[1]  oai:arXiv.org:1910.13957  [pdf] - 2097246
The TREX-DM experiment at the Canfranc Underground Laboratory
Comments: TAUP2019 proceedings
Submitted: 2019-10-30, last modified: 2020-03-22
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly presented.
[2]  oai:arXiv.org:1812.04519  [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Comments: Final version, as accepted in Eur. Phys. J. C
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[3]  oai:arXiv.org:1706.05818  [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Comments: Final version as published
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
[4]  oai:arXiv.org:1709.10062  [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Comments: To appear in the Proceedings of the XV International Conference on Topics in Astroparticle and Underground Physics (TAUP2017) at Journal of Physics: Conference Series (JPCS)
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
[5]  oai:arXiv.org:1610.02396  [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Comments: 58 pages, 26 figures, accepted by Physics Reports
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
[6]  oai:arXiv.org:1509.06190  [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Comments: 21 pages, 16 figures
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.