sort results by

Use logical operators AND, OR, NOT and round brackets to construct complex queries. Whitespace-separated words are treated as ANDed.

Show articles per page in mode

McKinsey, D. N.

Normalized to: McKinsey, D.

68 article(s) in total. 1034 co-authors, from 1 to 37 common article(s). Median position in authors list is 24,0.

[1]  oai:arXiv.org:2003.11141  [pdf] - 2070172
An Effective Field Theory Analysis of the First LUX Dark Matter Search
Comments: 11 pages, 6 figures
Submitted: 2020-03-24
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
[2]  oai:arXiv.org:1907.06272  [pdf] - 2050176
Extending light WIMP searches to single scintillation photons in LUX
Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Baxter, A.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Boxer, B.; Brás, P.; Burdin, S.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fallon, S. R.; Fan, A.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Genovesi, J.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Grace, E.; Gwilliam, C.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Jacobsen, R. G.; Jahangir, O.; Ji, W.; Kamdin, K.; Kazka, K.; Khaitan, D.; Knoche, R.; Korolkova, E. V.; Kravitz, S.; Kudryavtsev, V. A.; Larsen, N. A.; Leason, E.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Levy, C.; Liao, J.; Lin, J.; Lindote, A.; Lopes, M. I.; López-Paredes, B.; Manalaysay, A.; Mannino, R. L.; Marangou, N.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Naylor, A.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; Nilima, A.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Reichhart, L.; Riffard, Q.; Rischbieter, G. R. C.; Rossiter, P.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, R.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Utku, U.; Uvarov, S.; Vacheret, A.; Velan, V.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Woodward, D.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
Comments:
Submitted: 2019-07-14, last modified: 2019-12-27
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
[3]  oai:arXiv.org:1802.06039  [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.; Akerlof, C. W.; Alsum, S. K.; Araújo, H. M.; Arthurs, M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Bauer, D.; Belle, J.; Beltrame, P.; Benson, T.; Bernard, E. P.; Biesiadzinski, T. P.; Boast, K. E.; Boxer, B.; Brás, P.; Buckley, J. H.; Bugaev, V. V.; Burdin, S.; Busenitz, J. K.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Chan, C.; Cherwinka, J. J.; Cole, A.; Cottle, A.; Craddock, W. W.; Currie, A.; Cutter, J. E.; Dahl, C. E.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edberg, T. K.; Edwards, W. R.; Fan, A.; Fayer, S.; Fiorucci, S.; Fruth, T.; Gaitskell, R. J.; Genovesi, J.; Ghag, C.; Gilchriese, M. G. D.; van der Grinten, M. G. D.; Hall, C. R.; Hans, S.; Hanzel, K.; Haselschwardt, S. J.; Hertel, S. A.; Hillbrand, S.; Hjemfelt, C.; Hoff, M. D.; Hor, J. Y-K.; Huang, D. Q.; Ignarra, C. M.; Ji, W.; Kaboth, A. C.; Kamdin, K.; Keefner, J.; Khaitan, D.; Khazov, A.; Kim, Y. D.; Kocher, C. D.; Korolkova, E. V.; Kraus, H.; Krebs, H. J.; Kreczko, L.; Krikler, B.; Kudryavtsev, V. A.; Kyre, S.; Lee, J.; Lenardo, B. G.; Leonard, D. S.; Lesko, K. T.; Levy, C.; Li, J.; Liao, J.; Liao, F. -T.; Lin, J.; Lindote, A.; Linehan, R.; Lippincott, W. H.; Liu, X.; Lopes, M. I.; Paredes, B. López; Lorenzon, W.; Luitz, S.; Lyle, J. M.; Majewski, P.; Manalaysay, A.; Mannino, R. L.; Maupin, C.; McKinsey, D. N.; Meng, Y.; Miller, E. H.; Mock, J.; Monzani, M. E.; Morad, J. A.; Morrison, E.; Mount, B. J.; Murphy, A. St. J.; Nelson, H. N.; Neves, F.; Nikoleyczik, J.; O'Sullivan, K.; Olcina, I.; Olevitch, M. A.; Oliver-Mallory, K. C.; Palladino, K. J.; Patton, S. J.; Pease, E. K.; Penning, B.; Piepke, A.; Powell, S.; Preece, R. M.; Pushkin, K.; Ratcliff, B. N.; Reichenbacher, J.; Rhyne, C. A.; Richards, A.; Rodrigues, J. P.; Rosero, R.; Rossiter, P.; Saba, J. S.; Sarychev, M.; Schnee, R. W.; Schubnell, M.; Scovell, P. R.; Shaw, S.; Shutt, T. A.; Silk, J. J.; Silva, C.; Skarpaas, K.; Skulski, W.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stancu, I.; Stark, M. R.; Stiegler, T. M.; Stifter, K.; Szydagis, M.; Taylor, W. C.; Taylor, R.; Taylor, D. J.; Temples, D.; Terman, P. A.; Thomas, K. J.; Timalsina, M.; To, W. H.; Tomás, A.; Tope, T. E.; Tripathi, M.; Tull, C. E.; Tvrznikova, L.; Utku, U.; Va'vra, J.; Vacheret, A.; Verbus, J. R.; Voirin, E.; Waldron, W. L.; Watson, J. R.; Webb, R. C.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Witherell, M. S.; Wolfs, F. L. H.; Woodward, D.; Worm, S. D.; Yeh, M.; Yin, J.; Young, I.
Comments: 14 pages, 11 figures
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with Weakly Interacting Massive Particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$ cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$ discovery potential is projected reaching cross sections below the existing and projected exclusion limits of similar experiments that are currently operating. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7 \times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
[4]  oai:arXiv.org:1910.09124  [pdf] - 1990394
The LUX-ZEPLIN (LZ) Experiment
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alquahtani, A.; Alsum, S. K.; Anderson, T. J.; Angelides, N.; Araújo, H. M.; Arbuckle, A.; Armstrong, J. E.; Arthurs, M.; Auyeung, H.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Bang, J.; Barry, M. J.; Barthel, J.; Bauer, D.; Bauer, P.; Baxter, A.; Belle, J.; Beltrame, P.; Bensinger, J.; Benson, T.; Bernard, E. P.; Bernstein, A.; Bhatti, A.; Biekert, A.; Biesiadzinski, T. P.; Birrittella, B.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Boxer, B.; Bramante, R.; Branson, S.; Brás, P.; Breidenbach, M.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Campbell, J. S.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Chott, N. I.; Cole, A.; Coleman, J.; Colling, D.; Conley, R. A.; Cottle, A.; Coughlen, R.; Craddock, W. W.; Curran, D.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dardin, S.; Dasu, S.; Davis, J.; Davison, T. J. R.; de Viveiros, L.; Decheine, N.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Dushkin, A.; Edberg, T. K.; Edwards, W. R.; Edwards, B. N.; Edwards, J.; Elnimr, M. M.; Emmet, W. T.; Eriksen, S. R.; Faham, C. H.; Fan, A.; Fayer, S.; Fiorucci, S.; Flaecher, H.; Florang, I. M. Fogarty; Ford, P.; Francis, V. B.; Froborg, F.; Fruth, T.; Gaitskell, R. J.; Gantos, N. J.; Garcia, D.; Geffre, A.; Gehman, V. M.; Gelfand, R.; Genovesi, J.; Gerhard, R. M.; Ghag, C.; Gibson, E.; Gilchriese, M. G. D.; Gokhale, S.; Gomber, B.; Gonda, T. G.; Greenall, A.; Greenwood, S.; Gregerson, G.; van der Grinten, M. G. D.; Gwilliam, C. B.; Hall, C. R.; Hamilton, D.; Hans, S.; Hanzel, K.; Harrington, T.; Harrison, A.; Hasselkus, C.; Haselschwardt, S. J.; Hemer, D.; Hertel, S. A.; Heise, J.; Hillbrand, S.; Hitchcock, O.; Hjemfelt, C.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Hor, J. Y-K.; Horn, M.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Irving, M. N.; Jacobsen, R. G.; Jahangir, O.; Jeffery, S. N.; Ji, W.; Johnson, M.; Johnson, J.; Johnson, P.; Jones, W. G.; Kaboth, A. C.; Kamaha, A.; Kamdin, K.; Kasey, V.; Kazkaz, K.; Keefner, J.; Khaitan, D.; Khaleeq, M.; Khazov, A.; Khromov, A. V.; Khurana, I.; Kim, Y. D.; Kim, W. T.; Kocher, C. D.; Konovalov, A. M.; Korley, L.; Korolkova, E. V.; Koyuncu, M.; Kras, J.; Kraus, H.; Kravitz, S. W.; Krebs, H. J.; Kreczko, L.; Krikler, B.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Lambert, A. R.; Landerud, B.; Larsen, N. A.; Laundrie, A.; Leason, E. A.; Lee, H. S.; Lee, J.; Lee, C.; Lenardo, B. G.; Leonard, D. S.; Leonard, R.; Lesko, K. T.; Levy, C.; Li, J.; Liu, Y.; Liao, J.; Liao, F. -T.; Lin, J.; Lindote, A.; Linehan, R.; Lippincott, W. H.; Liu, R.; Liu, X.; Loniewski, C.; Lopes, M. I.; Paredes, B. López; Lorenzon, W.; Lucero, D.; Luitz, S.; Lyle, J. M.; Lynch, C.; Majewski, P. A.; Makkinje, J.; Malling, D. C.; Manalaysay, A.; Manenti, L.; Mannino, R. L.; Marangou, N.; Markley, D. J.; MarrLaundrie, P.; Martin, T. J.; Marzioni, M. F.; Maupin, C.; McConnell, C. T.; McKinsey, D. N.; McLaughlin, J.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Minaker, Z. J.; Mizrachi, E.; Mock, J.; Molash, D.; Monte, A.; Monzani, M. E.; Morad, J. A.; Morrison, E.; Mount, B. J.; Murphy, A. St. J.; Naim, D.; Naylor, A.; Nedlik, C.; Nehrkorn, C.; Nelson, H. N.; Nesbit, J.; Neves, F.; Nikkel, J. A.; Nikoleyczik, J. A.; Nilima, A.; O'Dell, J.; Oh, H.; O'Neill, F. G.; O'Sullivan, K.; Olcina, I.; Olevitch, M. A.; Oliver-Mallory, K. C.; Oxborough, L.; Pagac, A.; Pagenkopf, D.; Pal, S.; Palladino, K. J.; Palmaccio, V. M.; Palmer, J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Penning, B. P.; Pereira, G.; Pereira, C.; Peterson, I. B.; Piepke, A.; Pierson, S.; Powell, S.; Preece, R. M.; Pushkin, K.; Qie, Y.; Racine, M.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C. A.; Richards, A.; Riffard, Q.; Rischbieter, G. R. C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Rossiter, P.; Rucinski, R.; Rutherford, G.; Rynders, D.; Saba, J. S.; Sabarots, L.; Santone, D.; Sarychev, M.; Sazzad, A. B. M. R.; Schnee, R. W.; Schubnell, M.; Scovell, P. R.; Severson, M.; Seymour, D.; Shaw, S.; Shutt, G. W.; Shutt, T. A.; Silk, J. J.; Silva, C.; Skarpaas, K.; Skulski, W.; Smith, A. R.; Smith, R. J.; Smith, R. E.; So, J.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stern, N.; Stevens, A.; Stiegler, T. M.; Stifter, K.; Studley, R.; Sumner, T. J.; Sundarnath, K.; Sutcliffe, P.; Swanson, N.; Szydagis, M.; Tan, M.; Taylor, W. C.; Taylor, R.; Taylor, D. J.; Temples, D.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; Timalsina, M.; To, W. H.; Tomás, A.; Tope, T. E.; Tripathi, M.; Tronstad, D. R.; Tull, C. E.; Turner, W.; Tvrznikova, L.; Utes, M.; Utku, U.; Uvarov, S.; Va'vra, J.; Vacheret, A.; Vaitkus, A.; Verbus, J. R.; Vietanen, T.; Voirin, E.; Vuosalo, C. O.; Walcott, S.; Waldron, W. L.; Walker, K.; Wang, J. J.; Wang, R.; Wang, L.; Wang, Y.; Watson, J. R.; Migneault, J.; Weatherly, S.; Webb, R. C.; Wei, W. -Z.; While, M.; White, R. G.; White, J. T.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Wilson, K.; Witherell, M. S.; Wolfs, F. L. H.; Wolfs, J. D.; Woodward, D.; Worm, S. D.; Xiang, X.; Xiao, Q.; Xu, J.; Yeh, M.; Yin, J.; Young, I.; Zhang, C.
Comments:
Submitted: 2019-10-20, last modified: 2019-11-03
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
[5]  oai:arXiv.org:1811.11241  [pdf] - 1981692
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Comments:
Submitted: 2018-11-27, last modified: 2019-10-16
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
[6]  oai:arXiv.org:1903.12372  [pdf] - 1916847
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Comments:
Submitted: 2019-03-29, last modified: 2019-06-07
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
[7]  oai:arXiv.org:1807.07113  [pdf] - 1758152
Search for annual and diurnal rate modulations in the LUX experiment
Comments: 12 pages, 9 figures
Submitted: 2018-07-18, last modified: 2018-09-27
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$\sigma$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
[8]  oai:arXiv.org:1803.10110  [pdf] - 1656542
Is DAMA Bathing in a Sea of Radioactive Argon?
Comments:
Submitted: 2018-03-27
A hypothesis is proposed to explain the long-standing DAMA/LIBRA puzzle. Introduced into the DAMA/LIBRA shielding is a purge gas of nominally high-purity nitrogen, which under this hypothesis contains argon impurities. Argon is introduced into the nitrogen purge gas either through leaks in the purge gas plumbing, or through commercially-supplied bottled nitrogen, diffuses through materials in the detector housings, and then comes in direct contact with the DAMA/LIBRA detectors. These argon impurities can then lead to a modulating 2.8 keV background under two scenarios. Scenario 1): These impurities include the isotope 37Ar, which decays by electron capture, emitting a 2.8 keV x-ray. These decays appear as single-site, monoenergetic events in DAMA/LIBRA, and produce an annual modulation due to the variation of neutron flux in the atmosphere and at the Earth's surface, which in turn leads to a seasonal variation in 37Ar production from the reactions $^{40}\textrm{Ca}(\textrm{n,}\alpha)^{37}\textrm{Ar}$ and $^{36}\textrm{Ar}(\textrm{n,}\gamma)^{37}\textrm{Ar}$. Scenario 2): Radon is also in the DAMA/LIBRA purge gas, modulating seasonally at a rate below the current DAMA/LIBRA limits. When radon or its short-lived daughters decay, the resulting beta, gamma, and bremsstrahlung radiation cause stable 40Ar to be ionized within the copper housings surrounding the NaI(Tl) detectors, resulting in characteristic 2.8 keV x-rays. Modulating backgrounds might also result from radon-induced neutron or gamma-ray flux from the surrounding cavern, leading to a small modulating background enhanced at low energy by the presence of 40Ar within the copper housings. These two scenarios are straightforward to test through assay of the purge gas as well as Monte Carlo and laboratory study of the DAMA/LIBRA copper housings when excited by ionizing radiation.
[9]  oai:arXiv.org:1709.00800  [pdf] - 1611913
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Comments: 10 pages, 10 figures, 2 tables
Submitted: 2017-09-03
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
[10]  oai:arXiv.org:1707.04591  [pdf] - 1585955
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Battaglieri, Marco; Belloni, Alberto; Chou, Aaron; Cushman, Priscilla; Echenard, Bertrand; Essig, Rouven; Estrada, Juan; Feng, Jonathan L.; Flaugher, Brenna; Fox, Patrick J.; Graham, Peter; Hall, Carter; Harnik, Roni; Hewett, JoAnne; Incandela, Joseph; Izaguirre, Eder; McKinsey, Daniel; Pyle, Matthew; Roe, Natalie; Rybka, Gray; Sikivie, Pierre; Tait, Tim M. P.; Toro, Natalia; Van De Water, Richard; Weiner, Neal; Zurek, Kathryn; Adelberger, Eric; Afanasev, Andrei; Alexander, Derbin; Alexander, James; Antochi, Vasile Cristian; Asner, David Mark; Baer, Howard; Banerjee, Dipanwita; Baracchini, Elisabetta; Barbeau, Phillip; Barrow, Joshua; Bastidon, Noemie; Battat, James; Benson, Stephen; Berlin, Asher; Bird, Mark; Blinov, Nikita; Boddy, Kimberly K.; Bondi, Mariangela; Bonivento, Walter M.; Boulay, Mark; Boyce, James; Brodeur, Maxime; Broussard, Leah; Budnik, Ranny; Bunting, Philip; Caffee, Marc; Caiazza, Sabato Stefano; Campbell, Sheldon; Cao, Tongtong; Carosi, Gianpaolo; Carpinelli, Massimo; Cavoto, Gianluca; Celentano, Andrea; Chang, Jae Hyeok; Chattopadhyay, Swapan; Chavarria, Alvaro; Chen, Chien-Yi; Clark, Kenneth; Clarke, John; Colegrove, Owen; Coleman, Jonathon; Cooke, David; Cooper, Robert; Crisler, Michael; Crivelli, Paolo; D'Eramo, Francesco; D'Urso, Domenico; Dahl, Eric; Dawson, William; De Napoli, Marzio; De Vita, Raffaella; DeNiverville, Patrick; Derenzo, Stephen; Di Crescenzo, Antonia; Di Marco, Emanuele; Dienes, Keith R.; Diwan, Milind; Dongwi, Dongwi Handiipondola; Drlica-Wagner, Alex; Ellis, Sebastian; Ezeribe, Anthony Chigbo; Farrar, Glennys; Ferrer, Francesc; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fiorillo, Giuliana; Fornal, Bartosz; Freyberger, Arne; Frugiuele, Claudia; Galbiati, Cristian; Galon, Iftah; Gardner, Susan; Geraci, Andrew; Gerbier, Gilles; Graham, Mathew; Gschwendtner, Edda; Hearty, Christopher; Heise, Jaret; Henning, Reyco; Hill, Richard J.; Hitlin, David; Hochberg, Yonit; Hogan, Jason; Holtrop, Maurik; Hong, Ziqing; Hossbach, Todd; Humensky, T. B.; Ilten, Philip; Irwin, Kent; Jaros, John; Johnson, Robert; Jones, Matthew; Kahn, Yonatan; Kalantarians, Narbe; Kaplinghat, Manoj; Khatiwada, Rakshya; Knapen, Simon; Kohl, Michael; Kouvaris, Chris; Kozaczuk, Jonathan; Krnjaic, Gordan; Kubarovsky, Valery; Kuflik, Eric; Kusenko, Alexander; Lang, Rafael; Leach, Kyle; Lin, Tongyan; Lisanti, Mariangela; Liu, Jing; Liu, Kun; Liu, Ming; Loomba, Dinesh; Lykken, Joseph; Mack, Katherine; Mans, Jeremiah; Maris, Humphrey; Markiewicz, Thomas; Marsicano, Luca; Martoff, C. J.; Mazzitelli, Giovanni; McCabe, Christopher; McDermott, Samuel D.; McDonald, Art; McKinnon, Bryan; Mei, Dongming; Melia, Tom; Miller, Gerald A.; Miuchi, Kentaro; Nazeer, Sahara Mohammed Prem; Moreno, Omar; Morozov, Vasiliy; Mouton, Frederic; Mueller, Holger; Murphy, Alexander; Neilson, Russell; Nelson, Tim; Neu, Christopher; Nosochkov, Yuri; O'Hare, Ciaran; Oblath, Noah; Orrell, John; Ouellet, Jonathan; Pastore, Saori; Paul, Sebouh; Perelstein, Maxim; Peter, Annika; Phan, Nguyen; Phinney, Nan; Pivovaroff, Michael; Pocar, Andrea; Pospelov, Maxim; Pradler, Josef; Privitera, Paolo; Profumo, Stefano; Raggi, Mauro; Rajendran, Surjeet; Randazzo, Nunzio; Raubenheimer, Tor; Regenfus, Christian; Renshaw, Andrew; Ritz, Adam; Rizzo, Thomas; Rosenberg, Leslie; Rubbia, Andre; Rybolt, Ben; Saab, Tarek; Safdi, Benjamin R.; Santopinto, Elena; Scarff, Andrew; Schneider, Michael; Schuster, Philip; Seidel, George; Sekiya, Hiroyuki; Seong, Ilsoo; Simi, Gabriele; Sipala, Valeria; Slatyer, Tracy; Slone, Oren; Smith, Peter F; Smolinsky, Jordan; Snowden-Ifft, Daniel; Solt, Matthew; Sonnenschein, Andrew; Sorensen, Peter; Spooner, Neil; Srivastava, Brijesh; Stancu, Ion; Strigari, Louis; Strube, Jan; Sushkov, Alexander O.; Szydagis, Matthew; Tanedo, Philip; Tanner, David; Tayloe, Rex; Terrano, William; Thaler, Jesse; Thomas, Brooks; Thorpe, Brianna; Thorpe, Thomas; Tiffenberg, Javier; Tran, Nhan; Trovato, Marco; Tully, Christopher; Tyson, Tony; Vachaspati, Tanmay; Vahsen, Sven; van Bibber, Karl; Vandenbroucke, Justin; Villano, Anthony; Volansky, Tomer; Wang, Guojian; Ward, Thomas; Wester, William; Whitbeck, Andrew; Williams, David A.; Wing, Matthew; Winslow, Lindley; Wojtsekhowski, Bogdan; Yu, Hai-Bo; Yu, Shin-Shan; Yu, Tien-Tien; Zhang, Xilin; Zhao, Yue; Zhong, Yi-Ming
Comments: 102 pages + references
Submitted: 2017-07-14
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
[11]  oai:arXiv.org:1704.02297  [pdf] - 1582421
First Searches for Axions and Axion-Like Particles with the LUX Experiment
Comments:
Submitted: 2017-04-07, last modified: 2017-06-30
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90% C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are excluded. For galactic axion-like particles, values of gAe larger than 4.2 $\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16 keV/c$^{2}$. These are the most stringent constraints to date for these interactions.
[12]  oai:arXiv.org:1705.03380  [pdf] - 1583256
Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
Comments: 7 pages, 3 figures, version accepted by PRL
Submitted: 2017-05-09, last modified: 2017-06-23
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ = 5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
[13]  oai:arXiv.org:1703.09144  [pdf] - 1554108
LUX-ZEPLIN (LZ) Technical Design Report
Mount, B. J.; Hans, S.; Rosero, R.; Yeh, M.; Chan, C.; Gaitskell, R. J.; Huang, D. Q.; Makkinje, J.; Malling, D. C.; Pangilinan, M.; Rhyne, C. A.; Taylor, W. C.; Verbus, J. R.; Kim, Y. D.; Lee, H. S.; Lee, J.; Leonard, D. S.; Li, J.; Belle, J.; Cottle, A.; Lippincott, W. H.; Markley, D. J.; Martin, T. J.; Sarychev, M.; Tope, T. E.; Utes, M.; Wang, R.; Young, I.; Araújo, H. M.; Bailey, A. J.; Bauer, D.; Colling, D.; Currie, A.; Fayer, S.; Froborg, F.; Greenwood, S.; Jones, W. G.; Kasey, V.; Khaleeq, M.; Olcina, I.; Paredes, B. López; Richards, A.; Sumner, T. J.; Tomás, A.; Vacheret, A.; Brás, P.; Lindote, A.; Lopes, M. I.; Neves, F.; Rodrigues, J. P.; Silva, C.; Solovov, V. N.; Barry, M. J.; Cole, A.; Dobi, A.; Edwards, W. R.; Faham, C. H.; Fiorucci, S.; Gantos, N. J.; Gehman, V. M.; Gilchriese, M. G. D.; Hanzel, K.; Hoff, M. D.; Kamdin, K.; Lesko, K. T.; McConnell, C. T.; O'Sullivan, K.; Oliver-Mallory, K. C.; Patton, S. J.; Saba, J. S.; Sorensen, P.; Thomas, K. J.; Tull, C. E.; Waldron, W. L.; Witherell, M. S.; Bernstein, A.; Kazkaz, K.; Xu, J.; Akimov, D. Yu.; Bolozdynya, A. I.; Khromov, A. V.; Konovalov, A. M.; Kumpan, A. V.; Sosnovtsev, V. V.; Dahl, C. E.; Temples, D.; Carmona-Benitez, M. C.; de Viveiros, L.; Akerib, D. S.; Auyeung, H.; Biesiadzinski, T. P.; Breidenbach, M.; Bramante, R.; Conley, R.; Craddock, W. W.; Fan, A.; Hau, A.; Ignarra, C. M.; Ji, W.; Krebs, H. J.; Linehan, R.; Lee, C.; Luitz, S.; Mizrachi, E.; Monzani, M. E.; O'Neill, F. G.; Pierson, S.; Racine, M.; Ratcliff, B. N.; Shutt, G. W.; Shutt, T. A.; Skarpaas, K.; Stifter, K.; To, W. H.; Va'vra, J.; Whitis, T. J.; Wisniewski, W. J.; Bai, X.; Bunker, R.; Coughlen, R.; Hjemfelt, C.; Leonard, R.; Miller, E. H.; Morrison, E.; Reichenbacher, J.; Schnee, R. W.; Stark, M. R.; Sundarnath, K.; Tiedt, D. R.; Timalsina, M.; Bauer, P.; Carlson, B.; Horn, M.; Johnson, M.; Keefner, J.; Maupin, C.; Taylor, D. J.; Balashov, S.; Ford, P.; Francis, V.; Holtom, E.; Khazov, A.; Kaboth, A.; Majewski, P.; Nikkel, J. A.; O'Dell, J.; Preece, R. M.; van der Grinten, M. G. D.; Worm, S. D.; Mannino, R. L.; Stiegler, T. M.; Terman, P. A.; Webb, R. C.; Levy, C.; Mock, J.; Szydagis, M.; Busenitz, J. K.; Elnimr, M.; Hor, J. Y-K.; Meng, Y.; Piepke, A.; Stancu, I.; Kreczko, L.; Krikler, B.; Penning, B.; Bernard, E. P.; Jacobsen, R. G.; McKinsey, D. N.; Watson, R.; Cutter, J. E.; El-Jurf, S.; Gerhard, R. M.; Hemer, D.; Hillbrand, S.; Holbrook, B.; Lenardo, B. G.; Manalaysay, A. G.; Morad, J. A.; Stephenson, S.; Thomson, J. A.; Tripathi, M.; Uvarov, S.; Haselschwardt, S. J.; Kyre, S.; Nehrkorn, C.; Nelson, H. N.; Solmaz, M.; White, D. T.; Cascella, M.; Dobson, J. E. Y.; Ghag, C.; Liu, X.; Manenti, L.; Reichhart, L.; Shaw, S.; Utku, U.; Beltrame, P.; Davison, T. J. R.; Marzioni, M. F.; Murphy, A. St. J.; Nilima, A.; Boxer, B.; Burdin, S.; Greenall, A.; Powell, S.; Rose, H. J.; Sutcliffe, P.; Balajthy, J.; Edberg, T. K.; Hall, C. R.; Silk, J. S.; Hertel, S.; Akerlof, C. W.; Arthurs, M.; Lorenzon, W.; Pushkin, K.; Schubnell, M.; Boast, K. E.; Carels, C.; Fruth, T.; Kraus, H.; Liao, F. -T.; Lin, J.; Scovell, P. R.; Druszkiewicz, E.; Khaitan, D.; Koyuncu, M.; Skulski, W.; Wolfs, F. L. H.; Yin, J.; Korolkova, E. V.; Kudryavtsev, V. A.; Rossiter, P.; Woodward, D.; Chiller, A. A.; Chiller, C.; Mei, D. -M.; Wang, L.; Wei, W. -Z.; While, M.; Zhang, C.; Alsum, S. K.; Benson, T.; Carlsmith, D. L.; Cherwinka, J. J.; Dasu, S.; Gregerson, G.; Gomber, B.; Pagac, A.; Palladino, K. J.; Vuosalo, C. O.; Xiao, Q.; Buckley, J. H.; Bugaev, V. V.; Olevitch, M. A.; Boulton, E. M.; Emmet, W. T.; Hurteau, T. W.; Larsen, N. A.; Pease, E. K.; Tennyson, B. P.; Tvrznikova, L.
Comments: 392 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Numbers Two and Three (CD-2 and CD-3) management processes. Report also available by chapter at <a href="http://hep.ucsb.edu/LZ/TDR/">this URL</a>
Submitted: 2017-03-27
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
[14]  oai:arXiv.org:1608.07648  [pdf] - 1531370
Results from a search for dark matter in the complete LUX exposure
Comments: This version includes a combined analysis with previously published LUX results, and matches the version published in PRL
Submitted: 2016-08-26, last modified: 2017-01-13
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
[15]  oai:arXiv.org:1608.05381  [pdf] - 1503451
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration; Akerib, D. S.; Alsum, S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bradley, A.; Bramante, R.; Brás, P.; Byram, D.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chapman, J. J.; Chiller, A. A.; Chiller, C.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Malling, D. C.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Pease, E. K.; Phelps, P.; Reichhart, L.; Rhyne, C. A.; Shaw, S.; Shutt, T. A.; Silva, C.; Solmaz, M.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W. C.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Xu, J.; Yazdani, K.; Young, S. K.; Zhang, C.
Comments: 24 pages, 15 figures, 6 tables
Submitted: 2016-08-18, last modified: 2016-10-26
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
[16]  oai:arXiv.org:0904.2930  [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
Comments: Accepted for publication in Astroparticle Physics
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure scintillation pulse shapes of electron and nuclear recoil events and to demonstrate the feasibility of pulse-shape discrimination (PSD) down to an electron-equivalent energy of 20 keV. In the surface dataset using a triple-coincidence tag we found the fraction of beta events that are misidentified as nuclear recoils to be $<1.4\times 10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil acceptance of at least 90%, with 4% systematic uncertainty on the absolute energy scale. The discrimination measurement on surface was limited by nuclear recoils induced by cosmic-ray generated neutrons. This was improved by moving the detector to the SNOLAB underground laboratory, where the reduced background rate allowed the same measurement with only a double-coincidence tag. The combined data set contains $1.23\times10^8$ events. One of those, in the underground data set, is in the nuclear-recoil region of interest. Taking into account the expected background of 0.48 events coming from random pileup, the resulting upper limit on the electronic recoil contamination is $<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil acceptance of at least 90%, with 6% systematic uncertainty on the absolute energy scale. We developed a general mathematical framework to describe PSD parameter distributions and used it to build an analytical model of the distributions observed in DEAP-1. Using this model, we project a misidentification fraction of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for a detector with 8 PE/keVee light yield. This reduction enables a search for spin-independent scattering of WIMPs from 1000 kg of liquid argon with a WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming negligible contribution from nuclear recoil backgrounds.
[17]  oai:arXiv.org:1608.08632  [pdf] - 1472452
Dark Sectors 2016 Workshop: Community Report
Alexander, Jim; Battaglieri, Marco; Echenard, Bertrand; Essig, Rouven; Graham, Matthew; Izaguirre, Eder; Jaros, John; Krnjaic, Gordan; Mardon, Jeremy; Morrissey, David; Nelson, Tim; Perelstein, Maxim; Pyle, Matt; Ritz, Adam; Schuster, Philip; Shuve, Brian; Toro, Natalia; Van De Water, Richard G; Akerib, Daniel; An, Haipeng; Aniol, Konrad; Arnquist, Isaac J.; Asner, David M.; Back, Henning O.; Baker, Keith; Baltzell, Nathan; Banerjee, Dipanwita; Batell, Brian; Bauer, Daniel; Beacham, James; Benesch, Jay; Bjorken, James; Blinov, Nikita; Boehm, Celine; Bondí, Mariangela; Bonivento, Walter; Bossi, Fabio; Brodsky, Stanley J.; Budnik, Ran; Bueltmann, Stephen; Bukhari, Masroor H.; Bunker, Raymond; Carpinelli, Massimo; Cartaro, Concetta; Cassel, David; Cavoto, Gianluca; Celentano, Andrea; Chaterjee, Animesh; Chaudhuri, Saptarshi; Chiodini, Gabriele; Cho, Hsiao-Mei Sherry; Church, Eric D.; Cooke, D. A.; Cooley, Jodi; Cooper, Robert; Corliss, Ross; Crivelli, Paolo; Curciarello, Francesca; D'Angelo, Annalisa; Davoudiasl, Hooman; De Napoli, Marzio; De Vita, Raffaella; Denig, Achim; deNiverville, Patrick; Deshpande, Abhay; Dharmapalan, Ranjan; Dobrescu, Bogdan; Donskov, Sergey; Dupre, Raphael; Estrada, Juan; Fegan, Stuart; Ferber, Torben; Field, Clive; Figueroa-Feliciano, Enectali; Filippi, Alessandra; Fornal, Bartosz; Freyberger, Arne; Friedland, Alexander; Galon, Iftach; Gardner, Susan; Girod, Francois-Xavier; Gninenko, Sergei; Golutvin, Andrey; Gori, Stefania; Grab, Christoph; Graziani, Enrico; Griffioen, Keith; Haas, Andrew; Harigaya, Keisuke; Hearty, Christopher; Hertel, Scott; Hewett, JoAnne; Hime, Andrew; Hitlin, David; Hochberg, Yonit; Holt, Roy J.; Holtrop, Maurik; Hoppe, Eric W.; Hossbach, Todd W.; Hsu, Lauren; Ilten, Phil; Incandela, Joe; Inguglia, Gianluca; Irwin, Kent; Jaegle, Igal; Johnson, Robert P.; Kahn, Yonatan; Kalicy, Grzegorz; Kang, Zhong-Bo; Khachatryan, Vardan; Kozhuharov, Venelin; Krasnikov, N. V.; Kubarovsky, Valery; Kuflik, Eric; Kurinsky, Noah; Laha, Ranjan; Lanfranchi, Gaia; Li, Dale; Lin, Tongyan; Lisanti, Mariangela; Liu, Kun; Liu, Ming; Loer, Ben; Loomba, Dinesh; Lyubovitskij, Valery E.; Manalaysay, Aaron; Mandaglio, Giuseppe; Mans, Jeremiah; Marciano, W. J.; Markiewicz, Thomas; Marsicano, Luca; Maruyama, Takashi; Matveev, Victor A.; McKeen, David; McKinnon, Bryan; McKinsey, Dan; Merkel, Harald; Mock, Jeremy; Monzani, Maria Elena; Moreno, Omar; Nantais, Corina; Paul, Sebouh; Peskin, Michael; Poliakov, Vladimir; Polosa, Antonio D; Pospelov, Maxim; Rachek, Igor; Radics, Balint; Raggi, Mauro; Randazzo, Nunzio; Ratcliff, Blair; Rizzo, Alessandro; Rizzo, Thomas; Robinson, Alan; Rubbia, Andre; Rubin, David; Rueter, Dylan; Saab, Tarek; Santopinto, Elena; Schnee, Richard; Shelton, Jessie; Simi, Gabriele; Simonyan, Ani; Sipala, Valeria; Slone, Oren; Smith, Elton; Snowden-Ifft, Daniel; Solt, Matthew; Sorensen, Peter; Soreq, Yotam; Spagnolo, Stefania; Spencer, James; Stepanyan, Stepan; Strube, Jan; Sullivan, Michael; Tadepalli, Arun S.; Tait, Tim; Taiuti, Mauro; Tanedo, Philip; Tayloe, Rex; Thaler, Jesse; Tran, Nhan V.; Tulin, Sean; Tully, Christopher G.; Uemura, Sho; Ungaro, Maurizio; Valente, Paolo; Vance, Holly; Vavra, Jerry; Volansky, Tomer; von Krosigk, Belina; Whitbeck, Andrew; Williams, Mike; Wittich, Peter; Wojtsekhowski, Bogdan; Xue, Wei; Yoon, Jong Min; Yu, Hai-Bo; Yu, Jaehoon; Yu, Tien-Tien; Zhang, Yue; Zhao, Yue; Zhong, Yiming; Zurek, Kathryn
Comments: 66 pages, 15 figures, 3 tables. Workshop website and agenda: http://www-conf.slac.stanford.edu/darksectors2016/ https://indico.cern.ch/event/507783/ Editors: J. Alexander, M. Battaglieri, B. Echenard, R. Essig, M. Graham, E. Izaguirre, J. Jaros, G. Krnjaic, J. Mardon, D. Morrissey, T. Nelson, M. Perelstein, M. Pyle, A. Ritz, P. Schuster, B. Shuve, N. Toro, R. Van De Water
Submitted: 2016-08-30
This report, based on the Dark Sectors workshop at SLAC in April 2016, summarizes the scientific importance of searches for dark sector dark matter and forces at masses beneath the weak-scale, the status of this broad international field, the important milestones motivating future exploration, and promising experimental opportunities to reach these milestones over the next 5-10 years.
[18]  oai:arXiv.org:1512.03506  [pdf] - 1406496
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Comments: Accepted by Phys. Rev. Lett
Submitted: 2015-12-10, last modified: 2016-05-16
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $\beta$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
[19]  oai:arXiv.org:1512.03133  [pdf] - 1402511
Tritium calibration of the LUX dark matter experiment
Comments:
Submitted: 2015-12-09, last modified: 2016-05-05
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
[20]  oai:arXiv.org:1509.02910  [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration; Akerib, D. S.; Akerlof, C. W.; Akimov, D. Yu.; Alsum, S. K.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Balashov, S.; Barry, M. J.; Bauer, P.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boast, K. E.; Bolozdynya, A. I.; Boulton, E. M.; Bramante, R.; Buckley, J. H.; Bugaev, V. V.; Bunker, R.; Burdin, S.; Busenitz, J. K.; Carels, C.; Carlsmith, D. L.; Carlson, B.; Carmona-Benitez, M. C.; Cascella, M.; Chan, C.; Cherwinka, J. J.; Chiller, A. A.; Chiller, C.; Craddock, W. W.; Currie, A.; Cutter, J. E.; da Cunha, J. P.; Dahl, C. E.; Dasu, S.; Davison, T. J. R.; de Viveiros, L.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edberg, T. K.; Edwards, B. N.; Edwards, W. R.; Elnimr, M. M.; Emmet, W. T.; Faham, C. H.; Fiorucci, S.; Ford, P.; Francis, V. B.; Fu, C.; Gaitskell, R. J.; Gantos, N. J.; Gehman, V. M.; Gerhard, R. M.; Ghag, C.; Gilchriese, M. G. D.; Gomber, B.; Hall, C. R.; Harris, A.; Haselschwardt, S. J.; Hertel, S. A.; Hoff, M. D.; Holbrook, B.; Holtom, E.; Huang, D. Q.; Hurteau, T. W.; Ignarra, C. M.; Jacobsen, R. G.; Ji, W.; Ji, X.; Johnson, M.; Ju, Y.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Khazov, A.; Khromov, A. V.; Konovalov, A. M.; Korolkova, E. V.; Kraus, H.; Krebs, H. J.; Kudryavtsev, V. A.; Kumpan, A. V.; Kyre, S.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Liao, F. -T.; Lin, J.; Lindote, A.; Lippincott, W. H.; Liu, J.; Liu, X.; Lopes, M. I.; Lorenzon, W.; Luitz, S.; Majewski, P.; Malling, D. C.; Manalaysay, A. G.; Manenti, L.; Mannino, R. L.; Markley, D. J.; Martin, T. J.; Marzioni, M. F.; McKinsey, D. N.; Mei, D. -M.; Meng, Y.; Miller, E. H.; Mock, J.; Monzani, M. E.; Morad, J. A.; Murphy, A. St. J.; Nelson, H. N.; Neves, F.; Nikkel, J. A.; O'Neill, F. G.; O'Dell, J.; O'Sullivan, K.; Olevitch, M. A.; Oliver-Mallory, K. C.; Palladino, K. J.; Pangilinan, M.; Patton, S. J.; Pease, E. K.; Piepke, A.; Powell, S.; Preece, R. M.; Pushkin, K.; Ratcliff, B. N.; Reichenbacher, J.; Reichhart, L.; Rhyne, C.; Rodrigues, J. P.; Rose, H. J.; Rosero, R.; Saba, J. S.; Sarychev, M.; Schnee, R. W.; Schubnell, M. S. G.; Scovell, P. R.; Shaw, S.; Shutt, T. A.; Silva, C.; Skarpaas, K.; Skulski, W.; Solovov, V. N.; Sorensen, P.; Sosnovtsev, V. V.; Stancu, I.; Stark, M. R.; Stephenson, S.; Stiegler, T. M.; Sumner, T. J.; Sundarnath, K.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Thomas, K. J.; Thomson, J. A.; Tiedt, D. R.; To, W. H.; Tomás, A.; Tripathi, M.; Tull, C. E.; Tvrznikova, L.; Uvarov, S.; Va'vra, J.; van der Grinten, M. G. D.; Verbus, J. R.; Vuosalo, C. O.; Waldron, W. L.; Wang, L.; Webb, R. C.; Wei, W. -Z.; While, M.; White, D. T.; Whitis, T. J.; Wisniewski, W. J.; Witherell, M. S.; Wolfs, F. L. H.; Woods, E.; Woodward, D.; Worm, S. D.; Yeh, M.; Yin, J.; Young, S. K.; Zhang, C.
Comments: 278 pages. Submitted to the Department of Energy as part of the documentation for the Critical Decision Number One (CD-1) management process. Report also available by chapter at http://hep.ucsb.edu/LZ/CDR. This version includes corrections of minor typographic errors
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
[21]  oai:arXiv.org:1305.1605  [pdf] - 1241296
Dark Matter in the Coming Decade: Complementary Paths to Discovery and Beyond
Comments: Report prepared for the Community Summer Study (Snowmass) 2013, on behalf of Cosmic Frontier Working Groups 1-4 (CF1: WIMP Dark Matter Direct Detection, CF2: WIMP Dark Matter Indirect Detection, CF3: Non-WIMP Dark Matter, and CF4: Dark Matter Complementarity); published version
Submitted: 2013-05-07, last modified: 2015-07-03
In this report we summarize the many dark matter searches currently being pursued through four complementary approaches: direct detection, indirect detection, collider experiments, and astrophysical probes. The essential features of broad classes of experiments are described, each with their own strengths and weaknesses. The complementarity of the different dark matter searches is discussed qualitatively and illustrated quantitatively in two simple theoretical frameworks. Our primary conclusion is that the diversity of possible dark matter candidates requires a balanced program drawing from all four approaches.
[22]  oai:arXiv.org:1408.1914  [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Comments: 16 pages, 16 figures
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
[23]  oai:arXiv.org:1211.0909  [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Comments:
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was operated underground at SNOLAB in order to test the techniques and measure the backgrounds inherent to single phase detection, in support of the \mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled through material selection, construction techniques, pulse shape discrimination and event reconstruction. This report details the analysis of background events observed in three iterations of the DEAP-1 detector, and the measures taken to reduce them. The $^{222}$Rn decay rate in the liquid argon was measured to be between 16 and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background spectrum near the region of interest for Dark Matter detection in the DEAP-1 detector can be described considering events from three sources: radon daughters decaying on the surface of the active volume, the expected rate of electromagnetic events misidentified as nuclear recoils due to inefficiencies in the pulse shape discrimination, and leakage of events from outside the fiducial volume due to imperfect position reconstruction. These backgrounds statistically account for all observed events, and they will be strongly reduced in the DEAP-3600 detector due to its higher light yield and simpler geometry.
[24]  oai:arXiv.org:1403.4842  [pdf] - 799232
Update on the MiniCLEAN Dark Matter Experiment
Comments: To appear in the Proceedings of the TAUP 2013 Conference (F. Avignone & W. Haxton, editors, Physics Procedia, Elsevier)
Submitted: 2014-03-19
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
[25]  oai:arXiv.org:1403.1299  [pdf] - 862558
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Comments: 18 pages, 12 figures / 17 images, submitted to Astropart. Phys
Submitted: 2014-03-05
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
[26]  oai:arXiv.org:1402.3731  [pdf] - 788195
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Comments: 16 pages, 3 figures, to appear in the proceedings of The 10th International Symposium on Cosmology and Particle Astrophysics (CosPA2013); fixed author list and added info on new calibration
Submitted: 2014-02-15, last modified: 2014-02-25
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
[27]  oai:arXiv.org:1310.8214  [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Comments: Accepted by Phys. Rev. Lett. Appendix A included as supplementary material with PRL article
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
[28]  oai:arXiv.org:1401.6085  [pdf] - 776010
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 4: Cosmic Frontier
Comments: 61 pages
Submitted: 2014-01-23
These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 4, on the Cosmic Frontier, discusses the program of research relevant to cosmology and the early universe. This area includes the study of dark matter and the search for its particle nature, the study of dark energy and inflation, and cosmic probes of fundamental symmetries.
[29]  oai:arXiv.org:1310.8327  [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Comments: Snowmass CF1 Final Summary Report: 47 pages and 28 figures with a 5 page appendix on instrumentation R&D
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader Particle Physics community to produce this document. The charge to CF1 was (a) to summarize the current status and projected sensitivity of WIMP direct detection experiments worldwide, (b) motivate WIMP dark matter searches over a broad parameter space by examining a spectrum of WIMP models, (c) establish a community consensus on the type of experimental program required to explore that parameter space, and (d) identify the common infrastructure required to practically meet those goals.
[30]  oai:arXiv.org:1310.8621  [pdf] - 740578
Dark Matter in the Coming Decade: Complementary Paths to Discovery and Beyond
Comments: Snowmass 2013 CF4 Working Group Report
Submitted: 2013-10-31
In this Report we discuss the four complementary searches for the identity of dark matter: direct detection experiments that look for dark matter interacting in the lab, indirect detection experiments that connect lab signals to dark matter in our own and other galaxies, collider experiments that elucidate the particle properties of dark matter, and astrophysical probes sensitive to non-gravitational interactions of dark matter. The complementarity among the different dark matter searches is discussed qualitatively and illustrated quantitatively in several theoretical scenarios. Our primary conclusion is that the diversity of possible dark matter candidates requires a balanced program based on all four of those approaches.
[31]  oai:arXiv.org:1205.2272  [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Comments: v2 updated to include content after reviewer comments (Sep 2012)
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
[32]  oai:arXiv.org:1104.3088  [pdf] - 661239
A search for light dark matter in XENON10 data
Comments: Manuscript identical to v2 (published version) but also contains erratum. Note v3==v2 but without \linenumbers
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
[33]  oai:arXiv.org:1210.4569  [pdf] - 630139
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Comments:
Submitted: 2012-10-16, last modified: 2013-02-22
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
[34]  oai:arXiv.org:1302.0534  [pdf] - 1159464
A Concept for A Dark Matter Detector Using Liquid Helium-4
Comments: 18 pages, 18 figures; To be submitted to Phys. Rev. D
Submitted: 2013-02-03, last modified: 2013-02-19
Direct searches for light dark matter particles (mass $<10$ GeV) are especially challenging because of the low energies transferred in elastic scattering to typical heavy nuclear targets. We investigate the possibility of using liquid Helium-4 as a target material, taking advantage of the favorable kinematic matching of the Helium nucleus to light dark matter particles. Monte Carlo simulations are performed to calculate the charge, scintillation, and triplet helium molecule signals produced by recoil He ions, for a variety of energies and electric fields. We show that excellent background rejection can be achieved based on the ratios between different signal channels. We also present some concepts for a liquid-helium-based dark matter detector. Key to the proposed approach is the use of a large electric field to extract electrons from the event site, and the amplification of this charge signal, through proportional scintillation, liquid electroluminescence, or roton emission. The sensitivity of the proposed detector to light dark matter particles is estimated for various electric fields and light collection efficiencies.
[35]  oai:arXiv.org:1207.3665  [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Comments: 12 pages, 9 figures
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.
[36]  oai:arXiv.org:1211.0836  [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Comments: 12 pages, 4 figures
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
[37]  oai:arXiv.org:1111.3260  [pdf] - 548322
Scintillation yield and time dependence from electronic and nuclear recoils in liquid neon
Comments: 18 pages, 23 figures, v2 updated to reflect published version
Submitted: 2011-11-14, last modified: 2012-08-13
We have performed measurements of scintillation light in liquid neon, observing a signal yield in our detector as high as (3.5 $\pm$ 0.4) photoelectrons/keV. We measure pulse shape discrimination efficiency between electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear recoil energy. We also measure the \leff\, parameter in liquid neon between 30 and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50 keV. We observe a dependence of the scintillation time distribution and signal yield on the pressure and temperature of the liquid neon.
[38]  oai:arXiv.org:1004.0373  [pdf] - 672810
Measurement of scintillation efficiency for nuclear recoils in liquid argon
Comments: revision 2
Submitted: 2010-04-02, last modified: 2012-05-08
The scintillation light yield of liquid argon from nuclear recoils relative to electronic recoils has been measured as a function of recoil energy from 10 keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the nuclear recoil scintillation response to the electronic recoil response, is 0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
[39]  oai:arXiv.org:1110.0103  [pdf] - 967104
After LUX: The LZ Program
Comments: Conference proceedings from APS DPF 2011. 9 pages, 6 figures
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
[40]  oai:arXiv.org:1109.5649  [pdf] - 1084392
Scintillation and charge extraction from the tracks of energetic electrons in superfluid helium-4
Comments: 10 pages, 8 figures
Submitted: 2011-09-26
An energetic electron passing through liquid helium causes ionization along its track. The ionized electrons quickly recombine with the resulting positive ions, which leads to the production of prompt scintillation light. By applying appropriate electric fields, some of the ionized electrons can be separated from their parent ions. The fraction of the ionized electrons extracted in a given applied field depends on the separation distance between the electrons and the ions. We report the determination of the mean electron-ion separation distance for charge pairs produced along the tracks of beta particles in superfluid helium at 1.5 K by studying the quenching of the scintillation light under applied electric fields. Knowledge of this mean separation parameter will aid in the design of particle detectors that use superfluid helium as a target material.
[41]  oai:arXiv.org:1108.1836  [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Comments:
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
[42]  oai:arXiv.org:0910.3698  [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Comments: 8 pages, 4 figures
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_{\chi}\gtrsim150$ GeV are disfavored.
[43]  oai:arXiv.org:1011.6439  [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Comments: Conference proceedings from the Identification of Dark Matter 2010, Montpellier, France. To be published by SISSA as PoS(IDM2010)017
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
[44]  oai:arXiv.org:1007.1005  [pdf] - 283573
A Consistent Dark Matter Interpretation For CoGeNT and DAMA/LIBRA
Comments: 8 pages, 6 figures
Submitted: 2010-07-06, last modified: 2010-10-27
In this paper, we study the recent excess of low energy events observed by the CoGeNT collaboration and the annual modulation reported by the DAMA/LIBRA collaboration, and discuss whether these signals could both be the result of the same elastically scattering dark matter particle. We find that, without channeling but when taking into account uncertainties in the relevant quenching factors, a dark matter candidate with a mass of approximately ~7.0 GeV and a cross section with nucleons of sigma_{DM-N} ~2x10^-4 pb (2x10^-40 cm^2) could account for both of these observations. We also comment on the events recently observed in the oxygen band of the CRESST experiment and point out that these could potentially be explained by such a particle. Lastly, we compare the region of parameter space favored by DAMA/LIBRA and CoGeNT to the constraints from XENON 10, XENON 100, and CDMS (Si) and find that these experiments cannot at this time rule out a dark matter interpretation of these signals.
[45]  oai:arXiv.org:1005.3723  [pdf] - 169132
Response to arXiv:1005.2615
Comments:
Submitted: 2010-05-20
Brief response to a Reply [arXiv:1005.2615] on our Comments [arXiv:1005.0838] on XENON100 recent results [arXiv:1005.0380].
[46]  oai:arXiv.org:1005.0838  [pdf] - 164844
Comments on "First Dark Matter Results from the XENON100 Experiment"
Comments: v3: Figures and appendix added showing the effect of choice of Leff on claimed sensitivity. v2:Important information added to a footnote. Figures enlarged, references fixed
Submitted: 2010-05-05, last modified: 2010-05-12
The XENON100 collaboration has recently released new dark matter limits, placing particular emphasis on their impact on searches known to be sensitive to light-mass (below 10 GeV/c^2) Weakly Interacting Massive Particles (WIMPs), such as DAMA and CoGeNT. We describe here several sources of uncertainty and bias in their analysis that make their new claimed sensitivity presently untenable. In particular, we point out additional work in this field and simple kinematic arguments that indicate that liquid xenon (LXe) may be a relatively insensitive detection medium for the recoil energies (few keV_r) expected from such low mass WIMPs.
[47]  oai:arXiv.org:0909.1063  [pdf] - 142221
Scintillation efficiency and ionization yield of liquid xenon for mono-energetic nuclear recoils down to 4 keV
Comments: 10 pages, 15 figures On version v4 we describe in more detail the trigger setup and have edited several figure to help the reader understand them
Submitted: 2009-09-05, last modified: 2010-01-18
Liquid Xenon (LXe) is an excellent material for experiments designed to detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs). A low energy detection threshold is essential for a sensitive WIMP search. The understanding of the relative scintillation efficiency (Leff) and ionization yield of low energy nuclear recoils in LXe is limited for energies below 10 keV. In this paper, we present new measurements that extend the energy down to 4 keV, finding that Leff decreases with decreasing energy. We also measure the quenching of scintillation efficiency due to the electric field in LXe, finding no significant field dependence.
[48]  oai:arXiv.org:1001.2834  [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Comments:
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
[49]  oai:arXiv.org:0905.1766  [pdf] - 24160
Calibration of a Liquid Xenon Detector with Kr-83m
Comments: Minor edits to match published version
Submitted: 2009-05-12, last modified: 2009-12-11
We report the preparation of a Kr-83m source and its subsequent use in calibrating a liquid xenon detector. Kr-83m atoms were produced through the decay of Rb-83 atoms trapped in zeolite molecular sieve and were then introduced into liquid xenon. Decaying Kr-83m nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and 32.1 keV from the decay of Kr-83m were both observed. This calibration source will allow the characterization of the scintillation and ionization response of noble liquid detectors at low energies, highly valuable for the search for WIMP dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both to understand purification in noble liquid-based particle detectors, as well as for studies of classical and quantum turbulence in superfluid helium.
[50]  oai:arXiv.org:0912.0482  [pdf] - 902613
Status of the LUX Dark Matter Search
Comments: 4 pages, in proceedings of the SUSY09 conference
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.
[51]  oai:arXiv.org:0911.5453  [pdf] - 146838
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Comments: 7 pages, 12 figures
Submitted: 2009-11-30
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$ scintillation peak at 41.5 keV appears in both liquids when filling our detector through a piece of zeolite coated with $^{83}$Rb. Based on this scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a resolution of 6% ($\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a resolution of 19% ($\sigma$/E). The observed peak intensity subsequently decays with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful calibration source for liquid argon and neon dark matter and solar neutrino detectors.
[52]  oai:arXiv.org:0807.0459  [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear recoils
Comments: 8 pages, 9 figures. To be published in Nucl. Instrum. Methods A
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
[53]  oai:arXiv.org:0805.2939  [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Comments: 4 pages, 4 figures; final version published in PRL (added DAMA region to Figure 1)
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
[54]  oai:arXiv.org:0709.1880  [pdf] - 4868
Detection and Imaging of He_2 Molecules in Superfluid Helium
Comments: 4 pages, 5 figures, content revised
Submitted: 2007-09-12, last modified: 2007-12-18
We present data that show a cycling transition can be used to detect and image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate that limitations on the cycling efficiency due to the vibrational structure of the molecule can be mitigated by the use of repumping lasers. Images of the molecules obtained using the method are also shown. This technique gives rise to a new kind of ionizing radiation detector. The use of He$_2$ triplet molecules as tracer particles in the superfluid promises to be a powerful tool for visualization of both quantum and classical turbulence in liquid helium.
[55]  oai:arXiv.org:0706.0039  [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Comments: accepted for publication in Phys. Rev. Lett
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
[56]  oai:arXiv.org:0708.1976  [pdf] - 3998
Preparation of Neutron-activated Xenon for Liquid Xenon Detector Calibration
Comments: to be published in NIM A, corrected typos in Table 1 and Fig.6 of the previous version
Submitted: 2007-08-14, last modified: 2007-09-27
We report the preparation of neutron-activated xenon for the calibration of liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable states, produced by fast neutron activation, were detected and their activities measured in a LXe scintillation detector. Following a five-day activation of natural xenon gas with a Cf-252 (4 x 10^5 n/s) source, the activities of two gamma ray lines at 164 keV and 236 keV, from Xe-131m and Xe-129m metastable states, were measured at about 95 and 130 Bq/kg, respectively. We also observed three additional lines at 35 keV, 100 keV and 275 keV, which decay away within a few days. No long-lifetime activity was observed after the neutron activation.
[57]  oai:arXiv.org:0706.1106  [pdf] - 2001
Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout for a Dark Matter Detector
Comments: To be published in the Proceedings of the 23rd Winter Workshop on Nuclear Dynamics, Big Sky, Montana, February 11-18, 2007. This work is supported by the Yale-Weizmann Collaboration Program of the American Committee on Weizmann Institute of Science (ACWIS), New York
Submitted: 2007-06-07
The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON collaboration. A major issue is the background induced by natural radioactivity of present-detector components including the Photo Multiplier Tubes (PMT) made from glass with large U-Th content. We propose to use advanced Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann Institute of Science (WIS). These "hole-multipliers" will measure in a two-phase (liquid/gas) Xe detector electrons extracted into the gas phase from both ionization in the liquid as well as scintillation-induced photoelectrons from a CsI photocathode immersed in LXe. We report on initial tests (in gas) of THGEM made out of Cirlex (Kapton) which is well known to have low Ra-Th content instead of the usual G10 material with high Ra-Th content.
[58]  oai:arXiv.org:astro-ph/0702202  [pdf] - 89256
Demonstration of photomultiplier tube operation at 29 K
Comments: 3 pages, 5 figures
Submitted: 2007-02-07
We describe measurements of gain, dark current, and quantum efficiency obtained while cooling a Hamamatsu R5912-02-MOD photomultiplier tube from room temperature to 29 K. We found that the PMT operated normally down to 29 K, with a reduced gain and quantum efficiency at the lowest temperatures. Furthermore, we found that the dark count rate increased as the temperature decreased. We conclude that these PMTs appear to be adequate for the requirements of the CLEAN experiment.
[59]  oai:arXiv.org:astro-ph/0612108  [pdf] - 87446
Scintillation of liquid neon from electronic and nuclear recoils
Comments:
Submitted: 2006-12-04
We have measured the time dependence of scintillation light from electronic and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2 us. Pulse shape discrimination is investigated as a means of identifying event type in liquid neon. Finally, the nuclear recoil scintillation efficiency is measured to be 0.26+-0.03 for 387 keV nuclear recoils.
[60]  oai:arXiv.org:astro-ph/0609714  [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Comments: Presented at the 7th UCLA Symposium on "Sources and Detection of Dark Matter and Dark Energy in the Universe"
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
[61]  oai:arXiv.org:astro-ph/0503621  [pdf] - 72003
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Comments: 16 pages, 13 figures. Submitted to Phys. Rev. D
Submitted: 2005-03-29
Liquid Xenon (LXe) is expected to be an excellent target and detector medium to search for dark matter in the form of Weakly Interacting Massive Particles (WIMPs). Knowledge of LXe ionization and scintillation response to low energy nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important for determining the sensitivity of LXe direct detection experiments. Here we report on new measurements of the scintillation yield of Xe recoils with kinetic energy as low as 10 keV. The dependence of the scintillation yield on applied electric field was also measured in the range of 0 to 4 kV/cm. Results are in good agreement with recent theoretical predictions that take into account the effect of biexcitonic collisions in addition to the nuclear quenching effect.
[62]  oai:arXiv.org:nucl-ex/0503006  [pdf] - 118468
Trace Detection of Metastable Helium Molecules in Superfluid Helium by Laser-Induced Fluorescence
Comments: 10 pages, 2 figures. Submitted to Physical Review Letters
Submitted: 2005-03-11
We describe an approach to detecting ionizing radiation that combines the special properties of superfluid helium with the sensitivity of quantum optics techniques. Ionization in liquid helium results in the copious production of metastable helium molecules, which can be detected by laser-induced fluorescence. Each molecule can be probed many times using a cycling transition, resulting in the detection of individual molecules with high signal to noise. This technique could be used to detect neutrinos, weakly interacting massive particles, and ultracold neutrons, and to image superfluid flow in liquid He-4.
[63]  oai:arXiv.org:astro-ph/0407575  [pdf] - 66417
The XENON Dark Matter Search Experiment
Comments: 9 pages, 8 figures, appear in the Proceeding of 6th UCLA Symposium on Sources and Detection of Dark Matter and Dark Energy in the Universe
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest interaction cross section predicted by SUSY models. The TPCs are operated in dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to 16keV energy, via simultaneous detection of the ionization, through secondary scintillation in the gas, and primary scintillation in the liquid. Thedistinct ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or neutrons), and for electron recoils from background, iskey to the event-by-event discrimination capability of XENON. A dual phase xenon prototype has been realized and is currently being tested, along with otherprototypes dedicated to other measurements relevant to the XENON program. As part of the R&D phase, we will realize and move underground a first XENON module (XENON10) with at least 10 kg fiducial mass to measure the background rejection capability and to optimize the conditions for continuous and stable detector operation underground. We present some of the results from the ongoing R&D and summarize the expected performance of the 10 kg experiment, from MonteCarlo simulations. The main design features of the 100 kg detector unit(XENON100), with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will also be presented.
[64]  oai:arXiv.org:astro-ph/0406526  [pdf] - 65683
Radioactive Krypton Background Evaluation Using Atom Counting
Comments: 18 pages, 2 figures. Submitted to Nucl. Inst. and Meth. A
Submitted: 2004-06-23
The beta-decay of $\rm^{85}Kr$ is a significant radioactive background for experiments that use liquified noble gases to search for dark matter and measure the low-energy solar neutrino flux. While there are several proposed methods for reducing Kr levels in these experiments, an independent technique is needed for measuring very low Kr levels. By selectively exciting Kr atoms to a metastable state, capturing them in a magneto-optical trap (MOT), and detecting fluorescence from the trapped atoms, individual Kr atoms can be counted with a high signal-to-noise ratio. This approach could be used to ascertain Kr impurity levels in other noble gases, with an estimated sensitivity of $3\times 10^{-14}$.
[65]  oai:arXiv.org:astro-ph/0402007  [pdf] - 62521
Neutrino Detection With CLEAN
Comments: 21 pages, 3 figures. Submitted to Astroparticle Physics
Submitted: 2004-01-31, last modified: 2004-02-08
This article describes CLEAN, an approach to the detection of low-energy solar neutrinos and neutrinos released from supernovae. The CLEAN concept is based on the detection of elastic scattering events (neutrino-electron scattering and neutrino-nuclear scattering) in liquified noble gases such as liquid helium, liquid neon, and liquid xenon, all of which scintillate brightly in the ultraviolet. Key to the CLEAN technique is the use of a thin film of wavelength-shifting fluor to convert the ultraviolet scintillation light to the visible. This allows the same liquid to be used as both a passive shielding medium and an active self-shielding detector, allowing lower intrinsic radioactive backgrounds at low energies. Liquid neon is a particularly promising medium for CLEAN. Because liquid neon has a high scintillation yield, has no long-lived radioactive isotopes, and can be easily purified by use of cold traps, it is an ideal medium for the detection of rare nuclear events. In addition, neon is inexpensive, dense, and transparent to its own scintillation light, making it practical for use in a large self-shielding apparatus. Monte Carlo simulations of gamma ray backgrounds have been performed assuming liquid neon as both shielding and detection medium. Gamma ray events occur with high probability in the outer parts of the detector. In contrast, neutrino scattering events occur uniformly throughout the detector. We discriminate background gamma ray events from events of interest based on a spatial Maximum Likelihood method estimate of event location. Background estimates for CLEAN are presented, as well as an evaluation of the sensitivity of the detector for $p-p$ neutrinos. Given these simulations, the physics potential of the CLEAN approach is evaluated.
[66]  oai:arXiv.org:physics/0309033  [pdf] - 119023
Spatial methods for event reconstruction in CLEAN
Comments:
Submitted: 2003-09-04
In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed neutrino and dark matter detector, background discrimination is possible if one can determine the location of an ionizing radiation event with high accuracy. We simulate ionizing radiation events that produce multiple scintillation photons within a spherical detection volume filled with liquid neon. We estimate the radial location of a particular ionizing radiation event based on the observed count data corresponding to that event. The count data are collected by detectors mounted at the spherical boundary of the detection volume. We neglect absorption, but account for Rayleigh scattering. To account for wavelength-shifting of the scintillation light, we assume that photons are absorbed and re-emitted at the detectors. Here, we develop spatial Maximum Likelihood methods for event reconstruction, and study their performance in computer simulation experiments. We also study a method based on the centroid of the observed count data. We calibrate our estimates based on training data.
[67]  oai:arXiv.org:astro-ph/0302071  [pdf] - 54698
Supernova Observation Via Neutrino-Nucleus Elastic Scattering in the CLEAN Detector
Comments: 10 pages, 5 figures, submitted to Phys. Rev. D
Submitted: 2003-02-04
Development of large mass detectors for low-energy neutrinos and dark matter may allow supernova detection via neutrino-nucleus elastic scattering. An elastic-scattering detector could observe a few, or more, events per ton for a galactic supernova at 10 kpc ($3.1 \times 10^{20}$ m). This large yield, a factor of at least 20 greater than that for existing light-water detectors, arises because of the very large coherent cross section and the sensitivity to all flavors of neutrinos and antineutrinos. An elastic scattering detector can provide important information on the flux and spectrum of $\nu_\mu$ and $\nu_\tau$ from supernovae. We consider many detectors and a range of target materials from $^4$He to $^{208}$Pb. Monte Carlo simulations of low-energy backgrounds are presented for the liquid-neon-based Cryogenic Low Energy Astrophysics with Noble gases (CLEAN) detector. The simulated background is much smaller than the expected signal from a galactic supernova.
[68]  oai:arXiv.org:astro-ph/9907314  [pdf] - 107539
Liquid Helium and Liquid Neon - Sensitive, Low Background Scintillation Media For the Detection of Low Energy Neutrinos
Comments: 18 pages, 1 figure. To be published in the Journal of Low Temperature Physics. Added: more information about cryogenic considerations and radioactive backgrounds
Submitted: 1999-07-22, last modified: 1999-09-28
The use of liquid helium and neon as scintillators for neutrino detection is investigated. Several unique properties of these cryogens make them promising candidates for real-time solar neutrino spectroscopy: large ultraviolet scintillation yields from ionizing radiation, transparency to their own scintillation light, and low levels of radioactive impurities. When neutrinos scatter from electrons in liquid helium or neon, ultraviolet light is emitted. The ultraviolet scintillation light can be efficiently converted to the visible with wavelength shifting films. In this way the neutrino-electron scattering events can be detected by photomultiplier tubes at room temperature. We conclude that the solar neutrino flux from the $\rm p+p\to e^{+}+d+\nu_{e}$ reaction could be characterized and monitored versus time using a 10 ton mass of liquid helium or neon as a scintillation target.