Normalized to: Mimura, T.
[1]
oai:arXiv.org:1805.08344 [pdf] - 1686974
In-orbit performance and calibration of the Hard X-ray Imager onboard
Hitomi (ASTRO-H)
Hagino, Kouichi;
Nakazawa, Kazuhiro;
Sato, Goro;
Kokubun, Motohide;
Enoto, Teruaki;
Fukazawa, Yasushi;
Hayashi, Katsuhiro;
Kataoka, Jun;
Katsuta, Junichiro;
Kobayashi, Shogo B.;
Laurent, Philippe;
Lebrun, Francois;
Limousin, Olivier;
Maier, Daniel;
Makishima, Kazuo;
Mimura, Taketo;
Miyake, Katsuma;
Mizuno, Tsunefumi;
Mori, Kunishiro;
Murakami, Hiroaki;
Nakamori, Takeshi;
Nakano, Toshio;
Noda, Hirofumi;
Odaka, Hirokazu;
Ohno, Masanori;
Ohta, Masayuki;
Saito, Shinya;
Sato, Rie;
Tajima, Hiroyasu;
Takahashi, Hiromitsu;
Takahashi, Tadayuki;
Takeda, Shin'ichiro;
Tanaka, Takaaki;
Terada, Yukikatsu;
Uchiyama, Hideki;
Uchiyama, Yasunobu;
Watanabe, Shin;
Yamaoka, Kazutaka;
Yatsu, Yoichi;
Yuasa, Takayuki
Submitted: 2018-05-21
The Hard X-ray Imager (HXI) onboard Hitomi (ASTRO-H) is an imaging
spectrometer covering hard X-ray energies of 5-80 keV. Combined with the hard
X-ray telescope, it enables imaging spectroscopy with an angular resolution of
$1^\prime.7$ half-power diameter, in a field of view of
$9^\prime\times9^\prime$. The main imager is composed of 4 layers of Si
detectors and 1 layer of CdTe detector, stacked to cover wide energy band up to
80 keV, surrounded by an active shield made of BGO scintillator to reduce the
background. The HXI started observations 12 days before the Hitomi loss, and
successfully obtained data from G21.5$-$0.9, Crab and blank sky. Utilizing
these data, we calibrate the detector response and study properties of in-orbit
background. The observed Crab spectra agree well with a powerlaw model
convolved with the detector response, within 5% accuracy. We find that albedo
electrons in specified orbit strongly affect the background of Si top layer,
and establish a screening method to reduce it. The background level over the
full field of view after all the processing and screening is as low as the
pre-flight requirement of $1$-$3\times10^{-4}$ counts s$^{-1}$ cm$^{-2}$
keV$^{-1}$.
[2]
oai:arXiv.org:1804.00827 [pdf] - 1663445
Modeling of proton-induced radioactivation background in hard X-ray
telescopes: Geant4-based simulation and its demonstration by Hitomi's
measurement in a low Earth orbit
Odaka, Hirokazu;
Asai, Makoto;
Hagino, Kouichi;
Koi, Tatsumi;
Madejski, Greg;
Mizuno, Tsunefumi;
Ohno, Masanori;
Saito, Shinya;
Sato, Tamotsu;
Wright, Dennis H.;
Enoto, Teruaki;
Fukazawa, Yasushi;
Hayashi, Katsuhiro;
Kataoka, Jun;
Katsuta, Junichiro;
Kawaharada, Madoka;
Kobayashi, Shogo B.;
Kokubun, Motohide;
Laurent, Philippe;
Lebrun, Francois;
Limousin, Olivier;
Maier, Daniel;
Makishima, Kazuo;
Mimura, Taketo;
Miyake, Katsuma;
Mori, Kunishiro;
Murakami, Hiroaki;
Nakamori, Takeshi;
Nakano, Toshio;
Nakazawa, Kazuhiro;
Noda, Hirofumi;
Ohta, Masayuki;
Ozaki, Masanobu;
Sato, Goro;
Sato, Rie;
Tajima, Hiroyasu;
Takahashi, Hiromitsu;
Takahashi, Tadayuki;
Takeda, Shin'ichiro;
Tanaka, Takaaki;
Tanaka, Yasuyuki;
Terada, Yukikatsu;
Uchiyama, Hideki;
Uchiyama, Yasunobu;
Watanabe, Shin;
Yamaoka, Kazutaka;
Yasuda, Tetsuya;
Yatsu, Yoichi;
Yuasa, Takayuki;
Zoglauer, Andreas
Submitted: 2018-04-03
Hard X-ray astronomical observatories in orbit suffer from a significant
amount of background due to radioactivation induced by cosmic-ray protons
and/or geomagnetically trapped protons. Within the framework of a full Monte
Carlo simulation, we present modeling of in-orbit instrumental background
dominated by radioactivation. To reduce the computation time required by
straightforward simulations of delayed emissions from activated isotopes, we
insert a semi-analytical calculation that converts production probabilities of
radioactive isotopes by interaction of the primary protons into decay rates at
measurement time of all secondary isotopes. Therefore, our simulation method is
separated into three steps: (1) simulation of isotope production, (2)
semi-analytical conversion to decay rates, and (3) simulation of decays of the
isotopes at measurement time. This method is verified by a simple setup that
has a CdTe semiconductor detector, and shows a 100-fold improvement in
efficiency over the straightforward simulation. The simulation framework was
tested against data measured with a CdTe sensor in the Hard X-ray Imager
onboard the Hitomi X-ray Astronomy Satellite, which was put into a low Earth
orbit with an altitude of 570 km and an inclination of 31 degrees, and thus
experienced a large amount of irradiation from geomagnetically trapped protons
during its passages through the South Atlantic Anomaly. The simulation is able
to treat full histories of the proton irradiation and multiple measurement
windows. The simulation results agree very well with the measured data, showing
that the measured background is well described by the combination of
proton-induced radioactivation of the CdTe detector itself and thick Bi4Ge3O12
scintillator shields, leakage of cosmic X-ray background and albedo gamma-ray
radiation, and emissions from naturally contaminated isotopes in the detector
system.