Normalized to: Mirallas, H.
[1]
oai:arXiv.org:1910.13957 [pdf] - 2097246
The TREX-DM experiment at the Canfranc Underground Laboratory
Castel, J;
Cebrián, S;
Dafni, T;
Galán, J;
Irastorza, IG;
Luzón, G;
Margalejo, C;
Mirallas, H;
de Solórzano, A Ortiz;
Peiró, A;
Ruiz-Chóliz, E
Submitted: 2019-10-30, last modified: 2020-03-22
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for
low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using
light elements (Ne, Ar) as target in a high pressure TPC equipped with
Micromegas readouts. Here, a description of the detector, the first results
from commissioning data and the expected sensitivity from the developed
background model are briefly presented.
[2]
oai:arXiv.org:1812.04519 [pdf] - 1983798
Background assessment for the TREX Dark Matter experiment
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Dafni, T.;
Galan, J.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Mirallas, H.;
de Solorzano, A. Ortiz;
Ruiz-Choliz, E.
Submitted: 2018-12-11, last modified: 2019-09-22
TREX-DM is conceived to look for low-mass Weakly Interacting Massive
Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas
readout planes at the Canfranc Underground Laboratory. The detector can hold in
the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30
kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered
acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low
background level in the lowest energy region is another essential requirement.
To assess the expected background, all the relevant sources have been
considered, including the measured fluxes of gamma radiation, muons and
neutrons at the Canfranc Laboratory, together with the activity of most of the
components used in the detector and ancillary systems, obtained in a complete
assay program. The background contributions have been simulated by means of a
dedicated application based on Geant4 and a custom-made code for the detector
response. The background model developed for the detector presently installed
in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region
of interest, making TREX-DM competitive in the search for low-mass WIMPs. A
roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
[3]
oai:arXiv.org:1706.05818 [pdf] - 1598065
Cosmogenic production of tritium in dark matter detectors
Amare, J.;
Castel, J.;
Cebrian, S.;
Coarasa, I.;
Cuesta, C.;
Dafni, T.;
Galan, J.;
Garcia, E.;
Garza, J. G.;
Iguaz, F. J.;
Irastorza, I. G.;
Luzon, G.;
Martinez, M.;
Mirallas, H.;
Olivan, M. A.;
Ortigoza, Y.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Ruiz-Choliz, E.;
Sarsa, M. L.;
Villar, J. A.;
Villar, P.
Submitted: 2017-06-19, last modified: 2017-11-24
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV. Radioactive isotopes are
produced via cosmogenic activation in detectors and other materials and those
isotopes constitute a background source which has to be under control. In
particular, tritium is specially relevant due to its decay properties (very low
endpoint energy and long half-life) when induced in the detector medium, and
because it can be generated in any material as a spallation product.
Quantification of cosmogenic production of tritium is not straightforward,
neither experimentally nor by calculations. In this work, a method for the
calculation of production rates at sea level has been developed and applied to
some of the materials typically used as targets in dark matter detectors
(germanium, sodium iodide, argon and neon); it is based on a selected
description of tritium production cross sections over the entire energy range
of cosmic nucleons. Results have been compared to available data in the
literature, either based on other calculations or from measurements. The
obtained tritium production rates, ranging from a few tens to a few hundreds of
nuclei per kg and per day at sea level, point to a significant contribution to
the background in dark matter experiments, requiring the application of
specific protocols for target material purification, material storing
underground and limiting the time the detector is on surface during the
building process in order to minimize the exposure to the most dangerous cosmic
ray components.
[4]
oai:arXiv.org:1709.10062 [pdf] - 1589033
Status of the TREX-DM experiment at the Canfranc Underground Laboratory
Aznar, F;
Castel, J;
Cebrian, S;
Coarasa, I;
Dafni, T;
Galan, J;
Garza, JG;
Iguaz, FJ;
Irastorza, IG;
Luzon, G;
Mirallas, H;
de Solorzano, A Ortiz;
Ruiz-Choliz, E;
Villar, JA
Submitted: 2017-09-28
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a
gas time projection chamber equipped with novel micromegas readout planes at
the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized
gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg
of Ne. The micromegas will be read with a self-triggered acquisition, allowing
for effective thresholds below 0.4 keV (electron equivalent). The preliminary
background model, following a complete material screening program, points to
levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest,
making TREX-DM competitive. The status of the commissioning, description of the
background model and the corresponding WIMP sensitivity will be presented here.
[5]
oai:arXiv.org:1610.02396 [pdf] - 1516330
Readout technologies for directional WIMP Dark Matter detection
Battat, J. B. R.;
Irastorza, I. G.;
Aleksandrov, A.;
Guler, M. Ali;
Asada, T.;
Baracchini, E.;
Billard, J.;
Bosson, G.;
Bourrion, O.;
Bouvier, J.;
Buonaura, A.;
Burdge, K.;
Cebrian, S.;
Colas, P.;
Consiglio, L.;
Dafni, T.;
D'Ambrosio, N.;
Deaconu, C.;
De Lellis, G.;
Descombes, T.;
Di Crescenzo, A.;
Di Marco, N.;
Druitt, G.;
Eggleston, R.;
Ferrer-Ribas, E.;
Fusayasu, T.;
Galan, J.;
Galati, G.;
Garcia, J. A.;
Garza, J. G.;
Gentile, V.;
Garcia-Sciveres, M.;
Giomataris, Y.;
Guerrero, N.;
Guillaudin, O.;
Harton, J.;
Hashimoto, T.;
Hedges, M. T.;
Iguaz, F.;
Ikeda, T.;
Jaegle, I.;
Kadyk, J. A.;
Katsuragawa, T.;
Komura, S.;
Kubo, H.;
Kuge, K.;
Lamblin, J.;
Lauria, A.;
Lee, E. R.;
Lewis, P.;
Leyton, M.;
Loomba, D.;
Lopez, J. P.;
Luzon, G.;
Mayet, F.;
Mirallas, H.;
Miuchi, K.;
Mizumoto, T.;
Mizumura, Y.;
Monacelli, P.;
Monroe, J.;
Montesi, M. C.;
Naka, T.;
Nakamura, K.;
Nishimura, H.;
Ochi, A.;
Papevangelou, T.;
Parker, J. D.;
Phan, N. S.;
Pupilli, F.;
Richer, J. P.;
Riffard, Q.;
Rosa, G.;
Santos, D.;
Sawano, T.;
Sekiya, H.;
Seong, I. S.;
Snowden-Ifft, D. P.;
Spooner, N. J. C.;
Sugiyama, A.;
Taishaku, R.;
Takada, A.;
Takeda, A.;
Tanaka, M.;
Tanimori, T.;
Thorpe, T. N.;
Tioukov, V.;
Tomita, H.;
Umemoto, A.;
Vahsen, S. E.;
Yamaguchi, Y.;
Yoshimoto, M.;
Zayas, E.
Submitted: 2016-10-06
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
[6]
oai:arXiv.org:1509.06190 [pdf] - 1323484
A Micromegas-based low-background x-ray detector coupled to a
slumped-glass telescope for axion research
Aznar, F.;
Castel, J.;
Christensen, F. E.;
Dafni, T.;
Decker, T. A.;
Ferrer-Ribas, E.;
Garcia, J. A.;
Giomataris, I.;
Gracia, J. G.;
Hailey, C. J.;
Hill, R. M.;
Iguaz, F. J.;
Irastorza, I. G.;
Jakobsen, A. C.;
Luzon, G.;
Mirallas, H.;
Papaevangelou, T.;
Pivovaroff, M. J.;
Ruz, J.;
Vafeiadis, T.;
Vogel, J. K.
Submitted: 2015-09-21
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.