Normalized to: McQuaide, M.
[1]
oai:arXiv.org:1906.09207 [pdf] - 1904239
Hybrid CMOS detectors for the Lynx x-ray surveyor high definition x-ray
imager
Submitted: 2019-06-21
X-ray hybrid CMOS detectors (HCDs) are a promising candidate for future x-ray
missions requiring high throughput and fine angular resolution along with large
field-of-view, such as the high-definition x-ray imager (HDXI) instrument on
the Lynx x-ray surveyor mission concept. These devices offer fast readout
capability, low power consumption, and radiation hardness while maintaining
high detection efficiency from 0.2 to 10 keV. In addition, x-ray hybrid CMOS
sensors may be fabricated with small pixel sizes to accommodate high-resolution
optics and have shown great improvements in recent years in noise and spectral
resolution performance. In particular, 12.5-{\mu}m pitch prototype devices that
include in-pixel correlated double sampling capability and crosstalk
eliminating capacitive transimpedance amplifiers, have been fabricated and
tested. These detectors have achieved read noise as low as 5.4 e-, and we
measure the best energy resolution to be 148 eV (2.5%) at 5.9 keV and 78 eV
(14.9%) at 0.53 keV. We will describe the characterization of these prototype
small-pixel x-ray HCDs, and we will discuss their applicability to the HDXI
instrument on Lynx.
[2]
oai:arXiv.org:1708.08956 [pdf] - 1765974
Recent X-ray hybrid CMOS detector developments and measurements
Submitted: 2017-08-29, last modified: 2018-10-12
The Penn State X-ray detector lab, in collaboration with Teledyne Imaging
Sensors (TIS), have progressed their efforts to improve soft X-ray Hybrid CMOS
detector (HCD) technology on multiple fronts. Having newly acquired a Teledyne
cryogenic SIDECAR ASIC for use with HxRG devices, measurements were performed
with an H2RG HCD and the cooled SIDECAR. We report new energy resolution and
read noise measurements, which show a significant improvement over room
temperature SIDECAR operation. Further, in order to meet the demands of future
high-throughput and high spatial resolution X-ray observatories, detectors with
fast readout and small pixel sizes are being developed. We report on
characteristics of new X-ray HCDs with 12.5 micron pitch that include in-pixel
CDS circuitry and crosstalk-eliminating CTIA amplifiers. In addition, PSU and
TIS are developing a new large-scale array Speedster-EXD device. The original
64 x 64 pixel Speedster-EXD prototype used comparators in each pixel to enable
event driven readout with order of magnitude higher effective readout rates,
which will now be implemented in a 550 x 550 pixel device. Finally, the
detector lab is involved in a sounding rocket mission that is slated to fly in
2018 with an off-plane reflection grating array and an H2RG X-ray HCD. We
report on the planned detector configuration for this mission, which will
increase the NASA technology readiness level of X-ray HCDs to TRL 9.