Normalized to: Minuti, M.
[1]
oai:arXiv.org:1903.01619 [pdf] - 1864023
PolarLight: a CubeSat X-ray Polarimeter based on the Gas Pixel Detector
Feng, Hua;
Jiang, Weichun;
Minuti, Massimo;
Wu, Qiong;
Jung, Aera;
Yang, Dongxin;
Citraro, Saverio;
Nasimi, Hikmat;
Yu, Jiandong;
Jin, Ge;
Huang, Jiahui;
Zeng, Ming;
An, Peng;
Baldini, Luca;
Bellazzini, Ronaldo;
Brez, Alessandro;
Latronico, Luca;
Sgrò, Carmelo;
Spandre, Gloria;
Pinchera, Michele;
Muleri, Fabio;
Soffitta, Paolo;
Costa, Enrico
Submitted: 2019-03-04
The gas pixel detector (GPD) is designed and developed for high-sensitivity
astronomical X-ray polarimetry, which is a new window about to open in a few
years. Due to the small mass, low power, and compact geometry of the GPD, we
propose a CubeSat mission Polarimeter Light (PolarLight) to demonstrate and
test the technology directly in space. There is no optics but a collimator to
constrain the field of view to 2.3 degrees. Filled with pure dimethyl ether
(DME) at 0.8 atm and sealed by a beryllium window of 100 micron thick, with a
sensitive area of about 1.4 mm by 1.4 mm, PolarLight allows us to observe the
brightest X-ray sources on the sky, with a count rate of, e.g., ~0.2 counts/s
from the Crab nebula. The PolarLight is 1U in size and mounted in a 6U CubeSat,
which was launched into a low Earth Sun-synchronous orbit on October 29, 2018,
and is currently under test. More launches with improved designs are planned in
2019. These tests will help increase the technology readiness for future
missions such as the enhanced X-ray Timing and Polarimetry (eXTP), better
understand the orbital background, and may help constrain the physics with
observations of the brightest objects.
[2]
oai:arXiv.org:1812.04020 [pdf] - 1795995
The enhanced X-ray Timing and Polarimetry mission - eXTP
Zhang, ShuangNan;
Santangelo, Andrea;
Feroci, Marco;
Xu, YuPeng;
Lu, FangJun;
Chen, Yong;
Feng, Hua;
Zhang, Shu;
Brandt, Søren;
Hernanz, Margarita;
Baldini, Luca;
Bozzo, Enrico;
Campana, Riccardo;
De Rosa, Alessandra;
Dong, YongWei;
Evangelista, Yuri;
Karas, Vladimir;
Meidinger, Norbert;
Meuris, Aline;
Nandra, Kirpal;
Pan, Teng;
Pareschi, Giovanni;
Orleanski, Piotr;
Huang, QiuShi;
Schanne, Stephane;
Sironi, Giorgia;
Spiga, Daniele;
Svoboda, Jiri;
Tagliaferri, Gianpiero;
Tenzer, Christoph;
Vacchi, Andrea;
Zane, Silvia;
Walton, Dave;
Wang, ZhanShan;
Winter, Berend;
Wu, Xin;
Zand, Jean J. M. in 't;
Ahangarianabhari, Mahdi;
Ambrosi, Giovanni;
Ambrosino, Filippo;
Barbera, Marco;
Basso, Stefano;
Bayer, Jörg;
Bellazzini, Ronaldo;
Bellutti, Pierluigi;
Bertucci, Bruna;
Bertuccio, Giuseppe;
Borghi, Giacomo;
Cao, XueLei;
Cadoux, Franck;
Campana, Riccardo;
Ceraudo, Francesco;
Chen, TianXiang;
Chen, YuPeng;
Chevenez, Jerome;
Civitani, Marta;
Cui, Wei;
Cui, WeiWei;
Dauser, Thomas;
Del Monte, Ettore;
Di Cosimo, Sergio;
Diebold, Sebastian;
Doroshenko, Victor;
Dovciak, Michal;
Du, YuanYuan;
Ducci, Lorenzo;
Fan, QingMei;
Favre, Yannick;
Fuschino, Fabio;
Gálvez, José Luis;
Gao, Min;
Ge, MingYu;
Gevin, Olivier;
Grassi, Marco;
Gu, QuanYing;
Gu, YuDong;
Han, DaWei;
Hong, Bin;
Hu, Wei;
Ji, Long;
Jia, ShuMei;
Jiang, WeiChun;
Kennedy, Thomas;
Kreykenbohm, Ingo;
Kuvvetli, Irfan;
Labanti, Claudio;
Latronico, Luca;
Li, Gang;
Li, MaoShun;
Li, Xian;
Li, Wei;
Li, ZhengWei;
Limousin, Olivier;
Liu, HongWei;
Liu, XiaoJing;
Lu, Bo;
Luo, Tao;
Macera, Daniele;
Malcovati, Piero;
Martindale, Adrian;
Michalska, Malgorzata;
Meng, Bin;
Minuti, Massimo;
Morbidini, Alfredo;
Muleri, Fabio;
Paltani, Stephane;
Perinati, Emanuele;
Picciotto, Antonino;
Piemonte, Claudio;
Qu, JinLu;
Rachevski, Alexandre;
Rashevskaya, Irina;
Rodriguez, Jerome;
Schanz, Thomas;
Shen, ZhengXiang;
Sheng, LiZhi;
Song, JiangBo;
Song, LiMing;
Sgro, Carmelo;
Sun, Liang;
Tan, Ying;
Uttley, Phil;
Wang, Juan;
Wang, LangPing;
Wang, YuSa;
Watts, Anna L.;
Wen, XiangYang;
Wilms, Jörn;
Xiong, ShaoLin;
Yang, JiaWei;
Yang, Sheng;
Yang, YanJi;
Yu, Nian;
Zhang, WenDa;
Zampa, Gianluigi;
Zampa, Nicola;
Zdziarski, Andrzej A.;
Zhang, AiMei;
Zhang, ChengMo;
Zhang, Fan;
Zhang, Long;
Zhang, Tong;
Zhang, Yi;
Zhang, XiaoLi;
Zhang, ZiLiang;
Zhao, BaoSheng;
Zheng, ShiJie;
Zhou, YuPeng;
Zorzi, Nicola;
Zwart, J. Frans
Submitted: 2018-12-10
In this paper we present the enhanced X-ray Timing and Polarimetry mission -
eXTP. eXTP is a space science mission designed to study fundamental physics
under extreme conditions of density, gravity and magnetism. The mission aims at
determining the equation of state of matter at supra-nuclear density, measuring
effects of QED, and understanding the dynamics of matter in strong-field
gravity. In addition to investigating fundamental physics, eXTP will be a very
powerful observatory for astrophysics that will provide observations of
unprecedented quality on a variety of galactic and extragalactic objects. In
particular, its wide field monitoring capabilities will be highly instrumental
to detect the electro-magnetic counterparts of gravitational wave sources. The
paper provides a detailed description of: (1) the technological and technical
aspects, and the expected performance of the instruments of the scientific
payload; (2) the elements and functions of the mission, from the spacecraft to
the ground segment.
[4]
oai:arXiv.org:1607.08823 [pdf] - 2064188
eXTP -- enhanced X-ray Timing and Polarimetry Mission
Zhang, S. N.;
Feroci, M.;
Santangelo, A.;
Dong, Y. W.;
Feng, H.;
Lu, F. J.;
Nandra, K.;
Wang, Z. S.;
Zhang, S.;
Bozzo, E.;
Brandt, S.;
De Rosa, A.;
Gou, L. J.;
Hernanz, M.;
van der Klis, M.;
Li, X. D.;
Liu, Y.;
Orleanski, P.;
Pareschi, G.;
Pohl, M.;
Poutanen, J.;
Qu, J. L.;
Schanne, S.;
Stella, L.;
Uttley, P.;
Watts, A.;
Xu, R. X.;
Yu, W. F.;
Zand, J. J. M. in 't;
Zane, S.;
Alvarez, L.;
Amati, L.;
Baldini, L.;
Bambi, C.;
Basso, S.;
Bhattacharyya, S.;
Bellazzini, R.;
Belloni, T.;
Bellutti, P.;
Bianchi, S.;
Brez, A.;
Bursa, M.;
Burwitz, V.;
Budtz-Jorgensen, C.;
Caiazzo, I.;
Campana, R.;
Cao, X. L.;
Casella, P.;
Chen, C. Y.;
Chen, L.;
Chen, T. X.;
Chen, Y.;
Chen, Y.;
Chen, Y. P.;
Civitani, M.;
Zelati, F. Coti;
Cui, W.;
Cui, W. W.;
Dai, Z. G.;
Del Monte, E.;
De Martino, D.;
Di Cosimo, S.;
Diebold, S.;
Dovciak, M.;
Donnarumma, I.;
Doroshenko, V.;
Esposito, P.;
Evangelista, Y.;
Favre, Y.;
Friedrich, P.;
Fuschino, F.;
Galvez, J. L.;
Gao, Z. L.;
Ge, M. Y.;
Gevin, O.;
Goetz, D.;
Han, D. W.;
Heyl, J.;
Horak, J.;
Hu, W.;
Huang, F.;
Huang, Q. S.;
Hudec, R.;
Huppenkothen, D.;
Israel, G. L.;
Ingram, A.;
Karas, V.;
Karelin, D.;
Jenke, P. A.;
Ji, L.;
Kennedy, T.;
Korpela, S.;
Kunneriath, D.;
Labanti, C.;
Li, G.;
Li, X.;
Li, Z. S.;
Liang, E. W.;
Limousin, O.;
Lin, L.;
Ling, Z. X.;
Liu, H. B.;
Liu, H. W.;
Liu, Z.;
Lu, B.;
Lund, N.;
Lai, D.;
Luo, B.;
Luo, T.;
Ma, B.;
Mahmoodifar, S.;
Marisaldi, M.;
Martindale, A.;
Meidinger, N.;
Men, Y. P.;
Michalska, M.;
Mignani, R.;
Minuti, M.;
Motta, S.;
Muleri, F.;
Neilsen, J.;
Orlandini, M.;
Pan, A T.;
Patruno, A.;
Perinati, E.;
Picciotto, A.;
Piemonte, C.;
Pinchera, M.;
Rachevski, A.;
Rapisarda, M.;
Rea, N.;
Rossi, E. M. R.;
Rubini, A.;
Sala, G.;
Shu, X. W.;
Sgro, C.;
Shen, Z. X.;
Soffitta, P.;
Song, L. M.;
Spandre, G.;
Stratta, G.;
Strohmayer, T. E.;
Sun, L.;
Svoboda, J.;
Tagliaferri, G.;
Tenzer, C.;
Tong, H.;
Taverna, R.;
Torok, G.;
Turolla, R.;
Vacchi, A.;
Wang, J.;
Wang, J. X.;
Walton, D.;
Wang, K.;
Wang, J. F.;
Wang, R. J.;
Wang, Y. F.;
Weng, S. S.;
Wilms, J.;
Winter, B.;
Wu, X.;
Wu, X. F.;
Xiong, S. L.;
Xu, Y. P.;
Xue, Y. Q.;
Yan, Z.;
Yang, S.;
Yang, X.;
Yang, Y. J.;
Yuan, F.;
Yuan, W. M.;
Yuan, Y. F.;
Zampa, G.;
Zampa, N.;
Zdziarski, A.;
Zhang, C.;
Zhang, C. L.;
Zhang, L.;
Zhang, X.;
Zhang, Z.;
Zhang, W. D.;
Zheng, S. J.;
Zhou, P.;
Zhou, X. L.
Submitted: 2016-07-29
eXTP is a science mission designed to study the state of matter under extreme
conditions of density, gravity and magnetism. Primary targets include isolated
and binary neutron stars, strong magnetic field systems like magnetars, and
stellar-mass and supermassive black holes. The mission carries a unique and
unprecedented suite of state-of-the-art scientific instruments enabling for the
first time ever the simultaneous spectral-timing-polarimetry studies of cosmic
sources in the energy range from 0.5-30 keV (and beyond). Key elements of the
payload are: the Spectroscopic Focusing Array (SFA) - a set of 11 X-ray optics
for a total effective area of about 0.9 m^2 and 0.6 m^2 at 2 keV and 6 keV
respectively, equipped with Silicon Drift Detectors offering <180 eV spectral
resolution; the Large Area Detector (LAD) - a deployable set of 640 Silicon
Drift Detectors, for a total effective area of about 3.4 m^2, between 6 and 10
keV, and spectral resolution <250 eV; the Polarimetry Focusing Array (PFA) - a
set of 2 X-ray telescope, for a total effective area of 250 cm^2 at 2 keV,
equipped with imaging gas pixel photoelectric polarimeters; the Wide Field
Monitor (WFM) - a set of 3 coded mask wide field units, equipped with
position-sensitive Silicon Drift Detectors, each covering a 90 degrees x 90
degrees FoV. The eXTP international consortium includes mostly major
institutions of the Chinese Academy of Sciences and Universities in China, as
well as major institutions in several European countries and the United States.
The predecessor of eXTP, the XTP mission concept, has been selected and funded
as one of the so-called background missions in the Strategic Priority Space
Science Program of the Chinese Academy of Sciences since 2011. The strong
European participation has significantly enhanced the scientific capabilities
of eXTP. The planned launch date of the mission is earlier than 2025.
[5]
oai:arXiv.org:1509.05595 [pdf] - 1323479
Assembly and Test of the Gas Pixel Detector for X-ray Polarimetry
Li, H.;
Feng, H.;
Muleri, F.;
Bellazzini, R.;
Minuti, M.;
Soffitta, P.;
Brez, A.;
Spandre, G.;
Pinchera, M.;
Sgro, C.;
Baldini, L.;
She, R.;
Costa, E.
Submitted: 2015-09-18
The gas pixel detector (GPD) dedicated for photoelectric X-ray polarimetry is
selected as the focal plane detector for the ESA medium-class mission concept
X-ray Imaging and Polarimetry Explorer (XIPE). Here we show the design,
assembly, and preliminary test results of a small GPD for the purpose of gas
mixture optimization needed for the phase A study of XIPE. The detector is
assembled in house at Tsinghua University following a design by the INFN-Pisa
group. The improved detector design results in a good uniformity for the
electric field. Filled with pure dimethyl ether (DME) at 0.8 atm, the measured
energy resolution is 18% at 6 keV and inversely scales with the square root of
the X-ray energy. The measured modulation factor is well consistent with that
from simulation, up to ~0.6 above 6 keV. The residual modulation is found to be
0.30% +/- 0.15% at 6 keV for the whole sensitive area, which can be translated
into a systematic error of less than 1% for polarization measurement at a
confidence level of 99%. The position resolution of the detector is about 80 um
in FWHM, consistent with previous studies and sufficient for XIPE requirements.
[6]
oai:arXiv.org:1509.04392 [pdf] - 1277254
LAMP: a micro-satellite based soft X-ray polarimeter for astrophysics
She, Rui;
Feng, Hua;
Muleri, Fabio;
Soffitta, Paolo;
Xu, Renxin;
Li, Hong;
Bellazzini, Ronaldo;
Wang, Zhanshan;
Spiga, Daniele;
Minuti, Massimo;
Brez, Alessandro;
Spandre, Gloria;
Pinchera, Michele;
Sgro, Carmelo;
Baldini, Luca;
Wen, Mingwu;
Shen, Zhengxiang;
Pareschi, Giovanni;
Tagliaferri, Gianpiero;
Tayabaly, Kashmira;
Salmaso, Bianca;
Zhan, Yafeng
Submitted: 2015-09-15
The Lightweight Asymmetry and Magnetism Probe (LAMP) is a micro-satellite
mission concept dedicated for astronomical X-ray polarimetry and is currently
under early phase study. It consists of segmented paraboloidal multilayer
mirrors with a collecting area of about 1300 cm^2 to reflect and focus 250 eV
X-rays, which will be detected by position sensitive detectors at the focal
plane. The primary targets of LAMP include the thermal emission from the
surface of pulsars and synchrotron emission produced by relativistic jets in
blazars. With the expected sensitivity, it will allow us to detect polarization
or place a tight upper limit for about 10 pulsars and 20 blazars. In addition
to measuring magnetic structures in these objects, LAMP will also enable us to
discover bare quark stars if they exist, whose thermal emission is expected to
be zero polarized, while the thermal emission from neutron stars is believed to
be highly polarized due to plasma polarization and the quantum electrodynamics
(QED) effect. Here we present an overview of the mission concept, its science
objectives and simulated observational results.
[8]
oai:arXiv.org:1509.01979 [pdf] - 1272465
INFN Camera demonstrator for the Cherenkov Telescope Array
Ambrosi, G.;
Ambrosio, M.;
Aramo, C.;
Bertucci, B.;
Bissaldi, E.;
Bitossi, M.;
Brasolin, S.;
Busetto, G.;
Carosi, R.;
Catalanotti, S.;
Ciocci, M. A.;
Consoletti, R.;
Da Vela, P.;
Dazzi, F.;
De Angelis, A.;
De Lotto, B.;
de Palma, F.;
Desiante, R.;
Di Girolamo, T.;
Di Giulio, C.;
Doro, M.;
D'Urso, D.;
Ferraro, G.;
Ferrarotto, F.;
Gargano, F.;
Giglietto, N.;
Giordano, F.;
Giraudo, G.;
Iacovacci, M.;
Ionica, M.;
Iori, M.;
Longo, F.;
Mariotti, M.;
Mastroianni, S.;
Minuti, M.;
Morselli, A.;
Paoletti, R.;
Pauletta, G.;
Rando, R.;
Fernandez, G. Rodriguez;
Rugliancich, A.;
Simone, D.;
Stella, C.;
Tonachini, A.;
Vallania, P.;
Valore, L.;
Vagelli, V.;
Verzi, V.;
Vigorito, C.
Submitted: 2015-09-07
The Cherenkov Telescope Array is a world-wide project for a new generation of
ground-based Cherenkov telescopes of the Imaging class with the aim of
exploring the highest energy region of the electromagnetic spectrum. With two
planned arrays, one for each hemisphere, it will guarantee a good sky coverage
in the energy range from a few tens of GeV to hundreds of TeV, with improved
angular resolution and a sensitivity in the TeV energy region better by one
order of magnitude than the currently operating arrays. In order to cover this
wide energy range, three different telescope types are envisaged, with
different mirror sizes and focal plane features. In particular, for the highest
energies a possible design is a dual-mirror Schwarzschild-Couder optical
scheme, with a compact focal plane. A silicon photomultiplier (SiPM) based
camera is being proposed as a solution to match the dimensions of the pixel
(angular size of ~ 0.17 degrees). INFN is developing a camera demonstrator made
by 9 Photo Sensor Modules (PSMs, 64 pixels each, with total coverage 1/4 of the
focal plane) equipped with FBK (Fondazione Bruno Kessler, Italy) Near
UltraViolet High Fill factor SiPMs and Front-End Electronics (FEE) based on a
Target 7 ASIC, a 16 channels fast sampler (up to 2GS/s) with deep buffer,
self-trigger and on-demand digitization capabilities specifically developed for
this purpose. The pixel dimensions of $6\times6$ mm$^2$ lead to a very compact
design with challenging problems of thermal dissipation. A modular structure,
made by copper frames hosting one PSM and the corresponding FEE, has been
conceived, with a water cooling system to keep the required working
temperature. The actual design, the adopted technical solutions and the
achieved results for this demonstrator are presented and discussed.
[9]
oai:arXiv.org:1403.7200 [pdf] - 1208656
The imaging properties of the Gas Pixel Detector as a focal plane
polarimeter
Fabiani, S.;
Costa, E.;
Del Monte, E.;
Muleri, F.;
Soffitta, P.;
Rubini, A.;
Bellazzini, R.;
Brez, A.;
de Ruvo, L.;
Minuti, M.;
Pinchera, M.;
Sgrò, C.;
Spandre, G.;
Spiga, D.;
Tagliaferri, G.;
Pareschi, G.;
Basso, S.;
Citterio, O.;
Burwitz, V.;
Burkert, W.;
Menz, B.;
Hartner, G.
Submitted: 2014-03-27
X-rays are particularly suited to probe the physics of extreme objects.
However, despite the enormous improvements of X-ray Astronomy in imaging,
spectroscopy and timing, polarimetry remains largely unexplored. We propose the
photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate
to fill the gap of more than thirty years of lack of measurements. The GPD, in
the focus of a telescope, will increase the sensitivity of orders of magnitude.
Moreover, since it can measure the energy, the position, the arrival time and
the polarization angle of every single photon, allows to perform polarimetry of
subsets of data singled out from the spectrum, the light curve or the image of
source. The GPD has an intrinsic very fine imaging capability and in this work
we report on the calibration campaign carried out in 2012 at the PANTER X-ray
test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of
Garching (Germany) in which, for the first time, we coupled it to a JET-X
optics module with a focal length of 3.5 m and an angular resolution of 18
arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray
Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small
mission. We derived the imaging and polarimetric performance for extended
sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the
XIPE configuration, discussing also possible improvements by coupling the
detector with advanced optics, having finer angular resolution and larger
effective area, to study with more details extended objects.
[10]
oai:arXiv.org:1311.2220 [pdf] - 786443
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Spiga, Daniele;
Tagliaferri, Gianpiero;
Soffitta, Paolo;
Citterio, Oberto;
Basso, Stefano;
Bellazzini, Ronaldo;
Brez, Alessandro;
Burkert, Wolfgang;
Burwitz, Vadim;
Costa, Enrico;
de Ruvo, Luca;
Del Monte, Ettore;
Fabiani, Sergio;
Hartner, Gisela;
Menz, Benedikt;
Minuti, Massimo;
Muleri, Fabio;
Pareschi, Giovanni;
Pinchera, Michele;
Rubini, Alda;
Sgrò, Carmelo;
Spandre, Gloria
Submitted: 2013-11-09, last modified: 2014-02-18
The Joint European X-ray Telescope (JET-X) was the core instrument of the
Russian Spectrum-X-gamma space observatory. It consisted of two identical soft
X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured
angular resolution of nearly 15 arcsec. Soon after the payload completion, the
mission was cancelled and the two optical flight modules (FM) were brought to
the Brera Astronomical Observatory where they had been manufactured. After 16
years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray
facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel
Detector (GPD) with polarimetric capabilities in the focal plane of the FM2.
The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In
the first phase of the test campaign, we have re-tested the FM2 at PANTER to
have an up-to-date characterization in terms of angular resolution and
effective area, while in the second part of the test the GPD has been placed in
the focal plane of the FM2. In this paper we report the results of the tests of
the sole FM2, using an unpolarized X-ray source, comparing the results with the
calibration done in 1996.
[11]
oai:arXiv.org:1309.6995 [pdf] - 1453148
XIPE: the X-ray Imaging Polarimetry Explorer
Soffitta, Paolo;
Barcons, Xavier;
Bellazzini, Ronaldo;
Braga, João;
Costa, Enrico;
Fraser, George W.;
Gburek, Szymon;
Huovelin, Juhani;
Matt, Giorgio;
Pearce, Mark;
Poutanen, Juri;
Reglero, Victor;
Santangelo, Andrea;
Sunyaev, Rashid A.;
Tagliaferri, Gianpiero;
Weisskopf, Martin;
Aloisio, Roberto;
Amato, Elena;
Attiná, Primo;
Axelsson, Magnus;
Baldini, Luca;
Basso, Stefano;
Bianchi, Stefano;
Blasi, Pasquale;
Bregeon, Johan;
Brez, Alessandro;
Bucciantini, Niccoló;
Burderi, Luciano;
Burwitz, Vadim;
Casella, Piergiorgio;
Churazov, Eugene;
Civitani, Marta;
Covino, Stefano;
da Silva, Rui Miguel Curado;
Cusumano, Giancarlo;
Dadina, Mauro;
D'Amico, Flavio;
De Rosa, Alessandra;
Di Cosimo, Sergio;
Di Persio, Giuseppe;
Di Salvo, Tiziana;
Dovciak, Michal;
Elsner, Ronald;
Eyles, Chris J.;
Fabian, Andrew C.;
Fabiani, Sergio;
Feng, Hua;
Giarrusso, Salvatore;
Goosmann, René W.;
Grandi, Paola;
Grosso, Nicolas;
Israel, Gianluca;
Jackson, Miranda;
Kaaret, Philip;
Karas, Vladimir;
Kuss, Michael;
Lai, Dong;
La Rosa, Giovanni;
Larsson, Josefin;
Larsson, Stefan;
Latronico, Luca;
Maggio, Antonio;
Maia, Jorge;
Marin, Frédéric;
Massai, Marco Maria;
Mineo, Teresa;
Minuti, Massimo;
Moretti, Elena;
Muleri, Fabio;
O'Dell, Stephen L.;
Pareschi, Giovanni;
Peres, Giovanni;
Pesce, Melissa;
Petrucci, Pierre-Olivier;
Pinchera, Michele;
Porquet, Delphine;
Ramsey, Brian;
Rea, Nanda;
Reale, Fabio;
Rodrigo, Juana Maria;
Różańska, Agata;
Rubini, Alda;
Rudawy, Pawel;
Ryde, Felix;
Salvati, Marco;
Júnior, Valdivino Alexandre de Santiago;
Sazonov, Sergey;
Sgró, Carmelo;
Silver, Eric;
Spandre, Gloria;
Spiga, Daniele;
Stella, Luigi;
Tamagawa, Toru;
Tamborra, Francesco;
Tavecchio, Fabrizio;
Dias, Teresa Teixeira;
van Adelsberg, Matthew;
Wu, Kinwah;
Zane, Silvia
Submitted: 2013-09-26
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and
temporal variability measurements and to imaging, allows a wealth of physical
phenomena in astrophysics to be studied. X-ray polarimetry investigates the
acceleration process, for example, including those typical of magnetic
reconnection in solar flares, but also emission in the strong magnetic fields
of neutron stars and white dwarfs. It detects scattering in asymmetric
structures such as accretion disks and columns, and in the so-called molecular
torus and ionization cones. In addition, it allows fundamental physics in
regimes of gravity and of magnetic field intensity not accessible to
experiments on the Earth to be probed. Finally, models that describe
fundamental interactions (e.g. quantum gravity and the extension of the
Standard Model) can be tested. We describe in this paper the X-ray Imaging
Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a
small mission with a launch in 2017 but not selected. XIPE is composed of two
out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD)
filled with a He-DME mixture at their focus and two additional GPDs filled with
pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 %
at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half
Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X
optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with
Malindi as down-link station and of a Mission Operation Center (MOC) at INPE
(Brazil).
[13]
oai:arXiv.org:1208.6330 [pdf] - 1151008
Measurement of the position resolution of the Gas Pixel Detector
Submitted: 2012-08-30
The Gas Pixel Detector was designed and built as a focal plane instrument for
X-ray polarimetry of celestial sources, the last unexplored subtopics of X-ray
astronomy. It promises to perform detailed and sensitive measurements resolving
extended sources and detecting polarization in faint sources in crowded fields
at the focus of telescopes of good angular resolution. Its polarimetric and
spectral capability were already studied in earlier works. Here we investigate
for the first time, with both laboratory measurements and Monte Carlo
simulations, its imaging properties to confirm its unique capability to carry
out imaging spectral-polarimetry in future X-ray missions.
[14]
oai:arXiv.org:1105.0637 [pdf] - 353860
POLARIX: a pathfinder mission of X-ray polarimetry
Costa, Enrico;
Bellazzini, Ronaldo;
Tagliaferri, Gianpiero;
Matt, Giorgio;
Argan, Andrea;
Attina', Primo;
Baldini, Luca;
Basso, Stefano;
Brez, Alessandro;
Citterio, Oberto;
Di Cosimo, Sergio;
Cotroneo, Vincenzo;
Fabiani, Sergio;
Feroci, Marco;
Ferri, Antonella;
Latronico, Luca;
Lazzarotto, Francesco;
Minuti, Massimo;
Morelli, Ennio;
Muleri, Fabio;
Nicolini, Lucio;
Pareschi, Giovanni;
Di Persio, Giuseppe;
Pinchera, Michele;
Razzano, Massimiliano;
Reboa, Luigia;
Rubini, Alda;
Salonico, Antonio Maria;
Sgro', Carmelo;
Soffitta, Paolo;
Spandre, Gloria;
Spiga, Daniele;
Trois, Alessio
Submitted: 2011-05-03
Since the birth of X-ray astronomy, spectral, spatial and timing observation
improved dramatically, procuring a wealth of information on the majority of the
classes of the celestial sources. Polarimetry, instead, remained basically
unprobed. X-ray polarimetry promises to provide additional information
procuring two new observable quantities, the degree and the angle of
polarization. POLARIX is a mission dedicated to X-ray polarimetry. It exploits
the polarimetric response of a Gas Pixel Detector, combined with position
sensitivity, that, at the focus of a telescope, results in a huge increase of
sensitivity. Three Gas Pixel Detectors are coupled with three X-ray optics
which are the heritage of JET-X mission. POLARIX will measure time resolved
X-ray polarization with an angular resolution of about 20 arcsec in a field of
view of 15 arcmin $\times$ 15 arcmin and with an energy resolution of 20 % at 6
keV. The Minimum Detectable Polarization is 12 % for a source having a flux of
1 mCrab and 10^5 s of observing time. The satellite will be placed in an
equatorial orbit of 505 km of altitude by a Vega launcher.The telemetry
down-link station will be Malindi. The pointing of POLARIX satellite will be
gyroless and it will perform a double pointing during the earth occultation of
one source, so maximizing the scientific return. POLARIX data are for 75 % open
to the community while 25 % + SVP (Science Verification Phase, 1 month of
operation) is dedicated to a core program activity open to the contribution of
associated scientists. The planned duration of the mission is one year plus
three months of commissioning and SVP, suitable to perform most of the basic
science within the reach of this instrument.
[15]
oai:arXiv.org:1003.6009 [pdf] - 1026036
Spectral and polarimetric characterization of the Gas Pixel Detector
filled with dimethyl ether
Muleri, F.;
Soffitta, P.;
Baldini, L.;
Bellazzini, R.;
Brez, A.;
Costa, E.;
Fabiani, S.;
Krummenacher, F.;
Latronico, L.;
Lazzarotto, F.;
Minuti, M.;
Pinchera, M.;
Rubini, A.;
Sgro, C.;
Spandre, G.
Submitted: 2010-03-31
The Gas Pixel Detector belongs to the very limited class of gas detectors
optimized for the measurement of X-ray polarization in the emission of
astrophysical sources. The choice of the mixture in which X-ray photons are
absorbed and photoelectrons propagate, deeply affects both the energy range of
the instrument and its performance in terms of gain, track dimension and
ultimately, polarimetric sensitivity. Here we present the characterization of
the Gas Pixel Detector with a 1 cm thick cell filled with dimethyl ether (DME)
at 0.79 atm, selected among other mixtures for the very low diffusion
coefficient. Almost completely polarized and monochromatic photons were
produced at the calibration facility built at INAF/IASF-Rome exploiting Bragg
diffraction at nearly 45 degrees. For the first time ever, we measured the
modulation factor and the spectral capabilities of the instrument at energies
as low as 2.0 keV, but also at 2.6 keV, 3.7 keV, 4.0 keV, 5.2 keV and 7.8 keV.
These measurements cover almost completely the energy range of the instrument
and allows to compare the sensitivity achieved with that of the standard
mixture, composed of helium and DME.
[16]
oai:arXiv.org:0911.5698 [pdf] - 902584
X-ray polarimetry in Astrophysics with the Gas Pixel Detector
Muleri, F.;
Bellazzini, R.;
Brez, A.;
Costa, E.;
Lazzarotto, F.;
Minuti, M.;
Pinchera, M.;
Rubini, A.;
Soffitta, P.;
Spandre, G.
Submitted: 2009-11-30
The Gas Pixel Detector, recently developed and continuously improved by Pisa
INFN in collaboration with IASF-Roma of INAF, can visualize the tracks produced
within a low Z gas by photoelectrons of few keV. By reconstructing the impact
point and the original direction of the photoelectrons, the GPD can measure the
linear polarization of X-rays, while preserving the information on the
absorption point, the energy and the time of individual photons. Applied to
X-ray Astrophysics, in the focus of grazing incidence telescopes, it can
perform angular resolved polarimetry with a huge improvement of sensitivity,
when compared with the conventional techniques of Bragg diffraction at 45
degrees and Compton scattering around 90 degrees. This configuration is the
basis of POLARIX and HXMT, two pathfinder missions, and is included in the
baseline design of IXO, the very large X-ray telescope under study by NASA, ESA
and JAXA.
[17]
oai:arXiv.org:0810.2700 [pdf] - 17470
XPOL: a photoelectric polarimeter onboard XEUS
Costa, Enrico;
Bellazzini, Ronaldo;
Bregeon, Jean;
Brez, Alessandro;
Frutti, Massimo;
Di Cosimo, Sergio;
Latronicio, Luca;
Lazzarotto, Francesco;
Matt, Giorgio;
Minuti, Massimo;
Morelli, Ennio;
Muleri, Fabio;
Pinchera, Michele;
Razzano, Massimiliano;
Rubini, Alda;
Soffitta, Paolo;
Spandre, Gloria
Submitted: 2008-10-15
The XEUS mission incorporates two satellites: the Mirror Spacecraft with 5 m2
of collecting area at 1 keV and 2 m2 at 7 keV, and an imaging resolution of 5"
HEW and the Payload Spacecraft which carries the focal plane instrumentation.
XEUS was submitted to ESA Cosmic Vision and was selected for an advanced study
as a large mission. The baseline design includes XPOL, a polarimeter based on
the photoelectric effect, that takes advantage of the large effective area
which permits the study of the faint sources and of the long focal length,
resulting in a very good spatial resolution, which allows the study of spatial
features in extended sources. We show how, with XEUS, Polarimetry becomes an
efficient tool at disposition of the Astronomical community.
[18]
oai:arXiv.org:0810.2708 [pdf] - 17472
X-ray polarimetry on-board HXMT
Soffitta, Paolo;
Bellazzini, Ronaldo;
Tagliaferri, Gianpiero;
Costa, Enrico;
Pareschi, Giovanni;
Basso, Stefano;
Cotroneo, Vincenzo;
Frutti, Massimo;
Lazzarotto, Francesco;
Muleri, Fabio;
Rubini, Alda;
Spandre, Gloria;
Brez, Alessandro;
Baldini, Luca;
Bregeon, Jean;
Minuti, Massimo;
Matt, Giorgio;
Frontera, Filippo
Submitted: 2008-10-15
The development of micropixel gas detectors, capable to image tracks produced
in a gas by photoelectrons, makes possible to perform polarimetry of X-ray
celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a
mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with
Phoswich detectors, by exploitation of the direct demodulation technique. Since
a fraction of the HXMT time will be spent on dedicated pointing of particular
sources, it could host, with moderate additional resources a pair of X-ray
telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray
Photoelectric Polarimeter) in the focal plane. We present the design of the
telescopes and the focal plane instrumentation and discuss the performance of
this instrument to detect the degree and angle of linear polarization of some
representative sources. Notwithstanding the limited resources, the proposed
instrument can represent a breakthrough in X-ray Polarimetry.
[19]
oai:arXiv.org:0810.2693 [pdf] - 17468
The Gas Pixel Detector as an X-ray photoelectric polarimeter with a
large field of view
Muleri, Fabio;
Soffitta, Paolo;
Bellazzini, Ronaldo;
Brez, Alessandro;
Costa, Enrico;
Fabiani, Sergio;
Frutti, Massimo;
Minuti, Massimo;
Negri, Maria Barbara;
Pinchera, Michele;
Rubini, Alda;
Spandre, Gloria
Submitted: 2008-10-15
The Gas Pixel Detector (GPD) is a new generation device which, thanks to its
50 um pixels, is capable of imaging the photoelectrons tracks produced by
photoelectric absorption in a gas. Since the direction of emission of the
photoelectrons is strongly correlated with the direction of polarization of the
absorbed photons, this device has been proposed as a polarimeter for the study
of astrophysical sources, with a sensitivity far higher than the instruments
flown to date. The GPD has been always regarded as a focal plane instrument and
then it has been proposed to be included on the next generation space-borne
missions together with a grazing incidence optics. Instead in this paper we
explore the feasibility of a new kind of application of the GPD and of the
photoelectric polarimeters in general, i.e. an instrument with a large field of
view. By means of an analytical treatment and measurements, we verify if it is
possible to preserve the sensitivity to the polarization for inclined beams,
opening the way for the measurement of X-ray polarization for transient
astrophysical sources. While severe systematic effects arise for inclination
greater than about 20 degrees, methods and algorithms to control them are
discussed.
[20]
oai:arXiv.org:0709.4623 [pdf] - 5478
Low energy polarization sensitivity of the Gas Pixel Detector
Muleri, F.;
Soffitta, P.;
Baldini, L.;
Bellazzini, R.;
Bregeon, J.;
Brez, A.;
Costa, E.;
Frutti, M.;
Latronico, L.;
Minuti, M.;
Negri, M. B.;
Omodei, N.;
Pinchera, M.;
Pesce-Rollins, M.;
Razzano, M.;
Rubini, A.;
Sgro', C.;
Spandre, G.
Submitted: 2007-09-28
An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been
proposed to be included in many upcoming space missions to fill the gap of
about 30 years from the first (and to date only) positive measurement of
polarized X-ray emission from an astrophysical source. The estimated
sensitivity of the current prototype peaks at an energy of about 3 keV, but the
lack of readily available polarized sources in this energy range has prevented
the measurement of detector polarimetric performances.
In this paper we present the measurement of the Gas Pixel Detector
polarimetric sensitivity at energies of a few keV and the new, light, compact
and transportable polarized source that was devised and built to this aim.
Polarized photons are produced, from unpolarized radiation generated with an
X-ray tube, by means of Bragg diffraction at nearly 45 degrees.
The employment of mosaic graphite and flat aluminum crystals allow the
production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from
the diffraction of unpolarized continuum or line emission. The measured
modulation factor of the Gas Pixel Detector at these energies is in good
agreement with the estimates derived from a Monte Carlo software, which was up
to now employed for driving the development of the instrument and for
estimating its low energy sensitivity. In this paper we present the excellent
polarimetric performance of the Gas Pixel Detector at energies where the peak
sensitivity is expected. These measurements not only support our previous
claims of high sensitivity but confirm the feasibility of astrophysical X-ray
photoelectric polarimetry.
[21]
oai:arXiv.org:0709.3992 [pdf] - 5336
An X-ray Polarimeter for HXMT Mission
Costa, Enrico;
Bellazzini, Ronaldo;
Tagliaferri, Gianpiero;
Baldini, Luca;
Basso, Stefano;
Bregeon, Johan;
Brez, Alessandro;
Citterio, Oberto;
Cotroneo, Vincenzo;
Frontera, Filippo;
Frutti, Massimo;
Matt, Giorgio;
Minuti, Massimo;
Muleri, Fabio;
Pareschi, Giovanni;
Perola, Giuseppe Cesare;
Rubini, Alda;
Sgro', Carmelo;
Soffitta, Paolo;
Spandre, Gloria
Submitted: 2007-09-25
The development of micropixel gas detectors, capable to image tracks produced
in a gas by photoelectrons, makes possible to perform polarimetry of X-ray
celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a
mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with
Phoswich detectors, by exploitation of the direct demodulation technique. Since
a fraction of the HXMT time will be spent on dedicated pointing of particular
sources, it could host, with moderate additional resources a pair of X-ray
telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We
present the design of the telescopes and the focal plane instrumentation and
discuss the performance of this instrument to detect the degree and angle of
linear polarization of some representative sources. Notwithstanding the limited
resources the proposed instrument can represent a breakthrough in X-ray
Polarimetry.
[22]
oai:arXiv.org:0709.3978 [pdf] - 5330
A very compact polarizer for an X-ray polarimeter calibration
Muleri, Fabio;
Soffitta, Paolo;
Bellazzini, Ronaldo;
Brez, Alessandro;
Costa, Enrico;
Fabiani, Sergio;
Frutti, Massimo;
Minuti, Massimo;
Negri, Maria Barbara;
Pascale, Piermarco;
Rubini, Alda;
Sindoni, Giuseppe;
Spandre, Gloria
Submitted: 2007-09-25
We devised and built a light, compact and transportable X-ray polarized
source based on the Bragg diffraction at nearly 45 degrees. The source is
composed by a crystal coupled to a small power X-ray tube. The angles of
incidence are selected by means of two orthogonal capillary plates which, due
to the small diameter holes (10 um) allow good collimation with limited sizes.
All the orders of diffraction defined by the crystal lattice spacing are
polarized up to the maximum order limited by the X-ray tube voltage. Selecting
suitably the crystal and the X-ray tube, either the line or the continuum
emission can be diffracted, producing polarized photons at different energies.
A very high degree of polarization and reasonable fluxes can be reached with a
suitable choice of the capillary plates collimation.
We present the source and test its performances with the production of nearly
completely polarized radiation at 2.6, 5.2, 3.7 and 7.4 keV thanks to the
employment of graphite and aluminum crystals, with copper and calcium X-ray
tubes respectively. Triggered by the very compact design of the source, we also
present a feasibility study for an on-board polarized source, coupled to a
radioactive Fe55 nuclide and a PVC thin film, for the calibration of the next
generation space-borne X-ray polarimeters at 2.6 and 5.9 keV.
[23]
oai:arXiv.org:physics/0703176 [pdf] - 119212
Imaging with the invisible light
Bellazzini, R.;
Spandre, G.;
Brez, A.;
Minuti, M.;
Baldini, L.;
Latronico, L.;
Massai, M. M.;
Omodei, N.;
Pesce-Rollins, M.;
Sgró, C;
Razzano, M.;
Pinchera, M.;
Bregeon, J.;
Kuss, M.;
Braem, A.
Submitted: 2007-03-19, last modified: 2007-03-20
We describe a UV photo-detector with single photon(electron) counting and
imaging capability. It is based on a CsI photocathode, a GEM charge multiplier
and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron
pitch. The single photoelectron produced by the absorption of a UV photon is
drifted to and multiplied inside a single GEM hole. The coordinates of the GEM
avalanche are reconstructed with high accuracy (4 micron rms) by the pixel
chip. As a result the map of the GEM holes, arranged on a triangular pattern at
50micron pitch, is finely imaged.
[24]
oai:arXiv.org:astro-ph/0611512 [pdf] - 86898
A Sealed Gas Pixel Detector for X-ray Astronomy
Bellazzini, R.;
Spandre, G.;
Minuti, M.;
Baldini, L.;
Brez, A.;
Latronico, L.;
Omodei, N.;
Razzano, M.;
Massai, M. M.;
Pinchera, M.;
Pesce-Rollins, M.;
Sgro, C.;
Costa, E.;
Soffitta, P.;
Sipila, H.;
Lempinen, E.
Submitted: 2006-11-16, last modified: 2006-11-20
We report on the results of a new, sealed, Gas Pixel Detector. The very
compact design and the absence of the gas flow system, make this detector
substantially ready for use as focal plane detector for future X-ray space
telescopes. The instrument brings high sensitivity to X-ray polarimetry, which
is the last unexplored field of X-ray astronomy. It derives the polarization
information from the track of the photoelectrons that are imaged by a high gain
(>1000), fine pitch GEM that matches the pitch of a pixel ASIC which is the
collecting anode of the GPD (105k, 50 micron wide, hexagonal cells). The device
is able to simultaneously perform good imaging (50-60 micron), moderate
spectroscopy (~15% at 6 keV) as well as fast, high rate timing in the 1-10keV
range. Moreover, being truly 2D, it is non dispersive and does not require any
rotation. The great improvement of sensitivity, at least two orders of
magnitude with respect to traditional polarimeters (based on Bragg crystals or
Thomson scattering), will allow the direct exploration of the most dramatic
objects of the X-ray sky. At the focus of the large mirror area of the XEUS
telescope it will be decisive in reaching many of the scientific goals of the
mission. With integration times of the order of one day, polarimetry of Active
Galactic Nuclei at the per cent level will be possible, making for a real
breakthrough in high energy astrophysics.
[25]
oai:arXiv.org:physics/0604114 [pdf] - 119160
Direct reading of charge multipliers with a self-triggering CMOS analog
chip with 105k pixels at 50 micron pitch
Bellazzini, R.;
Spandre, G.;
Minuti, M.;
Baldini, L.;
Brez, A.;
Cavalca, F.;
Latronico, L.;
Omodei, N.;
Massai, M. M.;
Sgro, C.;
Costa, E.;
Krummenacher, P. Soffitta F.;
DeOliveira, R.
Submitted: 2006-04-14, last modified: 2006-04-26
We report on a large active area (15x15mm2), high channel density (470
pixels/mm2), self-triggering CMOS analog chip that we have developed as
pixelized charge collecting electrode of a Micropattern Gas Detector. This
device, which represents a big step forward both in terms of size and
performance, is the last version of three generations of custom ASICs of
increasing complexity. The CMOS pixel array has the top metal layer patterned
in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is
directly connected to the underneath full electronics chain which has been
realized in the remaining five metal and two poly-silicon layers of a 0.18
micron VLSI technology. The chip has customizable self-triggering capability
and includes a signal pre-processing function for the automatic localization of
the event coordinates. In this way it is possible to reduce significantly the
readout time and the data volume by limiting the signal output only to those
pixels belonging to the region of interest. The very small pixel area and the
use of a deep sub-micron CMOS technology has brought the noise down to 50
electrons ENC. Results from in depth tests of this device when coupled to a
fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are
presented. The matching of readout and gas amplification pitch allows to get
optimal results. The application of this detector for Astronomical X-Ray
Polarimetry is discussed. The experimental detector response to polarized and
unpolarized X-ray radiation when working with two gas mixtures and two
different photon energies is shown. Results from a full MonteCarlo simulation
for several galactic and extragalactic atronomical sources are also reported.
[26]
oai:arXiv.org:astro-ph/0512242 [pdf] - 78442
Gas Pixel Detectors for X-ray Polarimetry applications
Bellazzini, R.;
Angelini, F.;
Baldini, L.;
Bitti, F.;
Brez, A.;
Cavalca, F.;
Del Prete, M.;
Kuss, M.;
Latronico, L.;
Omodei, N.;
Pinchera, M.;
Massai, M. M.;
Minuti, M.;
Razzano, M.;
Sgro, C.;
Spandre, G.;
Tenze, A.;
Costa, E.;
Soffitta, P.
Submitted: 2005-12-09, last modified: 2006-02-08
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector
(GPD), in which a complete integration between the gas amplification structure
and the read-out electronics has been reached. An Application-Specific
Integrated Circuit (ASIC) built in deep sub-micron technology has been
developed to realize a monolithic device that is, at the same time, the
pixelized charge collecting electrode and the amplifying, shaping and charge
measuring front-end electronics. The CMOS chip has the top metal layer
patterned in a matrix of 80 micron pitch hexagonal pixels, each of them
directly connected to the underneath electronics chain which has been realized
in the remaining five layers of the 0.35 micron VLSI technology. Results from
tests of a first prototype of such detector with 2k pixels and a full scale
version with 22k pixels are presented. The application of this device for
Astronomical X-Ray Polarimetry is discussed. The experimental detector response
to polarized and unpolarized X-ray radiation is shown. Results from a full
MonteCarlo simulation for two astronomical sources, the Crab Nebula and the
Hercules X1, are also reported.
[27]
oai:arXiv.org:physics/0403019 [pdf] - 1238072
Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting
anode
Bellazzini, R.;
Angelini, F.;
Baldini, L.;
Bitti, F.;
Brez, A.;
Latronico, L.;
Massai, M. M.;
Minuti, M.;
Omodei, N.;
Razzano, M.;
Sgro, C.;
Spandre, G.;
Costa, E.;
Soffitta, P.
Submitted: 2004-03-01
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron
and the number of pixels is large (above 1000) it is virtually impossible to
use the conventional PCB read-out approach to bring the signal charge from the
individual pixel to the external electronics chain. For this reason a custom
CMOS array of 2101 active pixels with 80 micron pitch, directly used as the
charge collecting anode of a GEM amplifying structure, has been developed and
built. Each charge collecting pad, hexagonally shaped, realized using the top
metal layer of a deep submicron VLSI technology is individually connected to a
full electronics chain (pre-amplifier, shaping-amplifier, sample and hold,
multiplexer) which is built immediately below it by using the remaining five
active layers. The GEM and the drift electrode window are assembled directly
over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern
Gas Detector. With this approach, for the first time, gas detectors have
reached the level of integration and resolution typical of solid state pixel
detectors. Results from the first tests of this new read-out concept are
presented. An Astronomical X-Ray Polarimetry application is also discussed.