sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mercier, K.

Normalized to: Mercier, K.

6 article(s) in total. 281 co-authors, from 1 to 5 common article(s). Median position in authors list is 19,5.

[1]  oai:arXiv.org:1610.06892  [pdf] - 1500539
The Deep and Transient Universe in the SVOM Era: New Challenges and Opportunities - Scientific prospects of the SVOM mission
Comments: 67 pages, 1 frontispiece, 21 figures. Report on the Scientific prospects of the SVOM mission. Proceedings of the Workshop held from 11th to 15th April 2016 at Les Houches School of Physics, France
Submitted: 2016-10-21
To take advantage of the astrophysical potential of Gamma-Ray Bursts (GRBs), Chinese and French astrophysicists have engaged the SVOM mission (Space-based multi-band astronomical Variable Objects Monitor). Major advances in GRB studies resulting from the synergy between space and ground observations, the SVOM mission implements space and ground instrumentation. The scientific objectives of the mission put a special emphasis on two categories of GRBs: very distant GRBs at z$>$5 which constitute exceptional cosmological probes, and faint/soft nearby GRBs which allow probing the nature of the progenitors and the physics at work in the explosion. These goals have a major impact on the design of the mission: the on-board hard X-ray imager is sensitive down to 4 keV and computes on line image and rate triggers, and the follow-up telescopes on the ground are sensitive in the NIR. At the beginning of the next decade, SVOM will be the main provider of GRB positions and spectral parameters on very short time scale. The SVOM instruments will operate simultaneously with a wide range of powerful astronomical devices. This rare instrumental conjunction, combined with the relevance of the scientific topics connected with GRB studies, warrants a remarkable scientific return for SVOM. In addition, the SVOM instrumentation, primarily designed for GRB studies, composes a unique multi-wavelength observatory with rapid slew capability that will find multiple applications for the whole astronomy community beyond the specific objectives linked to GRBs. This report lists the scientific themes that will benefit from observations made with SVOM, whether they are specific GRB topics, or more generally all the issues that can take advantage of the multi-wavelength capabilities of SVOM.
[2]  oai:arXiv.org:1508.05851  [pdf] - 1265119
The ECLAIRs GRB-trigger telescope on-board the future mission SVOM
Comments: 6 pages, 6 figures, published by PoS, proceedings of the conference Swift: 10 Years of Discovery, 2-5 December 2014, La Sapienza University, Rome, Italy
Submitted: 2015-08-24
The Space-based multi-band astronomical Variable Objects Monitor (SVOM) is an approved satellite mission for Gamma-Ray Burst (GRB) studies, developed in cooperation between the Chinese National Space Agency (CNSA), the Chinese Academy of Sciences (CAS), the French Space Agency (CNES) and French laboratories. SVOM entered Phase B in 2014 and is scheduled for launch in 2021. SVOM will provide fast and accurate GRB localizations, and determine the temporal and spectral properties of the GRB emission, thanks to a set of 4 on-board instruments. The trigger system of the coded-mask telescope ECLAIRs images the sky in the 4-120 keV energy range, in order to detect and localize GRBs in its 2 sr-wide field of view. The low-energy threshold of ECLAIRs is well suited for the detection of highly redshifted GRB. The high-energy coverage is extended up to 5 MeV thanks to the non-imaging gamma-ray spectrometer GRM. GRB alerts are sent in real-time to the ground observers community, and a spacecraft slew is performed in order to place the GRB within the field of view of the soft X-ray telescope MXT and the visible-band telescope VT, to refine the GRB position and study its early afterglow. The ground-based robotic telescopes GFTs and the wide angle cameras GWAC complement the on-board instruments. In this paper we present the ECLAIRs soft gamma-ray imager which will provide the GRB triggers on-board SVOM.
[3]  oai:arXiv.org:1507.00204  [pdf] - 1240583
The Microchannel X-ray Telescope on Board the SVOM Satellite
Comments: 6 pages, 6 figures, proceedings of the conference "Swift: 10 years of Discovery", Rome, December 2-5, 2014. To be published by PoS
Submitted: 2015-07-01
We present the Micro-channel X-ray Telescope (MXT), a new narrow-field (about 1{\deg}) telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science, scheduled for launch in 2021. MXT is based on square micro pore optics (MPOs), coupled with a low noise CCD. The optics are based on a "Lobster Eye" design, while the CCD is a focal plane detector similar to the type developed for the seven eROSITA telescopes. MXT is a compact and light (<35 kg) telescope with a 1 m focal length, and it will provide an effective area of about 45 cmsq on axis at 1 keV. The MXT PSF is expected to be better than 4.2 arc min (FWHM) ensuring a localization accuracy of the afterglows of the SVOM GRBs to better than 1 arc min (90\% c.l. with no systematics) provided MXT data are collected within 5 minutes after the trigger. The MXT sensitivity will be adequate to detect the afterglows for almost all the SVOM GRBs as well as to perform observations of non-GRB astrophysical objects. These performances are fully adapted to the SVOM science goals, and prove that small and light telescopes can be used for future small X-ray missions.
[4]  oai:arXiv.org:1407.2406  [pdf] - 1215544
The Microchannel X-ray Telescope for the Gamma-Ray Burst mission SVOM
Comments: 12 pages, 8 figures, to be published in SPIE Astronomical Telescopes + Instrumentation, Montreal, June 2014
Submitted: 2014-07-09
We present the Microchannel X-ray Telescope, a new light and compact focussing telescope that will be flying on the Sino-French SVOM mission dedicated to Gamma-Ray Burst science. The MXT design is based on the coupling of square pore micro-channel plates with a low noise pnCCD. MXT will provide an effective area of about 50 cmsq, and its point spread function is expected to be better than 3.7 arc min (FWHM) on axis. The estimated sensitivity is adequate to detect all the afterglows of the SVOM GRBs, and to localize them to better then 60 arc sec after five minutes of observation.
[5]  oai:arXiv.org:1406.7759  [pdf] - 1215301
The X-/Gamma-ray camera ECLAIRs for the Gammay-ray burst mission SVOM
Comments: 15 pages, 12 figures, Proceeding SPIE - Montreal 2014
Submitted: 2014-06-30
We present ECLAIRs, the Gamma-ray burst (GRB) trigger camera to fly on-board the Chinese-French mission SVOM. ECLAIRs is a wide-field ($\sim 2$\,sr) coded mask camera with a mask transparency of 40\% and a 1024 $\mathrm{cm}^2$ detection plane coupled to a data processing unit, so-called UGTS, which is in charge of locating GRBs in near real time thanks to image and rate triggers. We present the instrument science requirements and how the design of ECLAIRs has been optimized to increase its sensitivity to high-redshift GRBs and low-luminosity GRBs in the local Universe, by having a low-energy threshold of 4 keV. The total spectral coverage ranges from 4 to 150 keV. ECLAIRs is expected to detect $\sim 200$ GRBs of all types during the nominal 3 year mission lifetime. To reach a 4 keV low-energy threshold, the ECLAIRs detection plane is paved with 6400 $4\times 4~\mathrm{mm}^2$ and 1 mm-thick Schottky CdTe detectors. The detectors are grouped by 32, in 8x4 matrices read by a low-noise ASIC, forming elementary modules called XRDPIX. In this paper, we also present our current efforts to investigate the performance of these modules with their front-end electronics when illuminated by charged particles and/or photons using radioactive sources. All measurements are made in different instrument configurations in vacuum and with a nominal in-flight detector temperature of $-20^\circ$C. This work will enable us to choose the in-flight configuration that will make the best compromise between the science performance and the in-flight operability of ECLAIRs. We will show some highlights of this work.
[6]  oai:arXiv.org:1005.5123  [pdf] - 1032799
The Herschel-SPIRE instrument and its in-flight performance
Griffin, M. J.; Abergel, A.; Abreu, A.; Ade, P. A. R.; André, P.; Augueres, J. -L.; Babbedge, T.; Bae, Y.; Baillie, T.; Baluteau, J. -P.; Barlow, M. J.; Bendo, G.; Benielli, D.; Bock, J. J.; Bonhomme, P.; Brisbin, D.; Brockley-Blatt, C.; Caldwell, M.; Cara, C.; Castro-Rodriguez, N.; Cerulli, R.; Chanial, P.; Chen, S.; Clark, E.; Clements, D. L.; Clerc, L.; Coker, J.; Communal, D.; Conversi, L.; Cox, P.; Crumb, D.; Cunningham, C.; Daly, F.; Davis, G. R.; De Antoni, P.; Delderfield, J.; Devin, N.; Di Giorgio, A.; Didschuns, I.; Dohlen, K.; Donati, M.; Dowell, A.; Dowell, C. D.; Duband, L.; Dumaye, L.; Emery, R. J.; Ferlet, M.; Ferrand, D.; Fontignie, J.; Fox, M.; Franceschini, A.; Frerking, M.; Fulton, T.; Garcia, J.; Gastaud, R.; Gear, W. K.; Glenn, J.; Goizel, A.; Griffin, D. K.; Grundy, T.; Guest, S.; Guillemet, L.; Hargrave, P. C.; Harwit, M.; Hastings, P.; Hatziminaoglou, E.; Herman, M.; Hinde, B.; Hristov, V.; Huang, M.; Imhof, P.; Isaak, K. J.; Israelsson, U.; Ivison, R. J.; Jennings, D.; Kiernan, B.; King, K. J.; Lange, A. E.; Latter, W.; Laurent, G.; Laurent, P.; Leeks, S. J.; Lellouch, E.; Levenson, L.; Li, B.; Li, J.; Lilienthal, J.; Lim, T.; Liu, J.; Lu, N.; Madden, S.; Mainetti, G.; Marliani, P.; McKay, D.; Mercier, K.; Molinari, S.; Morris, H.; Moseley, H.; Mulder, J.; Mur, M.; Naylor, D. A.; Nguyen, H.; O'Halloran, B.; Oliver, S.; Olofsson, G.; Olofsson, H. -G.; Orfei, R.; Page, M. J.; Pain, I.; Panuzzo, P.; Papageorgiou, A.; Parks, G.; Parr-Burman, P.; Pearce, A.; Pearson, C.; Pérez-Fournon, I.; Pinsard, F.; Pisano, G.; Podosek, J.; Pohlen, M.; Polehampton, E. T.; Pouliquen, D.; Rigopoulou, D.; Rizzo, D.; Roseboom, I. G.; Roussel, H.; Rowan-Robinson, M.; Rownd, B.; Saraceno, P.; Sauvage, M.; Savage, R.; Savini, G.; Sawyer, E.; Scharmberg, C.; Schmitt, D.; Schneider, N.; Schulz, B.; Schwartz, A.; Shafer, R.; Shupe, D. L.; Sibthorpe, B.; Sidher, S.; Smith, A.; Smith, A. J.; Smith, D.; Spencer, L.; Stobie, B.; Sudiwala, R.; Sukhatme, K.; Surace, C.; Stevens, J. A.; Swinyard, B. M.; Trichas, M.; Tourette, T.; Triou, H.; Tseng, S.; Tucker, C.; Turner, A.; Vaccari, M.; Valtchanov, I.; Vigroux, L.; Virique, E.; Voellmer, G.; Walker, H.; Ward, R.; Waskett, T.; Weilert, M.; Wesson, R.; White, G. J.; Whitehouse, N.; Wilson, C. D.; Winter, B.; Woodcraft, A. L.; Wright, G. S.; Xu, C. K.; Zavagno, A.; Zemcov, M.; Zhang, L.; Zonca, E.
Comments: Accepted for publication in Astronomy & Astrophyics (Herschel first results special issue)
Submitted: 2010-05-27
The Spectral and Photometric Imaging Receiver (SPIRE), is the Herschel Space Observatory`s submillimetre camera and spectrometer. It contains a three-band imaging photometer operating at 250, 350 and 500 microns, and an imaging Fourier Transform Spectrometer (FTS) which covers simultaneously its whole operating range of 194-671 microns (447-1550 GHz). The SPIRE detectors are arrays of feedhorn-coupled bolometers cooled to 0.3 K. The photometer has a field of view of 4' x 8', observed simultaneously in the three spectral bands. Its main operating mode is scan-mapping, whereby the field of view is scanned across the sky to achieve full spatial sampling and to cover large areas if desired. The spectrometer has an approximately circular field of view with a diameter of 2.6'. The spectral resolution can be adjusted between 1.2 and 25 GHz by changing the stroke length of the FTS scan mirror. Its main operating mode involves a fixed telescope pointing with multiple scans of the FTS mirror to acquire spectral data. For extended source measurements, multiple position offsets are implemented by means of an internal beam steering mirror to achieve the desired spatial sampling and by rastering of the telescope pointing to map areas larger than the field of view. The SPIRE instrument consists of a cold focal plane unit located inside the Herschel cryostat and warm electronics units, located on the spacecraft Service Module, for instrument control and data handling. Science data are transmitted to Earth with no on-board data compression, and processed by automatic pipelines to produce calibrated science products. The in-flight performance of the instrument matches or exceeds predictions based on pre-launch testing and modelling: the photometer sensitivity is comparable to or slightly better than estimated pre-launch, and the spectrometer sensitivity is also better by a factor of 1.5-2.