A.;
Suzuki, Y.;
Takeda, A.;
Takachio, O.;
Ueshima, K.;
Umemoto, D.;
Yamashita, M.;
Yang, B. S.;
Tasaka, S.;
Liu, J.;
Martens, K.;
Hosokawa, K.;
Miuchi, K.;
Murata, A.;
Onishi, Y.;
Otsuka, Y.;
Takeuchi, Y.;
Kim, Y. H.;
Lee, K. B.;
Lee, M. K.;
Lee, J. S.;
Fukuda, Y.;
Itow, Y.;
Nishitani, Y.;
Masuda, K.;
Takiya, H.;
Uchida, H.;
Kim, N. Y.;
Kim, Y. D.;
Kusaba, F.;
Motoki, D.;
Nishijima, K.;
Fujii, K.;
Murayama, I.;
Nakamura, S.
Submitted: 2013-01-13
The XMASS project aims to detect dark matter, pp and $^{7}$Be solar
neutrinos, and neutrinoless double beta decay using ultra pure liquid xenon.
The first phase of the XMASS experiment searches for dark matter. In this
paper, we describe the XMASS detector in detail, including its configuration,
data acquisition equipment and calibration system.
[34]
oai:arXiv.org:1109.3099 [pdf] - 1084087
NEWAGE
Miuchi, Kentaro;
Nakamura, Kiseki;
Takada, Atsushi;
Iwaki, Satoshi;
Kubo, Hidetoshi;
Mizumoto, Tetsuya;
Nishimura, Hironobu;
Parker, Joseph;
Sawano, Tatsuya;
Tanimori, Toru;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Fusayasu, Takahiro;
Sugiyama, Akira;
Tanaka, Manobu
Submitted: 2011-09-14, last modified: 2011-09-15
NEWAGE is a direction-sensitive dark matter search experiment with a gaseous
time-projection chamber. We improved the direction-sensitive dark matter limits
by our underground measurement. After the first underground run, we replaced
the detector components with radio-pure materials. We also studied the
possibilities of head-tail recognition of nuclear tracks in the surface
laboratory. For the future large volume detector, we are developing a pixel
ASIC named QPIX. In this paper, these recent R&D activities are described.
[35]
oai:arXiv.org:1103.3436 [pdf] - 966507
Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon
Altitudes with an Electron-tracking Compton Camera
Takada, Atsushi;
Kubo, Hidetoshi;
Nishimura, Hironobu;
Ueno, Kazuki;
Hattori, Kaori;
Kabuki, Shigeto;
Kurosawa, Shunsuke;
Miuchi, Kentaro;
Mizuta, Eiichi;
Nagayoshi, Tsutomu;
Nonaka, Naoki;
Okada, Yoko;
Orito, Reiko;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Tanimori, Toru
Submitted: 2011-03-17, last modified: 2011-03-23
We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes
with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as
the first step toward a future all-sky survey with a high sensitivity. SMILE-I
employed an electron-tracking Compton camera comprised of a gaseous electron
tracker as a Compton-scattering target and a scintillation camera as an
absorber. The balloon carrying the SMILE-I detector was launched from the
Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan
Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8
hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the
level flight, we successfully detected 420 downward gamma rays between 100 keV
and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse
cosmic gamma rays, we first simulated their scattering in the atmosphere using
Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we
found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV,
respectively, were scattered in the atmosphere prior to reaching the detector.
Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation
model, we estimated that the detected events consisted of diffuse cosmic and
atmospheric gamma rays (79%), secondary photons produced in the instrument
through the interaction between cosmic rays and materials surrounding the
detector (19%), and other particles (2%). The obtained growth curve was
comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric
gamma rays were consistent with the results of previous experiments. The
expected detection sensitivity of a future SMILE experiment measuring gamma
rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was
found to be ten times better than that of other experiments at around 1 MeV.
[36]
oai:arXiv.org:1002.1794 [pdf] - 1025066
First underground results with NEWAGE-0.3a direction-sensitive dark
matter detector
Miuchi, Kentaro;
Nishimura, Hironobu;
Hattori, Kaori;
Higashi, Naoki;
Ida, Chihiro;
Iwaki, Satoshi;
Kabuki, Shigeto;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Nakamura, Kiseki;
Parker, Joseph;
Sawano, Tatsuya;
Takahashi, Michiaki;
Tanimori, Toru;
Taniue, Kojiro;
Ueno, Kazuki;
Sekiya, Hiroyuki;
Takeda, Atsushi;
Tsuchiya, Ken'ichi;
Takada, Atsushi
Submitted: 2010-02-09
A direction-sensitive dark matter search experiment at Kamioka underground
laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a
detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152
Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg,
respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly
interacting massive particle (WIMP)-proton cross section limits by a
direction-sensitive method were achieved including a new record of 5400 pb for
150 GeV/c2 WIMPs. We studied the remaining background and found that ambient
gamma-rays contributed about one-fifth of the remaining background and
radioactive contaminants inside the gas chamber contributed the rest.
[37]
oai:arXiv.org:0911.0323 [pdf] - 902277
The case for a directional dark matter detector and the status of
current experimental efforts
Ahlen, S.;
Afshordi, N.;
Battat, J. B. R.;
Billard, J.;
Bozorgnia, N.;
Burgos, S.;
Caldwell, T.;
Carmona, J. M.;
Cebrian, S.;
Colas, P.;
Dafni, T.;
Daw, E.;
Dujmic, D.;
Dushkin, A.;
Fedus, W.;
Ferrer, E.;
Finkbeiner, D.;
Fisher, P. H.;
Forbes, J.;
Fusayasu, T.;
Galan, J.;
Gamble, T.;
Ghag, C.;
Giomataris, I.;
Gold, M.;
Gomez, H.;
Gomez, M. E.;
Gondolo, P.;
Green, A.;
Grignon, C.;
Guillaudin, O.;
Hagemann, C.;
Hattori, K.;
Henderson, S.;
Higashi, N.;
Ida, C.;
Iguaz, F. J.;
Inglis, A.;
Irastorza, I. G.;
Iwaki, S.;
Kaboth, A.;
Kabuki, S.;
Kadyk, J.;
Kallivayalil, N.;
Kubo, H.;
Kurosawa, S.;
Kudryavtsev, V. A.;
Lamy, T.;
Lanza, R.;
Lawson, T. B.;
Lee, A.;
Lee, E. R.;
Lin, T.;
Loomba, D.;
Lopez, J.;
Luzon, G.;
Manobu, T.;
Martoff, J.;
Mayet, F.;
Mccluskey, B.;
Miller, E.;
Miuchi, K.;
Monroe, J.;
Morgan, B.;
Muna, D.;
Murphy, A. St. J.;
Naka, T.;
Nakamura, K.;
Nakamura, M.;
Nakano, T.;
Nicklin, G. G.;
Nishimura, H.;
Niwa, K.;
Paling, S. M.;
Parker, J.;
Petkov, A.;
Pipe, M.;
Pushkin, K.;
Robinson, M.;
Rodriguez, A.;
Rodriguez-Quintero, J.;
Sahin, T.;
Sanderson, R.;
Sanghi, N.;
Santos, D.;
Sato, O.;
Sawano, T.;
Sciolla, G.;
Sekiya, H.;
Slatyer, T. R.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Takada, A.;
Takahashi, M.;
Takeda, A.;
Tanimori, T.;
Taniue, K.;
Tomas, A.;
Tomita, H.;
Tsuchiya, K.;
Turk, J.;
Tziaferi, E.;
Ueno, K.;
Vahsen, S.;
Vanderspek, R.;
Vergados, J.;
Villar, J. A.;
Wellenstein, H.;
Wolfe, I.;
Yamamoto, R. K.;
Yegoryan, H.
Submitted: 2009-11-01
We present the case for a dark matter detector with directional sensitivity.
This document was developed at the 2009 CYGNUS workshop on directional dark
matter detection, and contains contributions from theorists and experimental
groups in the field. We describe the need for a dark matter detector with
directional sensitivity; each directional dark matter experiment presents their
project's status; and we close with a feasibility study for scaling up to a one
ton directional detector, which would cost around $150M.
[38]
oai:arXiv.org:0708.2579 [pdf] - 4090
Direction-sensitive dark matter search results in a surface laboratory
Miuchi, Kentaro;
Hattori, Kaori;
Kabuki, Shigeto;
Kubo, Hidetoshi;
Kurosawa, Shunsuke;
Nishimura, Hironobu;
Okada, Yoko;
Takada, Atsushi;
Tanimori, Toru;
Tsuchiya, Ken'ichi;
Ueno, Kazuki;
Sekiya, Hiroyuki;
Takeda, Atsushi
Submitted: 2007-08-19
We developed a three-dimensional gaseous tracking device and performed a
direction-sensitive dark matter search in a surface laboratory. By using 150
Torr carbon-tetrafluoride (CF_4 gas), we obtained a sky map drawn with the
recoil directions of the carbon and fluorine nuclei, and set the first limit on
the spin-dependent WIMP (Weakly Interacting Massive Particles)-proton cross
section by a direction-sensitive method. Thus, we showed that a WIMP-search
experiment with a gaseous tracking device can actually set limits. Furthermore,
we demonstrated that this method will potentially play a certain role in
revealing the nature of dark matter when a low-background large-volume detector
is developed.
[39]
oai:arXiv.org:astro-ph/0601568 [pdf] - 79426
Development of Gaseous Tracking Devices for the Search of WIMPs
Sekiya, H.;
Hattori, K.;
Kabuki, S.;
Kubo, H.;
Miuchi, K.;
Nagayoshi, T.;
Nishimura, H.;
Okada, Y.;
Orito, R.;
Takada, A.;
Takeda, A.;
Tanimori, T.;
Ueno, K.
Submitted: 2006-01-25, last modified: 2006-02-14
The Time Projection Chamber (TPC) has been recognized as a potentially
powerful detector for the search of WIMPs by measuring the directions of
nuclear recoils, in which the most convincing signature of WIMPs, caused by the
Earth's motion around the Galaxy, appears.
We report on the first results of a performance study of the neutron exposure
of our prototype micro-TPC with Ar-C$_2$H$_6$ (90:10) and CF$_4$ gas of 150
Torr.
[40]
oai:arXiv.org:astro-ph/0412047 [pdf] - 69451
Development of an advanced Compton camera with gaseous TPC and
scintillator
Takada, A.;
Hattori, K.;
Kubo, H.;
Miuchi, K.;
Nagayoshi, T.;
Nishimura, H.;
Okada, Y.;
Orito, R.;
Sekiya, H.;
Takeda, A.;
Tanimori, T.
Submitted: 2004-12-02
A prototype of the MeV gamma-ray imaging camera based on the full
reconstruction of the Compton process has been developed. This camera consists
of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and
scintillation cameras. With the information of the recoil electrons and the
scattered gamma-rays, this camera detects the energy and incident direction of
each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera
with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing
the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM
(Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV
gamma-rays were $18^\circ$ and $35^\circ$, respectively.
[41]
oai:arXiv.org:astro-ph/0403518 [pdf] - 63709
MeV Gamma-Ray Imaging Detector with micro-TPC
Submitted: 2004-03-22
We propose a new imaging gamma-ray detector in the MeV region. By measuring
the directions and energies of not only a scattered gamma ray but also a recoil
electron, the direction of an incident gamma ray would be essentially
reconstructed event by event. Furthermore, one of two measured (zenith and
azimuth) angles of a recoil electron gives us an additional redundancy which
enables us to reject the background events by kinematic constraints. In order
to measure the track of a recoil electron, the micro Time Projection
Chamber($\mu$-TPC) has been developed, which can measure the successive
positions of the track of charged particles in a few hundred micron meter
pitch. The $\mu$-TPC consists of the new type of a gas proportional chamber:
micro PIxel gas Chamber ($\mu$-PIC) which is one of wireless gas chambers and
expected to be robust and stable. Using this $\mu$-TPC and the Anger camera for
the detection of a scattered gamma ray, we have obtained the first gamma-ray
image by the full reconstruction of the direction of gamma rays event by event.
[42]
oai:arXiv.org:astro-ph/0310638 [pdf] - 880671
Detecting the WIMP-wind via spin-dependent interactions
Submitted: 2003-10-22
Revealing the nature of dark matter is one of the most interesting tasks in
astrophysics. Measuring the distribution of recoil angles is said to be one of
the most reliable methods to detect a positive signature of dark matter. We
focused on measurements via spin-dependent interactions, and studied the
feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into
account the performance of an existing three-dimensional tracking detector. We
consequently found that it is highly possible to detect a positive signature of
dark matter via spin-dependent interactions.
[43]
oai:arXiv.org:astro-ph/0306365 [pdf] - 57446
Limits on the WIMP-Nucleon Coupling Coefficients from Dark Matter Search
Experiment with NaF Bolometer
Submitted: 2003-06-18, last modified: 2003-10-08
We have performed the underground dark matter search experiment with a sodium
fl uoride (NaF) bolometer array from 2002 through 2003 at Kamioka Observatory
(2700 m.w.e.). The bolometer array consists of eight NaF absorbers with a total
mass of 176 g, and sensitive NTD germanium thermistors glued to each of them.
This experiment aims for the direct detection of weakly interacting massive
part icles (WIMPs) via spin-dependent interaction. With an exposure of 3.38 kg
days, we derived the limits on the WIMP-n ucleon coupling coefficients, a_p and
a_n. These limits confirmed and tightened those derived from our previous
results wit h the lithium fluoride (LiF) bolometer. Our results excluded the
parameter space complementary to the results obtained b y NaI detectors of
UKDMC experiment.
[44]
oai:arXiv.org:hep-ex/0301012 [pdf] - 113348
Performance of the TPC with Micro Pixel Chamber Readout: micro-TPC
Submitted: 2003-01-10, last modified: 2003-04-02
Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC)
readout was developed for the detection of the three-dimensional fine(sub-m
illimeter) tracks of charged particles. We developed a two-dimensional position
sensitive gaseous detector, or the $\mu$-PIC, with the detection area of
10$\times$10 cm${}^{2}$ and 65536 anode electrodes of 400 $\mu$m pitch. We
achieved the gas gain of over 10000 without any other multipliers. With the
pipe-line readout system specially developed for the $\mu$-PIC, we detected
X-rays at the rate as high as 7.7 Mcps. We attached a drift cage with an 8 cm
drift length to the $\mu$-PIC and developed a micro-TPC. We measured the basic
performances of the micro-TPC and took three-dimensional tracks of electrons.
We also developed a prototype of the MeV gamma-ray imaging detector which is a
hybrid of the micro-TPC and NaI(Tl) scintillators and confirmed its concept by
reconstructing the obtained data.
[45]
oai:arXiv.org:astro-ph/0204411 [pdf] - 48956
First results from dark matter search experiment with LiF bolometer at
Kamioka Underground Laboratory
Submitted: 2002-04-24, last modified: 2003-02-17
Tokyo group has performed first underground dark matter search experiment in
2001 through 2002 at Kamioka Observatory(2700m.w.e). The detector is eight LiF
bolometers with total mass 168g aiming for the direct detection of WIMPs via
spin-dependent interaction. With a total exposure of 4.1 kg days, we derived
the limits in the a_p-a_n (WIMP-nucleon couplings) plane and excluded a large
part of the parameter space allowed by the UKDMC experiment.