Normalized to: Menz, B.
[1]
oai:arXiv.org:1603.04839 [pdf] - 1374470
Line Spread Functions of Blazed Off-Plane Gratings Operated in the
Littrow Mounting
DeRoo, Casey T.;
McEntaffer, Randall L.;
Miles, Drew M.;
Peterson, Thomas J.;
Marlowe, Hannah;
Tutt, James H.;
Donovan, Benjamin D.;
Menz, Benedikt;
Burwitz, Vadim;
Hartner, Gisela;
Allured, Ryan;
Smith, Randall K.;
Gunther, Ramses;
Yanson, Alex;
Vacanti, Giuseppe;
Ackermann, Marcelo
Submitted: 2016-03-15
Future soft X-ray (10 - 50 Angstrom) spectroscopy missions require higher
effective areas and resolutions to perform critical science that cannot be done
by instruments on current missions. An X-ray grating spectrometer employing
off-plane reflection gratings would be capable of meeting these performance
criteria. Off-plane gratings with blazed groove facets operated in the Littrow
mounting can be used to achieve excellent throughput into orders achieving high
resolutions. We have fabricated two off-plane gratings with blazed groove
profiles via a technique which uses commonly available microfabrication
processes, is easily scaled for mass production, and yields gratings customized
for a given mission architecture. Both fabricated gratings were tested in the
Littrow mounting at the Max-Planck-Institute for extraterrestrial Physics
PANTER X-ray test facility to assess their performance. The line spread
functions of diffracted orders were measured, and a maximum resolution of 800
$\pm$ 20 is reported. In addition, we also observe evidence of a `blaze' effect
from measurements of relative efficiencies of the diffracted orders.
[2]
oai:arXiv.org:1509.02298 [pdf] - 1273356
Profile reconstruction of grazing-incidence X-ray mirrors from
intra-focal X-ray full imaging
Spiga, D.;
Basso, S.;
Bavdaz, M.;
Burwitz, V.;
Civitani, M.;
Citterio, O.;
Ghigo, M.;
Hartner, G.;
Menz, B.;
Pareschi, G.;
Proserpio, L.;
Salmaso, B.;
Tagliaferri, G.;
Wille, E.
Submitted: 2015-09-08
The optics of a number of future X-ray telescopes will have very long focal
lengths (10 - 20 m), and will consist of a number of nested/stacked thin,
grazing-incidence mirrors. The optical quality characterization of a real
mirror can be obtained via profile metrology, and the Point Spread Function of
the mirror can be derived via one of the standard computation methods. However,
in practical cases it can be difficult to access the optical surfaces of
densely stacked mirror shells, after they have been assembled, using the
widespread metrological tools. For this reason, the assessment of the imaging
resolution of a system of mirrors is better obtained via a direct,
full-illumination test in X-rays. If the focus cannot be reached, an
intra-focus test can be performed, and the image can be compared with the
simulation results based on the metrology, if available. However, until today
no quantitative information was extracted from a full-illumination, intra-focal
exposure. In this work we show that, if the detector is located at an optimal
distance from the mirror, the intensity variations of the intra-focal,
full-illumination image in single reflection can be used to reconstruct the
profile of the mirror surface, without the need of a wavefront sensor. The
Point Spread Function can be subsequently computed from the reconstructed
mirror shape. We show the application of this method to an intra-focal (8 m
distance from mirror) test performed at PANTER on an optical module prototype
made of hot-slumped glass foils with a 20 m focal length, from which we could
derive an expected imaging quality near 16 arcsec HEW.
[3]
oai:arXiv.org:1503.05809 [pdf] - 968633
Performance Testing of a Novel Off-plane Reflection Grating and Silicon
Pore Optic Spectrograph at PANTER
Marlowe, Hannah;
McEntaffer, Randall L.;
Allured, Ryan;
DeRoo, Casey;
Miles, Drew M.;
Donovan, Benjamin D.;
Tutt, James H.;
Burwitz, Vadim;
Menz, Benedikt;
Hartner, Gisela D.;
Smith, Randall K.;
Günther, Ramses;
Yanson, Alex;
Vacanti, Giuseppe;
Ackermann, Marcelo
Submitted: 2015-03-19
An X-ray spectrograph consisting of radially ruled off-plane reflection
gratings and silicon pore optics was tested at the Max Planck Institute for
extraterrestrial Physics PANTER X-ray test facility. The silicon pore optic
(SPO) stack used is a test module for the Arcus small explorer mission, which
will also feature aligned off-plane reflection gratings. This test is the first
time two off-plane gratings were actively aligned to each other and with a SPO
to produce an overlapped spectrum. The gratings were aligned using an active
alignment module which allows for the independent manipulation of subsequent
gratings to a reference grating in three degrees of freedom using picomotor
actuators which are controllable external to the test chamber. We report the
line spread functions of the spectrograph and the actively aligned gratings,
and plans for future development.
[4]
oai:arXiv.org:1403.7200 [pdf] - 1208656
The imaging properties of the Gas Pixel Detector as a focal plane
polarimeter
Fabiani, S.;
Costa, E.;
Del Monte, E.;
Muleri, F.;
Soffitta, P.;
Rubini, A.;
Bellazzini, R.;
Brez, A.;
de Ruvo, L.;
Minuti, M.;
Pinchera, M.;
Sgrò, C.;
Spandre, G.;
Spiga, D.;
Tagliaferri, G.;
Pareschi, G.;
Basso, S.;
Citterio, O.;
Burwitz, V.;
Burkert, W.;
Menz, B.;
Hartner, G.
Submitted: 2014-03-27
X-rays are particularly suited to probe the physics of extreme objects.
However, despite the enormous improvements of X-ray Astronomy in imaging,
spectroscopy and timing, polarimetry remains largely unexplored. We propose the
photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate
to fill the gap of more than thirty years of lack of measurements. The GPD, in
the focus of a telescope, will increase the sensitivity of orders of magnitude.
Moreover, since it can measure the energy, the position, the arrival time and
the polarization angle of every single photon, allows to perform polarimetry of
subsets of data singled out from the spectrum, the light curve or the image of
source. The GPD has an intrinsic very fine imaging capability and in this work
we report on the calibration campaign carried out in 2012 at the PANTER X-ray
test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of
Garching (Germany) in which, for the first time, we coupled it to a JET-X
optics module with a focal length of 3.5 m and an angular resolution of 18
arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray
Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small
mission. We derived the imaging and polarimetric performance for extended
sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the
XIPE configuration, discussing also possible improvements by coupling the
detector with advanced optics, having finer angular resolution and larger
effective area, to study with more details extended objects.
[5]
oai:arXiv.org:1311.2220 [pdf] - 786443
Re-testing the JET-X Flight Module No. 2 at the PANTER facility
Spiga, Daniele;
Tagliaferri, Gianpiero;
Soffitta, Paolo;
Citterio, Oberto;
Basso, Stefano;
Bellazzini, Ronaldo;
Brez, Alessandro;
Burkert, Wolfgang;
Burwitz, Vadim;
Costa, Enrico;
de Ruvo, Luca;
Del Monte, Ettore;
Fabiani, Sergio;
Hartner, Gisela;
Menz, Benedikt;
Minuti, Massimo;
Muleri, Fabio;
Pareschi, Giovanni;
Pinchera, Michele;
Rubini, Alda;
Sgrò, Carmelo;
Spandre, Gloria
Submitted: 2013-11-09, last modified: 2014-02-18
The Joint European X-ray Telescope (JET-X) was the core instrument of the
Russian Spectrum-X-gamma space observatory. It consisted of two identical soft
X-ray (0.3 - 10 keV) telescopes with focusing optical modules having a measured
angular resolution of nearly 15 arcsec. Soon after the payload completion, the
mission was cancelled and the two optical flight modules (FM) were brought to
the Brera Astronomical Observatory where they had been manufactured. After 16
years of storage, we have utilized the JET-X FM2 to test at the PANTER X-ray
facility a prototype of a novel X-ray polarimetric telescope, using a Gas Pixel
Detector (GPD) with polarimetric capabilities in the focal plane of the FM2.
The GPD was developed by a collaboration between INFN-Pisa and INAF-IAPS. In
the first phase of the test campaign, we have re-tested the FM2 at PANTER to
have an up-to-date characterization in terms of angular resolution and
effective area, while in the second part of the test the GPD has been placed in
the focal plane of the FM2. In this paper we report the results of the tests of
the sole FM2, using an unpolarized X-ray source, comparing the results with the
calibration done in 1996.