Normalized to: Miniussi, A.
[1]
oai:arXiv.org:2003.11899 [pdf] - 2070581
Progress in the development of frequency domain multiplexing for the
X-ray Integral Field Unit on board the Athena mission
Akamatsu, H.;
Gottardi, L.;
van der Kuur, J.;
de Vries, C. P.;
Bruijn, M. P.;
Chervenak, J. A.;
Kiviranta, M.;
Linden, A. J. van den;
Jackson, B. D.;
Miniussi, A.;
Ravensberg, K.;
Sakai, K.;
Smith, S. J.;
Wakeham, N.
Submitted: 2020-03-26
Frequency domain multiplexing (FDM) is the baseline readout system for the
X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM
scheme, TESs are coupled to a passive LC filter and biased with alternating
current (AC bias) at MHz frequencies. Using high-quality factor LC filters and
room temperature electronics developed at SRON and low-noise two-stage SQUID
amplifiers provided by VTT, we have recently demonstrated good performance with
the FDM readout of Mo/Au TES calorimeters with Au/Bi absorbers. We have
achieved a performance requested for the demonstration model (DM) with the
single pixel AC bias ($\Delta E=$1.8 eV) and 9 pixel multiplexing ($\Delta
E=$2.6 eV) modes. We have also demonstrated 14-pixel multiplexing with an
average energy resolution of 3.3 eV, which is limited by non-fundamental issues
related to FDM readout in our lab setup.
[2]
oai:arXiv.org:1908.02687 [pdf] - 2050188
Towards 100,000-pixel microcalorimeter arrays using multi-absorber
transition-edge sensors
Smith, S. J.;
Adams, J. S.;
Bandler, S. R.;
Beaumont, S.;
Chervenak, J. A.;
Datesman, A. M.;
Finkbeiner, F. M.;
Hummatov, R.;
Kelly, R. L.;
Kilbourne, C. A.;
Miniussi, A. R.;
Porter, F. S.;
Sadleir, J. E.;
Sakai, K.;
Wakeham, N. A.;
Wassell, E. J.;
Witthoeft, M. C.;
Ryu, K.
Submitted: 2019-08-07
We report on the development of multi-absorber transition edge sensors
(TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers
each with a different thermal conductance to a TES. Position information is
encoded in the pulse shape. With some trade-off in performance, hydras enable
very large format arrays without the prohibitive increase in bias and read-out
components associated with arrays of individual TESs. Hydras are under
development for the next generation of space telescope such as Lynx. Lynx is a
NASA concept under study that will combine a < 1 arcsecond angular resolution
optic with 100,000-pixel microcalorimeter array with energy resolution of
deltaE_FWHM ~ 3 eV in the soft x-ray energy range. We present first results
from hydras with 25-pixels for Lynx. Designs with absorbers on a 25 micron and
50 micron pitch are studied. Arrays incorporate, for the first time, microstrip
buried wiring layers of suitable pitch and density required to readout a
full-scale Lynx array. The resolution from the coadded energy histogram
including all 25-pixels was deltaE_FWHM = 1.66+/-0.02 eV and 3.34+/-0.06 eV at
an energy of 1.5 keV for the 25 micron and 50 micron absorber designs
respectively. Position discrimination is demonstrated from parameterization of
the rise-time.
[3]
oai:arXiv.org:1403.6592 [pdf] - 873816
Impact of particles on the Planck HFI detectors: Ground-based
measurements and physical interpretation
Catalano, A.;
Ade, P.;
Atik, Y.;
Benoit, A.;
Bréele, E.;
Bock, J. J.;
Camus, P.;
Chabot, M.;
Charra, M.;
Crill, B. P.;
Coron, N.;
Coulais, A.;
Désert, F. -X.;
Fauvet, L.;
Giraud-Héraud, Y.;
Guillaudin, O.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Macías-Pérez, J.;
Martinez, M.;
Miniussi, A.;
Monfardini, A.;
Pajot, F.;
Patanchon, G.;
Pelissier, A.;
Piat, M.;
Puget, J. -L.;
Renault, C.;
Rosset, C.;
Santos, D.;
Sauvé, A.;
Spencer, L. D.;
Sudiwala, R.
Submitted: 2014-03-26, last modified: 2014-09-02
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from
August 2009 to January 2012. Its noise and sensitivity performance were
excellent, but the rate of cosmic ray impacts on the HFI detectors was
unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane
produced transient signals in the data (glitches) with a wide range of
characteristics. A study of cosmic ray impacts on the HFI detector modules has
been undertaken to categorize and characterize the glitches, to correct the HFI
time-ordered data, and understand the residual effects on Planck maps and data
products. This paper presents an evaluation of the physical origins of glitches
observed by the HFI detectors. In order to better understand the glitches
observed by HFI in flight, several ground-based experiments were conducted with
flight-spare HFI bolometer modules. The experiments were conducted between 2010
and 2013 with HFI test bolometers in different configurations using varying
particles and impact energies. The bolometer modules were exposed to 23 MeV
protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm
$\alpha$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data
from the HFI ground-based preflight tests were used to further characterize the
glitches and compare glitch rates with statistical expectations under
laboratory conditions. Test results provide strong evidence that the dominant
family of glitches observed in flight are due to cosmic ray absorption by the
silicon die substrate on which the HFI detectors reside. Glitch energy is
propagated to the thermistor by ballistic phonons, while there is also a
thermal diffusion contribution. The implications of these results for future
satellite missions, especially those in the far-infrared to sub-millimetre and
millimetre regions of the electromagnetic spectrum, are discussed.
[4]
oai:arXiv.org:1404.1305 [pdf] - 811019
Study of Cosmic Ray Impact on Planck/HFI Low Temperature Detectors
Submitted: 2014-04-04, last modified: 2014-04-16
After the focal plane of the HFI instrument of the Planck mission (launched
in May 2009) reached its operational temperature, we observed thermal
signatures of interactions of cosmic rays with the Planck satellite, located at
the L2 Lagrange point. When a particle hits a component of the bolometers (e.g.
thermometer, grid or wafer) mounted on the focal plane of HFI, a thermal spike
(called glitch) due to energy deposition is measured. Processing these data
revealed another effect due to particle showers of high energy cosmic rays:
High Coincidence Events (HCE), composed of glitches occurring coincidentally in
many detectors followed by a temperature increase from the nK to the uK. A flux
of about 100 HCE per hour has been estimated. Two types of HCE have been
detected: fast and slow. For the first type, the untouched bolometers reached,
within a few seconds, the same temperature as those which were "touched". This
can be explained by the storage of the energy deposited in the stainless steel
focal plane. The second type of HCE is not fully understood yet. These effects
might be explained by an extra conduction due to the helium released by
cryogenic surfaces and creating a temporary thermal link between the different
stages of the HFI.
[5]
oai:arXiv.org:1403.5639 [pdf] - 800803
Characterization and Physical Explanation of Energetic Particles on
Planck HFI Instrument
Catalano, A.;
Ade, P.;
Atik, Y.;
Benoit, A.;
Bréele, E.;
Bock, J. J.;
Camus, P.;
Charra, M.;
Crill, B. P.;
Coron, N.;
Coulais, A.;
Désert, F. -X.;
Fauvet, L.;
Giraud-Héraud, Y.;
Guillaudin, O.;
Holmes, W.;
Jones, W. C.;
Lamarre, J. -M.;
Macías-Pérez, J.;
Martinez, M.;
Miniussi, A.;
Monfardini, A.;
Pajot, F.;
Patanchon, G.;
Pelissier, A.;
Piat, M.;
Puget, J. -L.;
Renault, C.;
Rosset, C.;
Santos, D.;
Sauvé, A.;
Spencer, L.;
Sudiwala, R.
Submitted: 2014-03-22
The Planck High Frequency Instrument (HFI) has been surveying the sky
continuously from the second Lagrangian point (L2) between August 2009 and
January 2012. It operates with 52 high impedance bolometers cooled at 100mK in
a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but
strong coupling with cosmic radiation. At L2, the particle flux is about 5
$cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft.
Protons with an energy above 40MeV can penetrate the focal plane unit box
causing two different effects: glitches in the raw data from direct interaction
of cosmic rays with detectors (producing a data loss of about 15% at the end of
the mission) and thermal drifts in the bolometer plate at 100mK adding
non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made
strong efforts in order to correct for this effect on the time ordered data and
final Planck maps. This work intends to give a view of the physical explanation
of the glitches observed in the HFI instrument in-flight. To reach this goal,
we performed several ground-based experiments using protons and $\alpha$
particles to test the impact of particles on the HFI spare bolometers with a
better control of the environmental conditions with respect to the in-flight
data. We have shown that the dominant part of glitches observed in the data
comes from the impact of cosmic rays in the silicon die frame supporting the
micro-machinced bolometric detectors propagating energy mainly by ballistic
phonons and by thermal diffusion. The implications of these results for future
satellite missions will be discussed.
[6]
oai:arXiv.org:1303.5071 [pdf] - 1165430
Planck 2013 results X. Energetic particle effects: characterization,
removal, and simulation
Planck Collaboration;
Ade, P. A. R.;
Aghanim, N.;
Armitage-Caplan, C.;
Arnaud, M.;
Ashdown, M.;
Atrio-Barandela, F.;
Aumont, J.;
Baccigalupi, C.;
Banday, A. J.;
Barreiro, R. B.;
Battaner, E.;
Benabed, K.;
Benoît, A.;
Benoit-Lévy, A.;
Bernard, J. -P.;
Bersanelli, M.;
Bielewicz, P.;
Bobin, J.;
Bock, J. J.;
Bond, J. R.;
Borrill, J.;
Bouchet, F. R.;
Bridges, M.;
Bucher, M.;
Burigana, C.;
Cardoso, J. -F.;
Catalano, A.;
Challinor, A.;
Chamballu, A.;
Chiang, L. -Y;
Chiang, H. C.;
Christensen, P. R.;
Church, S.;
Clements, D. L.;
Colombi, S.;
Colombo, L. P. L.;
Couchot, F.;
Coulais, A.;
Crill, B. P.;
Curto, A.;
Cuttaia, F.;
Danese, L.;
Davies, R. D.;
de Bernardis, P.;
de Rosa, A.;
de Zotti, G.;
Delabrouille, J.;
Delouis, J. -M.;
Désert, F. -X.;
Diego, J. M.;
Dole, H.;
Donzelli, S.;
Doré, O.;
Douspis, M.;
Dupac, X.;
Efstathiou, G.;
Enßlin, T. A.;
Eriksen, H. K.;
Finelli, F.;
Forni, O.;
Frailis, M.;
Franceschi, E.;
Galeotta, S.;
Ganga, K.;
Giard, M.;
Girard, D.;
Giraud-Héraud, Y.;
González-Nuevo, J.;
Górski, K. M.;
Gratton, S.;
Gregorio, A.;
Gruppuso, A.;
Hansen, F. K.;
Hanson, D.;
Harrison, D.;
Henrot-Versillé, S.;
Hernández-Monteagudo, C.;
Herranz, D.;
Hildebrandt, S. R.;
Hivon, E.;
Hobson, M.;
Holmes, W. A.;
Hornstrup, A.;
Hovest, W.;
Huffenberger, K. M.;
Jaffe, T. R.;
Jaffe, A. H.;
Jones, W. C.;
Juvela, M.;
Keihänen, E.;
Keskitalo, R.;
Kisner, T. S.;
Kneissl, R.;
Knoche, J.;
Knox, L.;
Kunz, M.;
Kurki-Suonio, H.;
Lagache, G.;
Lamarre, J. -M.;
Lasenby, A.;
Laureijs, R. J.;
Lawrence, C. R.;
Leonardi, R.;
Leroy, C.;
Lesgourgues, J.;
Liguori, M.;
Lilje, P. B.;
Linden-Vørnle, M.;
López-Caniego, M.;
Lubin, P. M.;
Macías-Pérez, J. F.;
Mandolesi, N.;
Maris, M.;
Marshall, D. J.;
Martin, P. G.;
Martínez-González, E.;
Masi, S.;
Matarrese, S.;
Matthai, F.;
Mazzotta, P.;
McGehee, P.;
Melchiorri, A.;
Mendes, L.;
Mennella, A.;
Migliaccio, M.;
Miniussi, A.;
Mitra, S.;
Miville-Deschênes, M. -A.;
Moneti, A.;
Montier, L.;
Morgante, G.;
Mortlock, D.;
Mottet, S.;
Munshi, D.;
Murphy, J. A.;
Naselsky, P.;
Nati, F.;
Natoli, P.;
Netterfield, C. B.;
Nørgaard-Nielsen, H. U.;
Noviello, F.;
Novikov, D.;
Novikov, I.;
Osborne, S.;
Oxborrow, C. A.;
Paci, F.;
Pagano, L.;
Pajot, F.;
Paoletti, D.;
Pasian, F.;
Patanchon, G.;
Perdereau, O.;
Perotto, L.;
Perrotta, F.;
Piacentini, F.;
Piat, M.;
Pierpaoli, E.;
Pietrobon, D.;
Plaszczynski, S.;
Pointecouteau, E.;
Polenta, G.;
Ponthieu, N.;
Popa, L.;
Poutanen, T.;
Pratt, G. W.;
Prézeau, G.;
Prunet, S.;
Puget, J. -L.;
Rachen, J. P.;
Racine, B.;
Reinecke, M.;
Remazeilles, M.;
Renault, C.;
Ricciardi, S.;
Riller, T.;
Ristorcelli, I.;
Rocha, G.;
Rosset, C.;
Roudier, G.;
Rusholme, B.;
Sanselme, L.;
Santos, D.;
Sauvé, A.;
Savini, G.;
Shellard, E. P. S.;
Spencer, L. D.;
Starck, J. -L.;
Stolyarov, V.;
Stompor, R.;
Sudiwala, R.;
Sureau, F.;
Sutton, D.;
Suur-Uski, A. -S.;
Sygnet, J. -F.;
Tauber, J. A.;
Tavagnacco, D.;
Terenzi, L.;
Toffolatti, L.;
Tomasi, M.;
Tristram, M.;
Tucci, M.;
Umana, G.;
Valenziano, L.;
Valiviita, J.;
Van Tent, B.;
Vielva, P.;
Villa, F.;
Vittorio, N.;
Wade, L. A.;
Wandelt, B. D.;
Yvon, D.;
Zacchei, A.;
Zonca, A.
Submitted: 2013-03-20, last modified: 2013-03-26
This paper presents the detection, interpretation and removal of the signal
resulting from interactions of high energy particles with the Planck High
Frequency Instrument (HFI). These interactions fall into two categories,
heating the 0.1 K bolometer plate and glitches in each detector time stream.
Glitch shapes are not simple single pole exponential decays and fall into a
three families. The glitch shape for each family has been characterized
empirically in flight data and removed from the detector time streams. The
spectrum of the count rate/unit energy is computed for each family and a
correspondence to where on the detector the particle hit is made. Most of the
detected glitches are from galactic protons incident on the Si die frame
supporting the micromachined bolometric detectors. At HFI, the particle flux is
~ 5 per square cm and per second and is dominated by protons incident on the
spacecraft with an energy >39 MeV, leading to a rate of typically one event per
second and per detector. Different categories of glitches have different
signature in timestreams. Two of the glitch types have a low amplitude
component that decays over nearly 1 second. This component produces an excess
noise if not properly removed from the time ordered data. We have used a glitch
detection and subtraction method based on the joint fit of population
templates. The application of this novel glitch removal method removes excess
noise from glitches. Using realistic simulations, we find this method does not
introduce signal bias.