McMurray, R. E.

Normalized to: McMurray, R.

4 article(s) in total. 72 co-authors, from 1 to 2 common article(s). Median position in authors list is 7,5.

[1]  oai:arXiv.org:1909.04769  [pdf] - 2025793
Photometric precision of a Si:As impurity band conduction mid-infrared detector and application to transit spectroscopy
Comments: 16 pages, 10 figures and 2 tables, it has been accepted by PASP
Submitted: 2019-09-10
Transit spectroscopy is the most promising path toward characterizing nearby terrestrial planets at mid-infrared wavelengths in the next 20 years. The Spitzer Space telescope has achieved moderately good mid-infrared photometric precision in observations of transiting planets, but the intrinsic photometric stability of mid-IR detectors themselves has not been reported in the scientific or technical literature. Here, we evaluated the photometric precision of a JWST MIRI prototype mid-infrared Si:As impurity band conduction detector, using time-series data taken under flood illumination. These measurements of photometric precision were conducted over periods of 10 hours, representative of the time required to observe an exoplanet transit. After selecting multiple sub-regions with a size of 10x10 pixels and compensating for a gain change caused by our warm detector control electronics for the selected sub-regions, we found that the photometric precision was limited to 26.3ppm at high co-added signal levels due to a gain variation caused by our warm detector control electronics. The photometric precision was improved up to 12.8ppm after correcting for the gain drift. We also translated the photometric precision to the expected spectro-photometric precision, assuming that an optimized densified pupil spectrograph is used in transit observations. We found that the spectro-photometric precision of an optimized densified pupil spectrograph when used in transit observations is expected to be improved by the square root of the number of pixels per a spectral resolution element. At the high co-added signal levels, the total noise could be reduced down to 7ppm, which was larger by a factor of 1.3 than the ideal performance that was limited by the Poisson noise and readout noise. The systematic noise hidden behind the simulated transit spectroscopy was 1.7ppm.
[2]  oai:arXiv.org:1811.11313  [pdf] - 1791684
SOFIA - HIRMES: Looking forward to the HIgh-Resolution Mid-infrarEd Spectrometer
Comments: Accepted to the Journal of Astronomical Instrumentation (SOFIA Special Edition) on 11th November 2018
Submitted: 2018-11-27
The HIgh-Resolution Mid-infrarEd Spectrometer (HIRMES) is the 3rd Generation Instrument for the Stratospheric Observatory For Infrared Astronomy (SOFIA), currently in development at the NASA Goddard Space Flight Center (GSFC), and due for commissioning in 2019. By combining direct-detection Transition Edge Sensor (TES) bolometer arrays, grating-dispersive spectroscopy, and a host of Fabry-Perot tunable filters, HIRMES will provide the ability for High Resolution (R~100,000), Mid-Resolution (R~10,000), and Low-Resolution (R~600) slit-spectroscopy, and 2D Spectral Imaging (R~2000 at selected wavelengths) over the 25 - 122 {\mu}m mid-far infrared waveband. The driving science application is the evolution of proto-planetary systems via measurements of water-vapor, water-ice, deuterated hydrogen (HD), and neutral oxygen lines. However, HIRMES has been designed to be as flexible as possible to cover a wide range of science cases that fall within its phase-space, all whilst reaching sensitivities and observing powers not yet seen thus far on SOFIA, providing unique observing capabilities which will remain unmatched for decades.
[3]  oai:arXiv.org:1608.04323  [pdf] - 1456182
Proton irradiation results for long-wave HgCdTe infrared detector arrays for NEOCam
Comments: 9 figures, 32 pages
Submitted: 2016-08-15
HgCdTe detector arrays with a cutoff wavelength of ~10 ${\mu}$m intended for the NEOCam space mission were subjected to proton beam irradiation at the University of California Davis Crocker Nuclear Laboratory. Three arrays were tested - one with 800 $\mu$m substrate intact, one with 30 $\mu$m substrate, and one completely substrate-removed. The CdZnTe substrate, on which the HgCdTe detector is grown, has been shown to produce luminescence in shorter wave HgCdTe arrays that causes elevated signal in non-hit pixels when subjected to proton irradiation. This testing was conducted to ascertain whether or not full substrate removal is necessary. At the dark level of the dewar, we detect no luminescence in non-hit pixels during proton testing for both the substrate-removed detector array and the array with 30 ${\mu}$m substrate. The detector array with full 800 ${\mu}$m substrate exhibited substantial photocurrent for a flux of 103 protons/cm$^2$-s at a beam energy of 18.1 MeV (~ 750 e$^-$/s) and 34.4 MeV ($\sim$ 65 e$^-$/s). For the integrated space-like ambient proton flux level measured by the Spitzer Space Telescope, the luminescence would be well below the NEOCam dark current requirement of <200 e$^-$/s, but the pattern of luminescence could be problematic, possibly complicating calibration.
[4]  oai:arXiv.org:astro-ph/0008271  [pdf] - 37587
Validation of Up-the-Ramp Sampling with Cosmic Ray Rejection on IR Detectors
Comments: 30 pages, 13 figures. Accepted for publication in the PASP, 25 October 2000
Submitted: 2000-08-17, last modified: 2000-10-25
We examine cosmic ray rejection methodology on data collected from InSb and Si:As detectors. The application of an Up-the-Ramp sampling technique with cosmic ray identification and mitigation is the focus of this study. This technique is valuable for space-based observatories which are exposed to high-radiation environments. We validate the Up-the-Ramp approach on radiation-test data sets with InSb and Si:As detectors which were generated for SIRTF. The Up-the-Ramp sampling method studied in this paper is over 99.9% effective at removing cosmic rays and preserves the structure and photometric quality of the image to well within the measurement error.