Normalized to: Mirel, P.
[1]
oai:arXiv.org:1909.06440 [pdf] - 1961730
Sub-Kelvin cooling for two kilopixel bolometer arrays in the PIPER
receiver
Switzer, E. R.;
Ade, P. A. R.;
Baildon, T.;
Benford, D.;
Bennett, C. L.;
Chuss, D. T.;
Datta, R.;
Eimer, J. R.;
Fixsen, D. J.;
Gandilo, N. N.;
Essinger-Hileman, T. M.;
Halpern, M.;
Hilton, G.;
Irwin, K.;
Jhabvala, C.;
Kimball, M.;
Kogut, A.;
Lazear, J.;
Lowe, L. N.;
McMahon, J. J.;
Miller, T. M.;
Mirel, P.;
Moseley, S. H.;
Pawlyk, S.;
Rodriguez, S.;
Sharp, E.;
Shirron, P.;
Staguhn, J. G.;
Sullivan, D. F.;
Taraschi, P.;
Tucker, C. E.;
Walts, A.;
Wollack, E. J.
Submitted: 2019-09-13
The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne
telescope mission to search for inflationary gravitational waves from the early
universe. PIPER employs two 32x40 arrays of superconducting transition-edge
sensors, which operate at 100 mK. An open bucket dewar of liquid helium
maintains the receiver and telescope optics at 1.7 K. We describe the thermal
design of the receiver and sub-kelvin cooling with a continuous adiabatic
demagnetization refrigerator (CADR). The CADR operates between 70-130 mK and
provides ~10 uW cooling power at 100 mK, nearly five times the loading of the
two detector assemblies. We describe electronics and software to robustly
control the CADR, overall CADR performance in flight-like integrated receiver
testing, and practical considerations for implementation in the balloon float
environment.
[2]
oai:arXiv.org:1607.06172 [pdf] - 1531076
The Primordial Inflation Polarization Explorer (PIPER)
Gandilo, Natalie N.;
Ade, Peter A. R.;
Benford, Dominic;
Bennett, Charles L.;
Chuss, David T.;
Dotson, Jessie L.;
Eimer, Joseph R.;
Fixsen, Dale J.;
Halpern, Mark;
Hilton, Gene;
Hinshaw, Gary F.;
Irwin, Kent;
Jhabvala, Christine;
Kimball, Mark;
Kogut, Alan;
Lowe, Luke;
McMahon, Jeff J.;
Miller, Timothy M.;
Mirel, Paul;
Moseley, S. Harvey;
Pawlyk, Samuel;
Rodriguez, Samelys;
Sharp, Elmer;
Shirron, Peter;
Staguhn, Johannes G.;
Sullivan, Dan F.;
Switzer, Eric R.;
Taraschi, Peter;
Tucker, Carole E.;
Wollack, Edward J.
Submitted: 2016-07-20
The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne
telescope designed to measure the polarization of the Cosmic Microwave
Background on large angular scales. PIPER will map 85% of the sky at 200, 270,
350, and 600 GHz over a series of 8 conventional balloon flights from the
northern and southern hemispheres. The first science flight will use two 32x40
arrays of backshort-under-grid transition edge sensors, multiplexed in the time
domain, and maintained at 100 mK by a Continuous Adiabatic Demagnetization
Refrigerator. Front-end cryogenic Variable-delay Polarization Modulators
provide systematic control by rotating linear to circular polarization at 3 Hz.
Twin telescopes allow PIPER to measure Stokes I, Q, U, and V simultaneously.
The telescope is maintained at 1.5 K in an LHe bucket dewar. Cold optics and
the lack of a warm window permit sensitivity at the sky-background limit. The
ultimate science target is a limit on the tensor-to-scalar ratio of r ~ 0.007,
from the reionization bump to l ~ 300. PIPER's first flight will be from the
Northern hemisphere, and overlap with the CLASS survey at lower frequencies. We
describe the current status of the PIPER instrument.
[3]
oai:arXiv.org:1407.2584 [pdf] - 1215558
The Primordial Inflation Polarization Explorer (PIPER)
Lazear, Justin;
Ade, Peter A. R.;
Benford, Dominic;
Bennett, Charles L.;
Chuss, David T.;
Dotson, Jessie L.;
Eimer, Joseph R.;
Fixsen, Dale J.;
Halpern, Mark;
Hilton, Gene;
Hinderks, James;
Hinshaw, Gary F.;
Irwin, Kent;
Jhabvala, Christine;
Johnson, Bradley;
Kogut, Alan;
Lowe, Luke;
McMahon, Jeff J.;
Miller, Timothy M.;
Mirel, Paul;
Moseley, S. Harvey;
Rodriguez, Samelys;
Sharp, Elmer;
Staguhn, Johannes G.;
Switzer, Eric R.;
Tucker, Carole E.;
Weston, Amy;
Wollack, Edward J.
Submitted: 2014-07-09
The Primordial Inflation Polarization Explorer (PIPER) is a balloon-borne
cosmic microwave background (CMB) polarimeter designed to search for evidence
of inflation by measuring the large-angular scale CMB polarization signal.
BICEP2 recently reported a detection of B-mode power corresponding to the
tensor-to-scalar ratio r = 0.2 on ~2 degree scales. If the BICEP2 signal is
caused by inflationary gravitational waves (IGWs), then there should be a
corresponding increase in B-mode power on angular scales larger than 18
degrees. PIPER is currently the only suborbital instrument capable of fully
testing and extending the BICEP2 results by measuring the B-mode power spectrum
on angular scales $\theta$ = ~0.6 deg to 90 deg, covering both the reionization
bump and recombination peak, with sensitivity to measure the tensor-to-scalar
ratio down to r = 0.007, and four frequency bands to distinguish foregrounds.
PIPER will accomplish this by mapping 85% of the sky in four frequency bands
(200, 270, 350, 600 GHz) over a series of 8 conventional balloon flights from
the northern and southern hemispheres. The instrument has background-limited
sensitivity provided by fully cryogenic (1.5 K) optics focusing the sky signal
onto four 32x40-pixel arrays of time-domain multiplexed Transition-Edge Sensor
(TES) bolometers held at 140 mK. Polarization sensitivity and systematic
control are provided by front-end Variable-delay Polarization Modulators
(VPMs), which rapidly modulate only the polarized sky signal at 3 Hz and allow
PIPER to instantaneously measure the full Stokes vector (I, Q, U, V) for each
pointing. We describe the PIPER instrument and progress towards its first
flight.
[4]
oai:arXiv.org:1403.1652 [pdf] - 1208233
Variable-delay Polarization Modulators for Cryogenic Millimeter-wave
Applications
Chuss, David T.;
Eimer, Joseph R.;
Fixsen, Dale J.;
Hinderks, James;
Kogut, Alan J.;
Lazear, Justin;
Mirel, Paul;
Switzer, Eric;
Voellmer, George M.;
Wollack, Edward J.
Submitted: 2014-03-06, last modified: 2014-05-28
We describe the design, construction, and initial validation of the
variable-delay polarization modulator (VPM) designed for the PIPER cosmic
microwave background polarimeter. The VPM modulates between linear and circular
polarization by introducing a variable phase delay between orthogonal linear
polarizations. Each VPM has a diameter of 39 cm and is engineered to operate in
a cryogenic environment (1.5 K). We describe the mechanical design and
performance of the kinematic double-blade flexure and drive mechanism along
with the construction of the high precision wire grid polarizers.
[5]
oai:arXiv.org:0901.0546 [pdf] - 332879
The ARCADE 2 Instrument
Singal, J.;
Fixsen, D. J.;
Kogut, A.;
Levin, S.;
Limon, M.;
Lubin, P.;
Mirel, P.;
Seiffert, M.;
Villela, T.;
Wollack, E.;
Wuensche, C. A.
Submitted: 2009-01-05, last modified: 2010-04-02
The second generation Absolute Radiometer for Cosmology, Astrophysics, and
Diffuse Emission (ARCADE 2) instrument is a balloon-borne experiment to measure
the radiometric temperature of the cosmic microwave background and Galactic and
extra-Galactic emission at six frequencies from 3 to 90 GHz. ARCADE 2 utilizes
a double-nulled design where emission from the sky is compared to that from an
external cryogenic full-aperture blackbody calibrator by cryogenic switching
radiometers containing internal blackbody reference loads. In order to further
minimize sources of systematic error, ARCADE 2 features a cold fully open
aperture with all radiometrically active components maintained at near 2.7 K
without windows or other warm objects, achieved through a novel thermal design.
We discuss the design and performance of the ARCADE 2 instrument in its 2005
and 2006 flights.
[6]
oai:arXiv.org:0901.0562 [pdf] - 362611
ARCADE 2 Observations of Galactic Radio Emission
Kogut, A.;
Fixsen, D. J.;
Levin, S. M.;
Limon, M.;
Lubin, P. M.;
Mirel, P.;
Seiffert, M.;
Singal, J.;
Villela, T.;
Wollack, E.;
Wuensche, C. A.
Submitted: 2009-01-05
We use absolutely calibrated data from the ARCADE 2 flight in July 2006 to
model Galactic emission at frequencies 3, 8, and 10 GHz. The spatial structure
in the data is consistent with a superposition of free-free and synchrotron
emission. Emission with spatial morphology traced by the Haslam 408 MHz survey
has spectral index beta_synch = -2.5 +/- 0.1, with free-free emission
contributing 0.10 +/- 0.01 of the total Galactic plane emission in the lowest
ARCADE 2 band at 3.15 GHz. We estimate the total Galactic emission toward the
polar caps using either a simple plane-parallel model with csc|b| dependence or
a model of high-latitude radio emission traced by the COBE/FIRAS map of CII
emission. Both methods are consistent with a single power-law over the
frequency range 22 MHz to 10 GHz, with total Galactic emission towards the
north polar cap T_Gal = 0.498 +/- 0.028 K and spectral index beta = -2.55 +/-
0.03 at reference frequency 1 GHz. The well calibrated ARCADE 2 maps provide a
new test for spinning dust emission, based on the integrated intensity of
emission from the Galactic plane instead of cross-correlations with the thermal
dust spatial morphology. The Galactic plane intensity measured by ARCADE 2 is
fainter than predicted by models without spinning dust, and is consistent with
spinning dust contributing 0.4 +/- 0.1 of the Galactic plane emission at 22
GHz.
[7]
oai:arXiv.org:0901.0559 [pdf] - 19994
Interpretation of the Extragalactic Radio Background
Seiffert, M.;
Fixsen, D. J.;
Kogut, A.;
Levin, S. M.;
Limon, M.;
Lubin, P. M.;
Mirel, P.;
Singal, J.;
Villela, T.;
Wollack, E.;
Wuensche, C. A.
Submitted: 2009-01-05
We use absolutely calibrated data between 3 and 90 GHz from the 2006 balloon
flight of the ARCADE 2 instrument, along with previous measurements at other
frequencies, to constrain models of extragalactic emission. Such emission is a
combination of the Cosmic Microwave Background (CMB) monopole, Galactic
foreground emission, the integrated contribution of radio emission from
external galaxies, any spectral distortions present in the CMB, and any other
extragalactic source. After removal of estimates of foreground emission from
our own Galaxy, and the estimated contribution of external galaxies, we present
fits to a combination of the flat-spectrum CMB and potential spectral
distortions in the CMB. We find 2 sigma upper limits to CMB spectral
distortions of mu < 5.8 x 10^{-5} and Y_ff < 6.2 x 10^{-5}. We also find a
significant detection of a residual signal beyond that which can be explained
by the CMB plus the integrated radio emission from galaxies estimated from
existing surveys. After subtraction of an estimate of the contribution of
discrete radio sources, this unexplained signal is consistent with
extragalactic emission in the form of a power law with amplitude 1.06 \pm 0.11
K at 1 GHz and a spectral index of -2.56 \pm 0.04.
[8]
oai:arXiv.org:0901.0555 [pdf] - 1490614
ARCADE 2 Measurement of the Extra-Galactic Sky Temperature at 3-90 GHz
Fixsen, D. J.;
Kogut, A.;
Levin, S.;
Limon, M.;
Lubin, P.;
Mirel, P.;
Seiffert, M.;
Singal, J.;
Wollack, E.;
Villela, T.;
Wuensche, C. A.
Submitted: 2009-01-05
The ARCADE 2 instrument has measured the absolute temperature of the sky at
frequencies 3, 8, 10, 30, and 90 GHz, using an open-aperture cryogenic
instrument observing at balloon altitudes with no emissive windows between the
beam-forming optics and the sky. An external blackbody calibrator provides an
{\it in situ} reference. Systematic errors were greatly reduced by using
differential radiometers and cooling all critical components to physical
temperatures approximating the CMB temperature. A linear model is used to
compare the output of each radiometer to a set of thermometers on the
instrument. Small corrections are made for the residual emission from the
flight train, balloon, atmosphere, and foreground Galactic emission. The ARCADE
2 data alone show an extragalactic rise of $50\pm7$ mK at 3.3 GHz in addition
to a CMB temperature of $2.730\pm .004$ K. Combining the ARCADE 2 data with
data from the literature shows a background power law spectrum of $T=1.26\pm
0.09$ [K] $(\nu/\nu_0)^{-2.60\pm 0.04}$ from 22 MHz to 10 GHz ($\nu_0=1$ GHz)
in addition to a CMB temperature of $2.725\pm .001$ K.
[9]
oai:arXiv.org:astro-ph/0609373 [pdf] - 84965
ARCADE: Absolute Radiometer for Cosmology, Astrophysics, and Diffuse
Emission
Kogut, A.;
Fixsen, D.;
Fixsen, S.;
Levin, S.;
Limon, M.;
Lowe, L.;
Mirel, P.;
Seiffert, M.;
Singal, J.;
Lubin, P.;
Wollack, E.
Submitted: 2006-09-13
The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission
(ARCADE) is a balloon-borne instrument designed to measure the temperature of
the cosmic microwave background at centimeter wavelengths. ARCADE searches for
deviations from a blackbody spectrum resulting from energy releases in the
early universe. Long-wavelength distortions in the CMB spectrum are expected in
all viable cosmological models. Detecting these distortions or showing that
they do not exist is an important step for understanding the early universe. We
describe the ARCADE instrument design, current status, and future plans.
[10]
oai:arXiv.org:astro-ph/0402580 [pdf] - 63094
Design and Calibration of a Cryogenic Blackbody Calibrator at Centimeter
Wavelengths
Submitted: 2004-02-24
We describe the design and calibration of an external cryogenic blackbody
calibrator used for the first two flights of the Absolute Radiometer for
Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The
calibrator consists of a microwave absorber weakly coupled to a superfluid
liquid helium bath. Half-wave corrugations viewed 30 deg off axis reduce the
return loss below -35 dB. Ruthenium oxide resistive thermometers embedded
within the absorber monitor the temperature across the face of the calibrator.
The thermal calibration transfers the calibration of a reference thermometer to
the flight thermometers using the flight thermometer readout system. Data taken
near the superfluid transition in 8 independent calibrations 4 years apart
agree within 0.3 mK, providing an independent verification of the thermometer
calibration at temperatures near that of the cosmic microwave background.
[11]
oai:arXiv.org:astro-ph/0402579 [pdf] - 63093
The Temperature of the CMB at 10 GHz
Submitted: 2004-02-24
We report the results of an effort to measure the low frequency portion of
the spectrum of the Cosmic Microwave Background Radiation (CMB), using a
balloon-borne instrument called ARCADE (Absolute Radiometer for Cosmology,
Astrophysics, and Diffuse Emission). These measurements are to search for
deviations from a thermal spectrum that are expected to exist in the CMB due to
various processes in the early universe. The radiometric temperature was
measured at 10 and 30 GHz using a cryogenic open-aperture instrument with no
emissive windows. An external blackbody calibrator provides an in situ
reference. A linear model is used to compare the radiometer output to a set of
thermometers on the instrument. The unmodeled residuals are less than 50 mK
peak-to-peak with a weighted RMS of 6 mK. Small corrections are made for the
residual emission from the flight train, atmosphere, and foreground Galactic
emission. The measured radiometric temperature of the CMB is 2.721 +/- 0.010 K
at 10 GHz and 2.694 +/- 0.032 K at 30 GHz.
[12]
oai:arXiv.org:astro-ph/0402578 [pdf] - 63092
An Instrument to Measure the Temperature of the Cosmic Microwave
Background Radiation at Centimeter Wavelengths
Submitted: 2004-02-24
The Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission
(ARCADE) is a balloon-borne instrument to measure the temperature of the cosmic
microwave background at centimeter wavelengths. ARCADE uses narrow-band
cryogenic radiometers to compare the sky to an external full-aperture
calibrator. To minimize potential sources of systematic error, ARCADE uses a
novel open-aperture design which maintains the antennas and calibrator at
temperatures near 3 K at the mouth of an open bucket Dewar, without windows or
other warm objects between the antennas and the sky. We discuss the design and
performance of the ARCADE instrument from its 2001 and 2003 flights.
[13]
oai:arXiv.org:astro-ph/0208585 [pdf] - 51401
A Low Noise Thermometer Readout for Ruthenium Oxide Resistors
Submitted: 2002-08-30
The thermometer and thermal control system, for the Absolute Radiometer for
Cosmology, Astrophysics, and Diffuse Emission (ARCADE) experiment, is
described, including the design, testing, and results from the first flight of
ARCADE. The noise is equivalent to about 1 Omega or 0.15 mK in a second for the
RuO_2 resistive thermometers at 2.7 K. The average power dissipation in each
thermometer is 1 nW. The control system can take full advantage of the
thermometers to maintain stable temperatures. Systematic effects are still
under investigation, but the measured precision and accuracy are sufficient to
allow measurement of the cosmic background spectrum.
Journal-ref: Review of Scientific Instruments Vol 73 #10 (Oct 2002)