Normalized to: Meunier, P.
[1]
oai:arXiv.org:1010.4290 [pdf] - 286319
Low-threshold analysis of CDMS shallow-site data
CDMS Collaboration;
Akerib, D. S.;
Attisha, M. J.;
Baudis, L.;
Bauer, D. A.;
Bolozdynya, A. I.;
Brink, P. L.;
Bunker, R.;
Cabrera, B.;
Caldwell, D. O.;
Chang, C. L.;
Clarke, R. M.;
Cooley, J.;
Crisler, M. B.;
Cushman, P.;
DeJongh, F.;
Dixon, R.;
Driscoll, D. D.;
Filippini, J.;
Funkhouser, S.;
Gaitskell, R. J.;
Golwala, S. R.;
Holmgren, D.;
Hsu, L.;
Huber, M. E.;
Kamat, S.;
Mahapatra, R.;
Mandic, V.;
Meunier, P.;
Mirabolfathi, N.;
Moore, D.;
Nam, S. W.;
Nelson, H.;
Ogburn, R. W.;
Qiu, X.;
Rau, W.;
Reisetter, A.;
Saab, T.;
Sadoulet, B.;
Sander, J.;
Savage, C.;
Schnee, R. W.;
Seitz, D. N.;
Shutt, T. A.;
Wang, G.;
Yellin, S.;
Yoo, J.;
Young, B. A.
Submitted: 2010-10-20, last modified: 2011-01-03
Data taken during the final shallow-site run of the first tower of the
Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with
improved sensitivity to small energy depositions. Four ~224 g germanium and two
~105 g silicon detectors were operated at the Stanford Underground Facility
(SUF) between December 2001 and June 2002, yielding 118 live days of raw
exposure. Three of the germanium and both silicon detectors were analyzed with
a new low-threshold technique, making it possible to lower the germanium and
silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and
~2 keV, respectively. Limits on the spin-independent cross section for weakly
interacting massive particles (WIMPs) to elastically scatter from nuclei based
on these data exclude interesting parameter space for WIMPs with masses below 9
GeV/c^2. Under standard halo assumptions, these data partially exclude
parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT
experiments' data as WIMP signals, and exclude new parameter space for WIMP
masses between 3 GeV/c^2 and 4 GeV/c^2.
[2]
oai:arXiv.org:astro-ph/0503583 [pdf] - 880834
Beyond the CDMS-II Dark Matter Search: SuperCDMS
Brink, P. L.;
Cabrera, B.;
Chang, C. L.;
Cooley, J.;
Ogburn, R. W.;
Akerib, D. S.;
Bailey, C. N.;
Brusov, P. P.;
Dragowsky, M. R.;
Grant, D. R.;
Hennings-Yeomans, R.;
Schnee, R. W.;
Attisha, M. J.;
Gaitskell, R. J.;
Thompson, J-P. F.;
Baudis, L.;
Saab, T.;
Bauer, D. A.;
Crisler, M. B.;
Holmgren, D.;
Ramberg, E.;
Yoo, J.;
Bunker, R.;
Caldwell, D. O.;
Mahapatra, R.;
Nelson, H.;
Sander, J.;
Yellin, S.;
Cushman, P.;
Duong, L.;
Reisetter, A.;
Denes, P.;
Lu, A.;
Sadoulet, B.;
Filippini, J.;
Meunier, P.;
Mirabolfathi, N.;
Seitz, D. N.;
Serfass, B.;
Sundqvist, K. M.;
Golwala, S. R.;
Huber, M. E.;
Irwin, K. D.;
Young, B. A.
Submitted: 2005-03-27
Presently the CDMS-II collaboration's Weakly Interacting Massive Particle
(WIMP) search at the Soudan Underground Laboratory sets the most stringent
exclusion limits of any WIMP cold dark matter direct-detection experiment. To
extend our reach further, to WIMP-nucleon cross sections in the range $10^{-46}
- 10^{-44}$cm$^2$, we propose SuperCDMS, which would take advantage of a very
deep site. One promising site is the recently approved SNOLab facility in
Canada. In this paper we will present our overall plan, identify primary
issues, and set the goals that need to be met prior to embarking upon each
phase of SuperCDMS.