sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

Mei, Hsien-Hao

Normalized to: Mei, H.

4 article(s) in total. 7 co-authors, from 1 to 4 common article(s). Median position in authors list is 1,5.

[1]  oai:arXiv.org:1412.8569  [pdf] - 1420038
New constraints on cosmic polarization rotation from the ACTPol cosmic microwave background B-Mode polarization observation and the BICEP2 constraint update
Comments: 15 pages, 2 figures, 2 tables, version to match the accepted submission to ApJ. Unfortunately there is a sign error in equation (6b). This propagated to equations (7b) and (8a) and to the results for \alpha_\beta. The errors in the last raw of Table 1 had been overestimated and corrected
Submitted: 2014-12-30, last modified: 2016-06-08
Recently ACTPol has measured the cosmic microwave background (CMB) B-mode and E-mode polarizations and obtained TE, EE, BB, TB and EB power spectra in the multipole range 225-8725. In our previous paper (Ap. J. 792 (2014) 35 [Paper I]), we have analyzed jointly the results of three experiments on the CMB B-mode polarization -- SPTpol, POLARBEAR and BICEP2 to include in the model, in addition to the gravitational lensing and the inflationary gravitational waves components, also the fluctuation effects induced by the cosmic polarization rotation (CPR), if it exists within the upper limits at the time. In this paper, we fit both the mean CPR angle <{\alpha}> and its fluctuation <{\delta}{\alpha}2> from the new ACTPol data, and update our fitting of CPR fluctuations using BICEP2 data taking the new Planck dust measurement results into consideration. We follow the method of Paper I. The mean CPR angle is constrained from the EB correlation power spectra to |<{\alpha}>| < 14 mrad (0.8{\deg}) and the fluctuation (rms) is constrained from the BB correlation power spectra to <{\delta}{\alpha}2>1/2 < 29.3 mrad (1.68{\deg}). Assuming that the polarization angle of Tau A does not change from 89.2 to 146 GHz, the ACTPol data give <{\alpha}> = 1.0 {\pm} 0.63{\deg}. These results suggest that the inclusion of the present ACTPol data is consistent with no CPR detection. With the new Planck dust measurement, we update our fits of the BICEP2 CPR fluctuation constraint to be 32.8 mrad (1.88{\deg}). The joint ACTpol-BICEP2-POLARBEAR CPR fluctuation constraint is 23.7 mrad (1.36{\deg}).
[2]  oai:arXiv.org:1109.0581  [pdf] - 1579379
Pseudoscalar-photon Interactions, Axions, Non-Minimal Extensions, and Their Empirical Constraints from Observations
Comments: 8 pages
Submitted: 2011-09-02
Pseudoscalar-photon interactions were proposed in the study of the relations among equivalence principles. The interaction of pseudoscalar axion with gluons was proposed as a way to solve the strong CP problem. Subsequent proposal of axion as a dark matter candidate has been a focus of search. Motivation from superstring theories add to its importance. After a brief introduction and historical review, we present (i) the current status of our optical experiment using high-finesse Fabry-Perot resonant cavity - Q & A experiment - to detect pseudoscalar-photon interactions, (ii) the constraints on pseudoscalar-photon interactions from astrophysical and cosmological observations on cosmic polarization rotation, and (iii) theoretical models of non-minimal interactions of gravitational, electromagnetic and pseudoscalar (axion) fields, and their relevance to cosmology.
[3]  oai:arXiv.org:1001.4325  [pdf] - 172832
Axion Search with Q & A Experiment
Comments: 10 pages, 3 tables and 3 figures, presented in the International Workshop on Dark Matter, Dark Energy and Matter-Antimatter Asymmetry (Hsinchu, Taiwan, Nov. 20-21 2009); submitted to Modern Physics Letters. Rev. 2 is replaced for other collaborations' status/new-result corrections in Table 2, and 2 ref.s are added
Submitted: 2010-01-25, last modified: 2010-01-31
Dark matter is a focused issue in galactic evolution and cosmology. Axion is a viable particle candidate for dark matter. Its interaction with photon is an effective way to detect it, e.g., pseudoscalar-photon interaction will generate vacuum dichroism in a magnetic field. Motivated to measure the QED vacuum birefringence and to detect pseudoscalar-photon interaction, we started to build up the Q & A experiment (QED [Quantum Electrodynamics] and Axion experiment) in 1994. In this talk, we first give a brief historical account of planet hunting and dark matter evidence. We then review our 3.5 m Fabry-Perot interferometer together with our results of measuring vacuum dichroism and gaseous Cotton-Mouton effects. Our first results give (-0.2 $\pm$ 2.8) $\times$ 10$^{-13}$ rad/pass, at 2.3 T with 18,700 passes through a 0.6 m long magnet, for vacuum dichroism measurement. We are upgrading our interferometer to 7 m arm-length with a new 1.8 m 2.3 T permanent magnet capable of rotation up to 13 cycles per second. We aim at 10 nrad/Hz$^{1/2}$ optical sensitivity with 532 nm cavity finesse around 100,000. When achieved, vacuum dichroism would be measured to 8.6 $\times$ 10$^{-17}$ rad/pass in about 50 days, and QED birefringence would be measured to 28 %.
[4]  oai:arXiv.org:hep-ex/0611050  [pdf] - 113370
Q & A Experiment to Search for Vacuum Dichroism, Pseudoscalar-Photon Interaction and Millicharged Fermions
Comments: 21 pages, 13 figures, submitted to Modern Physics Letters
Submitted: 2006-11-28
A number of experiments are underway to detect vacuum birefringence and dichroism -- PVLAS, Q & A, and BMV. Recently, PVLAS experiment has observed optical rotation in vacuum by a magnetic field (vacuum dichroism). Theoretical interpretations of this result include a possible pseudoscalar-photon interaction and the existence of millicharged fermions. Here, we report the progress and first results of Q & A (QED [quantum electrodynamics] and Axion) experiment proposed and started in 1994. A 3.5-m high-finesse (around 30,000) Fabry-Perot prototype detector extendable to 7-m has been built and tested. We use X-pendulums and automatic control schemes developed by the gravitational-wave detection community for mirror suspension and cavity control. To polarize the vacuum, we use a 2.3-T dipole permanent magnet, with 27-mm-diameter clear borehole and 0.6-m field length,. In the experiment, the magnet is rotated at 5-10 rev/s to generate time-dependent polarization signal with twice the rotation frequency. Our ellipsometer/polarization-rotation-detection-system is formed by a pair of Glan-Taylor type polarizing prisms with extinction ratio lower than 10-8 together with a polarization modulating Faraday Cell with/without a quarter wave plate. We made an independent calibration of our apparatus by performing a measurement of gaseous Cotton-Mouton effect of nitrogen. We present our first experimental results and give a brief discussion of our experimental limit on pseudo-scalar-photon interaction and millicharged fermions.