Normalized to: McKinsey, D.
[1]
oai:arXiv.org:2003.11141 [pdf] - 2070172
An Effective Field Theory Analysis of the First LUX Dark Matter Search
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Balajthy, J.;
Baxter, A.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Boxer, B.;
Brás, P.;
Burdin, S.;
Byram, D.;
Carmona-Benitez, M. C.;
Chan, C.;
Cutter, J. E.;
de Viveiros, L.;
Druszkiewicz, E.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Ghag, C.;
Gilchriese, M. G. D.;
Gwilliam, C.;
Hall, C. R.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Jahangir, O.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Korolkova, E. V.;
Kravitz, S.;
Kudryavtsev, V. A.;
Larsen, N. A.;
Leason, E.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, J.;
Lin, J.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marangou, N.;
McKinsey, D. N.;
Mei, D. -M.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Naylor, A.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
Nilima, A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Riffard, Q.;
Rischbieter, G. R. C.;
Rhyne, C.;
Rossiter, P.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, R.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tvrznikova, L.;
Utku, U.;
Uvarov, S.;
Vacheret, A.;
Velan, V.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Xu, J.;
Zhang, C.
Submitted: 2020-03-24
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass
dual-phase time projection chamber that operated by detecting light and
ionization signals from particles incident on a xenon target. In December 2015,
LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent
WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure
in its first science run. Tension between experiments and the absence of a
definitive positive detection suggest it would be prudent to search for WIMPs
outside the standard spin-independent/spin-dependent paradigm. Recent
theoretical work has identified a complete basis of 14 independent effective
field theory (EFT) operators to describe WIMP-nucleon interactions. In addition
to spin-independent and spin-dependent nuclear responses, these operators can
produce novel responses such as angular-momentum-dependent and spin-orbit
couplings. Here we report on a search for all 14 of these EFT couplings with
data from LUX's first science run. Limits are placed on each coupling as a
function of WIMP mass.
[2]
oai:arXiv.org:1907.06272 [pdf] - 2050176
Extending light WIMP searches to single scintillation photons in LUX
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Baxter, A.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Boxer, B.;
Brás, P.;
Burdin, S.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fallon, S. R.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Genovesi, J.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Grace, E.;
Gwilliam, C.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Jahangir, O.;
Ji, W.;
Kamdin, K.;
Kazka, K.;
Khaitan, D.;
Knoche, R.;
Korolkova, E. V.;
Kravitz, S.;
Kudryavtsev, V. A.;
Larsen, N. A.;
Leason, E.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Levy, C.;
Liao, J.;
Lin, J.;
Lindote, A.;
Lopes, M. I.;
López-Paredes, B.;
Manalaysay, A.;
Mannino, R. L.;
Marangou, N.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Naylor, A.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
Nilima, A.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Reichhart, L.;
Riffard, Q.;
Rischbieter, G. R. C.;
Rossiter, P.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, R.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Utku, U.;
Uvarov, S.;
Vacheret, A.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2019-07-14, last modified: 2019-12-27
We present a novel analysis technique for liquid xenon time projection
chambers that allows for a lower threshold by relying on events with a prompt
scintillation signal consisting of single detected photons. The energy
threshold of the LUX dark matter experiment is primarily determined by the
smallest scintillation response detectable, which previously required a 2-fold
coincidence signal in its photomultiplier arrays, enforced in data analysis.
The technique presented here exploits the double photoelectron emission effect
observed in some photomultiplier models at vacuum ultraviolet wavelengths. We
demonstrate this analysis using an electron recoil calibration dataset and
place new constraints on the spin-independent scattering cross section of
weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass
using the 2013 LUX dataset. This new technique is promising to enhance light
WIMP and astrophysical neutrino searches in next-generation liquid xenon
experiments.
[3]
oai:arXiv.org:1802.06039 [pdf] - 2061504
Projected WIMP sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment
Akerib, D. S.;
Akerlof, C. W.;
Alsum, S. K.;
Araújo, H. M.;
Arthurs, M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Bauer, D.;
Belle, J.;
Beltrame, P.;
Benson, T.;
Bernard, E. P.;
Biesiadzinski, T. P.;
Boast, K. E.;
Boxer, B.;
Brás, P.;
Buckley, J. H.;
Bugaev, V. V.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Chan, C.;
Cherwinka, J. J.;
Cole, A.;
Cottle, A.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
Dahl, C. E.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, W. R.;
Fan, A.;
Fayer, S.;
Fiorucci, S.;
Fruth, T.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
van der Grinten, M. G. D.;
Hall, C. R.;
Hans, S.;
Hanzel, K.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hillbrand, S.;
Hjemfelt, C.;
Hoff, M. D.;
Hor, J. Y-K.;
Huang, D. Q.;
Ignarra, C. M.;
Ji, W.;
Kaboth, A. C.;
Kamdin, K.;
Keefner, J.;
Khaitan, D.;
Khazov, A.;
Kim, Y. D.;
Kocher, C. D.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kreczko, L.;
Krikler, B.;
Kudryavtsev, V. A.;
Kyre, S.;
Lee, J.;
Lenardo, B. G.;
Leonard, D. S.;
Lesko, K. T.;
Levy, C.;
Li, J.;
Liao, J.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Linehan, R.;
Lippincott, W. H.;
Liu, X.;
Lopes, M. I.;
Paredes, B. López;
Lorenzon, W.;
Luitz, S.;
Lyle, J. M.;
Majewski, P.;
Manalaysay, A.;
Mannino, R. L.;
Maupin, C.;
McKinsey, D. N.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Morrison, E.;
Mount, B. J.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikoleyczik, J.;
O'Sullivan, K.;
Olcina, I.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Patton, S. J.;
Pease, E. K.;
Penning, B.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Rhyne, C. A.;
Richards, A.;
Rodrigues, J. P.;
Rosero, R.;
Rossiter, P.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silk, J. J.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stancu, I.;
Stark, M. R.;
Stiegler, T. M.;
Stifter, K.;
Szydagis, M.;
Taylor, W. C.;
Taylor, R.;
Taylor, D. J.;
Temples, D.;
Terman, P. A.;
Thomas, K. J.;
Timalsina, M.;
To, W. H.;
Tomás, A.;
Tope, T. E.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Utku, U.;
Va'vra, J.;
Vacheret, A.;
Verbus, J. R.;
Voirin, E.;
Waldron, W. L.;
Watson, J. R.;
Webb, R. C.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, I.
Submitted: 2018-02-16, last modified: 2019-12-02
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With underground installation well
underway, LZ is on track for commissioning at SURF in 2020.
[5]
oai:arXiv.org:1811.11241 [pdf] - 1981692
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Boxer, B.;
Brás, P.;
Burdin, S.;
Byram, D.;
Carmona-Benitez, M. C.;
Chan, C.;
Cutter, J. E.;
Davison, T. J. R.;
Druszkiewicz, E.;
Fallon, S. R.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
Gwilliam, C.;
Hall, C. R.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Jahangir, O.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Korolkova, E. V.;
Kravitz, S.;
Kudryavtsev, V. A.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, J.;
Lin, J.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marangou, N.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Naylor, A.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Riffard, Q.;
Rischbieter, G. R. C.;
Rhyne, C.;
Rossiter, P.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Utku, U.;
Uvarov, S.;
Velan, V.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Xu, J.;
Yazdani, K.;
Zhang, C.
Submitted: 2018-11-27, last modified: 2019-10-16
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei
is difficult to detect using liquid xenon-based DM search instruments because
the energy transfer during nuclear recoils is smaller than the typical detector
threshold. However, the tree-level DM-nucleus scattering diagram can be
accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called
"Migdal" electron. These provide an electron recoil component to the
experimental signature at higher energies than the corresponding nuclear
recoil. The presence of this signature allows liquid xenon detectors to use
both the scintillation and the ionization signals in the analysis where the
nuclear recoil signal would not be otherwise visible. We report constraints on
spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5
GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013
data from the Large Underground Xenon (LUX) experiment for four different
classes of mediators. This analysis extends the reach of liquid xenon-based DM
search instruments to lower DM masses than has been achieved previously.
[6]
oai:arXiv.org:1903.12372 [pdf] - 1916847
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with
the LUX Detector
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Balajthy, J.;
Baxter, A.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Boxer, B.;
Brás, P.;
Burdin, S.;
Byram, D.;
Carmona-Benitez, M. C.;
Chan, C.;
Cutter, J. E.;
de Viveiros, L.;
Druszkiewicz, E.;
Fallon, S. R.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
Gwilliam, C.;
Hall, C. R.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Jahangir, O.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Korolkova, E. V.;
Kravitz, S.;
Kudryavtsev, V. A.;
Leason, E.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, J.;
Lin, J.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marangou, N.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Naylor, A.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
Nilima, A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Riffard, Q.;
Rischbieter, G. R. C.;
Rhyne, C.;
Rossiter, P.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, R.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Utku, U.;
Uvarov, S.;
Vacheret, A.;
Velan, V.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Xu, J.;
Zhang, C.
Submitted: 2019-03-29, last modified: 2019-06-07
We report results from an extensive set of measurements of the \b{eta}-decay
response in liquid xenon.These measurements are derived from high-statistics
calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX
detector. The mean light-to-charge ratio is reported for 13 electric field
values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145
keV.
[7]
oai:arXiv.org:1807.07113 [pdf] - 1758152
Search for annual and diurnal rate modulations in the LUX experiment
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Boxer, B.;
Brás, P.;
Burdin, S.;
Byram, D.;
Carmona-Benitez, M. C.;
Chan, C.;
Cutter, J. E.;
Davison, T. J. R.;
Druszkiewicz, E.;
Fallon, S. R.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
Gwilliam, C.;
Hall, C. R.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Korolkova, E. V.;
Kravitz, S.;
Kudryavtsev, V. A.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, J.;
Lin, J.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marangou, N.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Rischbieter, G. R. C.;
Rhyne, C.;
Rossiter, P.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Utku, U.;
Uvarov, S.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woodward, D.;
Xu, J.;
Yazdani, K.;
Zhang, C.
Submitted: 2018-07-18, last modified: 2018-09-27
Various dark matter models predict annual and diurnal modulations of dark
matter interaction rates in Earth-based experiments as a result of the Earth's
motion in the halo. Observation of such features can provide generic evidence
for detection of dark matter interactions. This paper reports a search for both
annual and diurnal rate modulations in the LUX dark matter experiment using
over 20 calendar months of data acquired between 2013 and 2016. This search
focuses on electron recoil events at low energies, where leptophilic dark
matter interactions are expected to occur and where the DAMA experiment has
observed a strong rate modulation for over two decades. By using the innermost
volume of the LUX detector and developing robust cuts and corrections, we
obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which
is among the lowest in all dark matter experiments. No statistically
significant annual modulation was observed in energy windows up to
26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis
demonstrates the most sensitive annual modulation search up to date, with
9.2$\sigma$ tension with the DAMA/LIBRA result. We also report no observation
of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between
2 and 6~keV$_{\text{ee}}$.
[8]
oai:arXiv.org:1803.10110 [pdf] - 1656542
Is DAMA Bathing in a Sea of Radioactive Argon?
Submitted: 2018-03-27
A hypothesis is proposed to explain the long-standing DAMA/LIBRA puzzle.
Introduced into the DAMA/LIBRA shielding is a purge gas of nominally
high-purity nitrogen, which under this hypothesis contains argon impurities.
Argon is introduced into the nitrogen purge gas either through leaks in the
purge gas plumbing, or through commercially-supplied bottled nitrogen, diffuses
through materials in the detector housings, and then comes in direct contact
with the DAMA/LIBRA detectors. These argon impurities can then lead to a
modulating 2.8 keV background under two scenarios. Scenario 1): These
impurities include the isotope 37Ar, which decays by electron capture, emitting
a 2.8 keV x-ray. These decays appear as single-site, monoenergetic events in
DAMA/LIBRA, and produce an annual modulation due to the variation of neutron
flux in the atmosphere and at the Earth's surface, which in turn leads to a
seasonal variation in 37Ar production from the reactions
$^{40}\textrm{Ca}(\textrm{n,}\alpha)^{37}\textrm{Ar}$ and
$^{36}\textrm{Ar}(\textrm{n,}\gamma)^{37}\textrm{Ar}$. Scenario 2): Radon is
also in the DAMA/LIBRA purge gas, modulating seasonally at a rate below the
current DAMA/LIBRA limits. When radon or its short-lived daughters decay, the
resulting beta, gamma, and bremsstrahlung radiation cause stable 40Ar to be
ionized within the copper housings surrounding the NaI(Tl) detectors, resulting
in characteristic 2.8 keV x-rays. Modulating backgrounds might also result from
radon-induced neutron or gamma-ray flux from the surrounding cavern, leading to
a small modulating background enhanced at low energy by the presence of 40Ar
within the copper housings. These two scenarios are straightforward to test
through assay of the purge gas as well as Monte Carlo and laboratory study of
the DAMA/LIBRA copper housings when excited by ionizing radiation.
[9]
oai:arXiv.org:1709.00800 [pdf] - 1611913
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron
Capture
LUX Collaboration;
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Druszkiewicz, E.;
Edwards, B. N.;
Fallon, S. R.;
Fan, A.;
Fiorucci, S.;
Gaitskell, R. J.;
Genovesi, J.;
Ghag, C.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2017-09-03
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$
and fluctuations for electronic recoil events in liquid xenon at discrete
energies between 186 eV and 33.2 keV. The average electric field applied across
the liquid xenon target is 180 V/cm. The data are obtained using low energy
$^{127}$Xe electron capture decay events from the 95.0-day first run from LUX
(WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The
sequence of gamma-ray and X-ray cascades associated with $^{127}$I
de-excitations produces clearly identified 2-vertex events in the LUX detector.
We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and
N- (186 eV) shell cascade events and verify that the relative ratio of observed
events for each shell agrees with calculations. The N-shell cascade analysis
includes single extracted electron (SE) events and represents the lowest-energy
electronic recoil $\textit{in situ}$ measurements that have been explored in
liquid xenon.
[11]
oai:arXiv.org:1704.02297 [pdf] - 1582421
First Searches for Axions and Axion-Like Particles with the LUX
Experiment
Akerib, D. S.;
Alsum, S.;
Aquino, C.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fallon, S. R.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2017-04-07, last modified: 2017-06-30
The first searches for axions and axion-like particles with the Large
Underground Xenon (LUX) experiment are presented. Under the assumption of an
axio-electric interaction in xenon, the coupling constant between axions and
electrons, gAe is tested, using data collected in 2013 with an exposure
totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood
ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90%
C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper
limit in coupling corresponds to an upper limit on axion mass of 0.12
eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are
excluded. For galactic axion-like particles, values of gAe larger than 4.2
$\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16
keV/c$^{2}$. These are the most stringent constraints to date for these
interactions.
[12]
oai:arXiv.org:1705.03380 [pdf] - 1583256
Limits on spin-dependent WIMP-nucleon cross section obtained from the
complete LUX exposure
LUX Collaboration;
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fallon, S. R.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Velan, V.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2017-05-09, last modified: 2017-06-23
We present experimental constraints on the spin-dependent WIMP-nucleon
elastic cross sections from the total 129.5 kg-year exposure acquired by the
Large Underground Xenon experiment (LUX), operating at the Sanford Underground
Research Facility in Lead, South Dakota (USA). A profile likelihood ratio
analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton)
cross section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ =
5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement
over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron
limit is the most sensitive constraint to date.
[14]
oai:arXiv.org:1608.07648 [pdf] - 1531370
Results from a search for dark matter in the complete LUX exposure
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bramante, R.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O`Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2016-08-26, last modified: 2017-01-13
We report constraints on spin-independent weakly interacting massive particle
(WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large
Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber
with 250 kg of active mass is operated at the Sanford Underground Research
Facility under Lead, South Dakota (USA). With roughly fourfold improvement in
sensitivity for high WIMP masses relative to our previous results, this search
yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2,
WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at
the 90% confidence level. When combined with the previously reported LUX
exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
[15]
oai:arXiv.org:1608.05381 [pdf] - 1503451
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark
matter experiment using D-D neutron scattering kinematics
LUX Collaboration;
Akerib, D. S.;
Alsum, S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bradley, A.;
Bramante, R.;
Brás, P.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O'Sullivan, K.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C. A.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solmaz, M.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W. C.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Xu, J.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2016-08-18, last modified: 2016-10-26
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon
time projection chamber (TPC) operating at the Sanford Underground Research
Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid
xenon was performed $\textit{in situ}$ in the LUX detector using a collimated
beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium
(D-D) fusion source. The nuclear recoil energy from the first neutron scatter
in the TPC was reconstructed using the measured scattering angle defined by
double-scatter neutron events within the active xenon volume. We measured the
absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric
field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to
74 keV, respectively. This calibration of the nuclear recoil signal yields will
permit the further refinement of liquid xenon nuclear recoil signal models and,
importantly for dark matter searches, clearly demonstrates measured ionization
and scintillation signals in this medium at recoil energies down to
$\mathcal{O}$(1 keV).
[16]
oai:arXiv.org:0904.2930 [pdf] - 1488343
Measurement of the scintillation time spectra and pulse-shape
discrimination of low-energy beta and nuclear recoils in liquid argon with
DEAP-1
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bonatt, J.;
Boudjemline, K.;
Boulay, M. G.;
Broerman, B.;
Bueno, J. F.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Cranshaw, D.;
Dering, K.;
Duncan, F.;
Fatemighomi, N.;
Ford, R.;
Gagnon, R.;
Giampa, P.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Grace, E.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Hamstra, M.;
Harvey, P.;
Hearns, C.;
Hofgartner, J.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
La Zia, F.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
Mehdiyev, R.;
McKinsey, D. N.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, A. J.;
O'Dwyer, E.;
Olsen, K.;
Ouellet, C.;
Pasuthip, P.;
Peeters, S. J. M.;
Pollmann, T.;
Rau, W.;
Retière, F.;
Ronquest, M.;
Seeburn, N.;
Skensved, P.;
Smith, B.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Walding, J.;
Ward, M.
Submitted: 2009-04-20, last modified: 2016-09-14
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be $<1.4\times
10^{-7}$ (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains $1.23\times10^8$ events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
$<2.7\times10^{-8}$ (90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. $10^{-10}$ for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of $10^{-46}$ cm$^2$, assuming
negligible contribution from nuclear recoil backgrounds.
[18]
oai:arXiv.org:1512.03506 [pdf] - 1406496
Improved Limits on Scattering of Weakly Interacting Massive Particles
from Reanalysis of 2013 LUX data
LUX Collaboration;
Akerib, D. S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bradley, A.;
Bramante, R.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Manalaysay, A.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O`Sullivan, K.;
Oliver-Mallory, K. C.;
Ott, R. A.;
Palladino, K. J.;
Pangilinan, M.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Yazdani, K.;
Young, S. K.;
Zhang, C.
Submitted: 2015-12-10, last modified: 2016-05-16
We present constraints on weakly interacting massive particles (WIMP)-nucleus
scattering from the 2013 data of the Large Underground Xenon dark matter
experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure.
This new analysis incorporates several advances: single-photon calibration at
the scintillation wavelength, improved event-reconstruction algorithms, a
revised background model including events originating on the detector walls in
an enlarged fiducial volume, and new calibrations from decays of an injected
tritium $\beta$ source and from kinematically constrained nuclear recoils down
to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to
our previous results which modeled the signal only above a 3 keV minimum
energy. Under standard dark matter halo assumptions and in the mass range above
4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct
limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper
limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
[19]
oai:arXiv.org:1512.03133 [pdf] - 1402511
Tritium calibration of the LUX dark matter experiment
LUX Collaboration;
Akerib, D. S.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boulton, E. M.;
Bradley, A.;
Bramante, R.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Currie, A.;
Cutter, J. E.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edwards, B. N.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C. R.;
Hanhardt, M.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hogan, D. P.;
Horn, M.;
Huang, D. Q.;
Ignarra, C. M.;
Ihm, M.;
Jacobsen, R. G.;
Ji, W.;
Kazkaz, K.;
Khaitan, D.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Manalaysay, A. G.;
Mannino, R. L.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. M.;
Mock, J.;
Moongweluwan, M.;
Morad, J. A.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H. N.;
Neves, F.;
O`Sullivan, K.;
Oliver-Mallory, K. C.;
Ott, R. A.;
Palladino, K. J.;
Pangilinan, M.;
Pease, E. K.;
Phelps, P.;
Reichhart, L.;
Rhyne, C.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
Stephenson, S.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Tiedt, D. R.;
To, W. H.;
Tripathi, M.;
Tvrznikova, L.;
Uvarov, S.;
Verbus, J. R.;
Webb, R. C.;
White, J. T.;
Whitis, T. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Young, S. K.;
Zhang, C.
Submitted: 2015-12-09, last modified: 2016-05-05
We present measurements of the electron-recoil (ER) response of the LUX dark
matter detector based upon 170,000 highly pure and spatially-uniform tritium
decays. We reconstruct the tritium energy spectrum using the combined energy
model and find good agreement with expectations. We report the average charge
and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and
compare the results to the NEST model. We also measure the mean charge
recombination fraction and its fluctuations, and we investigate the location
and width of the LUX ER band. These results provide input to a re-analysis of
the LUX Run3 WIMP search.
[20]
oai:arXiv.org:1509.02910 [pdf] - 1286987
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration;
Akerib, D. S.;
Akerlof, C. W.;
Akimov, D. Yu.;
Alsum, S. K.;
Araújo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Balashov, S.;
Barry, M. J.;
Bauer, P.;
Beltrame, P.;
Bernard, E. P.;
Bernstein, A.;
Biesiadzinski, T. P.;
Boast, K. E.;
Bolozdynya, A. I.;
Boulton, E. M.;
Bramante, R.;
Buckley, J. H.;
Bugaev, V. V.;
Bunker, R.;
Burdin, S.;
Busenitz, J. K.;
Carels, C.;
Carlsmith, D. L.;
Carlson, B.;
Carmona-Benitez, M. C.;
Cascella, M.;
Chan, C.;
Cherwinka, J. J.;
Chiller, A. A.;
Chiller, C.;
Craddock, W. W.;
Currie, A.;
Cutter, J. E.;
da Cunha, J. P.;
Dahl, C. E.;
Dasu, S.;
Davison, T. J. R.;
de Viveiros, L.;
Dobi, A.;
Dobson, J. E. Y.;
Druszkiewicz, E.;
Edberg, T. K.;
Edwards, B. N.;
Edwards, W. R.;
Elnimr, M. M.;
Emmet, W. T.;
Faham, C. H.;
Fiorucci, S.;
Ford, P.;
Francis, V. B.;
Fu, C.;
Gaitskell, R. J.;
Gantos, N. J.;
Gehman, V. M.;
Gerhard, R. M.;
Ghag, C.;
Gilchriese, M. G. D.;
Gomber, B.;
Hall, C. R.;
Harris, A.;
Haselschwardt, S. J.;
Hertel, S. A.;
Hoff, M. D.;
Holbrook, B.;
Holtom, E.;
Huang, D. Q.;
Hurteau, T. W.;
Ignarra, C. M.;
Jacobsen, R. G.;
Ji, W.;
Ji, X.;
Johnson, M.;
Ju, Y.;
Kamdin, K.;
Kazkaz, K.;
Khaitan, D.;
Khazov, A.;
Khromov, A. V.;
Konovalov, A. M.;
Korolkova, E. V.;
Kraus, H.;
Krebs, H. J.;
Kudryavtsev, V. A.;
Kumpan, A. V.;
Kyre, S.;
Larsen, N. A.;
Lee, C.;
Lenardo, B. G.;
Lesko, K. T.;
Liao, F. -T.;
Lin, J.;
Lindote, A.;
Lippincott, W. H.;
Liu, J.;
Liu, X.;
Lopes, M. I.;
Lorenzon, W.;
Luitz, S.;
Majewski, P.;
Malling, D. C.;
Manalaysay, A. G.;
Manenti, L.;
Mannino, R. L.;
Markley, D. J.;
Martin, T. J.;
Marzioni, M. F.;
McKinsey, D. N.;
Mei, D. -M.;
Meng, Y.;
Miller, E. H.;
Mock, J.;
Monzani, M. E.;
Morad, J. A.;
Murphy, A. St. J.;
Nelson, H. N.;
Neves, F.;
Nikkel, J. A.;
O'Neill, F. G.;
O'Dell, J.;
O'Sullivan, K.;
Olevitch, M. A.;
Oliver-Mallory, K. C.;
Palladino, K. J.;
Pangilinan, M.;
Patton, S. J.;
Pease, E. K.;
Piepke, A.;
Powell, S.;
Preece, R. M.;
Pushkin, K.;
Ratcliff, B. N.;
Reichenbacher, J.;
Reichhart, L.;
Rhyne, C.;
Rodrigues, J. P.;
Rose, H. J.;
Rosero, R.;
Saba, J. S.;
Sarychev, M.;
Schnee, R. W.;
Schubnell, M. S. G.;
Scovell, P. R.;
Shaw, S.;
Shutt, T. A.;
Silva, C.;
Skarpaas, K.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Sosnovtsev, V. V.;
Stancu, I.;
Stark, M. R.;
Stephenson, S.;
Stiegler, T. M.;
Sumner, T. J.;
Sundarnath, K.;
Szydagis, M.;
Taylor, D. J.;
Taylor, W.;
Tennyson, B. P.;
Terman, P. A.;
Thomas, K. J.;
Thomson, J. A.;
Tiedt, D. R.;
To, W. H.;
Tomás, A.;
Tripathi, M.;
Tull, C. E.;
Tvrznikova, L.;
Uvarov, S.;
Va'vra, J.;
van der Grinten, M. G. D.;
Verbus, J. R.;
Vuosalo, C. O.;
Waldron, W. L.;
Wang, L.;
Webb, R. C.;
Wei, W. -Z.;
While, M.;
White, D. T.;
Whitis, T. J.;
Wisniewski, W. J.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, E.;
Woodward, D.;
Worm, S. D.;
Yeh, M.;
Yin, J.;
Young, S. K.;
Zhang, C.
Submitted: 2015-09-09, last modified: 2015-09-23
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of
March 2015 in this Conceptual Design Report. LZ is a second-generation
dark-matter detector with the potential for unprecedented sensitivity to weakly
interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds
of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most
sensitive experiment for WIMPs in this mass region by the end of the decade.
This report describes in detail the design of the LZ technical systems.
Expected backgrounds are quantified and the performance of the experiment is
presented. The LZ detector will be located at the Sanford Underground Research
Facility in South Dakota. The organization of the LZ Project and a summary of
the expected cost and current schedule are given.
[21]
oai:arXiv.org:1305.1605 [pdf] - 1241296
Dark Matter in the Coming Decade: Complementary Paths to Discovery and
Beyond
Bauer, Daniel;
Buckley, James;
Cahill-Rowley, Matthew;
Cotta, Randel;
Drlica-Wagner, Alex;
Feng, Jonathan L.;
Funk, Stefan;
Hewett, JoAnne;
Hooper, Dan;
Ismail, Ahmed;
Kaplinghat, Manoj;
Kusenko, Alexander;
Matchev, Konstantin;
McKinsey, Daniel;
Rizzo, Tom;
Shepherd, William;
Tait, Tim M. P.;
Wijangco, Alexander M.;
Wood, Matthew
Submitted: 2013-05-07, last modified: 2015-07-03
In this report we summarize the many dark matter searches currently being
pursued through four complementary approaches: direct detection, indirect
detection, collider experiments, and astrophysical probes. The essential
features of broad classes of experiments are described, each with their own
strengths and weaknesses. The complementarity of the different dark matter
searches is discussed qualitatively and illustrated quantitatively in two
simple theoretical frameworks. Our primary conclusion is that the diversity of
possible dark matter candidates requires a balanced program drawing from all
four approaches.
[22]
oai:arXiv.org:1408.1914 [pdf] - 1216195
Improving Photoelectron Counting and Particle Identification in
Scintillation Detectors with Bayesian Techniques
Akashi-Ronquest, M.;
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Bodmer, M.;
Boulay, M. G.;
Broerman, B.;
Buck, B.;
Butcher, A.;
Cai, B.;
Caldwell, T.;
Chen, M.;
Chen, Y.;
Cleveland, B.;
Coakley, K.;
Dering, K.;
Duncan, F. A.;
Formaggio, J. A.;
Gagnon, R.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Golovko, V. V.;
Gorel, P.;
Graham, K.;
Grace, E.;
Guerrero, N.;
Guiseppe, V.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Henning, R.;
Hime, A.;
Hofgartner, J.;
Jaditz, S.;
Jillings, C. J.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Kuzniak, M.;
LaTorre, A.;
Lawson, I.;
Li, O.;
Lidgard, J. J.;
Liimatainen, P.;
Linden, S.;
McFarlane, K.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mathew, R.;
McDonald, A. B.;
Mei, D. -M.;
Monroe, J.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J. A.;
Noble, T.;
O'Dwyer, E.;
Olsen, K.;
Gann, G. D. Orebi;
Ouellet, C.;
Palladino, K.;
Pasuthip, P.;
Perumpilly, G.;
Pollmann, T.;
Rau, P.;
Retiere, F.;
Rielage, K.;
Schnee, R.;
Seibert, S.;
Skensved, P.;
Sonley, T.;
Vazquez-Jauregui, E.;
Veloce, L.;
Walding, J.;
Wang, B.;
Wang, J.;
Ward, M.;
Zhang, C.
Submitted: 2014-08-08, last modified: 2014-12-12
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
[23]
oai:arXiv.org:1211.0909 [pdf] - 890838
Radon backgrounds in the DEAP-1 liquid-argon-based Dark Matter detector
Amaudruz, P. -A.;
Batygov, M.;
Beltran, B.;
Boudjemline, K.;
Caldwell, M. G. Boulay B. Cai T.;
Chen, M.;
Chouinard, R.;
Cleveland, B. T.;
Contreras, D.;
Dering, K.;
Duncan, F.;
Ford, R.;
Giuliani, R. Gagnon F.;
Golovko, M. Gold V. V.;
Gorel, P.;
Graham, K.;
Grant, D. R.;
Hakobyan, R.;
Hallin, A. L.;
Harvey, P.;
Hearns, C.;
Jillings, C. J.;
Kuźniak, M.;
Lawson, I.;
Li, O.;
Lidgard, J.;
Liimatainen, P.;
Lippincott, W. H.;
Mathew, R.;
McDonald, A. B.;
McElroy, T.;
McFarlane, K.;
McKinsey, D.;
Muir, A.;
Nantais, C.;
Nicolics, K.;
Nikkel, J.;
Noble, T.;
O'Dwyer, E.;
Olsen, K. S.;
Ouellet, C.;
Pasuthip, P.;
Pollmann, T.;
Rau, W.;
Retiere, F.;
Ronquest, M.;
Skensved, P.;
Sonley, T.;
Tang, J.;
Vázquez-Jáuregui, E.;
Veloce, L.;
Ward, M.
Submitted: 2012-11-05, last modified: 2014-04-23
The DEAP-1 \SI{7}{kg} single phase liquid argon scintillation detector was
operated underground at SNOLAB in order to test the techniques and measure the
backgrounds inherent to single phase detection, in support of the
\mbox{DEAP-3600} Dark Matter detector. Backgrounds in DEAP are controlled
through material selection, construction techniques, pulse shape discrimination
and event reconstruction. This report details the analysis of background events
observed in three iterations of the DEAP-1 detector, and the measures taken to
reduce them.
The $^{222}$Rn decay rate in the liquid argon was measured to be between 16
and \SI{26}{\micro\becquerel\per\kilogram}. We found that the background
spectrum near the region of interest for Dark Matter detection in the DEAP-1
detector can be described considering events from three sources: radon
daughters decaying on the surface of the active volume, the expected rate of
electromagnetic events misidentified as nuclear recoils due to inefficiencies
in the pulse shape discrimination, and leakage of events from outside the
fiducial volume due to imperfect position reconstruction. These backgrounds
statistically account for all observed events, and they will be strongly
reduced in the DEAP-3600 detector due to its higher light yield and simpler
geometry.
[24]
oai:arXiv.org:1403.4842 [pdf] - 799232
Update on the MiniCLEAN Dark Matter Experiment
Rielage, K.;
Akashi-Ronquest, M.;
Bodmer, M.;
Bourque, R.;
Buck, B.;
Butcher, A.;
Caldwell, T.;
Chen, Y.;
Coakley, K.;
Flores, E.;
Formaggio, J. A.;
Gastler, D.;
Giuliani, F.;
Gold, M.;
Grace, E.;
Griego, J.;
Guerrero, N.;
Guiseppe, V.;
Henning, R.;
Hime, A.;
Jaditz, S.;
Kachulis, C.;
Kearns, E.;
Kelsey, J.;
Klein, J. R.;
Latorre, A.;
Lawson, I.;
Linden, S.;
Lopez, F.;
McKinsey, D. N.;
MacMullin, S.;
Mastbaum, A.;
Mei, D. -M.;
Monroe, J.;
Nikkel, J. A.;
Oertel, J.;
Gann, G. D. Orebi;
Palladino, K.;
Perumpilly, G.;
Rodriguez, L.;
Schnee, R.;
Seibert, S.;
Walding, J.;
Wang, B.;
Wang, J.;
Zhang, C.
Submitted: 2014-03-19
The direct search for dark matter is entering a period of increased
sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One
such technology that is being examined is a scintillation only noble liquid
experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to
detect nuclear recoils from WIMP dark matter and serves as a demonstration for
a future detector of order 50 to 100 tonnes. The liquid cryogen is
interchangeable between argon and neon to study the A$^{2}$ dependence of the
potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular
design with spherical geometry to maximize the light yield using cold
photomultiplier tubes in a single-phase detector. Pulse shape discrimination
techniques are used to separate nuclear recoil signals from electron recoil
backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate
the effective reach of the pulse shape discrimination capability. Assembly of
the experiment is underway at SNOLAB and an update on the project is given.
[25]
oai:arXiv.org:1403.1299 [pdf] - 862558
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Coffey, T.;
Currie, A.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kazkaz, K.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
O'Sullivan, K.;
Sumner, T. J.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2014-03-05
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare
low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The
radiogenic backgrounds in the LUX detector have been measured and compared with
Monte Carlo simulation. Measurements of LUX high-energy data have provided
direct constraints on all background sources contributing to the background
model. The expected background rate from the background model for the 85.3 day
WIMP search run is
$(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$
in a 118~kg fiducial volume. The observed background rate is
$(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$,
consistent with model projections. The expectation for the radiogenic
background in a subsequent one-year run is presented.
[26]
oai:arXiv.org:1402.3731 [pdf] - 788195
A Detailed Look at the First Results from the Large Underground Xenon
(LUX) Dark Matter Experiment
Szydagis, M.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Coffey, T.;
Currie, A.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kazkaz, K.;
Knoche, R.;
Larsen, N. A.;
Lee, C.;
Lindote, A.;
Lopes, M. I.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Solovov, V. N.;
Sorensen, P.;
O'Sullivan, K.;
Sumner, T.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Witherell, M. S.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2014-02-15, last modified: 2014-02-25
LUX, the world's largest dual-phase xenon time-projection chamber, with a
fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is
currently the most sensitive direct dark matter search experiment. The initial
null-result limit on the spin-independent WIMP-nucleon scattering cross-section
was released in October 2013, with a primary scintillation threshold of 2 phe,
roughly 3 keVnr for LUX. The detector has been deployed at the Sanford
Underground Research Facility (SURF) in Lead, South Dakota, and is the first
experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$
cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale
employed to better understand the nuclear recoil light and charge yields, and
of the calibration sources, including the new internal tritium source. We found
the LUX data to be in conflict with low-mass WIMP signal interpretations of
other results.
[27]
oai:arXiv.org:1310.8214 [pdf] - 795009
First results from the LUX dark matter experiment at the Sanford
Underground Research Facility
LUX Collaboration;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bailey, A. J.;
Balajthy, J.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chan, C.;
Chapman, J. J.;
Chiller, A. A.;
Chiller, C.;
Clark, K.;
Coffey, T.;
Currie, A.;
Curioni, A.;
Dazeley, S.;
de Viveiros, L.;
Dobi, A.;
Dobson, J.;
Dragowsky, E. M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Flores, C.;
Gaitskell, R. J.;
Gehman, V. M.;
Ghag, C.;
Gibson, K. R.;
Gilchriese, M. G. D.;
Hall, C.;
Hanhardt, M.;
Hertel, S. A.;
Horn, M.;
Huang, D. Q.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Kyre, S.;
Lander, R.;
Larsen, N. A.;
Lee, C.;
Leonard, D. S.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Moongweluwan, M.;
Morad, J.;
Morii, M.;
Murphy, A. St. J.;
Nehrkorn, C.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Ott, R. A.;
Pangilinan, M.;
Parker, P. D.;
Pease, E. K.;
Pech, K.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Sofka, C. J.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
O`Sullivan, K.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tennyson, B.;
Tiedt, D. R.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
White, D.;
Witherell, M. S.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2013-10-30, last modified: 2014-02-05
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.
[28]
oai:arXiv.org:1401.6085 [pdf] - 776010
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 4:
Cosmic Frontier
Feng, J. L.;
Ritz, S.;
Beatty, J. J.;
Buckley, J.;
Cowen, D. F.;
Cushman, P.;
Dodelson, S.;
Galbiati, C.;
Honscheid, K.;
Hooper, D.;
Kaplinghat, M.;
Kusenko, A.;
Matchev, K.;
McKinsey, D.;
Nelson, A. E.;
Olinto, A.;
Profumo, S.;
Robertson, H.;
Rosenberg, L.;
Sinnis, G.;
Tait, T. M. P.
Submitted: 2014-01-23
These reports present the results of the 2013 Community Summer Study of the
APS Division of Particles and Fields ("Snowmass 2013") on the future program of
particle physics in the U.S. Chapter 4, on the Cosmic Frontier, discusses the
program of research relevant to cosmology and the early universe. This area
includes the study of dark matter and the search for its particle nature, the
study of dark energy and inflation, and cosmic probes of fundamental
symmetries.
[29]
oai:arXiv.org:1310.8327 [pdf] - 741475
Snowmass CF1 Summary: WIMP Dark Matter Direct Detection
Cushman, P.;
Galbiati, C.;
McKinsey, D. N.;
Robertson, H.;
Tait, T. M. P.;
Bauer, D.;
Borgland, A.;
Cabrera, B.;
Calaprice, F.;
Cooley, J.;
Empl, T.;
Essig, R.;
Figueroa-Feliciano, E.;
Gaitskell, R.;
Golwala, S.;
Hall, J.;
Hill, R.;
Hime, A.;
Hoppe, E.;
Hsu, L.;
Hungerford, E.;
Jacobsen, R.;
Kelsey, M.;
Lang, R. F.;
Lippincott, W. H.;
Loer, B.;
Luitz, S.;
Mandic, V.;
Mardon, J.;
Maricic, J.;
Maruyama, R.;
Mahapatra, R.;
Nelson, H.;
Orrell, J.;
Palladino, K.;
Pantic, E.;
Partridge, R.;
Ryd, A.;
Saab, T.;
Sadoulet, B.;
Schnee, R.;
Shepherd, W.;
Sonnenschein, A.;
Sorensen, P.;
Szydagis, M.;
Volansky, T.;
Witherell, M.;
Wright, D.;
Zurek, K.
Submitted: 2013-10-30, last modified: 2013-11-03
As part of the Snowmass process, the Cosmic Frontier WIMP Direct Detection
subgroup (CF1) has drawn on input from the Cosmic Frontier and the broader
Particle Physics community to produce this document. The charge to CF1 was (a)
to summarize the current status and projected sensitivity of WIMP direct
detection experiments worldwide, (b) motivate WIMP dark matter searches over a
broad parameter space by examining a spectrum of WIMP models, (c) establish a
community consensus on the type of experimental program required to explore
that parameter space, and (d) identify the common infrastructure required to
practically meet those goals.
[30]
oai:arXiv.org:1310.8621 [pdf] - 740578
Dark Matter in the Coming Decade: Complementary Paths to Discovery and
Beyond
Arrenberg, Sebastian;
Baer, Howard;
Barger, Vernon;
Baudis, Laura;
Bauer, Daniel;
Buckley, James;
Cahill-Rowley, Matthew;
Cotta, Randel;
Drlica-Wagner, Alex;
Feng, Jonathan L.;
Funk, Stefan;
Hewett, JoAnne;
Hooper, Dan;
Ismail, Ahmed;
Kaplinghat, Manoj;
Kong, Kyoungchul;
Kusenko, Alexander;
Matchev, Konstantin;
McCaskey, Mathew;
McKinsey, Daniel;
Mickelson, Dan;
Rizzo, Tom;
Sanford, David;
Shaughnessy, Gabe;
Shepherd, William;
Tait, Tim M. P.;
Tata, Xerxes;
Tulin, Sean;
Wijangco, Alexander M.;
Wood, Matthew;
Yoo, Jonghee;
Yu, Hai-Bo
Submitted: 2013-10-31
In this Report we discuss the four complementary searches for the identity of
dark matter: direct detection experiments that look for dark matter interacting
in the lab, indirect detection experiments that connect lab signals to dark
matter in our own and other galaxies, collider experiments that elucidate the
particle properties of dark matter, and astrophysical probes sensitive to
non-gravitational interactions of dark matter. The complementarity among the
different dark matter searches is discussed qualitatively and illustrated
quantitatively in several theoretical scenarios. Our primary conclusion is that
the diversity of possible dark matter candidates requires a balanced program
based on all four of those approaches.
[31]
oai:arXiv.org:1205.2272 [pdf] - 873784
An Ultra-Low Background PMT for Liquid Xenon Detectors
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Chan, Y-D.;
Clark, K.;
Coffey, T.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Larsen, N.;
Lee, C.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Thomson, J.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-05-10, last modified: 2013-06-24
Results are presented from radioactivity screening of two models of
photomultiplier tubes designed for use in current and future liquid xenon
experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark
matter experiment, has yielded a positive detection of four common radioactive
isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered
backgrounds from other detector materials subdominant to the R8778
contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also
been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th
/ <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to
a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT,
between R8778 and R11410 MOD, concurrent with a doubling of the photocathode
surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable
between the PMTs, but can be significantly reduced in future R11410 MOD units
through further material selection. Assuming PMT activity equal to the measured
90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs
with R11410 MOD PMTs will change LUX PMT electron recoil background
contributions by a factor of \times1/25 after further material selection for
60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The
strong reduction in backgrounds below the measured R8778 levels makes the
R11410 MOD a very competitive technology for use in large-scale liquid xenon
detectors.
[32]
oai:arXiv.org:1104.3088 [pdf] - 661239
A search for light dark matter in XENON10 data
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2011-04-15, last modified: 2013-05-07
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
[33]
oai:arXiv.org:1210.4569 [pdf] - 630139
Technical Results from the Surface Run of the LUX Dark Matter Experiment
LUX Collaboration;
Akerib, D. S.;
Bai, X.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Byram, D.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Chapman, J. J.;
Coffey, T.;
Dobi, A.;
Dragowsky, E.;
Druszkiewicz, E.;
Edwards, B.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Gilchriese, M.;
Hall, C.;
Hanhardt, M.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Knoche, R.;
Larsen, N.;
Lee, C.;
Lesko, K. T.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Moongweluwan, M.;
Morii, M.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Pech, K.;
Phelps, P.;
Rodionov, A.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V. N.;
Sorensen, P.;
Stiegler, T.;
Sweany, M.;
Szydagis, M.;
Taylor, D.;
Tripathi, M.;
Uvarov, S.;
Verbus, J. R.;
de Viveiros, L.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-10-16, last modified: 2013-02-22
We present the results of the three-month above-ground commissioning run of
the Large Underground Xenon (LUX) experiment at the Sanford Underground
Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid
xenon detector that will search for cold dark matter in the form of Weakly
Interacting Massive Particles (WIMPs). The commissioning run, conducted with
the detector immersed in a water tank, validated the integration of the various
sub-systems in preparation of the underground deployment. Using the data
collected, we report excellent light collection properties, achieving 8.4
photoelectrons per keV for 662 keV electron recoils without an applied electric
field, measured in the center of the WIMP target. We also find good energy and
position resolution in relatively high-energy interactions from a variety of
internal and external sources. Finally, we have used the commissioning data to
tune the optical properties of our simulation and report updated sensitivity
projections for spin-independent WIMP-nucleon scattering.
[34]
oai:arXiv.org:1302.0534 [pdf] - 1159464
A Concept for A Dark Matter Detector Using Liquid Helium-4
Submitted: 2013-02-03, last modified: 2013-02-19
Direct searches for light dark matter particles (mass $<10$ GeV) are
especially challenging because of the low energies transferred in elastic
scattering to typical heavy nuclear targets. We investigate the possibility of
using liquid Helium-4 as a target material, taking advantage of the favorable
kinematic matching of the Helium nucleus to light dark matter particles. Monte
Carlo simulations are performed to calculate the charge, scintillation, and
triplet helium molecule signals produced by recoil He ions, for a variety of
energies and electric fields. We show that excellent background rejection can
be achieved based on the ratios between different signal channels. We also
present some concepts for a liquid-helium-based dark matter detector. Key to
the proposed approach is the use of a large electric field to extract electrons
from the event site, and the amplification of this charge signal, through
proportional scintillation, liquid electroluminescence, or roton emission. The
sensitivity of the proposed detector to light dark matter particles is
estimated for various electric fields and light collection efficiencies.
[35]
oai:arXiv.org:1207.3665 [pdf] - 1124847
The LUX Prototype Detector: Heat Exchanger Development
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Cahn, S.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, C. E.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Fiorucci, S.;
Gaitskell, R. J.;
Hall, C.;
Faham, C.;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Kwong, J.;
Lander, R.;
Leonard, D.;
Malling, D.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nikkel, J.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Steigler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2012-07-16, last modified: 2013-01-20
The LUX (Large Underground Xenon) detector is a two-phase xenon Time
Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter
interactions. As with all noble element detectors, continuous purification of
the detector medium is essential to produce a large ($>$1ms) electron lifetime;
this is necessary for efficient measurement of the electron signal which in
turn is essential for achieving robust discrimination of signal from background
events. In this paper we describe the development of a novel purification
system deployed in a prototype detector. The results from the operation of this
prototype indicated heat exchange with an efficiency above 94% up to a flow
rate of 42 slpm, allowing for an electron drift length greater than 1 meter to
be achieved in approximately two days and sustained for the duration of the
testing period.
[36]
oai:arXiv.org:1211.0836 [pdf] - 1157501
The distributed Slow Control System of the XENON100 Experiment
Aprile, E.;
Alfonsi, M.;
Arisaka, K.;
Arneodo, F.;
Balan, C.;
Baudis, L.;
Behrens, A.;
Beltrame, P.;
Bokeloh, K.;
Brown, E.;
Bruno, G. M.;
Budnik, R.;
Calloch, M. Le;
Cardoso, J. M.;
Chen, W. -T.;
Choi, B.;
Contreras, H.;
Cussonneau, J. -P.;
Decowski, M. P.;
Duchovni, E.;
Fattori, S.;
Ferella, A. D.;
Fulgione, W.;
Gao, F.;
Garbini, M.;
Giboni, K. -L.;
Goetzke, L.;
Grignon, C.;
Gross, E.;
Hampel, W.;
McKinsey, D. N.;
Kish, A.;
Lamblin, J.;
Lang, R. F.;
Levy, C.;
Lim, K. E.;
Lin, Q.;
Lindemann, S.;
Lindner, M.;
Lopes, J. A. M.;
Lung, K.;
Manzur, A.;
Undagoitia, T. Marrodán;
Massoli, F. V.;
Mei, Y.;
Fernandez, A. J. Melgarejo;
Meng, Y.;
Molinario, A.;
Nativ, E.;
Ni, K.;
Oberlack, U.;
Orrigo, S. E. A.;
Pantic, E.;
Patricio, J. V.;
Persiani, R.;
Plante, G.;
Priel, N.;
Ribeiro, A. C. C.;
Rizzo, A.;
Rosendahl, S.;
Santos, J. M. F. dos;
Sartorelli, G.;
Schreiner, J.;
Schumann, M.;
Lavina, L. Scotto;
Scovell, P. R.;
Selvi, M.;
Shagin, P.;
Simgen, H.;
Teymourian, A.;
Thers, D.;
Vitells, O.;
Wang, H.;
Weber, M.;
Weinheimer, C.
Submitted: 2012-11-05
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso (LNGS) in Italy, was designed to search for evidence of dark matter
interactions inside a volume of liquid xenon using a dual-phase time projection
chamber. This paper describes the Slow Control System (SCS) of the experiment
with emphasis on the distributed architecture as well as on its modular and
expandable nature. The system software was designed according to the rules of
Object-Oriented Programming and coded in Java, thus promoting code reusability
and maximum flexibility during commissioning of the experiment. The SCS has
been continuously monitoring the XENON100 detector since mid 2008, remotely
recording hundreds of parameters on a few dozen instruments in real time, and
setting emergency alarms for the most important variables.
[37]
oai:arXiv.org:1111.3260 [pdf] - 548322
Scintillation yield and time dependence from electronic and nuclear
recoils in liquid neon
Submitted: 2011-11-14, last modified: 2012-08-13
We have performed measurements of scintillation light in liquid neon,
observing a signal yield in our detector as high as (3.5 $\pm$ 0.4)
photoelectrons/keV. We measure pulse shape discrimination efficiency between
electronic and nuclear recoils in liquid neon from 50 and 300 keV nuclear
recoil energy. We also measure the \leff\, parameter in liquid neon between 30
and 370 keV nuclear recoil energy, observing an average \leff$=0.24$ above 50
keV. We observe a dependence of the scintillation time distribution and signal
yield on the pressure and temperature of the liquid neon.
[38]
oai:arXiv.org:1004.0373 [pdf] - 672810
Measurement of scintillation efficiency for nuclear recoils in liquid
argon
Submitted: 2010-04-02, last modified: 2012-05-08
The scintillation light yield of liquid argon from nuclear recoils relative
to electronic recoils has been measured as a function of recoil energy from 10
keVr up to 250 keVr. The scintillation efficiency, defined as the ratio of the
nuclear recoil scintillation response to the electronic recoil response, is
0.25 \pm 0.01 + 0.01(correlated) above 20 keVr.
[39]
oai:arXiv.org:1110.0103 [pdf] - 967104
After LUX: The LZ Program
Malling, D. C.;
Akerib, D. S.;
Araujo, H. M.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Currie, A.;
Dazeley, S.;
de Viveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lindote, A.;
Lopes, M. I.;
Lyashenko, A.;
Majewski, P.;
Mannino, R.;
McKinsey, D. N.;
Mei, D. -M.;
Mock, J.;
Morii, M.;
Murphy, A. St J.;
Nelson, H.;
Neves, F.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Reichhart, L.;
Shutt, T.;
Silva, C.;
Skulski, W.;
Solovov, V.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Sumner, T. J.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-10-01, last modified: 2011-10-13
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.
[40]
oai:arXiv.org:1109.5649 [pdf] - 1084392
Scintillation and charge extraction from the tracks of energetic
electrons in superfluid helium-4
Submitted: 2011-09-26
An energetic electron passing through liquid helium causes ionization along
its track. The ionized electrons quickly recombine with the resulting positive
ions, which leads to the production of prompt scintillation light. By applying
appropriate electric fields, some of the ionized electrons can be separated
from their parent ions. The fraction of the ionized electrons extracted in a
given applied field depends on the separation distance between the electrons
and the ions. We report the determination of the mean electron-ion separation
distance for charge pairs produced along the tracks of beta particles in
superfluid helium at 1.5 K by studying the quenching of the scintillation light
under applied electric fields. Knowledge of this mean separation parameter will
aid in the design of particle detectors that use superfluid helium as a target
material.
[41]
oai:arXiv.org:1108.1836 [pdf] - 1083296
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Akerib, D. S.;
Bai, X.;
Bedikian, S.;
Bernard, E.;
Bernstein, A.;
Bradley, A.;
Cahn, S. B.;
Carmona-Benitez, M. C.;
Carr, D.;
Chapman, J. J.;
Clark, K.;
Classen, T.;
Coffey, T.;
Curioni, A.;
Dazeley, S.;
deViveiros, L.;
Dragowsky, M.;
Druszkiewicz, E.;
Faham, C. H.;
Fiorucci, S.;
Gaitskell, R. J.;
Gibson, K. R.;
Hall, C.;
Hanhardt, M.;
Holbrook, B.;
Ihm, M.;
Jacobsen, R. G.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Larsen, N.;
Lee, C.;
Leonard, D.;
Lesko, K.;
Lyashenko, A.;
Malling, D. C.;
Mannino, R.;
McKinsey, D. N.;
Mei, D.;
Mock, J.;
Morii, M.;
Nelson, H.;
Nikkel, J. A.;
Pangilinan, M.;
Phelps, P.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Szydagis, M.;
Thomson, J.;
Tripathi, M.;
Verbus, J. R.;
Walsh, N.;
Webb, R.;
White, J. T.;
Wlasenko, M.;
Wolfs, F. L. H.;
Woods, M.;
Zhang, C.
Submitted: 2011-08-08, last modified: 2011-08-09
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils from interactions with dark matter particles. Signals
from the LUX detector are processed by custom-built analog electronics which
provide properly shaped signals for the trigger and data acquisition (DAQ)
systems. The DAQ is comprised of commercial digitizers with firmware customized
for the LUX experiment. Data acquisition systems in rare-event searches must
accommodate high rate and large dynamic range during precision calibrations
involving radioactive sources, while also delivering low threshold for maximum
sensitivity. The LUX DAQ meets these challenges using real-time baseline sup-
pression that allows for a maximum event acquisition rate in excess of 1.5 kHz
with virtually no deadtime. This paper describes the LUX DAQ and the novel
acquisition techniques employed in the LUX experiment.
[42]
oai:arXiv.org:0910.3698 [pdf] - 270011
Constraints on inelastic dark matter from XENON10
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2009-10-19, last modified: 2010-11-30
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
[43]
oai:arXiv.org:1011.6439 [pdf] - 270289
Lowering the low-energy threshold of xenon detectors
Sorensen, P.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2010-11-29
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
[44]
oai:arXiv.org:1007.1005 [pdf] - 283573
A Consistent Dark Matter Interpretation For CoGeNT and DAMA/LIBRA
Submitted: 2010-07-06, last modified: 2010-10-27
In this paper, we study the recent excess of low energy events observed by
the CoGeNT collaboration and the annual modulation reported by the DAMA/LIBRA
collaboration, and discuss whether these signals could both be the result of
the same elastically scattering dark matter particle. We find that, without
channeling but when taking into account uncertainties in the relevant quenching
factors, a dark matter candidate with a mass of approximately ~7.0 GeV and a
cross section with nucleons of sigma_{DM-N} ~2x10^-4 pb (2x10^-40 cm^2) could
account for both of these observations. We also comment on the events recently
observed in the oxygen band of the CRESST experiment and point out that these
could potentially be explained by such a particle. Lastly, we compare the
region of parameter space favored by DAMA/LIBRA and CoGeNT to the constraints
from XENON 10, XENON 100, and CDMS (Si) and find that these experiments cannot
at this time rule out a dark matter interpretation of these signals.
[45]
oai:arXiv.org:1005.3723 [pdf] - 169132
Response to arXiv:1005.2615
Submitted: 2010-05-20
Brief response to a Reply [arXiv:1005.2615] on our Comments [arXiv:1005.0838]
on XENON100 recent results [arXiv:1005.0380].
[46]
oai:arXiv.org:1005.0838 [pdf] - 164844
Comments on "First Dark Matter Results from the XENON100 Experiment"
Submitted: 2010-05-05, last modified: 2010-05-12
The XENON100 collaboration has recently released new dark matter limits,
placing particular emphasis on their impact on searches known to be sensitive
to light-mass (below 10 GeV/c^2) Weakly Interacting Massive Particles (WIMPs),
such as DAMA and CoGeNT. We describe here several sources of uncertainty and
bias in their analysis that make their new claimed sensitivity presently
untenable. In particular, we point out additional work in this field and simple
kinematic arguments that indicate that liquid xenon (LXe) may be a relatively
insensitive detection medium for the recoil energies (few keV_r) expected from
such low mass WIMPs.
[47]
oai:arXiv.org:0909.1063 [pdf] - 142221
Scintillation efficiency and ionization yield of liquid xenon for
mono-energetic nuclear recoils down to 4 keV
Submitted: 2009-09-05, last modified: 2010-01-18
Liquid Xenon (LXe) is an excellent material for experiments designed to
detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs).
A low energy detection threshold is essential for a sensitive WIMP search. The
understanding of the relative scintillation efficiency (Leff) and ionization
yield of low energy nuclear recoils in LXe is limited for energies below 10
keV. In this paper, we present new measurements that extend the energy down to
4 keV, finding that Leff decreases with decreasing energy. We also measure the
quenching of scintillation efficiency due to the electric field in LXe, finding
no significant field dependence.
[48]
oai:arXiv.org:1001.2834 [pdf] - 348097
Design and Performance of the XENON10 Dark Matter Experiment
Aprile, E.;
Angle, J.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Orlandi, D.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Tatananni, E.;
Winant, C.;
Yamashita, M.
Submitted: 2010-01-16
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
[49]
oai:arXiv.org:0905.1766 [pdf] - 24160
Calibration of a Liquid Xenon Detector with Kr-83m
Submitted: 2009-05-12, last modified: 2009-12-11
We report the preparation of a Kr-83m source and its subsequent use in
calibrating a liquid xenon detector. Kr-83m atoms were produced through the
decay of Rb-83 atoms trapped in zeolite molecular sieve and were then
introduced into liquid xenon. Decaying Kr-83m nuclei were detected through
liquid xenon scintillation. Conversion electrons with energies of 9.4 keV and
32.1 keV from the decay of Kr-83m were both observed. This calibration source
will allow the characterization of the scintillation and ionization response of
noble liquid detectors at low energies, highly valuable for the search for WIMP
dark matter. Kr-83m may also be useful for measuring fluid flow dynamics, both
to understand purification in noble liquid-based particle detectors, as well as
for studies of classical and quantum turbulence in superfluid helium.
[50]
oai:arXiv.org:0912.0482 [pdf] - 902613
Status of the LUX Dark Matter Search
Fiorucci, S.;
Akerib, D. S.;
Bedikian, S.;
Bernstein, A.;
Bolozdynya, A.;
Bradley, A.;
Carr, D.;
Chapman, J.;
Clark, K.;
Classen, T.;
Curioni, A.;
Dahl, E.;
Dazeley, S.;
de Viveiros, L.;
Druszkiewicz, E.;
Gaitskell, R.;
Hall, C.;
Faham, C. Hernandez;
Holbrook, B.;
Kastens, L.;
Kazkaz, K.;
Lander, R.;
Lesko, K.;
Malling, D.;
Mannino, R.;
McKinsey, D.;
Mei, D.;
Mock, J.;
Nikkel, J.;
Phelps, P.;
Schroeder, U.;
Shutt, T.;
Skulski, W.;
Sorensen, P.;
Spaans, J.;
Stiegler, T.;
Svoboda, R.;
Sweany, M.;
Thomson, J.;
Toke, J.;
Tripathi, M.;
Walsh, N.;
Webb, R.;
White, J.;
Wolfs, F.;
Woods, M.;
Zhang, C.
Submitted: 2009-12-02
The Large Underground Xenon (LUX) dark matter search experiment is currently
being deployed at the Homestake Laboratory in South Dakota. We will highlight
the main elements of design which make the experiment a very strong competitor
in the field of direct detection, as well as an easily scalable concept. We
will also present its potential reach for supersymmetric dark matter detection,
within various timeframes ranging from 1 year to 5 years or more.
[51]
oai:arXiv.org:0911.5453 [pdf] - 146838
Calibration of liquid argon and neon detectors with $^{83}Kr^m$
Submitted: 2009-11-30
We report results from tests of $^{83}$Kr$^{\mathrm{m}}$, as a calibration
source in liquid argon and liquid neon. $^{83}$Kr$^{\mathrm{m}}$ atoms are
produced in the decay of $^{83}$Rb, and a clear $^{83}$Kr$^{\mathrm{m}}$
scintillation peak at 41.5 keV appears in both liquids when filling our
detector through a piece of zeolite coated with $^{83}$Rb. Based on this
scintillation peak, we observe 6.0 photoelectrons/keV in liquid argon with a
resolution of 6% ($\sigma$/E) and 3.0 photoelectrons/keV in liquid neon with a
resolution of 19% ($\sigma$/E). The observed peak intensity subsequently decays
with the $^{83}$Kr$^{\mathrm{m}}$ half-life after stopping the fill, and we
find evidence that the spatial location of $^{83}$Kr$^{\mathrm{m}}$ atoms in
the chamber can be resolved. $^{83}$Kr$^{\mathrm{m}}$ will be a useful
calibration source for liquid argon and neon dark matter and solar neutrino
detectors.
[52]
oai:arXiv.org:0807.0459 [pdf] - 1937508
The scintillation and ionization yield of liquid xenon for nuclear
recoils
Sorensen, P.;
Manzur, A.;
Dahl, C. E.;
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-07-03, last modified: 2008-12-30
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
[53]
oai:arXiv.org:0805.2939 [pdf] - 1937505
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10
experiment
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2008-05-19, last modified: 2008-09-10
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
[54]
oai:arXiv.org:0709.1880 [pdf] - 4868
Detection and Imaging of He_2 Molecules in Superfluid Helium
Submitted: 2007-09-12, last modified: 2007-12-18
We present data that show a cycling transition can be used to detect and
image metastable He$_2$ triplet molecules in superfluid helium. We demonstrate
that limitations on the cycling efficiency due to the vibrational structure of
the molecule can be mitigated by the use of repumping lasers. Images of the
molecules obtained using the method are also shown. This technique gives rise
to a new kind of ionizing radiation detector. The use of He$_2$ triplet
molecules as tracer particles in the superfluid promises to be a powerful tool
for visualization of both quantum and classical turbulence in liquid helium.
[55]
oai:arXiv.org:0706.0039 [pdf] - 1934124
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso
National Laboratory
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Brusov, P.;
Coelho, L. C. C.;
Dahl, C. E.;
DeViveiros, L.;
Ferella, A. D.;
Fernandes, L. M. P.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. L.;
Gomez, R.;
Hasty, R.;
Kastens, L.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D. N.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santorelli, R.;
Santos, J. M. F. dos;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Schulte, S.;
Winant, C.;
Yamashita, M.
Submitted: 2007-05-31, last modified: 2007-12-03
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
[56]
oai:arXiv.org:0708.1976 [pdf] - 3998
Preparation of Neutron-activated Xenon for Liquid Xenon Detector
Calibration
Submitted: 2007-08-14, last modified: 2007-09-27
We report the preparation of neutron-activated xenon for the calibration of
liquid xenon (LXe) detectors. Gamma rays from the decay of xenon metastable
states, produced by fast neutron activation, were detected and their activities
measured in a LXe scintillation detector. Following a five-day activation of
natural xenon gas with a Cf-252 (4 x 10^5 n/s) source, the activities of two
gamma ray lines at 164 keV and 236 keV, from Xe-131m and Xe-129m metastable
states, were measured at about 95 and 130 Bq/kg, respectively. We also observed
three additional lines at 35 keV, 100 keV and 275 keV, which decay away within
a few days. No long-lifetime activity was observed after the neutron
activation.
[57]
oai:arXiv.org:0706.1106 [pdf] - 2001
Toward Application of a Thick Gas Electron Multiplier (THGEM) Readout
for a Dark Matter Detector
Submitted: 2007-06-07
The Yale-Weizmann collaboration aims to develop a low-radioactivity
(low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in
measurements to be performed deep underground as for example carried out by the
XENON collaboration. A major issue is the background induced by natural
radioactivity of present-detector components including the Photo Multiplier
Tubes (PMT) made from glass with large U-Th content. We propose to use advanced
Thick Gaseous Electron Multipliers (THGEM) recently developed at the Weizmann
Institute of Science (WIS). These "hole-multipliers" will measure in a
two-phase (liquid/gas) Xe detector electrons extracted into the gas phase from
both ionization in the liquid as well as scintillation-induced photoelectrons
from a CsI photocathode immersed in LXe. We report on initial tests (in gas) of
THGEM made out of Cirlex (Kapton) which is well known to have low Ra-Th content
instead of the usual G10 material with high Ra-Th content.
[58]
oai:arXiv.org:astro-ph/0702202 [pdf] - 89256
Demonstration of photomultiplier tube operation at 29 K
Submitted: 2007-02-07
We describe measurements of gain, dark current, and quantum efficiency
obtained while cooling a Hamamatsu R5912-02-MOD photomultiplier tube from room
temperature to 29 K. We found that the PMT operated normally down to 29 K, with
a reduced gain and quantum efficiency at the lowest temperatures. Furthermore,
we found that the dark count rate increased as the temperature decreased. We
conclude that these PMTs appear to be adequate for the requirements of the
CLEAN experiment.
[59]
oai:arXiv.org:astro-ph/0612108 [pdf] - 87446
Scintillation of liquid neon from electronic and nuclear recoils
Submitted: 2006-12-04
We have measured the time dependence of scintillation light from electronic
and nuclear recoils in liquid neon, finding a slow time constant of 15.4+-0.2
us. Pulse shape discrimination is investigated as a means of identifying event
type in liquid neon. Finally, the nuclear recoil scintillation efficiency is
measured to be 0.26+-0.03 for 387 keV nuclear recoils.
[60]
oai:arXiv.org:astro-ph/0609714 [pdf] - 85306
3D Position Sensitive XeTPC for Dark Matter Search
Angle, J.;
Aprile, E.;
Arneodo, F.;
Baudis, L.;
Bernstein, A.;
Bolozdynya, A.;
Coelho, L.;
Dahl, E.;
DeViveiros, L.;
Ferella, A.;
Fernandes, L.;
Fiorucci, S.;
Gaitskell, R. J.;
Giboni, K. -L.;
Gomez, R.;
Hasty, R.;
Kwong, J.;
Lopes, J. A. M.;
Madden, N.;
Manalaysay, A.;
Manzur, A.;
McKinsey, D.;
Monzani, M. E.;
Ni, K.;
Oberlack, U.;
Orboeck, J.;
Plante, G.;
Santos, J.;
Shagin, P.;
Shutt, T.;
Sorensen, P.;
Winant, C.;
Yamashita, M.
Submitted: 2006-09-26
The technique to realize 3D position sensitivity in a two-phase xenon time
projection chamber (XeTPC) for dark matter search is described. Results from a
prototype detector (XENON3) are presented.
[61]
oai:arXiv.org:astro-ph/0503621 [pdf] - 72003
Scintillation Response of Liquid Xenon to Low Energy Nuclear Recoils
Submitted: 2005-03-29
Liquid Xenon (LXe) is expected to be an excellent target and detector medium
to search for dark matter in the form of Weakly Interacting Massive Particles
(WIMPs). Knowledge of LXe ionization and scintillation response to low energy
nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important
for determining the sensitivity of LXe direct detection experiments. Here we
report on new measurements of the scintillation yield of Xe recoils with
kinetic energy as low as 10 keV. The dependence of the scintillation yield on
applied electric field was also measured in the range of 0 to 4 kV/cm. Results
are in good agreement with recent theoretical predictions that take into
account the effect of biexcitonic collisions in addition to the nuclear
quenching effect.
[62]
oai:arXiv.org:nucl-ex/0503006 [pdf] - 118468
Trace Detection of Metastable Helium Molecules in Superfluid Helium by
Laser-Induced Fluorescence
Submitted: 2005-03-11
We describe an approach to detecting ionizing radiation that combines the
special properties of superfluid helium with the sensitivity of quantum optics
techniques. Ionization in liquid helium results in the copious production of
metastable helium molecules, which can be detected by laser-induced
fluorescence. Each molecule can be probed many times using a cycling
transition, resulting in the detection of individual molecules with high signal
to noise. This technique could be used to detect neutrinos, weakly interacting
massive particles, and ultracold neutrons, and to image superfluid flow in
liquid He-4.
[63]
oai:arXiv.org:astro-ph/0407575 [pdf] - 66417
The XENON Dark Matter Search Experiment
Aprile, E.;
Giboni, K. L.;
Majewski, P.;
Ni, K.;
Yamashita, M.;
Gaitskell, R.;
Sorensen, P.;
DeViveiros, L.;
Baudis, L.;
Bernstein, A.;
Hagmann, C.;
Winant, C.;
Shutt, T.;
Kwong, J.;
Oberlack, U.;
McKinsey, D.;
Hasty, R.
Submitted: 2004-07-28
The XENON experiment aims at the direct detection of dark matter in the form
of WIMPs (Weakly Interacting Massive Particles) via their elastic scattering
off Xe nuclei. A fiducial mass of 1000 kg, distributed in ten independent
liquid xenon time projection chambers(LXeTPCs) will be used to probe thelowest
interaction cross section predicted by SUSY models. The TPCs are operated in
dual (liquid/gas) phase, to allow a measurement of nuclear recoils down to
16keV energy, via simultaneous detection of the ionization, through secondary
scintillation in the gas, and primary scintillation in the liquid. Thedistinct
ratio of primary to secondary scintillation for nuclear recoils from WIMPs (or
neutrons), and for electron recoils from background, iskey to the
event-by-event discrimination capability of XENON. A dual phase xenon prototype
has been realized and is currently being tested, along with otherprototypes
dedicated to other measurements relevant to the XENON program. As part of the
R&D phase, we will realize and move underground a first XENON module (XENON10)
with at least 10 kg fiducial mass to measure the background rejection
capability and to optimize the conditions for continuous and stable detector
operation underground. We present some of the results from the ongoing R&D and
summarize the expected performance of the 10 kg experiment, from MonteCarlo
simulations. The main design features of the 100 kg detector unit(XENON100),
with which we envisage to make up the 1 tonne sensitive mass ofXENON1T will
also be presented.
[64]
oai:arXiv.org:astro-ph/0406526 [pdf] - 65683
Radioactive Krypton Background Evaluation Using Atom Counting
Submitted: 2004-06-23
The beta-decay of $\rm^{85}Kr$ is a significant radioactive background for
experiments that use liquified noble gases to search for dark matter and
measure the low-energy solar neutrino flux. While there are several proposed
methods for reducing Kr levels in these experiments, an independent technique
is needed for measuring very low Kr levels. By selectively exciting Kr atoms to
a metastable state, capturing them in a magneto-optical trap (MOT), and
detecting fluorescence from the trapped atoms, individual Kr atoms can be
counted with a high signal-to-noise ratio. This approach could be used to
ascertain Kr impurity levels in other noble gases, with an estimated
sensitivity of $3\times 10^{-14}$.
[65]
oai:arXiv.org:astro-ph/0402007 [pdf] - 62521
Neutrino Detection With CLEAN
Submitted: 2004-01-31, last modified: 2004-02-08
This article describes CLEAN, an approach to the detection of low-energy
solar neutrinos and neutrinos released from supernovae. The CLEAN concept is
based on the detection of elastic scattering events (neutrino-electron
scattering and neutrino-nuclear scattering) in liquified noble gases such as
liquid helium, liquid neon, and liquid xenon, all of which scintillate brightly
in the ultraviolet. Key to the CLEAN technique is the use of a thin film of
wavelength-shifting fluor to convert the ultraviolet scintillation light to the
visible. This allows the same liquid to be used as both a passive shielding
medium and an active self-shielding detector, allowing lower intrinsic
radioactive backgrounds at low energies. Liquid neon is a particularly
promising medium for CLEAN. Because liquid neon has a high scintillation yield,
has no long-lived radioactive isotopes, and can be easily purified by use of
cold traps, it is an ideal medium for the detection of rare nuclear events. In
addition, neon is inexpensive, dense, and transparent to its own scintillation
light, making it practical for use in a large self-shielding apparatus. Monte
Carlo simulations of gamma ray backgrounds have been performed assuming liquid
neon as both shielding and detection medium. Gamma ray events occur with high
probability in the outer parts of the detector. In contrast, neutrino
scattering events occur uniformly throughout the detector. We discriminate
background gamma ray events from events of interest based on a spatial Maximum
Likelihood method estimate of event location. Background estimates for CLEAN
are presented, as well as an evaluation of the sensitivity of the detector for
$p-p$ neutrinos. Given these simulations, the physics potential of the CLEAN
approach is evaluated.
[66]
oai:arXiv.org:physics/0309033 [pdf] - 119023
Spatial methods for event reconstruction in CLEAN
Submitted: 2003-09-04
In CLEAN (Cryogenic Low Energy Astrophysics with Noble gases), a proposed
neutrino and dark matter detector, background discrimination is possible if one
can determine the location of an ionizing radiation event with high accuracy.
We simulate ionizing radiation events that produce multiple scintillation
photons within a spherical detection volume filled with liquid neon. We
estimate the radial location of a particular ionizing radiation event based on
the observed count data corresponding to that event. The count data are
collected by detectors mounted at the spherical boundary of the detection
volume. We neglect absorption, but account for Rayleigh scattering. To account
for wavelength-shifting of the scintillation light, we assume that photons are
absorbed and re-emitted at the detectors. Here, we develop spatial Maximum
Likelihood methods for event reconstruction, and study their performance in
computer simulation experiments. We also study a method based on the centroid
of the observed count data. We calibrate our estimates based on training data.
[67]
oai:arXiv.org:astro-ph/0302071 [pdf] - 54698
Supernova Observation Via Neutrino-Nucleus Elastic Scattering in the
CLEAN Detector
Submitted: 2003-02-04
Development of large mass detectors for low-energy neutrinos and dark matter
may allow supernova detection via neutrino-nucleus elastic scattering. An
elastic-scattering detector could observe a few, or more, events per ton for a
galactic supernova at 10 kpc ($3.1 \times 10^{20}$ m). This large yield, a
factor of at least 20 greater than that for existing light-water detectors,
arises because of the very large coherent cross section and the sensitivity to
all flavors of neutrinos and antineutrinos. An elastic scattering detector can
provide important information on the flux and spectrum of $\nu_\mu$ and
$\nu_\tau$ from supernovae. We consider many detectors and a range of target
materials from $^4$He to $^{208}$Pb. Monte Carlo simulations of low-energy
backgrounds are presented for the liquid-neon-based Cryogenic Low Energy
Astrophysics with Noble gases (CLEAN) detector. The simulated background is
much smaller than the expected signal from a galactic supernova.
[68]
oai:arXiv.org:astro-ph/9907314 [pdf] - 107539
Liquid Helium and Liquid Neon - Sensitive, Low Background Scintillation
Media For the Detection of Low Energy Neutrinos
Submitted: 1999-07-22, last modified: 1999-09-28
The use of liquid helium and neon as scintillators for neutrino detection is
investigated. Several unique properties of these cryogens make them promising
candidates for real-time solar neutrino spectroscopy: large ultraviolet
scintillation yields from ionizing radiation, transparency to their own
scintillation light, and low levels of radioactive impurities. When neutrinos
scatter from electrons in liquid helium or neon, ultraviolet light is emitted.
The ultraviolet scintillation light can be efficiently converted to the visible
with wavelength shifting films. In this way the neutrino-electron scattering
events can be detected by photomultiplier tubes at room temperature. We
conclude that the solar neutrino flux from the $\rm p+p\to e^{+}+d+\nu_{e}$
reaction could be characterized and monitored versus time using a 10 ton mass
of liquid helium or neon as a scintillation target.