Normalized to: Miley, H.
[1]
oai:arXiv.org:1401.6234 [pdf] - 931856
Maximum Likelihood Signal Extraction Method Applied to 3.4 years of
CoGeNT Data
Aalseth, C. E.;
Barbeau, P. S.;
Leon, J. Diaz;
Fast, J. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.
Submitted: 2014-01-23, last modified: 2015-02-05
CoGeNT has taken data for over 3 years, with 1136 live days of data
accumulated as of April 23, 2013. We report on the results of a maximum
likelihood analysis to extract any possible dark matter signal present in the
collected data. The maximum likelihood signal extraction uses 2-dimensional
probability density functions (PDFs) to characterize the anticipated variations
in dark matter interaction rates for given observable nuclear recoil energies
during differing periods of the Earth's annual orbit around the Sun. Cosmogenic
and primordial radioactivity backgrounds are characterized by their energy
signatures and in some cases decay half-lives. A third parameterizing variable
-- pulse rise-time -- is added to the likelihood analysis to characterize slow
rising pulses described in prior analyses. The contribution to each event
category is analyzed for various dark matter signal hypotheses including a dark
matter standard halo model and a case with free oscillation parameters (i.e.,
amplitude, period, and phase). The best-fit dark matter signal is in close
proximity to previously reported results. We find that the significance of the
extracted dark matter signal remains well below evidentiary at 1.7 $\sigma$.
[2]
oai:arXiv.org:1401.3295 [pdf] - 770398
Search for An Annual Modulation in Three Years of CoGeNT Dark Matter
Detector Data
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2014-01-14
Weakly Interacting Massive Particles (WIMPs) are well-established dark matter
candidates. WIMP interactions with sensitive detectors are expected to display
a characteristic annual modulation in rate. We release a dataset spanning 3.4
years of operation from a low-background germanium detector, designed to search
for this signature. A previously reported modulation persists, concentrated in
a region of the energy spectrum populated by an exponential excess of unknown
origin. Its phase and period agree with phenomenological expectations, but its
amplitude is a factor $\sim$4-7 larger than predicted for a standard WIMP
galactic halo. We consider the possibility of a non-Maxwellian local halo
velocity distribution as a plausible explanation, able to help reconcile
recently reported WIMP search anomalies.
[3]
oai:arXiv.org:1208.5737 [pdf] - 690015
CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact
Germanium Detectors
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N. E.;
Hossbach, T. W.;
Knecht, A.;
Kos, M. S.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Yocum, K. M.
Submitted: 2012-08-28, last modified: 2013-04-29
CoGeNT employs p-type point-contact (PPC) germanium detectors to search for
Weakly Interacting Massive Particles (WIMPs). By virtue of its low energy
threshold and ability to reject surface backgrounds, this type of device allows
an emphasis on low-mass dark matter candidates (wimp mass of about 10 GeV/c2).
We report on the characteristics of the PPC detector presently taking data at
the Soudan Underground Laboratory, elaborating on aspects of shielding, data
acquisition, instrumental stability, data analysis, and background estimation.
A detailed background model is used to investigate the low energy excess of
events previously reported, and to assess the possibility of temporal
modulations in the low-energy event rate. Extensive simulations of all
presently known backgrounds do not provide a viable background explanation for
the excess of low-energy events in the CoGeNT data, or the previously observed
temporal variation in the event rate. Also reported on for the first time is a
determination of the surface (slow pulse rise time) event contamination in the
data as a function of energy. We conclude that the CoGeNT detector technology
is well suited to search for the annual modulation signature expected from dark
matter particle interactions in the region of WIMP mass and coupling favored by
the DAMA/LIBRA results
[4]
oai:arXiv.org:1106.3014 [pdf] - 1077303
Final Analysis and Results of the Phase II SIMPLE Dark Matter Search
Felizardo, M.;
Girard, T. A.;
Morlat, T.;
Fernandes, A. C.;
Ramos, A. R.;
Marques, J. G.;
Auguste, M.;
Boyer, D.;
Cavaillou, A.;
Poupeney, J.;
Sudre, C.;
Puibasset, J.;
Miley, H. S.;
Payne, R. F.;
Carvalho, F. P.;
Prudêncio, M. I.;
Marques, R.
Submitted: 2011-06-15, last modified: 2012-04-09
We report the final results of the Phase II SIMPLE measurements, comprising
two run stages of 15 superheated droplet detectors each, the second stage
including an improved neutron shielding. The analyses includes a refined signal
analysis, and revised nucleation efficiency based on reanalysis of
previously-reported monochromatic neutron irradiations. The combined results
yield a contour minimum of \sigma_{p} = 4.2 x 10^-3 pb at 35 GeV/c^2 on the
spin-dependent sector of WIMP-proton interactions, the most restrictive to date
from a direct search experiment and overlapping for the first time results
previously obtained only indirectly. In the spin-independent sector, a minimum
of 3.6 x 10^-6 pb at 35 GeV/c^2 is achieved, with the exclusion contour
challenging the recent CoGeNT region of current interest.
[5]
oai:arXiv.org:1106.0650 [pdf] - 669552
Search for an Annual Modulation in a P-type Point Contact Germanium Dark
Matter Detector
Aalseth, C. E.;
Barbeau, P. S.;
Colaresi, J.;
Collar, J. I.;
Leon, J. Diaz;
Fast, J. E.;
Fields, N.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Knecht, A.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2011-06-03, last modified: 2011-10-04
Fifteen months of cumulative CoGeNT data are examined for indications of an
annual modulation, a predicted signature of Weakly Interacting Massive Particle
(WIMP) interactions. Presently available data support the presence of a
modulated component of unknown origin, with parameters prima facie compatible
with a galactic halo composed of light-mass WIMPs. Unoptimized estimators yield
a statistical significance for a modulation of ~2.8 sigma, limited by the short
exposure.
[6]
oai:arXiv.org:1003.2987 [pdf] - 272101
First Results of the Phase II SIMPLE Dark Matter Search
Felizardo, M.;
Morlat, T.;
Fernandes, A. C.;
Girard, TA;
Marques, J. G.;
Ramos, A. R.;
Auguste, M.;
Boyer, D.;
Cavaillou, A.;
Sudre, C.;
Poupeney, J.;
Payne, R. F.;
Miley, H. S.;
Puibasset, J.
Submitted: 2010-03-15, last modified: 2010-10-20
We report results of a 14.1 kgd measurement with 15 superheated droplet
detectors of total active mass 0.208 kg, comprising the first stage of a 30 kgd
Phase II experiment. In combination with the results of the neutron-spin
sensitive XENON10 experiment, these results yield a limit of |a_p| < 0.32 for
M_W = 50 GeV/c2 on the spin-dependent sector of weakly interacting massive
particle-nucleus interactions with a 50% reduction in the previously allowed
region of the phase space formerly defined by XENON, KIMS and PICASSO. In the
spin-independent sector, a limit of 2.3x10-5 pb at M_W = 45 GeV/c2 is obtained.
[7]
oai:arXiv.org:1002.4703 [pdf] - 339357
Results from a Search for Light-Mass Dark Matter with a P-type Point
Contact Germanium Detector
Aalseth, C. E.;
Barbeau, P. S.;
Bowden, N. S.;
Cabrera-Palmer, B.;
Colaresi, J.;
Collar, J. I.;
Dazeley, S.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Fields, N.;
Greenberg, C. H.;
Hossbach, T. W.;
Keillor, M. E.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Miller, M. L.;
Orrell, J. L.;
Radford, D. C.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R. L.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2010-02-25, last modified: 2010-03-15
We report on several features present in the energy spectrum from an ultra
low-noise germanium detector operated at 2,100 m.w.e. By implementing a new
technique able to reject surface events, a number of cosmogenic peaks can be
observed for the first time. We discuss several possible causes for an
irreducible excess of bulk-like events below 3 keVee, including a dark matter
candidate common to the DAMA/LIBRA annual modulation effect, the hint of a
signal in CDMS, and phenomenological predictions. Improved constraints are
placed on a cosmological origin for the DAMA/LIBRA effect.
[8]
oai:arXiv.org:0704.2037 [pdf] - 446
A CF3I-based SDD Prototype for Spin-independent Dark Matter Searches
Morlata, T.;
Felizardo, M.;
Giuliani, F.;
Girard, TA;
Waysand, G.;
Payne, R. F.;
Miley, H. S.;
Ramos, A. R.;
Marques, J. G.;
Martins, R. C.;
Limagne, D.
Submitted: 2007-04-16, last modified: 2008-08-26
The application of Superheated Droplet Detectors (SDDs) to dark matter
searches has so far been confined to the light nuclei refrigerants C2ClF5 and
C4F10 (SIMPLE and PICASSO, respectively), with a principle sensitivity to
spin-dependent interactions. Given the competitive results of these devices, as
a result of their intrinsic insensitivity to backgrounds, we have developed a
prototype trifluoroiodomethane (CF3I)-loaded SDD with increased sensitivity to
spin-independent interactions as well. A low (0.102 kgd) exposure test
operation of two high concentration, 1 liter devices is described, and the
results compared with leading experiments in both spin-dependent and
-independent sectors. Although competitive in both sectors when the difference
in exposures is accounted for, a problem with fracturing of the detector gel
must be addressed before significantly larger exposures can be envisioned.
[9]
oai:arXiv.org:0807.0879 [pdf] - 14236
Experimental constraints on a dark matter origin for the DAMA annual
modulation effect
Aalseth, C. E.;
Barbeau, P. S.;
Cerdeno, D. G.;
Colaresi, J.;
Collar, J. I.;
de Lurgio, P.;
Drake, G.;
Fast, J. E.;
Greenberg, C. H.;
Hossbach, T. W.;
Kephart, J. D.;
Marino, M. G.;
Miley, H. S.;
Orrell, J. L.;
Reyna, D.;
Robertson, R. G. H.;
Talaga, R.;
Tench, O.;
Van Wechel, T. D.;
Wilkerson, J. F.;
Yocum, K. M.
Submitted: 2008-07-05, last modified: 2008-07-31
A claim for evidence of dark matter interactions in the DAMA experiment has
been recently reinforced. We employ a new type of germanium detector to
conclusively rule out a standard isothermal galactic halo of Weakly Interacting
Massive Particles (WIMPs) as the explanation for the annual modulation effect
leading to the claim. Bounds are similarly imposed on a suggestion that dark
pseudoscalars mightlead to the effect. We describe the sensitivity to light
dark matter particles achievable with our device, in particular to
Next-to-Minimal Supersymmetric Model candidates.
[10]
oai:arXiv.org:astro-ph/0211535 [pdf] - 1591945
Status of IGEX dark matter search at Canfranc Underground Laboratory
Irastorza, I. G.;
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Carmona, J. M.;
Cebrian, S.;
Garcia, E.;
Kirpichnikov, I. V.;
Klimenko, A. A.;
Luzon, G.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Osetrov, S. B.;
Pogosov, V. S.;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Smolnikov, A. A.;
Tamanyan, A. G.;
Vasenko, A. A.;
Vasiliev, S. I.;
Villar, J. A.
Submitted: 2002-11-25
One IGEX 76Ge double-beta decay detector is currently operating in the
Canfranc Underground Laboratory in a search for dark matter WIMPs, through the
Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we
report on the on-going efforts to understand and eventually reject the
background at low energy. These efforts have led to the improvement of the
neutron shielding and to partial reduction of the background, but still the
remaining events are not totally identified. A tritium contamination or
muon-induced neutrons are considered as possible sources, simulations and
experimental test being still under progress. According to the success of this
study we comment the prospects of the experiment as well as those of its future
extension, the GEDEON dark matter experiment.
[11]
oai:arXiv.org:hep-ex/0101037 [pdf] - 113338
Particle Dark Matter and Solar Axion Searches with a small germanium
detector at the Canfranc Underground Laboratory
Morales, A.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Irastorza, I. G.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2001-01-22
A small, natural abundance, germanium detector (COSME) has been operating
recently at the Canfranc Underground Laboratory (Spanish Pyrenees) in improved
conditions of shielding and overburden with respect to a previous operation of
the same detector. An exposure of 72.7 kg day in these conditions has at
present a background improvement of about one order of magnitude compared to
the former operation of the detector. These new data have been applied to a
direct search for WIMPs and solar axions. New WIMP exclusion plots improving
the current bounds for low masses are reported. The paper also presents a limit
on the axion-photon coupling obtained from the analysis of the data looking for
a Primakoff axion-to-photon conversion and Bragg scattering inside the crystal.
[12]
oai:arXiv.org:astro-ph/0101176 [pdf] - 1507852
WIMP searches with superheated droplet detectors: Status and Prospects
Submitted: 2001-01-11, last modified: 2001-01-14
SIMPLE (Superheated Instrument for Massive ParticLE searches) employs
superheated droplet detectors (SDDs) to search for Weakly Interacting Massive
Particle (WIMP) dark matter. As a result of the intrinsic SDD insensitivity to
minimum ionizing particles and high fluorine content of target liquids,
competitive WIMP limits were already obtained at the early prototype stage. We
comment here on the expected immediate increase in sensitivity of the program
and on future plans to exploit this promising technnique.
[13]
oai:arXiv.org:hep-ph/0011318 [pdf] - 1507915
Recent results from the canfranc dark matter search with germanium
detectors
Irastorza, I. G.;
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Hensley, W. K.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Villar, J. A.
Submitted: 2000-11-27
Two germanium detectors are currently operating in the Canfranc Underground
Laboratory at 2450 m.w.e looking for WIMP dark matter. One is a 2 kg 76Ge IGEX
detector (RG-2) which has an energy threshold of 4 keV and a low-energy
background rate of about 0.3 c/keV/kg/day. The other is a small (234 g) natural
abundance Ge detector (COSME), of low energy threshold (2.5 keV) and an energy
resolution of 0.4 keV at 10 keV which is looking for WIMPs and for solar
axions. The analysis of 73 kg-days of data taken by COSME in a search for solar
axions via their photon Primakoff conversion and Bragg scattering in the Ge
crystal yields a 95% C.L. limit for the axion-photon coupling g < 2.8 10^-9
GeV^-1. These data, analyzed for WIMP searches provide an exclusion plot for
WIMP-nucleon spin-independent interaction which improves previous plots in the
low mass region. On the other hand, the exclusion plot derived from the 60
kg-days of data from the RG-2 IGEX detector improves the exclusion limits
derived from other ionization (non thermal) germanium detector experiments in
the region of WIMP masses from 30 to 100 GeV recently singled out by the
reported DAMA annual modulation effect.
[14]
oai:arXiv.org:astro-ph/0001511 [pdf] - 34308
First Dark Matter Limits from a Large-Mass, Low-Background Superheated
Droplet Detector
Submitted: 2000-01-28, last modified: 2000-09-29
We report on the fabrication aspects and calibration of the first large
active mass ($\sim15$ g) modules of SIMPLE, a search for particle dark matter
using Superheated Droplet Detectors (SDDs). While still limited by the
statistical uncertainty of the small data sample on hand, the first weeks of
operation in the new underground laboratory of Rustrel-Pays d'Apt already
provide a sensitivity to axially-coupled Weakly Interacting Massive Particles
(WIMPs) competitive with leading experiments, confirming SDDs as a convenient,
low-cost alternative for WIMP detection.
[15]
oai:arXiv.org:astro-ph/0005059 [pdf] - 35831
Prospects for SIMPLE 2000: A large-mass, low-background Superheated
Droplet Detector for WIMP searches
Submitted: 2000-05-03
SIMPLE 2000 (Superheated Instrument for Massive ParticLE searches) will
consist of an array of eight to sixteen large active mass ($\sim15$ g)
Superheated Droplet Detectors(SDDs) to be installed in the new underground
laboratory of Rustrel-Pays d'Apt. Several factors make of SDDs an attractive
approach for the detection of Weakly Interacting Massive Particles (WIMPs),
namely their intrinsic insensitivity to minimum ionizing particles, high
fluorine content, low cost and operation near ambient pressure and temperature.
We comment here on the fabrication, calibration and already-competitive first
limits from SIMPLE prototype SDDs, as well as on the expected immediate
increase in sensitivity of the program, which aims at an exposure of $>$25
kg-day during the year 2000. The ability of modest-mass fluorine-rich detectors
to explore regions of neutralino parameter space beyond the reach of the most
ambitious cryogenic projects is pointed out.
[16]
oai:arXiv.org:hep-ex/0002053 [pdf] - 113328
New constraints on WIMPs from the Canfranc IGEX dark matter search
Morales, A.;
Aalseth, C. E.;
Avignone, F. T.;
Brodzinski, R. L.;
Cebrian, S.;
Garcia, E.;
Gonzalez, D.;
Hensley, W. K.;
Irastorza, I. G.;
Kirpichnikov, I. V.;
Klimenko, A. A.;
Miley, H. S.;
Morales, J.;
de Solorzano, A. Ortiz;
Osetrov, S. B.;
Pogosov, V. S.;
Puimedon, J.;
Reeves, J. H.;
Sarsa, M. L.;
Scopel, S.;
Smolnikov, A. A.;
Tamanyan, A. G.;
Vasenko, A. A.;
Vasiliev, S. I.;
Villar, J. A.
Submitted: 2000-02-21
The IGEX Collaboration enriched 76Ge double-beta decay detectors are
currently operating in the Canfranc Underground Laboratory with an overburden
of 2450 m.w.e. A recent upgrade has made it possible to use them in a search
for WIMPs. A new exclusion plot has been derived for WIMP-nucleon
spin-independent interaction. To obtain this result, 30 days of data from one
IGEX detector, which has an energy threshold of ~4 keV, have been considered.
These data improve the exclusion limits derived from other germanium diode
experiments in the ~50 GeV DAMA region, and show that with a moderate
improvement of the background below 10 keV, the DAMA region may be tested with
an additional 1 kg-year of exposure.
[17]
oai:arXiv.org:astro-ph/9801176 [pdf] - 100025
A Decommissioned LHC Model Magnet as an Axion Telescope
Zioutas, K.;
Aalseth, C. E.;
Abriola, D.;
Avignone, F. T.;
Brodzinski, R. L.;
Collar, J. I.;
Creswick, R.;
Di Gregorio, D. E.;
Farach, H.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Hasinoff, M.;
Huck, H.;
Liolios, A.;
Miley, H. S.;
Morales, A.;
Morales, J.;
Nikas, D.;
Nussinov, S.;
Ortiz, A.;
Savvidis, E.;
Scopel, S.;
Sievers, P.;
Villar, J. A.;
Walckiers, L.
Submitted: 1998-01-18, last modified: 1999-01-22
The 8.4 Tesla, 10 m long transverse magnetic field of a twin aperture LHC
bending magnet can be utilized as a macroscopic coherent solar axion-to-photon
converter. Numerical calculations show that the integrated time of alignment
with the Sun would be 33 days per year with the magnet on a tracking table
capable of $\pm 5^o$ in the vertical direction and $\pm 40^o$ in the horizontal
direction. The existing lower bound on the axion-to-photon coupling constant
can be improved by a factor between 50 and 100 in 3 years, i.e.,
$g_{a\gamma\gamma} \lesssim 9\cdot 10^{-11} GeV^{-1}$ for axion masses
$\lesssim$ 1 eV. This value falls within the existing open axion mass window.
The same set-up can simultaneously search for low- and high-energy celestial
axions, or axion-like particles, scanning the sky as the Earth rotates and
orbits the Sun.
[18]
oai:arXiv.org:astro-ph/9809018 [pdf] - 102722
Search for an annual modulation of dark-matter signals with a germanium
spectrometer at the Sierra Grande Laboratory
Abriola, D.;
Avignone, F. T.;
Brodzinski, R. L.;
Collar, J. I.;
Di Gregorio, D. E.;
Farach, H. A.;
Garcia, E.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Huck, H.;
Miley, H. S.;
Morales, A.;
Morales, J.;
de Solorzano, A. Ortiz;
Puimedon, J.;
Reeves, J. H.;
Salinas, A.;
Sarsa, M. L.;
Villar, J. A.
Submitted: 1998-09-02, last modified: 1998-09-14
Data collected during three years with a germanium spectrometer at the Sierra
Grande underground laboratory have been analyzed for distinctive features of
annual modulation of the signal induced by WIMP dark matter candidates. The
main motivation for this analysis was the recent suggestion by the DAMA/NaI
Collaboration that a yearly modulation signal could not be rejected at the 90%
confidence level when analyzing data obtained with a high-mass low-background
scintillator detector. We performed two different analyses of the data: First,
the statistical distribution of modulation-significance variables (expected
from an experiment running under the conditions of Sierra Grande) was compared
with the same variables obtained from the data. Second, the data were analyzed
in energy bins as an independent check of the first result and to allow for the
possibility of a crossover in the expected signal. In both cases no
statistically significant deviation from the null result was found, which could
support the hypothesis that the data contain a modulated component. A plot is
also presented to enable the comparison of these results to those of the DAMA
collaboration.
[19]
oai:arXiv.org:astro-ph/9712308 [pdf] - 1235170
Experimental Search for Solar Axions
Gattone, A. O.;
Abriola, D.;
Avignone, F. T.;
Brodzinski, R. L.;
Collar, J. I.;
Creswick, R. J.;
Di Gregorio, D. E.;
Farach, H. A.;
Guérard, C. K.;
Hasenbalg, F.;
Huck, H.;
Miley, H. S.;
Morales, A.;
Morales, J.;
Nussinov, S.;
de Solórzano, A. Ortiz;
Reeves, J. H.;
Villar, J. A.;
Zioutas, K.
Submitted: 1997-12-23, last modified: 1997-12-26
A new technique has been used to search for solar axions using a single
crystal germanium detector. It exploits the coherent conversion of axions into
photons when their angle of incidence satisfies a Bragg condition with a
crystalline plane. The analysis of approximately 1.94 kg.yr of data from the
1-kg DEMOS detector in Sierra Grande, Argentina, yields a new laboratory bound
on axion-photon coupling of g_{a,\gamma\gamma}<2.7\times 10^{-9} GeV^{-1}
independent of axion mass up to \sim 1 keV.
[20]
oai:arXiv.org:astro-ph/9708008 [pdf] - 98186
Experimental Search for Solar Axions via Coherent Primakoff Conversion
in a Germanium Spectrometer
Avignone, F. T.;
Abriola, D.;
Brodzinski, R. L.;
Collar, J. I.;
Creswick, R. J.;
DiGregorio, D. E.;
Farach, H. A.;
Gattone, A. O.;
Guerard, C. K.;
Hasenbalg, F.;
Huck, H.;
Miley, H. S.;
Morales, A.;
Morales, J.;
Nussinov, S.;
de Solorzano, A. Ortiz;
Reeves, J. H.;
Villar, J. A.;
Zioutas, K.
Submitted: 1997-08-01
Results are reported of an experimental search for the unique, rapidly
varying temporal pattern of solar axions coherently converting into photons via
the Primakoff effect in a single crystal germanium detector. This conversion is
predicted when axions are incident at a Bragg angle with a crystalline plane.
The analysis of approximately 1.94 kg.yr of data from the 1 kg DEMOS detector
in Sierra Grande, Argentina, yields a new laboratory bound on axion-photon
coupling of $g_{a\gamma \gamma} < 2.7\cdot 10^{-9}$ GeV$^{-1}$, independent of
axion mass up to ~ 1 keV.